Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
2.
Arq Bras Cardiol ; 116(6): 1091-1098, 2021 06.
Article in English, Portuguese | MEDLINE | ID: mdl-34133592

ABSTRACT

BACKGROUND: The non-invasive quantification of the fractional flow reserve (FFRCT) using a more recent version of an artificial intelligence-based software and latest generation CT scanner (384 slices) may show high performance to detect coronary ischemia. OBJECTIVES: To evaluate the diagnostic performance of FFRCT for the detection of significant coronary artery disease (CAD) in contrast to invasive FFR (iFFR) using previous generation CT scanners (128 and 256- detector rows). METHODS: Retrospective study with patients referred to coronary artery CT angiography (CTA) and catheterization (iFFR) procedures. Siemens Somatom Definition Flash (256-detector rows) and AS+ (128-detector rows) CT scanners were used to acquire the images. The FFRCT and the minimal lumen area (MLA) were evaluated using a dedicated software (cFFR version 3.0.0, Siemens Healthineers, Forchheim, Germany). Obstructive CAD was defined as CTA lumen reduction ≥ 50%, and flow-limiting stenosis as iFFR ≤0.8. All reported P values are two-tailed, and when <0.05, they were considered statistically significant. RESULTS: Ninety-three consecutive patients (152 vessels) were included. There was good agreement between FFRCT and iFFR, with minimal FFRCT overestimation (bias: -0.02; limits of agreement:0.14-0.09). Different CT scanners did not modify the association between FFRCT and FFRi (p for interaction=0.73). The performance of FFRCT was significantly superior compared to the visual classification of coronary stenosis (AUC 0.93vs.0.61, p<0.001) and to MLA (AUC 0.93vs.0.75, p<0.001), reducing the number of false-positive cases. The optimal cut-off point for FFRCT using a Youden index was 0.85 (87% Sensitivity, 86% Specificity, 73% PPV, 94% NPV), with a reduction of false-positives. CONCLUSION: Machine learning-based FFRCT using previous generation CT scanners (128 and 256-detector rows) shows good diagnostic performance for the detection of CAD, and can be used to reduce the number of invasive procedures.


FUNDAMENTO: A quantificação não invasiva da reserva fracionada de fluxo miocárdico (FFR TC ) através de software baseado em inteligência artificial em versão mais atualizada e tomógrafo de última geração (384 cortes) apresenta elevada performance na detecção de isquemia coronariana. OBJETIVOS: Avaliar o desempenho diagnóstico da FFR TC na detecção de doença arterial coronariana (DAC) significativa em relação ao FFRi, em tomógrafos de gerações anteriores (128 e 256 cortes). MÉTODOS: Estudo retrospectivo com pacientes encaminhados à angiotomografia de artérias coronárias (TCC) e cateterismo (FFRi). Foram utilizados os tomógrafos Siemens Somatom Definition Flash (256 cortes) e AS+ (128 cortes). A FFR TC e a área luminal mínima (ALM) foram avaliadas em software (cFFR versão 3.0.0, Siemens Healthineers, Forchheim, Alemanha). DAC obstrutiva foi definida como TCC com redução luminal ≥50% e DAC funcionalmente obstrutiva como FFRi ≤0,8. Todos os valores de p reportados são bicaudais; e quando <0,05, foram considerados estatisticamente significativos. RESULTADOS: Noventa e três pacientes consecutivos (152 vasos) foram incluídos. Houve boa concordância entre FFR TC e FFRi, com mínima superestimação da FFR TC (viés: ­0,02; limites de concordância: 0,14 a 0,09). Diferentes tomógrafos não modificaram a relação entre FFR TC e FFRi (p para interação = 0,73). A FFR TC demonstrou performance significativamente superior à classificação visual de estenose coronariana (AUC 0,93 vs. 0,61, p <0,001) e à ALM (AUC 0,93 vs. 0,75, p <0,001) reduzindo o número de casos falso-positivos. O melhor ponto de corte para a FFR TC utilizando um índice de Youden foi de 0,85 (sensiblidade, 87%; especificidade, 86%; VPP, 73%; NPV, 94%), com redução de falso-positivos. CONCLUSÃO: FFR TC baseada em inteligência artificial, em tomógrafos de gerações anteriores (128 e 256 cortes), apresenta boa performance diagnóstica na detecção de DAC, podendo ser utilizada para reduzir procedimentos invasivos.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Artificial Intelligence , Computed Tomography Angiography , Constriction, Pathologic , Coronary Angiography , Coronary Vessels , Humans , Machine Learning , Predictive Value of Tests , Retrospective Studies , Severity of Illness Index , Tomography, X-Ray Computed
3.
Arq. bras. cardiol ; 116(6): 1091-1098, Jun. 2021. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1278330

ABSTRACT

Resumo Fundamento A quantificação não invasiva da reserva fracionada de fluxo miocárdico (FFR TC ) através de software baseado em inteligência artificial em versão mais atualizada e tomógrafo de última geração (384 cortes) apresenta elevada performance na detecção de isquemia coronariana. Objetivos Avaliar o desempenho diagnóstico da FFR TC na detecção de doença arterial coronariana (DAC) significativa em relação ao FFRi, em tomógrafos de gerações anteriores (128 e 256 cortes). Métodos Estudo retrospectivo com pacientes encaminhados à angiotomografia de artérias coronárias (TCC) e cateterismo (FFRi). Foram utilizados os tomógrafos Siemens Somatom Definition Flash (256 cortes) e AS+ (128 cortes). A FFR TC e a área luminal mínima (ALM) foram avaliadas em software (cFFR versão 3.0.0, Siemens Healthineers, Forchheim, Alemanha). DAC obstrutiva foi definida como TCC com redução luminal ≥50% e DAC funcionalmente obstrutiva como FFRi ≤0,8. Todos os valores de p reportados são bicaudais; e quando <0,05, foram considerados estatisticamente significativos. Resultados Noventa e três pacientes consecutivos (152 vasos) foram incluídos. Houve boa concordância entre FFR TC e FFRi, com mínima superestimação da FFR TC (viés: -0,02; limites de concordância: 0,14 a 0,09). Diferentes tomógrafos não modificaram a relação entre FFR TC e FFRi (p para interação = 0,73). A FFR TC demonstrou performance significativamente superior à classificação visual de estenose coronariana (AUC 0,93 vs. 0,61, p <0,001) e à ALM (AUC 0,93 vs. 0,75, p <0,001) reduzindo o número de casos falso-positivos. O melhor ponto de corte para a FFR TC utilizando um índice de Youden foi de 0,85 (sensiblidade, 87%; especificidade, 86%; VPP, 73%; NPV, 94%), com redução de falso-positivos. Conclusão FFR TC baseada em inteligência artificial, em tomógrafos de gerações anteriores (128 e 256 cortes), apresenta boa performance diagnóstica na detecção de DAC, podendo ser utilizada para reduzir procedimentos invasivos.


Abstract Background The non-invasive quantification of the fractional flow reserve (FFRCT) using a more recent version of an artificial intelligence-based software and latest generation CT scanner (384 slices) may show high performance to detect coronary ischemia. Objectives To evaluate the diagnostic performance of FFRCT for the detection of significant coronary artery disease (CAD) in contrast to invasive FFR (iFFR) using previous generation CT scanners (128 and 256- detector rows). Methods Retrospective study with patients referred to coronary artery CT angiography (CTA) and catheterization (iFFR) procedures. Siemens Somatom Definition Flash (256-detector rows) and AS+ (128-detector rows) CT scanners were used to acquire the images. The FFRCT and the minimal lumen area (MLA) were evaluated using a dedicated software (cFFR version 3.0.0, Siemens Healthineers, Forchheim, Germany). Obstructive CAD was defined as CTA lumen reduction ≥ 50%, and flow-limiting stenosis as iFFR ≤0.8. All reported P values are two-tailed, and when <0.05, they were considered statistically significant. Results Ninety-three consecutive patients (152 vessels) were included. There was good agreement between FFRCT and iFFR, with minimal FFRCT overestimation (bias: -0.02; limits of agreement:0.14-0.09). Different CT scanners did not modify the association between FFRCT and FFRi (p for interaction=0.73). The performance of FFRCT was significantly superior compared to the visual classification of coronary stenosis (AUC 0.93vs.0.61, p<0.001) and to MLA (AUC 0.93vs.0.75, p<0.001), reducing the number of false-positive cases. The optimal cut-off point for FFRCT using a Youden index was 0.85 (87% Sensitivity, 86% Specificity, 73% PPV, 94% NPV), with a reduction of false-positives. Conclusion Machine learning-based FFRCT using previous generation CT scanners (128 and 256-detector rows) shows good diagnostic performance for the detection of CAD, and can be used to reduce the number of invasive procedures.


Subject(s)
Humans , Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Severity of Illness Index , Artificial Intelligence , Tomography, X-Ray Computed , Predictive Value of Tests , Retrospective Studies , Coronary Angiography , Constriction, Pathologic , Coronary Vessels , Machine Learning , Computed Tomography Angiography
6.
Arq. bras. cardiol ; 115(6): 1051-1060, dez. 2020. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1152934

ABSTRACT

Resumo Fundamento Em regiões endêmicas da doença de Chagas, por muitos anos, existe uma observação empírica recorrente de que a doença arterial coronariana (DAC) é incomum em pacientes com doença de Chagas. Estudos anteriores baseados em análise patológica ou angiografia coronária invasiva apresentam resultados controversos. Objetivo Investigar se a DAC é menos prevalente e menos grave em pacientes com doença de Chagas crônica em comparação a uma população pareada controle, com perfil de risco para DAC similar. Métodos Um total de 86 participantes, 43 pacientes com doença de Chagas crônica consecutivos e 43 indivíduos assintomáticos, sem qualquer história prévia de doença cardíaca ou doença DAC conhecida (grupo controle), foram incluídos no estudo. Pacientes e controles foram pareados quanto sexo, idade e escore de risco de Framingham. Todos os pacientes foram analisados quanto ao escore de cálcio coronário (ECC) e submetidos à angiotomografia coronária usando um tomógrafo de 320 detectores. O nível de significância estatística adotado foi de p < 0,05. Resultados O ECC foi significativamente mais baixo em pacientes com doença de Chagas em comparação aos controles (p<0,05). A presença de placas ateroscleróticas coronárias foi significativamente menos frequente em pacientes com doença de Chagas que nos controles (20,9% versus 41,9%, p=0,037). Após ajuste quanto ao escore de Framingham, o odds ratio para a presença de qualquer calcificação coronária foi de 0,26 (IC95%: 0,07-0,99, p=0,048). O padrão é similar para escore de cálcio coronário (ECC) > 10 (OR: 0,11, IC95%: 0,01-0,87, p=0,04), e para a presença de estenose (OR: 0,06, IC95%: 0,01-0,47, p=0,001). O pareamento por escore de propensão também mostrou um efeito da doença de Chagas no ECC (-21,6 pontos no escore absoluto e 25% menos pacientes com ECC > 10; p=0,015). Conclusões A prevalência e a gravidade da DAC são mais baixas nos pacientes com doença de Chagas crônica em comparação a uma população pareada e perfil de risco para DAC similar. (Arq Bras Cardiol. 2020; 115(6):1051-1060)


Abstract Background In Chagas' disease endemic regions, there has been for many years a recurrent empirical observation that coronary artery disease (CAD) is uncommon in patients with Chagas' disease. Previous pathological and invasive coronary angiography studies led to controversial results. Objective We sought to investigate whether CAD is less prevalent and less severe in patients with chronic Chagas' disease when compared with a matched population with a similar CAD risk profile. Methods A total of 86 participants, 43 consecutive patients with chronic Chagas' disease and 43 asymptomatic individuals, without any prior history of cardiac disease or known CAD (control group), were included. Patients and controls were matched according to gender, age, and Framingham risk score. All participants underwent coronary calcium scoring and coronary computed tomography angiography on a 320-row detector scanner. Statistical significance level adopted was p < 0.05. Results The coronary artery calcium score (CACS) was significantly lower in patients with Chagas' disease than in controls (p<0.05). The presence of coronary atherosclerotic plaques was significantly less frequent in patients with Chagas' disease than in controls (20.9% versus 41.9%, p=0.037). After adjustment for the Framingham score, the odds ratio for the presence of any coronary artery calcium (CAC) in Chagas patients was 0.26 (95%CI: 0.07-0.99, p=0.048). The pattern is similar for CACS > 10 (OR: 0.11, 95%CI: 0.01-0.87, p=0.04) and for the presence of any stenosis (OR: 0.06, 95%CI: 0.01-0.47, p=0.001). Propensity score matching also indicated an effect of Chagas disease on the CACS (-21.6 points in the absolute score and 25% less of patients with CACS >10, p=0.015). Conclusions CAD is less prevalent and less severe in patients with chronic Chagas' disease when compared with a matched population with a similar CAD risk profile. (Arq Bras Cardiol. 2020; 115(6):1051-1060)


Subject(s)
Humans , Coronary Artery Disease/etiology , Coronary Artery Disease/epidemiology , Coronary Artery Disease/diagnostic imaging , Chagas Disease/complications , Chagas Disease/epidemiology , Chagas Disease/diagnostic imaging , Prevalence , Predictive Value of Tests , Risk Factors , Coronary Angiography , Computed Tomography Angiography
7.
Arq Bras Cardiol ; 115(6): 1051-1060, 2020 12.
Article in English, Portuguese | MEDLINE | ID: mdl-33470300

ABSTRACT

BACKGROUND: In Chagas' disease endemic regions, there has been for many years a recurrent empirical observation that coronary artery disease (CAD) is uncommon in patients with Chagas' disease. Previous pathological and invasive coronary angiography studies led to controversial results. OBJECTIVE: We sought to investigate whether CAD is less prevalent and less severe in patients with chronic Chagas' disease when compared with a matched population with a similar CAD risk profile. METHODS: A total of 86 participants, 43 consecutive patients with chronic Chagas' disease and 43 asymptomatic individuals, without any prior history of cardiac disease or known CAD (control group), were included. Patients and controls were matched according to gender, age, and Framingham risk score. All participants underwent coronary calcium scoring and coronary computed tomography angiography on a 320-row detector scanner. Statistical significance level adopted was p < 0.05. RESULTS: The coronary artery calcium score (CACS) was significantly lower in patients with Chagas' disease than in controls (p<0.05). The presence of coronary atherosclerotic plaques was significantly less frequent in patients with Chagas' disease than in controls (20.9% versus 41.9%, p=0.037). After adjustment for the Framingham score, the odds ratio for the presence of any coronary artery calcium (CAC) in Chagas patients was 0.26 (95%CI: 0.07-0.99, p=0.048). The pattern is similar for CACS > 10 (OR: 0.11, 95%CI: 0.01-0.87, p=0.04) and for the presence of any stenosis (OR: 0.06, 95%CI: 0.01-0.47, p=0.001). Propensity score matching also indicated an effect of Chagas disease on the CACS (-21.6 points in the absolute score and 25% less of patients with CACS >10, p=0.015). CONCLUSIONS: CAD is less prevalent and less severe in patients with chronic Chagas' disease when compared with a matched population with a similar CAD risk profile. (Arq Bras Cardiol. 2020; 115(6):1051-1060).


FUNDAMENTO: Em regiões endêmicas da doença de Chagas, por muitos anos, existe uma observação empírica recorrente de que a doença arterial coronariana (DAC) é incomum em pacientes com doença de Chagas. Estudos anteriores baseados em análise patológica ou angiografia coronária invasiva apresentam resultados controversos. OBJETIVO: Investigar se a DAC é menos prevalente e menos grave em pacientes com doença de Chagas crônica em comparação a uma população pareada controle, com perfil de risco para DAC similar. MÉTODOS: Um total de 86 participantes, 43 pacientes com doença de Chagas crônica consecutivos e 43 indivíduos assintomáticos, sem qualquer história prévia de doença cardíaca ou doença DAC conhecida (grupo controle), foram incluídos no estudo. Pacientes e controles foram pareados quanto sexo, idade e escore de risco de Framingham. Todos os pacientes foram analisados quanto ao escore de cálcio coronário (ECC) e submetidos à angiotomografia coronária usando um tomógrafo de 320 detectores. O nível de significância estatística adotado foi de p < 0,05. RESULTADOS: O ECC foi significativamente mais baixo em pacientes com doença de Chagas em comparação aos controles (p<0,05). A presença de placas ateroscleróticas coronárias foi significativamente menos frequente em pacientes com doença de Chagas que nos controles (20,9% versus 41,9%, p=0,037). Após ajuste quanto ao escore de Framingham, o odds ratio para a presença de qualquer calcificação coronária foi de 0,26 (IC95%: 0,07-0,99, p=0,048). O padrão é similar para escore de cálcio coronário (ECC) > 10 (OR: 0,11, IC95%: 0,01-0,87, p=0,04), e para a presença de estenose (OR: 0,06, IC95%: 0,01-0,47, p=0,001). O pareamento por escore de propensão também mostrou um efeito da doença de Chagas no ECC (-21,6 pontos no escore absoluto e 25% menos pacientes com ECC > 10; p=0,015). CONCLUSÕES: A prevalência e a gravidade da DAC são mais baixas nos pacientes com doença de Chagas crônica em comparação a uma população pareada e perfil de risco para DAC similar. (Arq Bras Cardiol. 2020; 115(6):1051-1060).


Subject(s)
Chagas Disease , Coronary Artery Disease , Chagas Disease/complications , Chagas Disease/diagnostic imaging , Chagas Disease/epidemiology , Computed Tomography Angiography , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/epidemiology , Coronary Artery Disease/etiology , Humans , Predictive Value of Tests , Prevalence , Risk Factors
9.
Eur Radiol ; 28(6): 2665-2674, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29352381

ABSTRACT

OBJECTIVES: Despite advances in non-invasive myocardial perfusion imaging (MPI) evaluation, computed tomography (CT) multiphase MPI protocols have not yet been compared with the highly accurate rubidium-82 positron emission tomography (82RbPET) MPI. Thus, this study aimed to evaluate agreement between 82RbPET and 320-detector row CT (320-CT) MPI using a multiphase protocol in suspected CAD patients. METHODS: Forty-four patients referred for MPI evaluation were prospectively enrolled and underwent dipyridamole stress 82RbPET and multiphase 320-CT MPI (five consecutive volumetric acquisitions during stress). Statistical analyses were performed using the R software. RESULTS: There was high agreement for recognizing summed stress scores ≥ 4 (kappa 0.77, 95% CI 0.55-0.98, p < 0.001) and moderate for detecting SDS ≥ 2 (kappa 0.51, 95% CI 0.23-0.80, p < 0.001). In a per segment analysis, agreement was high for the presence of perfusion defects during stress and rest (kappa 0.75 and 0.82, respectively) and was moderate for impairment severity (kappa 0.58 and 0.65, respectively). The 320-CT protocol was safe, with low radiation burden (9.3 ± 2.4 mSv). CONCLUSIONS: There was a significant agreement between dipyridamole stress 320-CT MPI and 82RbPET MPI in the evaluation of suspected CAD patients of intermediate risk. The multiphase 320-CT MPI protocol was feasible, diagnostic and with relatively low radiation exposure. KEY POINTS: • Rubidium-82 PET and 320-MDCT can perform MPI studies for CAD investigation. • There is high agreement between rubidium-82 PET and 320-MDCT for MPI assessment. • Multiphase CT perfusion protocols are feasible and with low radiation. • Multiphase CT perfusion protocols can identify image artefacts.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Radiopharmaceuticals , Rubidium Radioisotopes , Computed Tomography Angiography , Coronary Vessels/diagnostic imaging , Dipyridamole/pharmacology , Female , Humans , Male , Middle Aged , Multidetector Computed Tomography , Myocardial Perfusion Imaging/methods , Positron-Emission Tomography/methods , Prospective Studies , Software , Tomography, Emission-Computed, Single-Photon/methods , Vasodilator Agents/pharmacology
10.
Knee Surg Sports Traumatol Arthrosc ; 25(10): 3197-3205, 2017 Oct.
Article in English | MEDLINE | ID: mdl-27544273

ABSTRACT

PURPOSE: Medial patellofemoral ligament (MPFL) reconstruction offers good clinical results with a very low rate of instability recurrence. However, its in vivo effect on patellar tracking is not clearly known. The aim of this study is to investigate the effects of MPFL reconstruction on patellar tracking using dynamic 320-detector-row CT. METHODS: Ten patients with patellofemoral instability referred to isolated MPFL reconstruction surgery were selected and subjected to dynamic CT before and ≥6 months after surgery. Patellar tilt angles and shift distance were analysed using computer software specifically designed for this purpose. Kujala and Tegner scores were applied, and the radiation of the CTs was recorded. Two protocols for imaging acquisition were compared: a tube potential of 80 kV and 50 mA versus a tube potential of 120 kV and 100 mA, both with a slice thickness of 0.5 mm and an acquisition duration of 10 s. RESULTS: There were no changes in patellar tracking after MPFL reconstruction. There was no instability relapse. Clinical scores improved from a mean of 51.9 (±15.6)-74.2 (±20.9) on the Kujala scale (p = 0.011) and from a median of 2 (range 0-4) to 4 (range 1-6) on the Tegner scale (p = 0.017). The imaging protocols produced a dose-length product (DLP) of 254 versus 1617 mGycm and a radiation effective estimated dose of 0.2 versus 1.3 mSv, respectively. Both protocols allowed the analysis of the studied parameters without loss of precision. CONCLUSIONS: Reconstruction of the MPFL produced no improvement in patellar tilt or shift in the population studied. The low-radiation protocol was equally effective in measuring changes in patellar tracking and is recommended. Although the procedure successfully stabilized the patella, knee surgeons should not expect patellar shift and tilt correction when performing isolated patellofemoral ligament reconstruction in patients with recurrent patellar instability. LEVEL OF EVIDENCE: IV.


Subject(s)
Joint Instability/surgery , Ligaments, Articular/surgery , Multidetector Computed Tomography , Patella/diagnostic imaging , Patella/physiopathology , Patellar Dislocation/surgery , Patellofemoral Joint/surgery , Adolescent , Adult , Female , Follow-Up Studies , Humans , Joint Instability/diagnostic imaging , Joint Instability/physiopathology , Ligaments, Articular/physiopathology , Male , Orthopedic Procedures , Patella/surgery , Patellar Dislocation/diagnostic imaging , Patellar Dislocation/physiopathology , Patellofemoral Joint/diagnostic imaging , Patellofemoral Joint/physiopathology , Plastic Surgery Procedures , Recurrence , Treatment Outcome , Young Adult
11.
Arq. bras. cardiol ; 105(6): 614-624, Dec. 2015. tab, graf
Article in Portuguese | LILACS | ID: lil-769542

ABSTRACT

Abstract Background: Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). Objective: To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and compare the results with those of single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy. Methods: Thirty patients with LBBB who had undergone SPECT for the investigation of coronary artery disease were referred for stress tomography. Independent examiners performed per-patient and per-coronary territory assessments. All patients gave written informed consent to participate in the study that was approved by the institution’s ethics committee. Results: The patients’ mean age was 62 ± 10 years. The mean dose of radiation for the tomography protocol was 9.3 ± 4.6 mSv. With regard to CTP, the per-patient values for sensitivity, specificity, positive and negative predictive values, and accuracy were 86%, 81%, 80%, 87%, and 83%, respectively (p = 0.001). The per-territory values were 63%, 86%, 65%, 84%, and 79%, respectively (p < 0.001). In both analyses, the addition of CTP to CTA achieved higher diagnostic accuracy for detecting myocardial ischemia than SPECT (p < 0.001). Conclusion: The use of the stress tomography protocol is feasible and has good diagnostic accuracy for assessing myocardial ischemia in patients with LBBB.


Resumo Fundamentos: Testes funcionais possuem limitada acurácia para identificar isquemia miocárdica em pacientes com bloqueio de ramo esquerdo (BRE). Objetivo: Utilizando tomógrafo com 320 detectores foi avaliado a acurácia diagnóstica da perfusão miocárdica de estresse com dipiridamol pela tomografia (PMT) em pacientes com BRE utilizando a angiografia coronária quantitativa invasiva (QCA) (estenose ≥ 70%) como referência. Procurou-se também investigar o valor adicional da PMT sobre a angiotomografia coronariana (ATC) comparando a acurácia com a cintilografia perfusional miocárdica (SPECT). Métodos: Trinta pacientes com BRE e SPECT prévio em investigação de doença arterial coronariana foram encaminhados para realização do protocolo de estresse na tomografia. Observadores independentes realizaram avaliação por paciente e por território coronariano. Todos os pacientes assinaram um termo de consentimento livre e esclarecido aprovado pelo Comitê de Ética da Instituição. Resultados: A média de idade foi 62 ± 10 anos. A dose média de radiação do protocolo de tomografia foi 9,3 ± 4,6 mSv. Em relação a PMT, na análise por paciente, a sensibilidade, especificidade, valores preditivos positivos e negativos e acurácia foram, respectivamente, 86%, 81%, 80%, 87%, 83% p = 0,001. Na análise por território os valores foram, respectivamente, 63%, 86% a 65%, 84%, 79% p < 0,001. Em ambas as análises, a adição da PMT a ATC determinou maior acurácia diagnóstica para detecção de isquemia miocárdica quando comparado com o SPECT (p < 0,001). Conclusão: O uso do protocolo de estresse na tomografia é viável e tem boa acurácia diagnóstica na pesquisa de isquemia miocárdica nos pacientes com BRE.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Bundle-Branch Block , Coronary Artery Disease , Dipyridamole , Myocardial Perfusion Imaging/methods , Tomography, Emission-Computed, Single-Photon/methods , Vasodilator Agents , Bundle-Branch Block , Coronary Angiography/methods , Coronary Artery Disease , Multidetector Computed Tomography/instrumentation , Prospective Studies , Radiation Exposure , Reproducibility of Results , Risk Factors , Sensitivity and Specificity , Time Factors
12.
Arq Bras Cardiol ; 105(6): 614-24, 2015 Dec.
Article in English, Portuguese | MEDLINE | ID: mdl-26421532

ABSTRACT

BACKGROUND: Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). OBJECTIVE: To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and compare the results with those of single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy. METHODS: Thirty patients with LBBB who had undergone SPECT for the investigation of coronary artery disease were referred for stress tomography. Independent examiners performed per-patient and per-coronary territory assessments. All patients gave written informed consent to participate in the study that was approved by the institution's ethics committee. RESULTS: The patients' mean age was 62 ± 10 years. The mean dose of radiation for the tomography protocol was 9.3 ± 4.6 mSv. With regard to CTP, the per-patient values for sensitivity, specificity, positive and negative predictive values, and accuracy were 86%, 81%, 80%, 87%, and 83%, respectively (p = 0.001). The per-territory values were 63%, 86%, 65%, 84%, and 79%, respectively (p < 0.001). In both analyses, the addition of CTP to CTA achieved higher diagnostic accuracy for detecting myocardial ischemia than SPECT (p < 0.001). CONCLUSION: The use of the stress tomography protocol is feasible and has good diagnostic accuracy for assessing myocardial ischemia in patients with LBBB.


Subject(s)
Bundle-Branch Block/diagnostic imaging , Coronary Artery Disease/diagnostic imaging , Dipyridamole , Myocardial Perfusion Imaging/methods , Tomography, Emission-Computed, Single-Photon/methods , Vasodilator Agents , Aged , Coronary Angiography/methods , Female , Humans , Male , Middle Aged , Multidetector Computed Tomography/instrumentation , Prospective Studies , Radiation Exposure , Reproducibility of Results , Risk Factors , Sensitivity and Specificity , Time Factors
13.
Rev. bras. cardiol. invasiva ; 23(2): 130-133, abr.-jun. 2015. tab, graf
Article in Portuguese | LILACS | ID: lil-786996

ABSTRACT

Introdução: A medida acurada do tamanho do anel valvar aórtico tem importância fundamental para o planejamento do implante percutâneo de prótese valvar aórtica transcateter (TAVI) em pacientes comestenose valvar aórtica grave. Embora haja recomendação de se realizar a medida na sístole, pouco se sabe sobre a importância das diferenças entre as dimensões sistólica e diastólica do anel. Métodos: Pacientes consecutivos referidos para TAVI foram avaliados com tomografia computadorizada para medida do anel valvar na sístole e na diástole. Área, circunferência, diâmetros máximo e mínimo, e seus diâmetros médios derivados foram obtidos em ambas as fases do ciclo cardíaco. Gráficos de Bland Altman foram construídos para se avaliarem as diferenças entre as medidas.Resultados: Foram incluídos na análise 41 pacientes com estenose aórtica grave. As médias da área, circunferência e diâmetros médios foram discretamente maiores na sístole. No entanto, em 35% dos pacientes, as dimensões diastólicas foram maiores. Essas diferenças, embora estatisticamente significantes, foram pequenas (a maior diferença de 0,6 mm no diâmetro médio). Gráficos de Bland Altman revelaram bons níveis de concordância entre as medidas sistólicas e diastólicas em todos os parâmetros avaliados.Conclusões: Observamos pequenas diferenças nas dimensões sistólicas e diastólicas no anel valvar aórtico à tomografia computadorizada, as quais, embora estatisticamente significantes, provavelmente não impactam na seleção da prótese e nem no resultado do procedimento.


Background: Accurate aortic valve annulus sizing has critical importance for the planning of percutaneous transcatheter aortic valve implantation (TAVI) in patients with severe aortic valve stenosis. Although there is a recommendation to perform the measurement during systole, little is known about the importance of the differences between systolic and diastolic dimensions of the annulus. Methods: Consecutive patients referred for TAVI were evaluated with computed tomography for valve annulus sizing during systole and diastole. Area, circumference, minimum and maximum diameters, and their mean derived diameters were obtained in both phases of the cardiac cycle. Bland-Altman plots were constructed to evaluate the differences between the measures. Results: The analysis included 41 patients with severe aortic stenosis. Mean area, circumference, and diameters were slightly greater in systole. However, in 35% of patients, diastolic dimensions were greater.These differences, although statistically significant, were small (the greatest difference of 0.6 mm in mean diameter). Bland-Altman plots showed good agreement between systolic and diastolic measurements on all parameters evaluated Conclusions: Small differences were observed in the systolic and diastolic dimensions of the aortic valve annulus with computed tomography scan, which, although statistically significant, probably do not impact the selection of prosthesis or the procedure outcome.


Subject(s)
Humans , Male , Female , Aged, 80 and over , Diastole/physiology , Transcatheter Aortic Valve Replacement/methods , Systole/physiology , Tomography, X-Ray Computed/methods , Data Interpretation, Statistical , Femoral Artery/surgery , Echocardiography/methods , Aortic Valve Stenosis/therapy , Prostheses and Implants
14.
Ann Noninvasive Electrocardiol ; 20(5): 498-501, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25367861

ABSTRACT

A woman (49 years) with Chagas' disease showed: ECG, right bundle-branch block and left anterior-superior fascicular block; V1 has unusual R > R', and elevated ST segment from V2 to V6 . Additional imaging revealed concomitant HCM and Chagas, which is uncommon. Overlapping of ECG findings can be explained by this rare association of diseases.


Subject(s)
Cardiomyopathy, Hypertrophic/complications , Chagas Cardiomyopathy/complications , Electrocardiography , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/etiology , Brugada Syndrome , Cardiac Conduction System Disease , Female , Heart Conduction System/abnormalities , Humans , Middle Aged
15.
Arq. bras. cardiol ; 103(6,supl.3): 1-86, 12/2014. tab
Article in Portuguese | LILACS | ID: lil-732178
16.
Arq Bras Cardiol ; 103(6 Suppl 3): 1-86, 2014 Dec.
Article in Portuguese | MEDLINE | ID: mdl-25594284
17.
BMC Cardiovasc Disord ; 12: 65, 2012 Aug 16.
Article in English | MEDLINE | ID: mdl-22898311

ABSTRACT

BACKGROUND: Although the release of cardiac biomarkers after percutaneous (PCI) or surgical revascularization (CABG) is common, its prognostic significance is not known. Questions remain about the mechanisms and degree of correlation between the release, the volume of myocardial tissue loss, and the long-term significance. Delayed-enhancement of cardiac magnetic resonance (CMR) consistently quantifies areas of irreversible myocardial injury. To investigate the quantitative relationship between irreversible injury and cardiac biomarkers, we will evaluate the extent of irreversible injury in patients undergoing PCI and CABG and relate it to postprocedural modifications in cardiac biomarkers and long-term prognosis. METHODS/DESIGN: The study will include 150 patients with multivessel coronary artery disease (CAD) with left ventricle ejection fraction (LVEF) and a formal indication for CABG; 50 patients will undergo CABG with cardiopulmonary bypass (CPB); 50 patients with the same arterial and ventricular condition indicated for myocardial revascularization will undergo CABG without CPB; and another 50 patients with CAD and preserved ventricular function will undergo PCI using stents. All patients will undergo CMR before and after surgery or PCI. We will also evaluate the release of cardiac markers of necrosis immediately before and after each procedure. Primary outcome considered is overall death in a 5-year follow-up. Secondary outcomes are levels of CK-MB isoenzyme and I-Troponin in association with presence of myocardial fibrosis and systolic left ventricle dysfunction assessed by CMR. DISCUSSION: The MASS-V Trial aims to establish reliable values for parameters of enzyme markers of myocardial necrosis in the absence of manifest myocardial infarction after mechanical interventions. The establishments of these indices have diagnostic value and clinical prognosis and therefore require relevant and different therapeutic measures. In daily practice, the inappropriate use of these necrosis markers has led to misdiagnosis and therefore wrong treatment. The appearance of a more sensitive tool such as CMR provides an unprecedented diagnostic accuracy of myocardial damage when correlated with necrosis enzyme markers. We aim to correlate laboratory data with imaging, thereby establishing more refined data on the presence or absence of irreversible myocardial injury after the procedure, either percutaneous or surgical, and this, with or without the use of cardiopulmonary bypass.


Subject(s)
Coronary Artery Bypass/adverse effects , Coronary Artery Disease/therapy , Creatine Kinase, MB Form/blood , Heart Diseases/diagnosis , Magnetic Resonance Imaging, Cine , Myocardium , Percutaneous Coronary Intervention/adverse effects , Research Design , Troponin I/blood , Biomarkers/blood , Chi-Square Distribution , Coronary Artery Bypass, Off-Pump/adverse effects , Coronary Artery Disease/blood , Coronary Artery Disease/pathology , Coronary Artery Disease/surgery , Fibrosis , Heart Diseases/blood , Heart Diseases/pathology , Heart Diseases/physiopathology , Humans , Logistic Models , Multivariate Analysis , Myocardium/metabolism , Myocardium/pathology , Necrosis , Percutaneous Coronary Intervention/instrumentation , Predictive Value of Tests , Prospective Studies , Stents , Stroke Volume , Time Factors , Treatment Outcome , Up-Regulation , Ventricular Dysfunction, Left/diagnosis , Ventricular Dysfunction, Left/etiology , Ventricular Dysfunction, Left/physiopathology , Ventricular Function, Left
18.
Arq Bras Cardiol ; 98(3): e54-8, 2012 Mar.
Article in English, Portuguese, Spanish | MEDLINE | ID: mdl-22527021

ABSTRACT

We report a dual-source computed tomography study of dynamic and quantitative myocardial perfusion in a 44-year-old patient with previous documented coronary artery disease. Quantitatively, the tomography showed myocardial perfusion deficit in the territories with significant coronary stenosis, confirmed by computed tomography angiography and conventional angiography. Dual-source computed tomography allowed dynamic perfusion and anatomic evaluation in a single study during the follow-up of this patient.


Subject(s)
Coronary Stenosis/diagnostic imaging , Myocardial Ischemia/diagnostic imaging , Myocardial Perfusion Imaging/methods , Tomography, X-Ray Computed/methods , Adult , Dipyridamole , Humans , Male , Radiopharmaceuticals , Tissue Survival/physiology
19.
Arq. bras. cardiol ; 98(3): 54-58, mar. 2012. ilus, graf
Article in Portuguese | LILACS | ID: lil-622527

ABSTRACT

Relatamos caso de perfusão dinâmica e quantitativa pela tomografia computadorizada de múltiplos detectores de dupla fonte de Raio X em um paciente de 44 anos, com diagnóstico prévio de doença coronariana. A tomografia demonstrou quantitativamente déficit de perfusão miocárdica nos territórios irrigados por artérias com estenoses significativas confirmadas pela angiotomografia e pela cineangiocoronariografia. A tomografia computadorizada com dupla fonte de Raio X permitiu a avaliação dinâmica perfusional e anatômica, em um único estudo, durante o controle evolutivo desse paciente.


We report a dual-source computed tomography study of dynamic and quantitative myocardial perfusion in a 44-year-old patient with previous documented coronary artery disease. Quantitatively, the tomography showed myocardial perfusion deficit in the territories with significant coronary stenosis, confirmed by computed tomography angiography and conventional angiography. Dual-source computed tomography allowed dynamic perfusion and anatomic evaluation in a single study during the follow-up of this patient.


Relatamos un caso de perfusión dinámica y cuantitativa por la tomografía computarizada de múltiples detectores de doble fuente de Rayos X, en un paciente de 44 años, con diagnóstico previo de enfermedad coronaria. La tomografía demostró cuantitativamente, un déficit de perfusión miocárdica en los territorios irrigados por arterias con estenosis significativas confirmadas por la angiotomografía y por la cineangiocoronariografía. La tomografía computarizada con doble fuente de Rayos X, permitió la evaluación dinámica de la perfusión y de la anatomía en un único estudio y durante el control evolutivo de ese paciente.


Subject(s)
Adult , Humans , Male , Coronary Stenosis , Myocardial Ischemia , Myocardial Perfusion Imaging/methods , Tomography, X-Ray Computed/methods , Dipyridamole , Radiopharmaceuticals , Tissue Survival/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...