Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
J Mech Behav Biomed Mater ; 148: 106184, 2023 12.
Article in English | MEDLINE | ID: mdl-37839334

ABSTRACT

PURPOSE: This study investigated the impact of preparation design and material types on fracture strength in maxillary premolars endocrowns after thermodynamic aging. MATERIALS AND METHODS: Eighty two-rooted maxillary premolar crowns underwent endodontic treatment (N = 80, n = 10). The teeth were categorized into ten groups (4-mm deep with no intracanal extension lithium disilicate glass ceramic & multilayer zirconia endocrowns (LE0 & ZE0); 4-mm deep with 4-mm intracanal extension in one canal (LE1 & ZE1); 4-mm deep with 2-mm intracanal extensions in both canals (LE2 & ZE2); flat overlays with no endocore (LO & ZO); glass fiber reinforced post & core and crown (LC & ZC)). After cementation, all specimens were subjected to 1500 thermocycles and 1,200,000 chewing cycles with an axial occlusal load of 49 N. A static loading test was performed at a non-axial 45° loading using a universal testing machine and failure modes (Type I: restoration debonding; Type II: restoration fracture; Type III: restoration/tooth complex fracture above bone level; Type IV: restoration/tooth complex fracture below bone level) were evaluated using a stereoscope. Data were ananalzed using 2-way ANOVA and Tukey's tests (alpha = 0.05). RESULTS: The endocrowns manufactured from multilayered zirconia and pressed lithium disilicate glass ceramic exhibited a fracture load ranging between 1334 ± 332 N and 756 ± 150 N, with ZC presenting the highest and LE2 the lowest values. The differences were not statistically significant (p > 0.05). CONCLUSION: All endocrowns tested in this study performed similar considering the different designs and materials tested. The distribution of fracture modes did not differ significantly depending on the design of the restoration and the type of material used.


Subject(s)
Flexural Strength , Tooth Fractures , Humans , Materials Testing , Computer-Aided Design , Zirconium , Ceramics , Dental Porcelain , Dental Stress Analysis , Dental Restoration Failure
2.
Materials (Basel) ; 16(6)2023 Mar 08.
Article in English | MEDLINE | ID: mdl-36984061

ABSTRACT

The long-term success of ceramic laminate veneers (CLVs) is influenced by the marginal and internal fit of the restorations. However, studies comparing the fit of CLVs using different intraoral scanners or the indirect digitization technique are lacking. The purpose of this study was therefore to assess the marginal and internal fit of CAD/CAM-milled CLVs using different intraoral scanners and the indirect digitalization technique. An ivorine typodont maxillary left-central incisor was prepared; the tooth and the neighboring teeth were scanned and used as a template to print ninety 3D partial models. Thereafter, ceramic laminate veneers (CLVs) (N = 90) were milled from IPS-Emax CAD blocks and divided into six equal groups (15 specimens each) according to the type of intraoral scanner (IOS), as follows: Omnicam IOS, SC3600 IOS, Trios 3 IOS, Emerald IOS, I500 IOS. Fifteen further CLVs were fabricated using the conventional indirect digitalization technique. After cementation on the resin dies and embedding in clear epoxy resin, specimens were sectioned inciso-gingivally and mesio-distally. At the incisal and cervical positions, the marginal discrepancy was measured and evaluated in addition to the internal gap at six locations using SEM (200×). Differences between gap measurements among the six groups were determined using ANOVA. Games-Howell multiple comparisons for homogenous variances and LSD multiple comparisons for non-homogenous variances were used with 95% confidence intervals. The significance level was set at 0.05. The lowest mean absolute marginal gap at the incisal margins (AMGI) was recorded for Omnicam group (203.28 ± 80.14) µm, while the highest mean absolute marginal gap at the cervical margins (AMGC) was recorded for Omnicam group (147.16 ± 59.78) µm. The mean AMGC was reported to be significantly different between the conventional technique (146.75 ± 38.43) µm and Trios 3 (91.86 ± (35.51) µm; p = 0.001) and between Emerald (112.37 ± (50.31) µm; p = 0.042) and I500 (86.95 ± (41.55) µm; p < 0.001). The mean MGI was found to be significantly different between the conventional technique (114.11 ± (43.45) µm and I500 group (186.99 ± (73.84) µm) only (p = 0.035). However, no significant differences were found in the mean MGI between all types of IOSs. The means of AMG and MG were significantly different at incisal or cervical areas between the conventional technique and IOSs and within the scanner groups (p > 0.05). Marginal gaps were higher in the incisal region compared to the cervical region with both the indirect digitization technique and the IOSs. Ceramic laminate veneers (CLVs) fabricated using IOSs produced overall internal and marginal fit adaptation results comparable to CLVs fabricated from the indirect digitalization method, and both techniques produced clinically acceptable results.

3.
J Prosthodont ; 32(1): 40-48, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35119168

ABSTRACT

PURPOSE: To study the surface and mechanical properties of 3D printed denture-base resin materials and compare them with conventional heat-cured polymethylmethacrylate (PMMA). MATERIALS AND METHODS: Three brands of 3D printed denture-base resin materials and one conventional heat-cured PMMA were tested in this study: NextDent 3D printed resin, Dentona 3D printed resin, ASIGA 3D printed resin, and Meliodent conventional PMMA. Sixty specimens (25 × 25 × 3 mm) were fabricated (n=15 per group) to perform the following tests: wettability, surface roughness, and microhardness. One hundred twenty specimens (65 × 10 × 3 mm) were fabricated (n=30 per group) and stored in distilled water at (37 ±1°C) for 7 days. Specimens (N = 15) in each group were subjected to the three-point bending test and impact strength test, employing the Charpy configuration on un-notched specimens. The morphology of the fractured specimens was studied under scanning electron microscope (SEM). Statistical analysis was performed using one-way ANOVA and Tukey-pairwise multiple comparisons with 95% confidence interval. P-values of ≤0.05 were considered significant. RESULTS: The conventional heat-cured specimens demonstrated the highest means of surface roughness (0.23 ± 0.07 µm), Vickers hardness number (18.11 ±0.65) and flexural strength (92.44 ±7.91 MPa), and the lowest mean of contact angle (66.71° ±3.38°). ASIGA group showed the highest mean of contact angle (73.44° ±2.74°) and the lowest mean of surface roughness (0.19 ±0.03 µm). The highest mean of impact strength was recorded in the Dentona group (17.98 ±1.76 kg/m2 ). NextDent specimens showed the lowest means of Vickers hardness number (16.20 ±0.93), flexural strength (74.89 ±8.44 MPa), impact strength (15.20 ±0.69 kg/m2 ), and recorded the highest mean of bending modulus (2,115.80 ±178.95 MPa). CONCLUSIONS: 3D printed resin exhibited noticeable differences in surface and mechanical properties between different brands and with conventional heat-polymerized PMMA.


Subject(s)
Denture Bases , Polymethyl Methacrylate , Materials Testing , Surface Properties , Flexural Strength
4.
J Mech Behav Biomed Mater ; 137: 105547, 2023 01.
Article in English | MEDLINE | ID: mdl-36370641

ABSTRACT

PURPOSE: The purpose of this in-vitro study was to investigate the effect of framework design on fracture resistance and failure modes of cantilever inlay-retained fixed partial dentures (IRFDPs) fabricated from two multilayered monolithic zirconia materials. MATERIALS AND METHODS: Seventy-two natural premolar teeth were prepared as abutments for cantilever IRFDPs using three designs: mesial-occlusal (MO) inlay with short buccal and palatal wings (D1), MO inlay with long palatal wing (D2), MO inlay with long palatal wing and occlusal extension (D3). Full-contoured IRFDPs were fabricated from two monolithic zirconia materials; IPS e.max ZirCAD Prime and Zolid Gen-X. Adhesive surfaces were air-abraded and bonded with MDP-containing resin cement. Specimens were subjected to thermocycling (5-55 °C, 5000 cycles); then, mechanical loading (1.2 × 106 cycles, 49 N). Surviving specimens were loaded until failure in the universal testing machine. All specimens were examined under stereomicroscope, and two samples from each group were evaluated using Scanning Electron Microscope. RESULTS: Mean failure loads were not significantly different between different framework designs or between two materials. However, IPS e.max ZirCAD Prime showed significantly higher failure rate than Zolid Gen-X during dynamic fatigue (p = 0.009). Samples with D1 design showed higher debonding rate, D2 failed mainly by fracture of the palatal wing and debonding, and D3 failed mainly by fracture of the abutment tooth. Debonded restorations showed mainly mixed failures. CONCLUSION: Cantilever IRFDPs with framework designs that maximize adhesion to enamel exhibited promising results. IPS e.max ZirCAD Prime was more susceptible to fractures with the long palatal wing design.


Subject(s)
Denture Design , Zirconium , Ceramics , Denture, Partial, Fixed , Dental Restoration Failure , Dental Stress Analysis , Dental Porcelain , Materials Testing
5.
J Prosthodont ; 31(4): 320-325, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34213056

ABSTRACT

PURPOSE: To evaluate the effect of repetitive milling on the surface roughness of ceramic crowns. MATERIALS AND METHODS: Twenty feldspathic ceramic crowns (VITABLOCS Mark II; Vita Zahnfabrik, Bad Säckingen, Germany) milled with hard milling protocol, and 20 zirconia crowns (5Y-TZP, inCoris TZI; Dentsply Sirona, York, PA) milled with soft milling protocol, using a 5-axis milling machine (inLab MC X5; Dentsply Sirona) were investigated. Atomic force microscopy (SPM SmartSPM™-1000) was used for surface roughness measurements (Ra, RMS). Pearson correlation between bur deterioration percentage as provided by the software of the milling machine and surface roughness was performed with an (r) range between 1 and -1. Trend analysis between the 2-half and among the 4-quarter bur lifetime was performed with linear contrast analysis and partial eta squared (η) for estimate of effect size. Analysis of mean variance between the zirconia and feldspathic ceramic groups was performed with a t-test, with α = 0.05. RESULTS: Correlation analysis showed small correlation for Ra, RMS (r = -0.02, -0.16 for the feldspathic ceramic crowns and r = 0.044, 0.034 for the zirconia crowns), and no significant differences for the 2-half and 4-quarter groups (p > 0.05) for both crown types. Estimate of effect size was rated as medium for the 2-half groups (Ra = 0.420, RMS = 0.395) and large for the 4-quarter groups (RA = 0.22, F = 1.48, RMS = 0.19, F = 1.26) for the feldspathic ceramic crowns, and small effect size for the 2-half groups (Ra = 0.18, RMS = 0.20) and the 4-quarter groups (Ra = 0.035, RMS = 0.037) for the zirconia crowns. There was no significant difference (p = 0.178, F = 0.016. p = 0.088, F = 0.002) between the feldspathic ceramic and zirconia crowns with medium and large effect size (0.45, 0.57) for RA and RMS. CONCLUSIONS: Milling zirconia and feldspathic ceramic crowns had small correlation between bur deterioration and surface roughness when the burs were used within their recommended lifetime. However, hard milled feldspathic ceramic crowns had higher surface roughness than the soft milled zirconia crowns. Bur deterioration had a larger effect on the surface roughness of the feldspathic ceramic crowns than the zirconia crowns.


Subject(s)
Computer-Aided Design , Dental Porcelain , Ceramics , Crowns , Materials Testing , Surface Properties , Zirconium
6.
J Prosthodont ; 29(4): 341-349, 2020 Apr.
Article in English | MEDLINE | ID: mdl-29896904

ABSTRACT

PURPOSE: The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology to the field of removable prosthodontics has recently made it possible to fabricate complete dentures of prepolymerized polymethyl methacrylate (PMMA) blocks, which are claimed to be of better mechanical properties; however, no published reports that have evaluated mechanical properties of CAD/CAM PMMA. The purpose of this study was to compare flexural strength, impact strength, and flexural modulus of two brands of CAD/CAM PMMA and a conventional heat-cured PMMA. MATERIALS AND METHODS: 45 rectangular specimens (65 mm × 10 mm × 3 mm) were fabricated (15 CAD/CAM AvaDent PMMA specimens from AvaDent, 15 CAD/CAM Tizian PMMA specimens from Shütz Dental, 15 conventional Meliodent PMMA specimens from Heraeus Kulzer) and stored in distilled water at (37  ± 1°C) for 7 days. Specimens (N = 15) in each group were subjected to the three-point bending test and impact strength test, employing the Charpy configuration on unnotched specimens. The morphology of the fractured specimens was studied under a scanning electron microscope (SEM). Statistical analysis was performed using one-way ANOVA and Tukey pairwise multiple comparisons with 95% confidence interval. RESULTS: The Schütz Dental specimens showed the highest mean flexural strength (130.67 MPa) and impact strength (29.56 kg/m2 ). The highest mean flexural modulus was recorded in the AvaDent group (2519.6 MPa). The conventional heat-cured group showed the lowest mean flexural strength (93.33 MPa), impact strength (14.756 kg/m2 ), and flexural modulus (2117.2 MPa). Differences in means of flexural properties between AvaDent and Schütz Dental specimens were not statistically significant (p > 0.05). CONCLUSIONS: As CAD/CAM PMMA specimens exhibited improved flexural strength, flexural modulus, and impact strength in comparison to the conventional heat-cured groups, CAD/CAM dentures are expected to be more durable. Different brands of CAD/CAM PMMA may have inherent variations in mechanical properties.


Subject(s)
Hot Temperature , Polymethyl Methacrylate , Computer-Aided Design , Dental Materials , Denture, Complete , Materials Testing , Surface Properties
7.
J Prosthodont ; 28(4): 452-457, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30730086

ABSTRACT

PURPOSE: To compare surface properties of 2 brands of pre-polymerized resin blocks for complete dentures (CAD/CAM PMMA) to conventional heat-polymerized PMMA. MATERIALS AND METHODS: A total of 45 rectangular specimens (25 × 25 × 3 mm) were fabricated from 3 brands of PMMA (n = 15/group): AvaDent CAD/CAM PMMA, Tizian-Schütz CAD/CAM PMMA, Meliodent conventional PMMA. Specimens were examined for wettability using the sessile drop method, surface roughness using a digital contact profilometer, and microhardness using Vickers hardness number. Statistical analysis was performed using one-way ANOVA and Tukey pairwise multiple comparisons. p-Values of ≤0.05 were considered significant. RESULTS: AvaDent specimens demonstrated the highest mean contact angle (72.87 ± 48°) and the highest mean Vickers hardness number (20.62 ± 0.33). The conventional heat-polymerized specimens showed the highest mean surface roughness (0.22 ± 0.071 µm). Tizian-Schütz specimens showed the lowest mean surface roughness (0.12 ± 0.02 µm). CONCLUSIONS: As CAD/CAM PMMA groups exhibited significantly more favorable surface properties in comparison to the conventional heat-polymerized groups, CAD/CAM dentures are expected to be more durable. Different brands of CAD/CAM PMMA may have inherent variations in surface properties.


Subject(s)
Computer-Aided Design , Polymethyl Methacrylate , Denture, Complete , Materials Testing , Surface Properties
8.
J Prosthet Dent ; 121(3): 470-476, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30391059

ABSTRACT

STATEMENT OF PROBLEM: The marginal and internal adaptations of porcelain laminate veneers (PLVs) are key elements in their long-term success. However, the marginal and internal fit obtained with a pressable material compared with computer-aided design and computer-aided manufacturing (CAD-CAM) needs further investigation as does the choice of cement used. PURPOSE: The purpose of this in vitro study was to evaluate the marginal and internal fit of PLVs fabricated using pressing and CAD-CAM milling and cemented using 2 types of composite resin cement. MATERIAL AND METHODS: Twenty PLVs were fabricated from VITA PM9 pressable material, and 20 veneers were milled using VITA Blocs Mark II. Veneers were cemented to composite resin dies using either RelyX Veneer cement or Variolink-N cement. Specimens were embedded in clear resin and sectioned incisogingivally and mesiodistally. Marginal discrepancy at the incisal and cervical positions and the internal gap at 6 different locations were evaluated by using a scanning electron microscope. Two-way ANOVA followed by Tukey multiple comparisons were used to examine difference among groups (α=.05). RESULTS: The cement and fabrication methods did not show any significant effect for absolute marginal gap (AMG) at the incisal edge, AMG at the cervical margin or marginal gap at the incisal edge. However, both had a significant effect on marginal gap at the cervical margin (P=.038 for the fabrication method and P=.050 for the cement used). Also, both cement and fabrication methods had a significant effect on internal gap average (P<.001). The lowest gap values were reported for veneers fabricated from VITA PM9 by using the press technique and cemented with RelyX Veneer cement. When the position of gap measurements was taken into consideration, it was the only significant factor (P<.001 for the effect of position on AMG and P<.001 for the effect of position on marginal gap). Gaps at the cervical position were significantly lower than gaps at the incisal position. CONCLUSIONS: Smaller marginal and internal discrepancies were recorded for PLVs fabricated by using the pressing technique and cemented using RelyX Veneer cement compared with milled veneers and Variolink-N cement. Larger discrepancies were present incisally than cervically.


Subject(s)
Dental Porcelain , Resin Cements , Computer-Aided Design , Dental Marginal Adaptation , Dental Prosthesis Design , Dental Veneers
9.
Quintessence Int ; 48(10): 841-849, 2017.
Article in English | MEDLINE | ID: mdl-28849805

ABSTRACT

OBJECTIVE: To assess possible associations between torus palatinus (TP), torus mandibularis (TM), occlusal force (OF), Klemetti's classes, mandibular cortical index (MCI), and sociodemographic variables in a selected sample of Jordanians. Previous studies have suggested that oral tori are benign anatomical variations probably related to several factors such as functional stress, gender predisposition, number of teeth present, and nutritional factors. METHOD AND MATERIALS: A total of 130 Jordanian adults were included. Shape, location, and appearance of tori were recorded from study casts. Size was measured using digital calipers. OF was recorded in Newtons. MCI and Klemetti's classification were assessed using panoramic radiographs. Data were statistically analyzed, and level of significance was set at P < .05. RESULTS: The mean ± SD recorded OF was 524 ± 183 N in the tori group, compared to 417 ± 172 N in controls (P = .001). OF was significantly higher in males compared to females (P < .001), and was significantly higher in subjects with TM only (543 ± 201 N) (P < .001). TP and TM were predominantly more than 6 mm in size. The average OF in subjects with Klemetti class 3 was 418 ± 174 N, while OF in Klemetti class 1 subjects amounted to 535 ± 187 N (P = .043). CONCLUSION: Average OF was significantly higher in tori subjects and in males (if compared to controls and female subjects, respectively). The presence of oral tori, Klemetti's classification, and MCI ratio seems to be positively correlated with OF.


Subject(s)
Bite Force , Exostoses/epidemiology , Mandibular Diseases/epidemiology , Maxillary Diseases/epidemiology , Adult , Anatomic Variation , Exostoses/diagnostic imaging , Female , Humans , Jordan/epidemiology , Male , Mandibular Diseases/diagnostic imaging , Maxillary Diseases/diagnostic imaging , Middle Aged , Prevalence , Radiography, Panoramic , Sex Factors
10.
Eur J Prosthodont Restor Dent ; 23(3): P141-9, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26591250

ABSTRACT

OBJECTIVES: To evaluate teeth preparation designs for metal-ceramic crowns in private dental practice in Jordan. MATERIALS AND METHODS: One-hundred and seventy two dies were included. Different aspects of tooth preparations were quantified, analyzed and compared with the recommended guidelines. RESULTS: Almost 64% of preparations finish lines were positioned subgingivally. Shoulder finish lines were observed in 74.4% where-as 22.7% showed chamfer finish lines. Total occlusal convergence angles were 29.8 degrees in BL plane, 247 degrees in MD plane. CONCLUSIONS: Dental practitioners in private practice in Jordan did not fully adhere to the recommendedguidelines for tooth preparations for MCRs.


Subject(s)
Crowns , Tooth Preparation, Prosthodontic/standards , Bicuspid/anatomy & histology , Dental Porcelain/chemistry , Dental Prosthesis Design/standards , General Practice, Dental , Gingiva/anatomy & histology , Guideline Adherence , Humans , Metal Ceramic Alloys/chemistry , Models, Dental , Molar/anatomy & histology , Practice Guidelines as Topic , Prosthodontics , Surface Properties
11.
J Prosthet Dent ; 113(3): 198-204, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25444285

ABSTRACT

STATEMENT OF THE PROBLEM: The outline shapes of the dental arch, face, and tooth are esthetic factors used to determine the proper form of artificial teeth when selected for artificial prostheses. PURPOSE: The purpose of this study was to investigate the quantitative relationships between the outlines of the face, the maxillary central incisor, and the maxillary arch by using Fourier analysis. MATERIAL AND METHODS: Frontal facial photographs and irreversible hydrocolloid impressions of the maxilla were obtained from 200 young, dentate individuals (100 men, 100 women) ages 22 to 28 years. On the resultant casts, standardized photographs were made for the dental arch and the maxillary central incisor. The outlines of the face, dental arch, and tooth were digitally traced and the digitized curved outlines were converted into X-Y coordinates with special software, which, in turn, were imported into Fourier Shape Descriptor software for harmonic analysis. The quantitative outputs of Fourier analyses were analyzed and tested with statistical software to investigate the differences across the shapes of the 3 outlines under study. RESULTS: Facial and tooth outlines were similar for each sex, although the similarity was stronger among the men. By contrast, no relationship was found between tooth and maxillary arch outlines or between face and maxillary arch outlines. CONCLUSIONS: Face and tooth forms were quantitatively related. Therefore, face form may reliably guide the selection of artificial anterior tooth form in complete denture prostheses or any complex anterior restorations.


Subject(s)
Dental Arch/anatomy & histology , Face/anatomy & histology , Fourier Analysis , Incisor/anatomy & histology , Maxilla/anatomy & histology , Adult , Cephalometry/statistics & numerical data , Dental Impression Technique/statistics & numerical data , Female , Humans , Image Processing, Computer-Assisted/statistics & numerical data , Jordan , Male , Odontometry/statistics & numerical data , Photography/statistics & numerical data , Young Adult
12.
J Prosthodont ; 23(3): 192-7, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24118594

ABSTRACT

PURPOSE: To assess removable denture patient awareness, expectations, and source of information about dental implants (DIs). MATERIALS AND METHODS: Three hundred patients [150 removable partial denture (RPD) wearers and 150 complete denture wearers (CDWs)] attended the removable prosthodontic clinic at Faculty of Dentistry, Jordan University of Science and Technology. Patients were evaluated using a pilot-tested, 21-question questionnaire. RESULTS: Ninety-six percent of participants were aware of DIs, with no difference between CDWs and RPD wearers (p > 0.05). The participants' friends and relatives were the main source of information (63.4%), followed by dentists (32.4%). Improvement in function was the predominant reason (55.7%) for patients to consider DIs. Fear of unknown side effects was the major factor in preventing patients from choosing DIs (11.7%), followed by high cost (9.7%) and surgical risk (8.7%). Approximately 89% had no information or were poorly informed about DIs. Over two-thirds of patients did not know about the care (78.3%) of DIs, causes of DI failure (69.7%), or DI duration of service (80.7%). Only 24.7% knew that DIs would be anchored to the jawbone; however, 27.3% and 56.7% of CDWs and RPD wearers, respectively, preferred (p < 0.05) to have their teeth replaced with DIs. High costs were considered the major disadvantage of DIs in 45% of participants, followed by fear of surgery (27.3%), and long treatment times (24.7%). CONCLUSIONS: There was a high awareness about DIs among removable denture patients; however, this awareness was associated with a low level of accurate information.


Subject(s)
Attitude to Health , Dental Implants/psychology , Denture, Complete , Denture, Partial, Removable , Health Knowledge, Attitudes, Practice , Adult , Aged , Consumer Health Information , Dental Implants/economics , Dental Restoration Failure , Denture, Complete/psychology , Denture, Partial, Removable/psychology , Educational Status , Employment , Fear/psychology , Female , Health Care Costs , Humans , Income , Male , Middle Aged , Oral Hygiene , Postoperative Complications/psychology , Time Factors , Young Adult
13.
J Prosthet Dent ; 110(3): 216-22, 2013 Sep.
Article in English | MEDLINE | ID: mdl-24029610

ABSTRACT

STATEMENT OF PROBLEM: Fiber posts can fail because of loss of retention; and it is unknown which luting agent provides the highest bond strength. PURPOSE: The purpose of this study was to investigate the tensile bond strength of glass fiber posts luted to premolar teeth with 6 resin composite luting agents. MATERIAL AND METHODS: Ninety-six single-rooted extracted human mandibular premolars were sectioned 2 mm coronal to the most incisal point of the cementoenamel junction. Root canals were instrumented and obturated with laterally condensed gutta percha and root canal sealer (AH26). Gutta percha was removed from the canals to a depth of 8 mm and diameter post spaces with a 1.5 mm were prepared. The specimens were divided into the following 6 groups according to the luting agent used (n=16): Group V, Variolink II; Group A, RelyX ARC; Group N, Multilink N; Group U, RelyX Unicem; Group P, ParaCore; Group F, MultiCore Flow. Each specimen was secured in a universal testing machine and a separating load was applied at a rate of 0.5 mm/min. The forces required to dislodge the posts were recorded. A 1-way analysis of variance (ANOVA) was applied to the mean retentive strengths of various cement materials (α=.05). RESULTS: Significant differences were recorded among the 6 cement types (P<.001). Three materials provided statistically equivalent mean bond strengths (RelyX Unicem, Paracore, and MultiCore Flow) that were significantly greater than for the other 3 materials. CONCLUSIONS: Fiber posts luted with RelyX Unicem, Paracore, and MultiCore Flow demonstrated significantly higher bond strengths.


Subject(s)
Composite Resins/chemistry , Dental Bonding , Dental Materials/chemistry , Glass/chemistry , Post and Core Technique/instrumentation , Resin Cements/chemistry , Bisphenol A-Glycidyl Methacrylate/chemistry , Dental Pulp Cavity/ultrastructure , Dental Stress Analysis/instrumentation , Dentin/ultrastructure , Humans , Materials Testing , Methacrylates/chemistry , Polyethylene Glycols/chemistry , Polymethacrylic Acids/chemistry , Root Canal Preparation/methods , Stress, Mechanical , Tensile Strength
14.
J Dent Educ ; 77(9): 1154-8, 2013 Sep.
Article in English | MEDLINE | ID: mdl-24002853

ABSTRACT

The appropriate convergence angle (CA) for adequate retention and resistance of cast crowns has always been a matter of research and discussion. The purpose of this study was to measure the CA of tooth preparation for single crown (SC) or as abutments for fixed partial denture (FPD) carried out by final-year undergraduate dental students at the College of Dentistry, King Saud University and to compare them with the recommended CA. The convergence angles of 355 tooth preparations were evaluated and grouped into SC preparations and FPD abutment preparations. Dies were scanned using the computer-assisted design (CAD) system (Cercon, Degudent), and snapshots were then taken from buccal and mesial views. CA was calculated from a colored printout for each snapshot using a protractor. The overall mean CA was 18.56°. Only 32.7 percent of the preparations were within the recommended CA (<12°). The mean CA of SC (17.7°) was less than the mean CA for FPD abutment preparations (19.58°). The mean CA for anterior tooth preparations (15.8°) was significantly less than the mean CA for posterior tooth preparations (20.3°). The mean CA for mesio-distal axial wall preparations (16.66°) was less than the mean CA for the buccolingual axial wall preparations (20.45°). A wide range was found for the convergence of the axial walls among dental students. The recommended CA (<12°) was difficult to achieve clinically by these students.


Subject(s)
Crowns , Education, Dental/methods , Prosthodontics/education , Tooth Preparation, Prosthodontic , Tooth/anatomy & histology , Dental Abutments , Dental Prosthesis Design , Denture, Partial, Fixed , Humans , Saudi Arabia , Schools, Dental , Students, Dental
15.
J Prosthodont Res ; 56(4): 272-80, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22841909

ABSTRACT

PURPOSE: Candida-associated denture stomatitis is the most prevalent form of oral candidosis affecting 65% of denture wearers. Failure of therapy and recurrence of infection are not uncommon and the continuous use of antifungal agents may affect the surface properties of the denture material and may contribute to Candida adhesion. This study aimed to investigate surface properties of poly(methyl methacrylate) PMMA denture material before and after exposure to antifungal agents and its relation to in vitro adhesion of Candida albicans. METHODS: Four groups of acrylic specimens (20 mm × 20 mm × 2.5mm) were prepared (25 specimens in each group). Specimens were immersed in nystatin (group 1), fluconazole (group 2), distilled water (group 3) and group 4 was not exposed. Specimens were tested for surface roughness, contact angle, surface hardness and in vitro Candida adherence to PMMA. RESULTS: The results showed that nystatin had no statistically significant effect on surface hardness (P>0.05), but had a statistically significant effect on surface roughness, contact angle, and Candida adhesion to PMMA (P<0.05). On the other hand, fluconazole had no statistically significant effect on surface hardness or roughness (P>0.05), but had a statistically significant effect on contact angle, and Candida adhesion to PMMA (P<0.05). Distilled water had no statistically significant effect on surface hardness, roughness, contact angle, or Candida adhesion to PMMA (P>0.05). CONCLUSIONS: Exposure of PMMA to nystatin may induce changes in roughness, wettability while exposure to fluconazole may affect surface free energy and therefore may increase Candida adhesion to it.


Subject(s)
Antifungal Agents/pharmacology , Candida albicans/drug effects , Polymethyl Methacrylate , Fluconazole/pharmacology , Nystatin/pharmacology , Surface Properties/drug effects
16.
Int J Prosthodont ; 23(6): 541-3, 2010.
Article in English | MEDLINE | ID: mdl-21209990

ABSTRACT

This study considered the need and demand for complete dentures in a select group of 600 Jordanian adults and the relationship between complete edentulism and sociodemographic variables by means of a pilot-tested questionnaire. Both maxillary and mandibular dentures were fabricated for 505 subjects, while 95 needed complete dentures in only one arch. Significantly more men than women requested complete dentures. Approximately 80% (28 of 35) of subjects who required replacement dentures for esthetic reasons were women, while over 85% (18 of 21) of subjects who required a spare set of dentures were men. The findings suggest a significant relationship between sociodemographic variables and edentulism, with age, education level, and socioeconomic status playing vital roles in edentulism and denture demand.


Subject(s)
Mouth, Edentulous/epidemiology , Adult , Age Factors , Aged , Aged, 80 and over , Attitude to Health , Dental Care/statistics & numerical data , Denture, Complete, Lower/statistics & numerical data , Denture, Complete, Upper/statistics & numerical data , Educational Status , Esthetics, Dental , Female , Health Behavior , Health Services Needs and Demand/statistics & numerical data , Humans , Income , Jordan/epidemiology , Male , Middle Aged , Pilot Projects , Sex Factors , Smoking/epidemiology , Social Class , Socioeconomic Factors , Surveys and Questionnaires , Time Factors
17.
J Oral Implantol ; 35(4): 210-4, 2009.
Article in English | MEDLINE | ID: mdl-19813428

ABSTRACT

The widespread use of endosseous osseointegrated implants to replace missing natural teeth increases the chances of implant complications and failures, despite the high initial success rate reported in the literature. Implant fracture is one possible complication that results in ultimate failure of the dental implant. Such a complication poses a management crisis even for the most experienced clinician. This article reports on a case of implant fracture, its possible causes, and how the case was managed.


Subject(s)
Dental Implants , Dental Prosthesis Design , Dental Restoration Failure , Aged , Dental Abutments , Dental Prosthesis, Implant-Supported , Denture Design , Denture, Partial, Fixed , Denture, Partial, Removable , Female , Follow-Up Studies , Humans , Jaw, Edentulous, Partially/diagnostic imaging , Jaw, Edentulous, Partially/surgery , Maxilla/surgery , Radiography , Stress, Mechanical , Surface Properties
18.
J Contemp Dent Pract ; 7(2): 112-9, 2006 May 01.
Article in English | MEDLINE | ID: mdl-16685302

ABSTRACT

AIM: To determine the prevalence of tori in Jordanian edentulous patients, the sex variation in their distribution, and their clinical characteristics. METHODS: Three hundred and thirty eight patients were examined in the Prosthodontic Clinic in the Department of Restorative Dentistry at Jordan University of Science and Technology. The location, extent, and clinical presentation of tori were recorded related to the age and sex of patients. RESULTS: The overall prevalence of tori was 13.9%. The prevalence of torus palatinus was 29.8% (14/47), while that of torus mandibularis was significantly higher 42.6% (20/47). Both types of tori were associated with each other in 27.7% of cases (13/47). CONCLUSIONS: There was no significant difference in the prevalence of tori between males and females. There seems to be a strong association between mandibular and palatal tori.


Subject(s)
Exostoses/pathology , Jaw, Edentulous/pathology , Mandibular Diseases/pathology , Maxillary Diseases/pathology , Palate, Hard/pathology , Adult , Age Distribution , Aged , Aged, 80 and over , Chi-Square Distribution , Ethnicity , Exostoses/complications , Exostoses/epidemiology , Exostoses/genetics , Female , Genes, Dominant , Humans , Jaw, Edentulous/complications , Jaw, Edentulous/genetics , Jordan/epidemiology , Male , Mandibular Diseases/epidemiology , Mandibular Diseases/genetics , Maxillary Diseases/epidemiology , Maxillary Diseases/genetics , Middle Aged , Prevalence
19.
Eur J Prosthodont Restor Dent ; 14(1): 13-7, 2006 Mar.
Article in English | MEDLINE | ID: mdl-16599092

ABSTRACT

This study aimed to investigate the frequency of different classes of patterns of partial edentulism and the most frequently used design components of conventional cobalt-chromium RPD constructed for patients attending a dental teaching hospital in Jordan. Two- hundred laboratory authorization forms were reviewed. Of the total 200 patients (150 male, 48 females, mean age 44.5 years), 150 patients had both maxillary and mandibular Co-Cr RPDs constructed with a total number of frameworks sums to 350. Kennedy classification was followed to identify the class of partial edentulism. Of the total 350 patterns, Kennedy class III was the most common classification encountered in maxilla (47%) and in the mandible (45%). Among combinations, maxillary Kennedy class III classification opposing mandibular class III was the most common combination (30%). The lingual bar was the most frequently designed major connector (77%), while palatal strap was the most common connector in the maxilla (38%). Significantly (p<0.05), patterns with Kennedy class II and III were more frequent among males than females. The most common type of direct retainer used was the circumferential clasp in both maxillary and mandibular RPD's. On the other hand, ring clasps were used three times more frequently in mandibular RPD frameworks compared to maxillary RPD's. The RPI clasp assembly was used in class I and class II situations in 75% of cases more common in the mandible. It is concluded that the variations in construction of RPD design concepts with international studies reflects the influence of teaching philosophy and diversity of faculty members' backgrounds.


Subject(s)
Denture Design , Denture Retention/instrumentation , Denture, Partial, Removable , Jaw, Edentulous, Partially/rehabilitation , Adult , Age Factors , Chi-Square Distribution , Chromium Alloys , Cobalt , Dental Clasps , Female , Humans , Jaw, Edentulous, Partially/classification , Jordan , Male , Middle Aged , Prosthodontics/education , Sex Factors
20.
J Ir Dent Assoc ; 48(4): 126-31, 2002.
Article in English | MEDLINE | ID: mdl-12622016

ABSTRACT

OBJECTIVES: The purpose of this article is to present an intraoral technique, which allows a wide local excision of pleomorphic adenoma of the palate with adequate mucosal and periosteal margins. STUDY DESIGN: Between September 1992 and May 1994 ten patients with pleomorphic adenoma of the palate were treated by one surgeon at the Oral and Maxillofacial Surgery Unit of the Jordan University of Science and Technology. A surgical technique, which was particularly useful for tumours extending into the soft palate, is described. RESULTS: Nine patients were aged between 15 and 25 years (mean age 20.1 years) and one patient was aged 50 years. Six of the patients were males. The tumour was removed from all ten patients by wide local excision with adequate margins, and after a follow-up period from 5 to 7 years (mean 6.3 years) there were no recurrences. CONCLUSION: This study has shown that wide local excision used for the treatment of pleomorphic adenoma of the palate is to be recommended. A close follow-up is necessary postoperatively.


Subject(s)
Adenoma, Pleomorphic/surgery , Palatal Neoplasms/surgery , Salivary Gland Neoplasms/surgery , Adolescent , Adult , Female , Follow-Up Studies , Hemostasis, Surgical , Humans , Male , Middle Aged , Mouth Mucosa/transplantation , Palate, Hard/surgery , Palate, Soft/surgery , Periosteum/surgery , Surgical Flaps , Uvula/surgery