Objective@#To evaluate the application of self-made-dispensing-ampoule car in the medicine dispensing for venous transfusion.@*Methods@#The self-made-dispensing-ampoule car made based on the ergonomics is a temporary carrier device for medical waste in the need of the whole process of dispensing process. The overall exterior is made of 304 stainless steel, separated into 2 layers. The Upper layer has a frame with integral medicineglass hole made of stainless steel, which can be dismantled from the upper layer. The medicineglasses are small empty medicine bottles used to hold the dispensed medicine; while the lower layer is a slide platform which can put on 3 medical wasteclassificationboxes. The bottom has universal wheels with brakes to help the car move and stop. To focus on 42 emergency departmentnurses using the device, to analyze their error rate of medicine dispensing, the dispensing time for the same batch of patients with same dosages and shuttle time from dispensing car to buffer room to pour medical waste and compare the data the year before and the year using the device.@*Results@#After using it, the dispensing error occurrence rate and nurses dispensing time and shuttle times of pouring waste were 0.31 ‱ (3/97 785), (70.08±3.28) min/time, two times, which were all obviously lower than 1.95‱ (18/92 095), (110.04±6.91) min/time, 30 times without using it (χ2=11.64, 204.16, t=71.70, all P<0.01).@*Conclusion@#Using the dispensing ampoule car can optimize the dispensing process in dispensing of venous transfusion, ensure patients with safe venous transfusion, raise the efficiency of nurses saving time and efforts.