Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
Eur Radiol ; 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38528136

ABSTRACT

OBJECTIVE: To explore the ability of artificial intelligence (AI) to classify breast cancer by mammographic density in an organized screening program. MATERIALS AND METHOD: We included information about 99,489 examinations from 74,941 women who participated in BreastScreen Norway, 2013-2019. All examinations were analyzed with an AI system that assigned a malignancy risk score (AI score) from 1 (lowest) to 10 (highest) for each examination. Mammographic density was classified into Volpara density grade (VDG), VDG1-4; VDG1 indicated fatty and VDG4 extremely dense breasts. Screen-detected and interval cancers with an AI score of 1-10 were stratified by VDG. RESULTS: We found 10,406 (10.5% of the total) examinations to have an AI risk score of 10, of which 6.7% (704/10,406) was breast cancer. The cancers represented 89.7% (617/688) of the screen-detected and 44.6% (87/195) of the interval cancers. 20.3% (20,178/99,489) of the examinations were classified as VDG1 and 6.1% (6047/99,489) as VDG4. For screen-detected cancers, 84.0% (68/81, 95% CI, 74.1-91.2) had an AI score of 10 for VDG1, 88.9% (328/369, 95% CI, 85.2-91.9) for VDG2, 92.5% (185/200, 95% CI, 87.9-95.7) for VDG3, and 94.7% (36/38, 95% CI, 82.3-99.4) for VDG4. For interval cancers, the percentages with an AI score of 10 were 33.3% (3/9, 95% CI, 7.5-70.1) for VDG1 and 48.0% (12/25, 95% CI, 27.8-68.7) for VDG4. CONCLUSION: The tested AI system performed well according to cancer detection across all density categories, especially for extremely dense breasts. The highest proportion of screen-detected cancers with an AI score of 10 was observed for women classified as VDG4. CLINICAL RELEVANCE STATEMENT: Our study demonstrates that AI can correctly classify the majority of screen-detected and about half of the interval breast cancers, regardless of breast density. KEY POINTS: • Mammographic density is important to consider in the evaluation of artificial intelligence in mammographic screening. • Given a threshold representing about 10% of those with the highest malignancy risk score by an AI system, we found an increasing percentage of cancers with increasing mammographic density. • Artificial intelligence risk score and mammographic density combined may help triage examinations to reduce workload for radiologists.

2.
Insights Imaging ; 15(1): 38, 2024 Feb 08.
Article in English | MEDLINE | ID: mdl-38332187

ABSTRACT

OBJECTIVES: The randomized controlled trial comparing digital breast tomosynthesis and synthetic 2D mammograms (DBT + SM) versus digital mammography (DM) (the To-Be 1 trial), 2016-2017, did not result in higher cancer detection for DBT + SM. We aimed to determine if negative cases prior to interval and consecutive screen-detected cancers from DBT + SM were due to interpretive error. METHODS: Five external breast radiologists performed the individual blinded review of 239 screening examinations (90 true negative, 39 false positive, 19 prior to interval cancer, and 91 prior to consecutive screen-detected cancer) and the informed consensus review of examinations prior to interval and screen-detected cancers (n = 110). The reviewers marked suspicious findings with a score of 1-5 (probability of malignancy). A case was false negative if ≥ 2 radiologists assigned the cancer site with a score of ≥ 2 in the blinded review and if the case was assigned as false negative by a consensus in the informed review. RESULTS: In the informed review, 5.3% of examinations prior to interval cancer and 18.7% prior to consecutive round screen-detected cancer were considered false negative. In the blinded review, 10.6% of examinations prior to interval cancer and 42.9% prior to consecutive round screen-detected cancer were scored ≥ 2. A score of ≥ 2 was assigned to 47.8% of negative and 89.7% of false positive examinations. CONCLUSIONS: The false negative rates were consistent with those of prior DM reviews, indicating that the lack of higher cancer detection for DBT + SM versus DM in the To-Be 1 trial is complex and not due to interpretive error alone. CRITICAL RELEVANCE STATEMENT: The randomized controlled trial on digital breast tomosynthesis and synthetic 2D mammograms (DBT) and digital mammography (DM), 2016-2017, showed no difference in cancer detection for the two techniques. The rates of false negative screening examinations prior to interval and consecutive screen-detected cancer for DBT were consistent with the rates in prior DM reviews, indicating that the non-superior DBT performance in the trial might not be due to interpretive error alone. KEY POINTS: • Screening with digital breast tomosynthesis (DBT) did not result in a higher breast cancer detection rate compared to screening with digital mammography (DM) in the To-Be 1 trial. • The false negative rates for examinations prior to interval and consecutive screen-detected cancer for DBT were determined in the trial to test if the lack of differences was due to interpretive error. • The false negative rates were consistent with those of prior DM reviews, indicating that the lack of higher cancer detection for DBT versus DM was complex and not due to interpretive error alone.

3.
JCO Precis Oncol ; 7: e2300338, 2023 Sep.
Article in English | MEDLINE | ID: mdl-38039432

ABSTRACT

PURPOSE: Homologous recombination deficiency (HRD) is highly prevalent in triple-negative breast cancer (TNBC) and associated with response to PARP inhibition (PARPi). Here, we studied the prevalence of HRD in non-TNBC to assess the potential for PARPi in a wider group of patients with breast cancer. METHODS: HRD status was established using targeted gene panel sequencing (360 genes) and BRCA1 methylation analysis of pretreatment biopsies from 201 patients with primary breast cancer in the phase II PETREMAC trial (ClinicalTrials.gov identifier: NCT02624973). HRD was defined as mutations in BRCA1, BRCA2, BRIP1, BARD1, or PALB2 and/or promoter methylation of BRCA1 (strict definition; HRD-S). In secondary analyses, a wider definition (HRD-W) was used, examining mutations in 20 additional genes. Furthermore, tumor BRCAness (multiplex ligation-dependent probe amplification), PAM50 subtyping, RAD51 nuclear foci to test functional HRD, tumor-infiltrating lymphocyte (TIL), and PD-L1 analyses were performed. RESULTS: HRD-S was present in 5% of non-TNBC cases (n = 9 of 169), contrasting 47% of the TNBC tumors (n = 15 of 32). HRD-W was observed in 23% of non-TNBC (n = 39 of 169) and 59% of TNBC cases (n = 19 of 32). Of 58 non-TNBC and 30 TNBC biopsies examined for RAD51 foci, 4 of 4 (100%) non-TNBC and 13 of 14 (93%) TNBC cases classified as HRD-S had RAD51 low scores. In contrast, 4 of 17 (24%) non-TNBC and 15 of 19 (79%) TNBC biopsies classified as HRD-W exhibited RAD51 low scores. Of nine non-TNBC tumors with HRD-S status, only one had a basal-like PAM50 signature. There was a high concordance between HRD-S and either BRCAness, high TIL density, or high PD-L1 expression (each P < .001). CONCLUSION: The prevalence of HRD in non-TNBC suggests that therapy targeting HRD should be evaluated in a wider breast cancer patient population. Strict HRD criteria should be implemented to increase diagnostic precision with respect to functional HRD.


Subject(s)
Triple Negative Breast Neoplasms , Humans , Triple Negative Breast Neoplasms/genetics , B7-H1 Antigen/genetics , Genes, BRCA2 , Mutation , Homologous Recombination/genetics
4.
Eur J Radiol ; 167: 111069, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37708674

ABSTRACT

PURPOSE: To describe and compare early screening outcomes before, during and after a randomized controlled trial with digital breast tomosynthesis (DBT) including synthetic 2D mammography versus standard digital mammography (DM) (To-Be 1) and a follow-up cohort study using DBT (To-Be 2). METHODS: Retrospective results of 125,020 screening examinations from four consecutive screening rounds performed in 2014-2021 were described and compared for pre-To-Be 1 (DM), To-Be 1 (DM or DBT), To-Be 2 (DBT), and post-To-Be 2 (DM) cohorts. Descriptive analyses of rates of recall, biopsy, screen-detected and interval cancer, distribution of histopathologic tumor characteristics and time spent on image interpretation and consensus were presented for the four rounds including five cohorts, one cohort in each screening round except for the To-Be 1 trail, which included a DBT and a DM cohort. Odds ratios (OR) with 95% CIs was calculated for recall and cancer detection rates. RESULTS: Rate of screen-detected cancer was 0.90% for women screened with DBT in To-Be 2 and 0.64% for DM in pre-To-Be 1. The rates did not differ for the To-Be 1 DM (0.61%), To-Be 1 DBT (0.66%) and post-To-Be 2 DM (0.67%) cohorts. The interval cancer rates ranged between 0.13% and 0.20%. The distribution of histopathologic tumor characteristics did not differ between the cohorts. CONCLUSIONS: Screening all women with DBT following a randomized controlled trial in an organized, population-based screening program showed a temporary increase in the rate of screen-detected cancer.


Subject(s)
Mammography , Humans , Female , Follow-Up Studies , Retrospective Studies , Biopsy , Consensus
5.
Genome Med ; 14(1): 86, 2022 08 11.
Article in English | MEDLINE | ID: mdl-35948919

ABSTRACT

BACKGROUND: Subclonal evolution during primary breast cancer treatment is largely unexplored. We aimed to assess the dynamic changes in subclonal composition of treatment-naïve breast cancers during neoadjuvant chemotherapy. METHODS: We performed whole exome sequencing of tumor biopsies collected before, at therapy switch, and after treatment with sequential epirubicin and docetaxel monotherapy in 51 out of 109 patients with primary breast cancer, who were included in a prospectively registered, neoadjuvant single-arm phase II trial. RESULTS: There was a profound and differential redistribution of subclones during epirubicin and docetaxel treatment, regardless of therapy response. While truncal mutations and main subclones persisted, smaller subclones frequently appeared or disappeared. Reassessment of raw data, beyond formal mutation calling, indicated that the majority of subclones seemingly appearing during treatment were in fact present in pretreatment breast cancers, below conventional detection limits. Likewise, subclones which seemingly disappeared were still present, below detection limits, in most cases where tumor tissue remained. Tumor mutational burden (TMB) dropped during neoadjuvant therapy, and copy number analysis demonstrated specific genomic regions to be systematically lost or gained for each of the two chemotherapeutics. CONCLUSIONS: Sequential epirubicin and docetaxel monotherapy caused profound redistribution of smaller subclones in primary breast cancer, while early truncal mutations and major subclones generally persisted through treatment. TRIAL REGISTRATION: ClinicalTrials.gov, NCT00496795 , registered on July 4, 2007.


Subject(s)
Breast Neoplasms , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Breast Neoplasms/drug therapy , Breast Neoplasms/genetics , Breast Neoplasms/pathology , Clonal Evolution , Cyclophosphamide , Docetaxel/therapeutic use , Epirubicin , Female , Humans , Neoadjuvant Therapy , Taxoids/adverse effects , Taxoids/therapeutic use
7.
Radiology ; 300(1): 66-76, 2021 07.
Article in English | MEDLINE | ID: mdl-33973840

ABSTRACT

Background Prevalent digital breast tomosynthesis (DBT) has shown higher cancer detection rates and lower recall rates compared with those of digital mammography (DM). However, data are limited on rates and histopathologic tumor characteristics of interval and subsequent round screen-detected cancers for DBT. Purpose To follow women randomized to screening with DBT or DM and to investigate rates and tumor characteristics of interval and subsequent round screen-detected cancers. Materials and Methods To-Be is a randomized controlled trial comparing the outcome of DBT and DM in organized breast cancer screening. The trial included 28 749 women, with 22 306 women returning for subsequent DBT screening 2 years later (11 201 and 11 105 originally screened with DBT and DM, respectively). Differences in rates, means, and distribution of histopathologic tumor characteristics between women prevalently screened with DBT versus DM were evaluated with Z tests, t tests, and χ2 tests. Relative risk (RR) with 95% CIs was calculated for the cancer rates. Results Interval cancer rates were 1.4 per 1000 screens (20 of 14 380; 95% CI: 0.9, 2.1) for DBT versus 2.0 per 1000 screens (29 of 14 369; 95% CI: 1.4, 2.9; P = .20) for DM. The rates of subsequent round screen-detected cancer were 8.1 per 1000 (95% CI: 6.6, 10.0) for women originally screened with DBT and 9.1 per 1000 (95% CI: 7.4, 11.0; P = .43) for women screened with DM. The distribution of tumor characteristics did not differ between groups for either interval or subsequent screen-detected cancer. The RR of interval cancer was 0.69 (95% CI: 0.39, 1.22; P = .20) for DBT versus DM, whereas RR of subsequent screen-detected cancer for women prevalently screened with DBT versus DM was 0.89 (95% CI: 0.67, 1.19; P = .43). Conclusion Rates of interval or subsequent round screen-detected cancers and their tumor characteristics did not differ between women originally screened with digital breast tomosynthesis (DBT) versus digital mammography. The analysis suggests that the benefits of prevalent DBT screening did not come at the expense of worse downstream screening performance measures in a population-based screening program. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Taourel in this issue.


Subject(s)
Breast Neoplasms/diagnostic imaging , Mammography/methods , Aged , Breast/diagnostic imaging , Female , Humans , Middle Aged , Norway , Reproducibility of Results , Sensitivity and Specificity
8.
Eur J Radiol ; 139: 109665, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33823373

ABSTRACT

PURPOSE: We aimed to determine if compression force or pressure could be associated with early performance measures for women screened with digital breast tomosynthesis (DBT) in BreastScreen Norway. Early performance measures included rates of consensus, recall, and screen-detected breast cancer. METHOD: Data on compression force and pressure, compressed breast thickness and breast characteristics were extracted from an automated software for density assessment of DBT screening examinations for 25,286 women. For descriptive analyses, force (Newton, N) and pressure (kilopascal, kPa) were categorized into quartiles. Analyses were stratified by mammographic view, craniocaudal (CC) and mediolateral oblique (MLO). Logistic regression with restricted cubic splines was used to investigate the association between force and pressure as continuous exposures and early performance measures adjusted for age, compressed breast thickness and fibroglandular volume. RESULTS: Mean age of the screened women was 60.7 (SD = 5.2) years. Mean compression force was 90.8 (SD = 14.2) N for CC and 106.3 (SD = 20.6) N for MLO, and pressure was 11.3 (SD = 3.6) kPa for CC and 8.7 (SD = 2.0) kPa for MLO. The highest rates of screen-detected cancer were observed for low force (1.04 % for <82.5 N for CC and 1.07 % for <92.0 N for MLO) and low pressure (1.07 % for <7.2 kPa for MLO). No association was found between force or pressure as continuous exposures and early performance measures in adjusted regression analyses. CONCLUSIONS: We found the highest rates of screen-detected cancer for low force and pressure, but no significant association between continuous values of force or pressure and early performance measures in DBT. The findings might indicate that the levels of force and pressure in DBT are of lower significance for screening performance than reported in standard digital mammography.


Subject(s)
Breast Neoplasms , Mammography , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Early Detection of Cancer , Female , Humans , Middle Aged , Norway/epidemiology
9.
Radiology ; 297(3): 522-531, 2020 12.
Article in English | MEDLINE | ID: mdl-32930649

ABSTRACT

Background Digital breast tomosynthesis (DBT) is considered superior to digital mammography (DM) for women with dense breasts. Purpose To identify differences in screening outcomes, including rates of recall, false-positive (FP) findings, biopsy, cancer detection rate, positive predictive value of recalls and biopsies, and histopathologic tumor characteristics by density using DBT combined with two-dimensional synthetic mammography (SM) (hereafter, DBT+SM) versus DM. Materials and Methods This randomized controlled trial comparing DBT+SM and DM was performed in Bergen as part of BreastScreen Norway, 2016-2017. Automated software measured density (Volpara Density Grade [VDG], 1-4). The outcomes were compared for DBT+SM versus DM by VDG in descriptive analyses. A stratified log-binomial regression model was used to estimate relative risk of outcomes in subgroups by screening technique. Results Data included 28 749 women, 14 380 of whom were screened with DBT+SM and 14 369 of whom were screened with DM (both groups: median age, 59 years; interquartile range [IQR], 54-64 years). The recall rate was lower for women screened with DBT+SM versus those screened with DM for VDG 1 (2.1% [81 of 3929] vs 3.3% [106 of 3212]; P = .001) and VDG 2 (3.2% [200 of 6216] vs 4.3% [267 of 6280]; P = .002). For DBT+SM, adjusted relative risk of recall (VDG 2: 1.8; P < .001; VDG 3: 2.4; P < .001; VDG 4: 1.8; P = .02) and screen-detected breast cancer (VDG 2: 2.4; P = .004; VDG 3: 2.8; P = .01; VDG 4: 2.8; P = .05) increased with VDG, whereas no differences were observed for DM (relative risk of recall for VDG 2: 1.3; P = .06; VDG 3: 1.1; P = .41; VDG 4: 1.1; P = .71; and relative risk of screen-detected breast cancer for VDG 2: 1.7; P = .13; VDG 3: 2.1; P = .06; VDG 4: 2.2; P = .15). Conclusion Screening with digital breast tomosynthesis combined with synthetic two-dimensional mammograms (DBT+SM) versus digital mammography (DM) yielded lower recall rates for women with Volpara Density Grade (VDG) 1 and VDG 2. Adjusted relative risk of recall and screen-detected breast cancer increased with denser breasts for DBT+SM but not for DM. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Sechopoulos and Athanasiou in this issue.


Subject(s)
Breast Density , Breast Neoplasms/diagnostic imaging , Mammography/methods , Early Detection of Cancer , Female , Humans , Middle Aged , Norway
10.
J Med Screen ; 27(1): 31-39, 2020 03.
Article in English | MEDLINE | ID: mdl-31554445

ABSTRACT

Objective: To compare breast characteristics, compression parameters, and early performance measures (rates of recall, screen-detected and interval breast cancer, and histopathologic tumour characteristics) for mammographic screening at a stationary versus mobile screening unit. Methods: Results from 92,408 mammographic screening examinations performed as part of BreastScreen Norway during 2008­2017 at either a stationary (n = 52,620) or mobile (n = 39,788) unit in Hordaland county were compared using descriptive statistics and generalized estimating equations. A generalized estimating equation for a binary outcome was used to estimate crude and adjusted odds ratios with 95% confidence intervals for the outcomes of interest. Adjusted generalized estimating equation models included age, breast volume, and density grade as covariates. Results: Screening at the stationary unit was performed on smaller breasts with higher mammographic density, using lower compression force but higher pressure than at the mobile unit. Using the stationary screening unit as reference, for women screened at the mobile unit, the adjusted odds ratio was: for recall 0.94 (95% CI: 0.87--1.01), screen-detected breast cancer 0.92 (95% CI: 0.78--1.10), and interval breast cancer 1.17 (95% CI: 0.83­1.64). Conclusions: The quality of care did not differ for women screened at the stationary versus the mobile unit, but there were differences between the women who attended the two units. Sociodemographic factors should be included in future analyses to fully understand the risk of breast cancer among women residing in urban versus rural areas.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast/diagnostic imaging , Mammography , Mobile Health Units , Adult , Aged , Ambulatory Care Facilities , Breast/anatomy & histology , Breast Density , Early Detection of Cancer , Female , Humans , Mammography/methods , Middle Aged , Norway
12.
Lancet Oncol ; 20(6): 795-805, 2019 06.
Article in English | MEDLINE | ID: mdl-31078459

ABSTRACT

BACKGROUND: Digital breast tomosynthesis is an advancement of mammography, and has the potential to overcome limitations of standard digital mammography. This study aimed to compare first-generation digital breast tomo-synthesis including two-dimensional (2D) synthetic mammograms versus digital mammography in a population-based screening programme. METHODS: BreastScreen Norway offers all women aged 50-69 years two-view (craniocaudal and mediolateral oblique) mammographic screening every 2 years and does independent double reading with consensus. We asked all 32 976 women who attended the programme in Bergen in 2016-17, to participate in this randomised, controlled trial with a parallel group design. A study-specific software was developed to allocate women to either digital breast tomosynthesis or digital mammography using a 1:1 simple randomisation method based on participants' unique national identity numbers. The interviewing radiographer did the randomisation by entering the number into the software. Randomisation was done after consent and was therefore concealed from both the women and the radiographer at the time of consent; the algorithm was not disclosed to radiographers during the recruitment period. All data needed for analyses were complete 12 months after the recruitment period ended. The primary outcome measure was screen-detected breast cancer, stratified by screening technique (ie, digital breast tomosynthesis and digital mammography). A log-binomial regression model was used to estimate the efficacy of digital breast tomosynthesis versus digital mammography, defined as the crude risk ratios (RRs) with 95% CIs for screen-detected breast cancer for women screened during the recruitment period. A per-protocol approach was used in the analyses. This trial is registered at ClinicalTrials.gov, number NCT02835625, and is closed to accrual. FINDINGS: Between, Jan 14, 2016, and Dec 31, 2017, 44 266 women were invited to the screening programme in Bergen, and 32 976 (74·5%) attended. After excluding women with breast implants and women who did not consent to participate, 29 453 (89·3%) were eligible for electronic randomisation. 14 734 women were allocated to digital breast tomosynthesis and 14 719 to digital mammography. After randomisation, women with a previous breast cancer were excluded (digital breast tomosynthesis group n=314, digital mammography group n=316), women with metastases from melanoma (digital breast tomosynthesis group n=1), and women who informed the radiographer about breast symptoms after providing consent (digital breast tomosynthesis group n=39, digital mammography group n=34). After exclusions, information from 28 749 women were included in the analyses (digital breast tomosynthesis group n=14 380, digital mammography group n=14 369). The proportion of screen-detected breast cancer among the screened women did not differ between the two groups (95 [0·66%, 0·53-0·79] of 14 380 vs 87 [0·61%, 0·48-0·73] of 14 369; RR 1·09, 95% CI 0·82-1·46; p=0·56). INTERPRETATION: This study indicated that digital breast tomosynthesis including synthetic 2D mammograms was not significantly different from standard digital mammography as a screening tool for the detection of breast cancer in a population-based screening programme. Economic analyses and follow-up studies on interval and consecutive round screen-detected breast cancers are needed to better understand the effect of digital breast tomosynthesis in population-based breast cancer screening. FUNDING: Cancer Registry of Norway, Department of Radiology at Haukeland University Hospital, University of Oslo, and Research Council of Norway.


Subject(s)
Adenocarcinoma/diagnosis , Breast Neoplasms/diagnosis , Carcinoma, Ductal, Breast/diagnosis , Carcinoma, Intraductal, Noninfiltrating/diagnosis , Carcinoma, Lobular/diagnosis , Early Detection of Cancer/methods , Mammography/methods , Adenocarcinoma/diagnostic imaging , Aged , Algorithms , Breast Neoplasms/diagnostic imaging , Carcinoma, Ductal, Breast/diagnostic imaging , Carcinoma, Intraductal, Noninfiltrating/diagnostic imaging , Carcinoma, Lobular/diagnostic imaging , Female , Follow-Up Studies , Humans , Mammography/classification , Middle Aged , Prognosis , Radiographic Image Interpretation, Computer-Assisted/methods
13.
Eur Radiol ; 29(3): 1175-1186, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30159620

ABSTRACT

OBJECTIVES: To describe a randomized controlled trial (RCT) of digital breast tomosynthesis including synthesized two-dimensional mammograms (DBT) versus digital mammography (DM) in a population-based screening program for breast cancer and to compare selected secondary screening outcomes for the two techniques. METHODS: This RCT, performed in Bergen as part of BreastScreen Norway, was approved by the Regional Committees for Medical Health Research Ethics. All screening attendees in Bergen were invited to participate, of which 89% (14,274/15,976) concented during the first year, and were randomized to DBT (n = 7155) or DM (n = 7119). Secondary screening outcomes were stratified by mammographic density and compared using two-sample t-tests, chi-square tests, ANOVA, negative binomial regression and tests of proportions (z tests). RESULTS: Mean reading time was 1 min 11 s for DBT and 41 s for DM (p < 0.01). Mean time spent at consensus was 3 min 12 s for DBT and 2 min 12 s for DM (p < 0.01), while the rate of cases discussed at consensus was 6.4% and 7.4%, respectively for DBT and DM (p = 0.03). The recall rate was 3.0% for DBT and 3.6% for DM (p = 0.03). For women with non-dense breasts, recall rate was 2.2% for DBT versus 3.4% for DM (p = 0.04). The rate did not differ for women with dense breasts (3.6% for both). Mean glandular dose per examination was 2.96 mGy for DBT and 2.95 mGy for DM (p = 0.433). CONCLUSIONS: Interim analysis of a screening RCT showed that DBT took longer to read than DM, but had significantly lower recall rate than DM. We found no differences in radiation dose between the two techniques. KEY POINTS: • In this RCT, DBT was associated with longer interpretation time than DM • Recall rates were lower for DBT than for DM • Mean glandular radiation dose did not differ between DBT and DM.


Subject(s)
Breast Density , Breast Neoplasms/diagnosis , Mammography/methods , Mass Screening/methods , Population Surveillance/methods , Aged , Breast Neoplasms/epidemiology , Female , Humans , Incidence , Middle Aged , Norway/epidemiology
14.
Cancer Epidemiol Biomarkers Prev ; 27(9): 1065-1074, 2018 09.
Article in English | MEDLINE | ID: mdl-29925631

ABSTRACT

Background: Volumetric mammographic density (VMD) measures can be obtained automatically, but it is not clear how these relate to breast cancer risk factors.Methods: The cohort consisted of 46,428 women (ages 49-71 years) who participated in BreastScreen Norway between 2007 and 2014 and had information on VMD and breast cancer risk factors. We estimated means of percent and absolute VMD associated with age, menopausal status, body mass index (BMI), and other factors.Results: The associations between VMD and most breast cancer risk factors were modest, although highly significant. BMI was positively associated with absolute VMD, whereas inversely associated with percent VMD. Percent VMD was inversely associated with a 5-year older age at screening in premenopausal and postmenopausal women (-0.18% vs. -0.08% for percent VMD and -0.11 cm3 vs. -0.03 cm3 for absolute VMD). This difference was largest among postmenopausal women with BMI < 25 kg/m2 (P for interaction with percent VMD < 0.0001), never users of postmenopausal hormone therapy (P for interaction < 0.0001), and premenopausal women with a family history of breast cancer (P for interaction with absolute VMD = 0.054).Conclusions: VMD is associated with several breast cancer risk factors, the strongest being BMI, where the direction of the association differs for percent and absolute VMD. The inverse association with age appears modified by menopausal status and other breast cancer risk factors.Impact: Because VMD methods are becoming widely available in screening and clinical settings, the association between VMD measures and breast cancer risk factors should be investigated further in longitudinal studies. Cancer Epidemiol Biomarkers Prev; 27(9); 1065-74. ©2018 AACR.


Subject(s)
Breast Density , Breast Neoplasms/pathology , Early Detection of Cancer , Mammography/methods , Risk Assessment/methods , Age Factors , Aged , Breast Neoplasms/epidemiology , Cohort Studies , Cross-Sectional Studies , Female , Follow-Up Studies , Humans , Incidence , Middle Aged , Norway/epidemiology , Postmenopause , Premenopause , Prognosis , Risk Factors
15.
J Clin Pathol ; 70(4): 313-319, 2017 Apr.
Article in English | MEDLINE | ID: mdl-27612505

ABSTRACT

AIMS: Vascular invasion in breast cancer is associated with increased risk of recurrence, metastases and death from disease. However, there are few studies discriminating between blood vessel invasion (BVI) and lymphatic vessel involvement (LVI). METHODS: A population-based series of 282 breast cancers was examined (200 screen-detected and 82 interval patients) with respect to BVI and LVI in addition to basic features and molecular subtypes, using CD31 and D2-40 antibodies. This series is part of the prospective Norwegian Breast Cancer Screening Program. RESULTS: The frequency of LVI and BVI was 25% and 15%, respectively. BVI was associated with HER2-positive and basal-like tumours, and several features of aggressive breast cancer, whereas LVI showed weaker associations. BVI was the strongest factor to predict interval cancer presentation. BVI showed significant associations with recurrence-free survival and disease-specific survival in univariate and multivariate analyses, whereas LVI was not significant. CONCLUSIONS: Our findings indicate that BVI by tumour cells is strongly associated with aggressive tumour features including a basal-like phenotype, and BVI was an independent prognostic factor in contrast to what was found for LVI.


Subject(s)
Breast Neoplasms/pathology , Neoplasm Invasiveness/pathology , Aged , Biomarkers, Tumor/analysis , Breast Neoplasms/mortality , Female , Humans , Immunohistochemistry , Kaplan-Meier Estimate , Middle Aged , Phenotype , Prognosis , Proportional Hazards Models , Tissue Array Analysis
16.
Eur Radiol ; 27(7): 2737-2743, 2017 Jul.
Article in English | MEDLINE | ID: mdl-27807699

ABSTRACT

EUSOBI and 30 national breast radiology bodies support mammography for population-based screening, demonstrated to reduce breast cancer (BC) mortality and treatment impact. According to the International Agency for Research on Cancer, the reduction in mortality is 40 % for women aged 50-69 years taking up the invitation while the probability of false-positive needle biopsy is <1 % per round and overdiagnosis is only 1-10 % for a 20-year screening. Mortality reduction was also observed for the age groups 40-49 years and 70-74 years, although with "limited evidence". Thus, we firstly recommend biennial screening mammography for average-risk women aged 50-69 years; extension up to 73 or 75 years, biennially, is a second priority, from 40-45 to 49 years, annually, a third priority. Screening with thermography or other optical tools as alternatives to mammography is discouraged. Preference should be given to population screening programmes on a territorial basis, with double reading. Adoption of digital mammography (not film-screen or phosphor-plate computer radiography) is a priority, which also improves sensitivity in dense breasts. Radiologists qualified as screening readers should be involved in programmes. Digital breast tomosynthesis is also set to become "routine mammography" in the screening setting in the next future. Dedicated pathways for high-risk women offering breast MRI according to national or international guidelines and recommendations are encouraged. KEY POINTS: • EUSOBI and 30 national breast radiology bodies support screening mammography. • A first priority is double-reading biennial mammography for women aged 50-69 years. • Extension to 73-75 and from 40-45 to 49 years is also encouraged. • Digital mammography (not film-screen or computer radiography) should be used. • DBT is set to become "routine mammography" in the screening setting in the next future.


Subject(s)
Breast Neoplasms/diagnostic imaging , Early Detection of Cancer/methods , Mammography/methods , Mass Screening/organization & administration , Adult , Aged , Breast Neoplasms/prevention & control , Europe , Female , Humans , Middle Aged , Middle East
18.
Breast Cancer Res Treat ; 132(1): 297-305, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22052325

ABSTRACT

While studies have shown that use of postmenopausal hormone therapy with estrogen and progestogen (EPT) increases mammographic density, aspects of this association remain unclear. We examined whether mammographic density differed by type of hormone therapy (HT) used, dose, duration of use, time since last use, and whether the effects are modified by age and body mass index (BMI). Using a cross-sectional design, we recruited 2,424 postmenopausal women aged 50-69 years participating in the Norwegian Breast Cancer Screening Program. Mammographic density was assessed with a computer-assisted method, and we estimated mean absolute and percent mammographic density through multiple linear regression, and adjusting for possible confounders. Mammographic density was higher among current HT users (percent density: 22.6%; 95% CI: 22.1-23.2%) than among former (17.7%; 17.2-18.2%) or never users (16.3%; 15.7-16.8%). The highest density was seen in current EPT users of high-dose norethisterone acetate (NETA) regimens who had a percent density of 26.2% (24.3-28.1%). Results differed when considering the combined effect of age and BMI. The effect of EPT on mammographic density was modified by age and BMI, with no apparent association among the youngest women (aged 50-55) with the highest BMI (BMI ≥ 26). A higher mammographic density was found in EPT users compared to never HT users, particularly in women using high-dose NETA regimens. Age and BMI modified the association between EPT use and mammographic density.


Subject(s)
Estrogen Replacement Therapy , Mammary Glands, Human/drug effects , Cross-Sectional Studies , Drug Therapy, Combination , Early Detection of Cancer , Estrogens/administration & dosage , Female , Humans , Mammary Glands, Human/anatomy & histology , Mammography , Middle Aged , Norway , Postmenopause , Progesterone Congeners/administration & dosage
19.
Pediatrics ; 125(1): e9-16, 2010 Jan.
Article in English | MEDLINE | ID: mdl-20026501

ABSTRACT

OBJECTIVE: We conducted a blinded, randomized, controlled trial to examine whether mildly dysplastic but stable or instable hips would benefit from early treatment, as compared with watchful waiting. PATIENTS AND METHODS: A total of 128 newborns with mild hip dysplasia (sonographic inclination angle [alpha angle] of 43 degrees -49 degrees ) and stable or instable but not dislocatable hips were randomly assigned to receive either 6 weeks of abduction treatment (immediate-treatment group) or follow-up alone (active-sonographic-surveillance group). The main outcome measurement was the acetabular inclination angle, measured by radiograph, at 1 year of age. RESULTS: Both groups included 64 newborns, and there was no loss to follow-up. With the exception of a small but statistically significant excess of girls in the active-sonographic-surveillance group, there were no statistically significant differences in baseline characteristics between the 2 groups. The mean inclination angle at 12 months was 24.2 degrees for both groups (difference: 0.1 [95% confidence interval (CI): -0.8 to 0.9]), and all children had improved and were without treatment. The mean alpha angle was 59.7 degrees in the treatment group and 57.1 degrees in the active-surveillance group for a difference of 2.6 degrees evaluated after 1.5 and 3 months (95% CI: 1.8 to 3.4; P < .001). At 1.5 months of age, the hips had improved in all treated children but not in 5 children under active surveillance (P = .06). Among the sonographic-surveillance group, 47% received treatment after the initial surveillance period of 1.5 months. CONCLUSIONS: Active-sonographic-surveillance halved the number of children requiring treatment, did not increase the duration of treatment, and yielded similar results at 1-year follow-up. Given a reported prevalence of 1.3% for mildly dysplastic but stable hips, a strategy of active surveillance would reduce the overall treatment rate by 0.6%. Our results may have important implications for families as well as for health care costs.


Subject(s)
Hip Dislocation, Congenital/diagnostic imaging , Hip Dislocation, Congenital/therapy , Motion Therapy, Continuous Passive/methods , Observation/methods , Double-Blind Method , Female , Follow-Up Studies , Hip Dislocation, Congenital/physiopathology , Humans , Infant , Infant, Newborn , Male , Probability , Range of Motion, Articular , Recovery of Function , Reference Values , Risk Assessment , Severity of Illness Index , Time Factors , Treatment Outcome , Ultrasonography
20.
Breast ; 16(4): 367-74, 2007 Aug.
Article in English | MEDLINE | ID: mdl-17317184

ABSTRACT

We wanted to compare the sensitivities of breast magnetic resonance imaging (MRI) and the conventional screening programme consisting of mammography (XRM) +/- ultrasound for early diagnosis of breast cancer in BRCA1/2 mutation carriers. BRCA1/2 mutation carriers were examined prospectively by both breast MRI and XRM +/- ultrasound. Eight hundred and sixty-seven MRI examinations were carried out in 445 BRCA1 and 46 BRCA2 mutation carriers. A total of 25 cancers were observed, five (20%) as interval cancers. At the time of diagnosis, sensitivity to detect cancer was 19/22=86% for MRI and 12/24=50% for XRM. Twenty-one were examined by both methods at the time of diagnosis. In the19 BRCA1 mutation carriers among them, MRI had a sensitivity of 1/3(33%) to diagnose DCIS and 15/16 (94%) among the invasive cancers. For XRM the sensitivities were 1/3(33%) for DCIS, 3/7(42%) for pT1b, 3/6(50%) for pT1c, and 3/3/100%) for pT2. In the two BRCA2 mutation carriers, both were demonstrated by breast MRI, neither was detected by XRM. Breast MRI had increased sensitivity compared to XRM to diagnose all cancers staged less than pT2.


Subject(s)
Breast Neoplasms/diagnosis , Magnetic Resonance Imaging , Adult , Aged , Breast Neoplasms/genetics , Breast Neoplasms/pathology , Early Diagnosis , Female , Genes, BRCA1 , Genes, BRCA2 , Humans , Middle Aged , Neoplasm Staging , Norway , Prospective Studies , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...