Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Stomatol Oral Maxillofac Surg ; 125(3): 101680, 2023 Nov 10.
Article in English | MEDLINE | ID: mdl-37951501

ABSTRACT

BACKGROUND: Laser application for the treatment of peri­implantitis provides a variety of advantages; however, depending on the laser type and parameters, it may also have adverse effects on the implant surface qualities. This study's objective is to assess the effects of laser type and parameters on the surface properties of two different titanium-based implant materials: titanium Grade 4 (Ti-Grade 4) and titanium zirconium (Ti-Zr) discs with sand-blasted and acid-etched (SLA) surfaces under in vitro conditions. MATERIAL & METHOD: Sand-blasted and acid-etched discs made of titanium grade 4 (Ti-Grade 4) and titanium zirconium (Ti-Zr) were treated using 808 nm AlGaAs (diode) and 2940 nm Er:YAG lasers with varying parameters (i.e., diode laser in continuous wave mode, Er:YAG in short pulse mode, and Er:YAG in variable square pulse mode with four different doses). Then, the surface morphology and topography of the treated discs were characterized using scanning electron microscopy and optical profilometry. RESULTS: The 3D surface topographies of discs treated with a high power Er:YAG laser displayed irregular peaks and deep valleys, indicating surface deterioration. The average surface roughness values (Sa) of both discs varied with laser type and parameters (3.55-4.80 µm for Ti-Grade 4 versus 3.25-4.5 µm for Ti-Zr). With diode laser applications, the topography features of the discs were preserved despite a small number of irregular valleys and peaks. However, the surface morphologies of the discs were dramatically altered by erosion and local melting because of the Er:YAG laser treatment. CONCLUSION: Diode laser application appears to be the most reliable method for treating peri­implantitis, as diode laser-treated implants retained their overall surface quality despite a small number of irregular peaks and valleys.

2.
Colloids Surf B Biointerfaces ; 169: 176-182, 2018 09 01.
Article in English | MEDLINE | ID: mdl-29772473

ABSTRACT

This study focuses on the optimization of electrophoretic deposition (EPD) and suspension parameters for producing PEEK-hydroxyapatite (HA) coatings with feasible microstructure, adhesion strength, and in-vitro bioactivity. Nanostructured hydroxyapatite (HA) micro-granules were incorporated with PEEK to form PEEK-hydroxyapatite composite coatings via EPD. After EPD, a heat-treatment at 375 °C was applied for densification of the coatings and for enhancing the adhesion between the coatings and the substrates. It was found that both adhesion strength and in-vitro bioactivity of the coatings were dependent on the PEEK and HA relative contents. Thus, increasing the amount of HA improved the bioactivity while decreased the adhesion strength of the coatings. Apatite-like layer formation was observed on coatings with high HA content after incubation for three days in simulated body fluid (SBF). Finally, a deposition mechanism was proposed for the EPD of the PEEK-hydroxyapatite composite system.


Subject(s)
Coated Materials, Biocompatible/chemistry , Durapatite/chemistry , Ketones/chemistry , Nanostructures/chemistry , Polyethylene Glycols/chemistry , Benzophenones , Biomedical Technology , Coated Materials, Biocompatible/chemical synthesis , Durapatite/chemical synthesis , Electrophoresis , Particle Size , Polymers , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...