The Relevance of the Primary Prevention Criteria for Implantable Cardioverter Defibrillator Implantation in Korean Symptomatic Severe Heart Failure Patients
The study group consisted of 275 consecutive patients (mean age 65 years, 71% male) who met the ICD implantation criteria for primary prevention (left ventricular ejection fraction 0.05). All-cause mortality and the incidence of SCD in the NICMP group were comparable to those of the DEFINITE standard therapy group (13% vs. 17%, 6% vs. 6%, respectively, all p>0.05).
CONCLUSION:
Korean patients with severe heart failure in both the ICMP and NICMP groups had all-caused mortality and risk of SCD comparable to patients in the MADIT-II and DEFINITE standard therapy groups. Therefore, the primary prevention criteria for ICD implantation would be appropriate in both Korean ICMP and NICMP patients.