Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Card Surg ; 36(11): 4024-4029, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34365660

ABSTRACT

INTRODUCTION: Limited data are available about the outcomes of transcatheter mitral valve replacement (TMVR) using transseptal approach in patients with prior mitral valve repair (valve-in-ring) or replacement (valve-in-valve) (TMViVR) and on modes of the prior surgical valve failures. We report our tertiary center TMVR experience in high surgical risk patients with prior mitral valve repair or replacement. METHODS: From December 2016 to January 2020, patients with symptomatic severe mitral valve stenosis and/or insufficiency at increased redo surgical risk were included. TMViVR was performed off-label with Sapien S3 valve (Edwards Lifesciences). Patients were followed within 30-days and 1-year from the procedure. RESULTS: Twenty-seven patients underwent transcatheter mitral valve-in-valve (n = 21) or valve-in-ring (n = 6) replacement. Mean ± SD age was 71.8 ± 11 years with Society of Thoracic Surgeons' calculated mortality 7.1 ± 4.6%. The etiology of valve failure was stenosis in 17 (63%) patients, insufficiency in 4 (14.8%) patients, and both in 6 (22.2%) patients. TMViVR technical success was 100% in all patients. Left ventricular outflow track (LVOT) obstruction was observed in only one (3.7%) patient. Zero patients had moderate or severe central mitral valve regurgitation or paravalvular leak. All patients had symptomatic improvement at 30 days. The mean transmitral diastolic pressure gradient decreased from 14.1 ± 4.6 to 6.9 ± 4.6 mm Hg (p < .001) at 30 days. The one patient with LOVT obstruction required readmission at 5-months. One-year survival was 95%. At 1-year mean gradients remained lower than the baseline (7.0 ± 3.0 vs. 12.4 ± 4.0, p = .002). CONCLUSIONS: Transcatheter mitral valve-in-valve and valve-in-ring replacement is feasible and safe. The improvement in mitral valve hemodynamics appears to be durable.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Aged , Aged, 80 and over , Cardiac Catheterization , Humans , Middle Aged , Mitral Valve/surgery , Mitral Valve Insufficiency/surgery , Risk Factors , Surgical Instruments , Treatment Outcome
3.
Cardiol Ther ; 6(2): 251-259, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28667514

ABSTRACT

INTRODUCTION: Hemodynamic measurements can assess for paravalvular aortic regurgitation after transcatheter aortic valve replacement (TAVR). This study compared the utility of different invasive hemodynamic measures in providing prognostic information. METHODS: This retrospective observational study of TAVR patients at a Veterans Hospital assessed aortic regurgitation index, diastolic delta, pulse pressure, and heart rate adjusted diastolic delta obtained at valve implantation. The primary outcome was total mortality. RESULTS: Overall, 151 patients underwent TAVR. Immediately after implantation, mean aortic regurgitation index was 31 ± 8.6, mean diastolic delta was 38 ± 9.8 mmHg, mean pulse pressure was 67 ± 18 mmHg, and mean heart rate adjusted diastolic delta was 47 ± 14.3 mmHg/beats per minute. Two percent of patients had ≥ moderate paravalvular aortic regurgitation by postoperative transthoracic echocardiography. Total mortality was 15.2% at a mean follow-up of 12.7 ± 9.2 months. Aortic regurgitation index <25 vs. ≥25, diastolic delta <19 vs. ≥19 mmHg, and pulse pressure >60 vs. ≤60 mmHg were not associated with total mortality. However, total mortality was 50% for heart rate adjusted diastolic delta <25 mmHg/beats per minute vs. 12.6% for heart rate adjusted diastolic delta ≥25 mmHg/beats per minute (p = 0.017). In a multivariate Cox regression analysis, heart rate adjusted diastolic delta <25 mmHg/beats per minute vs. heart rate adjusted diastolic delta ≥25 mmHg/beats per minute was associated with total mortality (hazard ratio 9.4, 95% confidence interval 2.0-44, p = 0.004). CONCLUSIONS: Among a cohort of TAVR patients, the only invasive hemodynamic test independently associated with total mortality was heart rate adjusted diastolic delta.

SELECTION OF CITATIONS
SEARCH DETAIL
...