Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Biochem Med (Zagreb) ; 34(2): 020701, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38665874

ABSTRACT

Introduction: This study aimed to investigate the effects of lipemia on clinical chemistry and coagulation parameters in native ultralipemic (NULM) and intravenous lipid emulsion (IVLE) spiked samples. Materials and methods: The evaluation of biochemistry (photometric, ion-selective electrode, immunoturbidimetric method), cardiac (electrochemiluminescence immunoassay method) and coagulation (the viscosity-based mechanical method for prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen and the immunoturbidimetric method for D-dimer) parameters were conducted. In addition to the main pools, five pools were prepared for both types of lipemia, each with triglyceride (TG) concentrations of approximately 2.8, 5.7, 11.3, 17.0 and 22.6 mmol/L. All parameters' mean differences (MD%) were presented as interferographs and compared with the desirable specification for the inaccuracy (bias%). Data were also evaluated by repeated measures of ANOVA. Results: Prothrombin time and APTT showed no clinically relevant interference in IVLE-added pools but were negatively affected in NULM pools(P < 0.001 in both parameters). For biochemistry, the most striking difference was seen for CRP; it is up to 134 MD% value with NULM (P < 0.001) at the highest TG concentration, whereas it was up to - 2.49 MD% value with IVLE (P = 0.009). Albumin was affected negatively upward of 5.7 mmol/L TG with IVLE, while there was no effect for NULM. Creatinine displayed significant positive interferences with NULM starting at the lowest TG concentration (P = 0.028). There was no clinically relevant interference in cardiac markers for both lipemia types. Conclusions: Significant differences were scrutinized in interference patterns of lipemia types, emphasizing the need for careful consideration of lipemia interferences in clinical laboratories. It is crucial to note that lipid emulsions inadequately replicate lipemic samples.


Subject(s)
Fat Emulsions, Intravenous , Hyperlipidemias , Prothrombin Time , Humans , Hyperlipidemias/blood , Fat Emulsions, Intravenous/chemistry , Partial Thromboplastin Time , Triglycerides/blood , Blood Coagulation
2.
Clin Chem Lab Med ; 61(6): 1054-1064, 2023 05 25.
Article in English | MEDLINE | ID: mdl-36583398

ABSTRACT

OBJECTIVES: This study aims to investigate the effect of natural ultralipemic material (NULM) and intravenous lipid emulsion (IVLE) on capillary serum protein electrophoresis (SPEP). METHODS: NULM material was prepared from leftover patients' lipemic serum sample (triglyceride concentration >2,000 mg/dL) pool by a refrigerated high-speed centrifuge, and IVLE Omegaven lipid emulsion (30%) was used. Serum pools for interference study were prepared from patient samples for which serum protein electrophoresis was studied as Normal SPEP and M Peak SPEP. For both types of lipemia (DULM and IVLE), five pools with triglyceride concentrations of ∼4.52 mmol/L, ∼7.91 mmol/L, ∼14.69 mmol/L, ∼21.47 mmol/L, and ∼28.25 mmol/L were prepared. SPEP was studied in each pool with Sebia Capillarys Minicap. A repeated measure ANOVA test was used to determine the difference between the pools, and interferograms were used to evaluate the interference effect. RESULTS: Interference was not detected in IVLE added Normal SPEP and M Peak SPEP pools, either % or concentrations of fractions. In NULM-added Normal SPEP and M Peak SPEP pools, significant positive interference in albumin % (p=0.002 and p<0.001 respectively) and significant negative interference in gamma% (p<0.001 and p=0.005 respectively) and M protein peak (p=0.002) fractions were detected. However, significant positive interference was seen only for albumin concentration fractions (p<0.001 for both pools). CONCLUSIONS: It is vital to use NULM instead of IVLE solutions in lipemia interference studies for all laboratory tests, including CZE SPEP. The fractions concentration values calculated with the total protein concentration should be used for evaluating SPEP results.


Subject(s)
Fat Emulsions, Intravenous , Hyperlipidemias , Humans , Electrophoresis , Triglycerides , Blood Proteins/analysis , Albumins
SELECTION OF CITATIONS