Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
Add more filters










Publication year range
1.
Jpn J Radiol ; 2024 May 09.
Article in English | MEDLINE | ID: mdl-38720059

ABSTRACT

This study provides a comprehensive evaluation of the occupational radiation exposure faced by healthcare professionals during Endoscopic Retrograde Cholangiopancreatography (ERCP) procedures. Utilizing an anthropomorphic RANDO phantom equipped with Thermoluminescent Dosimeters (TLDs), we replicated ERCP scenarios to measure radiation doses received by medical staff. The study meticulously assessed radiation exposure in various corresponding body regions typically occupied by medical staff during ERCP, with a focus on eyes, thyroid, hands, and reproductive corresponding organ regions. The findings revealed significant variations in radiation doses across different body parts, highlighting areas of higher exposure and underscoring the need for improved protective measures and procedural adjustments. The effective radiation doses were calculated using standard protocols, considering the varying levels of protection offered by lead aprons and thyroid shields. The results demonstrate the substantial radiation exposure experienced by healthcare staff, particularly in regions not adequately shielded. This study emphasizes the necessity for enhanced radiation safety protocols in clinical settings, advocating for advanced protective equipment, training in radiation safety, and the exploration of alternative imaging modalities. The findings have crucial implications for both patient and staff safety, ensuring the continued efficacy and safety of ERCP and similar interventional procedures. This research contributes significantly to the field of occupational health and safety in interventional radiology, providing vital data for the development of safer medical practices.

2.
Heliyon ; 10(4): e25932, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38370260

ABSTRACT

In this study, it was aimed to evaluate the effect of ethanol extract of Annona Muricata (AM) leaves in the prevention of brain damage caused by ionizing radiation (IR). This study was conducted in the Experimental Animal Research Unit of a university with 28 adults female Wistar Albino rats. The experimental groups were as follows: Control group (n = 8), AM group (n = 6), IR group (n = 8), AM + IR group (n = 6). In the IR group, astrocyte hypertrophy, microglial reaction and inflammatory reaction levels were significantly higher than the control and AM groups (P < 0.001). Edema was significantly higher in the IR group compared to the control group (P=0.001). The MDA of the IR group was significantly higher compared to the control group and AM group (P=0.031, P=0.006, respectively). The MDA of the AM + IR group was significantly higher than the AM group (P=0.039). Our findings show that histomorphology and oxidant damage caused by IR can be ameliorated using AM, as demonstrated by the comparison of the controls to AM + IR recipients, which showed similar histomorphology and oxidant damage levels.

3.
Heliyon ; 9(7): e17838, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37456003

ABSTRACT

We report the functional assessment of tungsten (VI) oxide on gamma-ray attenuation properties of 60Sb2O3-(40-x)NaPO3-xWO3 antimony glasses. The elemental mass-fractions and glass-densities of each glass sample are specified separately for the MCNPX Monte Carlo code. In addition to fundamental gamma absorption properties, Transmission Factors throughout a broad radioisotope energy range were measured. According to findings, holmium (Ho) incorporation into the glass structure resulted in a net increase of 0.3406 g/cm3, whereas cerium (Ce) addition resulted in a net increase of 0.2047 g/cm3. The 40% WO3 reinforced S7 sample was found to have the greatest LAC value, even though seven glass samples exhibited identical behavior. The S2 sample had the lowest HVL values among the glass groups evaluated in this work, computed in the energy range of 0.015-15 MeV. The lowest EBF and EABF values were reported for 40% WO3 reinforced S7 sample with the highest LAC and density values. According to the findings of this research, WO3 will likely make a significant contribution to the gamma ray absorption properties of antimony glasses, which are employed for optical and structural modification. Therefore, it can be concluded that WO3 may be treated monotonically and can be employed successfully in circumstances where gamma-ray absorption characteristics, optical properties, and structural qualities need to be enhanced.

4.
Radiat Phys Chem Oxf Engl 1993 ; 211: 111025, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37250685

ABSTRACT

Introduction: CTPA stands for computed tomography pulmonary angiography. CTPA is an X-ray imaging that combines X-rays and computer technology to create detailed images of the pulmonary arteries and veins in the lungs. This test diagnoses and monitors conditions like pulmonary embolism, arterial blockages, and hypertension. Coronavirus (COVID-19) has threatened world health over the last three years. The number of (CT) scans increased and played a vital role in diagnosing COVID-19 patients, including life-threatening pulmonary embolism (PE). This study aimed to assess the radiation dose resulted from CTPA for COVID-19 patients. Methods: Data were collected retrospectively from CTPA examinations on a single scanner in 84 symptomatic patients. The data collected included the dose length product (DLP), volumetric computed tomography dose index (CTDIvol), and size-specific dose estimate (SSDE). The organ dose and effective dose were estimated using VirtualDose software. Results: The study population included 84 patients, 52% male and 48% female, with an average age of 62. The average DLP, CTDIvol, and SSDE were 404.2 mGy cm, 13.5 mGy, and 11.6 mGy\, respectively. The mean effective doses (mSv) for males and females were 3.01 and 3.29, respectively. The maximum to minimum organ doses (mGy) between patients was 0.8 for the male bladder and 7.33 for the female lung. Conclusions: The increase in CT scans during the COVID-19 pandemic required close dose monitoring and optimization. The protocol used during CTPA should guarantee a minimum radiation dose with maximum patient benefits.

5.
Front Public Health ; 11: 1171209, 2023.
Article in English | MEDLINE | ID: mdl-37064659

ABSTRACT

Introduction: A lead-acrylic protective screen is suggested to reduce radiation exposure to the unexposed breast during mammography. The presence of toxic lead in its structure may harm the tissues with which it comes in contact. This study aimed to design a CdO-rich quaternary tellurite glass screen (C40) and evaluate its efficiency compared to the Lead-Acrylic protective screen. Methods: A three-layer advanced heterogeneous breast phantom designed in MCNPX (version 2.7.0) general-purpose Monte Carlo code. Lead acrylic and C40 shielding screens were modeled in the MCNPX and installed between the right and left breast. The reliability of the absorption differences between the lead acrylic and C40 glass were assessed. Results and discussion: The results showed that C40 protective glass screen has much superior protection properties compared to the lead acrylic protective screen. The amount of total dose absorbed in the unexposed breast for C40 was found to be much less than that for lead-based acrylic. The protection provided by the C40 glass screen is 35-38% superior to that of the Lead-Acrylic screen. The C40 offer the opportunity to avoid the toxic Pb in the structure of Lead-Acrylic material and may be utilized for mammography to offer superior radioprotection to Lead-Acrylic and significantly lower the dose amount in the unexposed breast. It can be concluded that transparent glass screens may be utilized for radiation protection purposes in critical diagnostic radiology applications through mammography.


Subject(s)
Radiation Protection , Radiation Protection/methods , Radiation Dosage , Monte Carlo Method , Benchmarking , Reproducibility of Results , Mammography/methods
6.
Heliyon ; 9(4): e14881, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37025762

ABSTRACT

We report the critical optical properties such as Average Visible Transmittance (AVT), colour, Color Rendering Index (CRI), and Correlated Color Temperature (CCT) of a multicomponent glass system with a nominal composition of 50TeO2-30B2O3-(20-x)Li2O-xCeO2 (x = 0,0.5,1,2,3,4,5,10,15,20 mol%). Various advanced theoretical approaches as well as calculations are utilized in terms of determining the optical properties of studied glasses. The maximum transmittance and AVT values of the glass system exceeded 80% and 79.59%, respectively. The colour coordinates are found extremely near to D65 and the achromatic point without CeO2 contribution. According to our results, the current system has a promising ability to be utilized for coloured window applications in terms of both AVT and colour with 2% CeO2 doping. Our results showed that, the CeO2 additive is able to move the glass colour straight into the red spectrum by shifting the transmittance spectrum to the long-wavelength portion of the visible spectrum. With 10% CeO2 doping, opacity in the visible area and permeability in the NIR region are obtained, and the CCT value changes from 5002 K to 2560 K. It can be concluded that a filter system with modifiable NIR or red optical characteristics may be produced through the CeO2 alterations in borotellurite glass systems.

7.
Medicina (Kaunas) ; 59(3)2023 Mar 21.
Article in English | MEDLINE | ID: mdl-36984628

ABSTRACT

Background and Objectives: Quality assurance is an integral part of brachytherapy. Traditionally, radiographic films have been used for source position verification, however, in many clinics, computerized tomography simulators have replaced conventional simulators, and computerized radiography systems have replaced radiographic film processing units. With these advances, the problem of controlling source position verification without traditional radiographic films and conventional simulators has appeared. Materials and Methods: In this study, we investigated an alternative method for source position verification for brachytherapy applications. Source positions were evaluated using Gafchromic™ RTQA2 and EBT3 film and visually compared to exposed RTQA radiochromic film when using a Nucletron Oldelft Simulix HP conventional simulator and a Gammamed 12-i brachytherapy device for performance evaluation. Gafchromic film autoradiography was performed with a linear accelerator (LINAC) on-board imager (OBI). Radiochromic films are very suitable for evaluation by visual inspection with a LINAC OBI. Results: The results showed that this type of low-cost, easy-to-find material can be used for verification purposes under clinical conditions. Conclusions: It can be concluded that source-position quality assurance may be performed through a LINAC OBI device.


Subject(s)
Brachytherapy , Film Dosimetry , Humans , Radiotherapy Dosage , Film Dosimetry/methods , Brachytherapy/methods , Tomography, X-Ray Computed
8.
Heliyon ; 9(3): e14274, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36950638

ABSTRACT

This study's primary objective is to provide the preliminary findings of novel research on the design of Indium (III) oxide-reinforced glass container that were thoroughly developed for the purpose of a nuclear material container for transportation and waste management applications. The shielding characteristics of an Indium (III) oxide-reinforced glass container with a certain elemental composition against the 60Co radioisotope was thoroughly evaluated. The energy deposition in the air surrounding the designed portable glass containers is measured using MCNPX general-purpose Monte Carlo code. Simulation studies were carried out using Lenovo-P620 workstation and the number of tracks was defined as 108 in each simulation phase. According to results, the indium oxide-doped C6 (TZI8) container exhibits superior protective properties compared to other conventional container materials such as 0.5Bitumen-0.5 Cement, Pb Glass composite, Steel-Magnetite concrete. In addition to its superiority in terms of nuclear safety, it is proposed that the source's simultaneous observation and monitoring, as well as the C6 (TZI8) glass structure's transparency, be underlined as significant advantages. High-density glasses, which may replace undesirable materials such as concrete and lead, provide several advantages in terms of production ease, non-toxic properties, and resource monitoring. In conclusion, the use of Indium (III) oxide-reinforced glass with its high transparency and outstanding protection properties may be a substantial choice in places where concrete is required to ensure the safety of nuclear materials.

9.
Front Public Health ; 11: 1136864, 2023.
Article in English | MEDLINE | ID: mdl-36935709

ABSTRACT

Introduction: We report the breast and chest radiation dose assessment for mammographic examinations using a three-layer heterogeneous breast phantom through the MCNPX Monte Carlo code. Methods: A three-layer heterogeneous phantom along with compression plates and X-ray source are modeled. The validation of the simulation code is obtained using the data of AAPM TG-195 report. Deposited energy amount as a function of increasing source energy is calculated over a wide energy range. The behavioral changes in X-ray absorption as well as transmission are examined using the F6 Tally Mesh extension of MCNPX code. Moreover, deposited energy amount is calculated for modeled body phantom in the same energy range. Results and discussions: The diverse distribution of glands has a significant impact on the quantity of energy received by the various breast layers. In layers with a low glandular ratio, low-energy primary X-ray penetrability is highest. In response to an increase in energy, the absorption in layers with a low glandular ratio decreased. This results in the X-rays releasing their energy in the bottom layers. Additionally, the increase in energy increases the quantity of energy absorbed by the tissues around the breast.


Subject(s)
Mammography , Monte Carlo Method , Mammography/methods , Radiation Dosage , Radiography
10.
Medicina (Kaunas) ; 59(2)2023 Feb 09.
Article in English | MEDLINE | ID: mdl-36837529

ABSTRACT

Background: During mammography, a lead-acrylic protective screen is recommended to reduce radiation exposure to the unexposed breast. Objectives: This research study aimed to construct an Indium-(III)-oxide-rich tellurite-glass screen (TZI8) and compare its performance to that of lead acrylic. Materials and Methods: A three-layer heterogeneous-breast phantom was developed, using the MCNPX (version 2.7.0) Monte Carlo code. An MCNPX-simulation geometry was designed and implemented, using the lead-acrylic and TZI8 shielding screens between the right and left breast. Next, the reliability of the phantom and the variations in absorption between the lead-acrylic and TZI8 glass were investigated. Results: The findings show that the TZI8-protective-glass screen offers significantly greater radioprotection than the lead-acrylic material. The quantity of total dose absorbed in the unexposed breast was much lower for TZI8 than for lead-based acrylic. The TZI8-glass screen gives about 60% more radioprotection than the lead-acrylic screen. Conclusion: Considering the toxic lead in the structure that may be hazardous to the human tissues, the TZI8-glass screen may be used in mammography examination to provide greater radioprotection than the lead-acrylic screen, in order to greatly reduce the dose to the unexposed breast.


Subject(s)
Breast , Indium , Humans , Reproducibility of Results , Mammography , Computer Simulation
11.
Heliyon ; 8(10): e10839, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36247126

ABSTRACT

The nuclear spectroscopy method has long been used for advanced studies on nuclear physics. In order to decrease costs and increase the efficiency of nuclear radiation investigations, quick and efficient solutions are required. The purpose of this research was to calculate the whole energy peak efficiency values for a range of gamma-ray energies, from 30.973 keV to 1408 keV, at various source-detector distances using the MCNPX Monte Carlo code, which is extensively used in nuclear medicine, industry, and scientific research. As a result, the modeled detectors' full-energy peak efficiencies were calculated and compared to both experimental data and Monte Carlo simulations. Experiment results and prior studies using Monte Carlo simulations were found to be very consistent with these results. The counting efficiency against source-detector distance is then calculated using the modeled detectors. The data we have show that LaBr3(Ce) has outstanding detection properties. This study's findings might be used to improve the design of detectors for use in wide range of high-tech gamma spectroscopy and nuclear research applications.

12.
Materials (Basel) ; 15(7)2022 Mar 27.
Article in English | MEDLINE | ID: mdl-35407796

ABSTRACT

In this study, three different sliding bearing alloy samples were investigated in terms of their performance on attenuation characteristics and behavioral attitudes under 0.015-15 MeV gamma-ray exposure. Accordingly, different types of advanced calculation methods were utilized to calculate the radiation shielding parameters. Next, several gamma-ray shielding parameters and exposure rates in addition to fast neutron removal cross-section were determined. Furthermore, exposure and energy absorption buildup factors were determined by using G-P fitting method. Mass attenuation coefficients (MAC) values were recorded as 2.5246, 2.5703, and 2.5827 (cm2/g) for Alloy1, Alloy2, and Alloy3 samples at 15 MeV photon energy, respectively. At 40 mfp, the highest EBF values were reported as 1,376,274, 1,003,593, and 969,373 for Alloy1, Alloy2, and Alloy3 samples. The results of this extended investigation showed that the Alloy3 sample with the highest Pb reinforcement amount has superior shielding capability among the investigated samples. It can be concluded from the results that substitution of Pb with Bi in the recent alloy structure has a monotonic effect on different types of shielding parameters. Therefore, it can also be concluded that Pb is a remarkable tool for the improvement of the shielding properties of studied alloy structures.

13.
Materials (Basel) ; 14(24)2021 Dec 13.
Article in English | MEDLINE | ID: mdl-34947296

ABSTRACT

The direct influence of La3+ ions on the gamma-ray shielding properties of cobalt-doped heavy metal borate glasses with the chemical formula 0.3CoO-(80-x)B2O3-19.7PbO-xLa2O3: x = 0, 0.5, 1, 1.5, and 2 mol% was examined herein. Several significant radiation shielding parameters were evaluated. The glass density was increased from 3.11 to 3.36 g/cm3 with increasing La3+ ion content from 0 to 2 mol%. The S5 glass sample, which contained the highest concentration of La3+ ions (2 mol%), had the maximum linear (µ) and mass (µm) attenuation coefficients for all photon energies entering, while the S1 glass sample free of La3+ ions possessed the minimum values of µ and µm. Both the half value layer (T1/2) and tenth value layer (TVL) of all investigated glasses showed a similar trend of (T1/2, TVL)S1 > (T1/2, TVL)S2 > (T1/2, TVL)S3 > (T1/2, TVL)S4 > (T1/2, TVL)S5. Our results revealed that the S5 sample had the highest effective atomic number (Zeff) values over the whole range of gamma-ray energy. S5 had the lowest exposure (EBF) and energy absorption (EABF) build-up factor values across the whole photon energy and penetration depth range. Our findings give a strong indication of the S5 sample's superior gamma-ray shielding characteristics due to the highest contribution of lanthanum oxide.

14.
Materials (Basel) ; 14(21)2021 Nov 05.
Article in English | MEDLINE | ID: mdl-34772194

ABSTRACT

This study aimed to perform an investigation for the potential implementation of bismuth silicate glasses as novel shield equipment instead of ordinary shields in nuclear medicine facilities. Accordingly, a group of Bi2O3 reinforced silicate glass system were investigated and compared with ordinary shields in terms of their gamma-ray attenuation properties in diagnostic nuclear medicine radioisotope energies emitted from 99mTc, 111In, 67Ga, 123I, 131I, 81mKr, 201Tl, 133Xe. Mass attenuation coefficient (µm) results for glass samples were calculated comparatively with the XCOM program and MCNPX code. The gamma-ray attenuation parameters such as half value layer (HVL), tenth value layer (TVL), mean free path (MFP), effective atomic number (Zeff) were obtained in the diagnostic gamma ray energy range from 75 to 336 keV. To confirm the attenuation performance of superior sample, obtained results were extensively compared with ordinary shielding materials. According to the results obtained, BISI6 glass sample with the highest Bi2O3 additive has an excellent gamma-ray protection.

15.
Materials (Basel) ; 14(19)2021 Oct 08.
Article in English | MEDLINE | ID: mdl-34640290

ABSTRACT

We aimed to determine the contribution of various trivalent ions like Al and rare-earths (Y, Nd, Sm, Eu) on resistance behaviors of different types of bismo-borate glasses. Accordingly, eight different bismuth borate glasses from the system: 40Bi2O3-59B2O3-1Tv2O3 (where Tv = Al, Y, Nd, Sm, and Eu) and three glasses of (40Bi2O3-60B2O3; 37.5Bi2O3-62.5B2O3; and 38Bi2O3-60B2O3-2Al2O3) compositions were extensively investigated in terms of their nuclear attenuation shielding properties, along with effective conductivity and buildup factors. The Py-MLBUF online platform was also utilized for determination of some essential parameters. Next, attenuation coefficients, along with half and tenth value layers, have been determined in the 0.015 MeV-15 MeV photon energy range. Moreover, effective atomic numbers and effective atomic weight, along with exposure and energy absorption buildup factors, were determined in the same energy range. The result showed that the type of trivalent ion has a direct effect on behaviors of bismo-borate glasses against ionizing gamma-rays. As incident photon energy increases, the effective thermal conductivity decreases rapidly, especially in the low energy range, where photoelectric effects dominate the photon-matter interaction. Sample 8 had the minimum heat conductivity at low photon energies; our findings showed that Eu-reinforced bismo-borate glass composition, namely 40Bi2O3-59B2O3-1Eu2O3, with a glass density of 6.328 g/cm3 had superior gamma-ray attenuation properties. These outcomes would be useful for the scientific community to observe the most suitable additive rareearth type and related glass composition for providing the aforementioned shielding properties, in terms of needs and utilization requirements.

16.
Materials (Basel) ; 14(18)2021 Sep 16.
Article in English | MEDLINE | ID: mdl-34576558

ABSTRACT

In this study, a group of heavy metal oxide glasses with a nominal composition of 55B2O3 + 19.5TeO2 + 10K2O + (15-x) PbO + xAl2O3 + 0.5Eu2O3 (where x = 0, 2.5, 5, 7.5, 10, 12.5, and 15 in wt.%) were investigated in terms of their nuclear radiation shielding properties. These glasses containing lanthanide-doped heavy metal oxide were envisioned to yield valuable results in respect to radiation shielding, and thus a detailed investigation was carried out; the obtained results were compared with traditional and new generation shields. Advanced simulation and theoretical methods have been utilized in a wide range of energy regions. Our results showed that the AL0.0 sample with the highest PbO contribution had superior shielding properties in the entire energy range. The effective removal of cross-sections for fast neutrons (ΣR) was also examined. The results indicated that AL5.0 had the greatest value. While increasing the concentration of Al2O3 in samples had a negative effect on the radiation shielding characteristics, it can be concluded that using PbO in the Eu3+ doped heavy metal oxide glasses could be a useful tool to keep gamma-ray shielding properties at a maximum level.

17.
Polymers (Basel) ; 13(18)2021 Sep 17.
Article in English | MEDLINE | ID: mdl-34578058

ABSTRACT

In this study, brass (Cu/Zn) reinforced polymer composites with different proportions of brass powders were fabricated. Different types of nuclear shielding parameters such as mass and linear attenuation coefficients, radiation protection efficiency, half and tenth value layers, and effective atomic number values were determined experimentally and theoretically in the energy range of 0.060-1.408 MeV in terms of gamma-ray shielding capabilities of fabricated polymer composites. A high Purity Germanium detector (HPGe) in conjunction with a Multi-Channel Analyzer (MCA) and twenty-two characteristic gamma-ray energies have been used in the experimental phase. In addition, the exposure and energy absorption buildup factors of reinforced Cu/Zn composites were calculated, and relative dose distribution values were computed to verify them. Proton mass stopping power (ΨP), proton projected range (ΦP), alpha mass stopping power (ΨA), and alpha projected range (ΦA) parameters, which indicate the interactions of the produced composites with charged particle radiation, were investigated. Fast neutron removal cross-section (ΣR) results were determined to give an idea in terms of neutron shielding. According to the obtained results, it is reported that the CuZn20 coded sample's ability to attenuate gamma-ray and charged particle radiation is more efficient than that of other prepared composites. A CuZn05 coded sample was found to be more suitable for neutron shielding capability.

18.
Materials (Basel) ; 14(15)2021 Aug 03.
Article in English | MEDLINE | ID: mdl-34361524

ABSTRACT

The radiation shielding characteristics of samples from two TeO2 and Sb2O3-based basic glass groups were investigated in this research. TeO2 and Sb2O3-based glasses were determined in the research as six samples with a composition of 10WO3-(x)MoO3-(90 - x)(TeO2/Sb2O3) (x = 10, 20, 30). A general purpose MCNPX Monte Carlo code and Phy-X/PSD platform were used to estimate the radiation shielding characteristics. Accordingly, the linear and mass attenuation coefficients, half value layer, mean free path, variation of the effective atomic number with photon energy, exposure and built-up energy factors, and effective removal cross-section values were determined. It was determined that the results that were produced using the two different techniques were consistent. Based on the collected data, the most remarkable findings were found to be associated with the sample classified as T80 (10WO3 + 10MoO3 + 80TeO2). The current study showed that material density was as equally important as composition in modifying radiation shielding characteristics. With the T80 sample with the greatest density (5.61 g/cm3) achieving the best results. Additionally, the acquired findings were compared to the radiation shielding characteristics of various glass and concrete materials. Increasing the quantity of MoO3 additive, a known heavy metal oxide, in these TeO2 and Sb2O3-based glasses may have a detrimental impact on the change in radiation shielding characteristics.

SELECTION OF CITATIONS
SEARCH DETAIL
...