Results 1 - 20 de 33
Filter
2.
Sci Rep ; 10(1): 21903, 2020 12 14.
Article in English | MEDLINE | ID: mdl-33318547

ABSTRACT

Mechanical ventilation is the standard treatment when volitional breathing is insufficient, but drawbacks include muscle atrophy, alveolar damage, and reduced mobility. Respiratory pacing is an alternative approach using electrical stimulation-induced diaphragm contraction to ventilate the lung. Oxygenation and acid-base homeostasis are maintained by matching ventilation to metabolic needs; however, current pacing technology requires manual tuning and does not respond to dynamic user-specific metabolic demand, thus requiring re-tuning of stimulation parameters as physiological changes occur. Here, we describe respiratory pacing using a closed-loop adaptive controller that can self-adjust in real-time to meet metabolic needs. The controller uses an adaptive Pattern Generator Pattern Shaper (PG/PS) architecture that autonomously generates a desired ventilatory pattern in response to dynamic changes in arterial CO2 levels and, based on a learning algorithm, modulates stimulation intensity and respiratory cycle duration to evoke this ventilatory pattern. In vivo experiments in rats with respiratory depression and in those with a paralyzed hemidiaphragm confirmed that the controller can adapt and control ventilation to ameliorate hypoventilation and restore normocapnia regardless of the cause of respiratory dysfunction. This novel closed-loop bioelectronic controller advances the state-of-art in respiratory pacing by demonstrating the ability to automatically personalize stimulation patterns and adapt to achieve adequate ventilation.


Subject(s)
Algorithms , Electric Stimulation Therapy , Lung/physiopathology , Respiration , Animals , Male , Rats , Rats, Sprague-Dawley , Respiration, Artificial
3.
Sensors (Basel) ; 20(22)2020 Nov 10.
Article in English | MEDLINE | ID: mdl-33182658

ABSTRACT

Spatiotemporal parameters of gait serve as an important biomarker to monitor gait impairments as well as to develop rehabilitation systems. In this work, we developed a computationally-efficient algorithm (SDI-Step) that uses segmented double integration to calculate step length and step time from wearable inertial measurement units (IMUs) and assessed its ability to reliably and accurately measure spatiotemporal gait parameters. Two data sets that included simultaneous measurements from wearable sensors and from a laboratory-based system were used in the assessment. The first data set utilized IMU sensors and a GAITRite mat in our laboratory to monitor gait in fifteen participants: 9 young adults (YA1) (5 females, 4 males, age 23.6 ± 1 years), and 6 people with Parkinson's disease (PD) (3 females, 3 males, age 72.3 ± 6.6 years). The second data set, which was accessed from a publicly-available repository, utilized IMU sensors and an optoelectronic system to monitor gait in five young adults (YA2) (2 females, 3 males, age 30.5 ± 3.5 years). In order to provide a complete representation of validity, we used multiple statistical analyses with overlapping metrics. Gait parameters such as step time and step length were calculated and the agreement between the two measurement systems for each gait parameter was assessed using Passing-Bablok (PB) regression analysis and calculation of the Intra-class Correlation Coefficient (ICC (2,1)) with 95% confidence intervals for a single measure, absolute-agreement, 2-way mixed-effects model. In addition, Bland-Altman (BA) plots were used to visually inspect the measurement agreement. The values of the PB regression slope were close to 1 and intercept close to 0 for both step time and step length measures. The results obtained using ICC (2,1) for step length showed a moderate to excellent agreement for YA (between 0.81 and 0.95) and excellent agreement for PD (between 0.93 and 0.98), while both YA and PD had an excellent agreement in step time ICCs (>0.9). Finally, examining the BA plots showed that the measurement difference was within the limits of agreement (LoA) with a 95% probability. Results from this preliminary study indicate that using the SDI-Step algorithm to process signals from wearable IMUs provides measurements that are in close agreement with widely-used laboratory-based systems and can be considered as a valid tool for measuring spatiotemporal gait parameters.


Subject(s)
Gait Analysis/instrumentation , Parkinson Disease/rehabilitation , Wearable Electronic Devices , Adult , Aged , Algorithms , Female , Humans , Male , Parkinson Disease/diagnosis , Reproducibility of Results , Young Adult
4.
J Thorac Dis ; 12(8): 4299-4306, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32944342

ABSTRACT

BACKGROUND: The Nuss procedure temporarily places intrathoracic bars for repair of pectus excavatum (PE). The bars may impact excursion and compliance of the anterior chest wall while in place. Effective chest compressions during cardiopulmonary resuscitation (CPR) require depressing the anterior chest wall enough to compress the heart between sternum and spine. We assessed the force required to perform the American Heart Association's recommended chest compression depth after Nuss repair. METHODS: A lumped element elastic model was developed to simulate the relationship between chest compression forces and displacement with focus on the amount of force required to achieve a depth of 5 cm in the presence of 1-3 Nuss bars. Literature review was conducted for evidence supporting potential use of active abdominal compressions and decompression (AACD) as an alternative method of CPR. RESULTS: The presence of bars notably lowered compression depth by a minimum of 69% compared to a chest without bar(s). The model also demonstrated a dramatic increase (minimum of 226%) in compressive forces required to achieve recommended 5 cm depth. Literature review suggests AACD could be an alternative CPR in patients with Nuss bar(s). CONCLUSIONS: In our model, Nuss bars limited the ability to perform chest compressions due to increased force required to achieve a 5 cm compression. The greater the number of Nuss bars present the greater the force required. This may prevent effective CPR. Use of active abdominal compressions and decompressions should be studied further as an alternative resuscitation modality for patients after the Nuss procedure.

5.
Bioelectron Med (Lond) ; 2(3): 123-126, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32440364

ABSTRACT

In this interview, we spoke with Ranu and James at SfN Neuroscience (19-23 October 2019, Chicago, IL, USA) to discover more about their collaboration on a clinical trial aiming to improve the lives of American veterans and service members who have lost limbs. The clinical trial involves the adaptive neural systems neural-enabled prosthetic hand system [1,2].

6.
Contemp Clin Trials Commun ; 17: 100513, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32211555

ABSTRACT

The main motor impairments of gait and balance experienced by people with Parkinson's disease (PD) contribute to a sedentary lifestyle, resulting in poor physical conditioning, loss of functional independence, and reduced quality of life. Despite the known benefits of physical activity in PD, the majority of older adults with PD are insufficiently active. Few studies incorporate behavioral change approaches to promoting physical activity in PD. The main goal of this research is to foster community mobility in older adults with PD by promoting physical activity and improving gait patterns using a theory-based behavioral change intervention. The ReadySteady intervention combines wellness motivation theory with polestriding physical activity, which has been shown to be beneficial for people with PD. The intervention will be tested using a randomized controlled design, including inactive older adults diagnosed with PD. Participants will be randomly assigned the 12-week ReadySteady intervention, 12-week polestriding, and education intervention, or 12-week education intervention. Thirty-six older adults with PD will participate in each of the interventions. Level of physical activity, clinical scores, quantitative measures of gait and balance control, and motivational variables for each intervention will be measured at three time points: pre-intervention, post-intervention (12 weeks), and follow-up (24 weeks). If the intervention is beneficial, it may serve as a sustainable addition to current practice in health promotion efforts serving the PD population.

7.
Sensors (Basel) ; 19(24)2019 Dec 11.
Article in English | MEDLINE | ID: mdl-31835870

ABSTRACT

Progressive gait dysfunction is one of the primary motor symptoms in people with Parkinson's disease (PD). It is generally expressed as reduced step length and gait speed and as increased variability in step time and step length. People with PD also exhibit stooped posture which disrupts gait and impedes social interaction. The gait and posture impairments are usually resistant to the pharmacological treatment, worsen as the disease progresses, increase the likelihood of falls, and result in higher rates of hospitalization and mortality. These impairments may be caused by perceptual deficiencies (poor spatial awareness and loss of temporal rhythmicity) due to the disruptions in processing intrinsic information related to movement initiation and execution which can result in misperceptions of the actual effort required to perform a desired movement and maintain a stable posture. Consequently, people with PD often depend on external cues during execution of motor tasks. Numerous studies involving open-loop cues have shown improvements in gait and freezing of gait (FoG) in people with PD. However, the benefits of cueing may be limited, since cues are provided in a consistent/rhythmic manner irrespective of how well a person follows them. This limitation can be addressed by providing feedback in real-time to the user about performance (closed-loop cueing) which may help to improve movement patterns. Some studies that used closed-loop cueing observed improvements in gait and posture in PD, but the treadmill-based setup in a laboratory would not be accessible outside of a research setting, and the skills learned may not readily and completely transfer to overground locomotion in the community. Technologies suitable for cueing outside of laboratory environments could facilitate movement practice during daily activities at home or in the community and could strongly reinforce movement patterns and improve clinical outcomes. This narrative review presents an overview of cueing paradigms that have been utilized to improve gait and posture in people with PD and recommends development of closed-loop wearable systems that can be used at home or in the community to improve gait and posture in PD.


Subject(s)
Gait Disorders, Neurologic/physiopathology , Gait/physiology , Parkinson Disease/physiopathology , Posture/physiology , Aged , Cognition/physiology , Gait Disorders, Neurologic/rehabilitation , Humans , Parkinson Disease/rehabilitation
8.
J Neurotrauma ; 36(24): 3363-3377, 2019 12 15.
Article in English | MEDLINE | ID: mdl-31146654

ABSTRACT

Ventilatory pacing by electrical stimulation of the phrenic nerve or of the diaphragm has been shown to enhance quality of life compared to mechanical ventilation. However, commercially available ventilatory pacing devices require initial manual specification of stimulation parameters and frequent adjustment to achieve and maintain suitable ventilation over long periods of time. Here, we have developed an adaptive, closed-loop, neuromorphic, pattern-shaping controller capable of automatically determining a suitable stimulation pattern and adapting it to maintain a desired breath-volume profile on a breath-by-breath basis. The system adapts the pattern of stimulation parameters based on the error between the measured volume sampled every 40 ms and a desired breath volume profile. In vivo studies in anesthetized male Sprague-Dawley rats without and with spinal cord injury by spinal hemisection at C2 indicated that the controller was capable of automatically adapting stimulation parameters to attain a desired volume profile. Despite diaphragm hemiparesis, the controller was able to achieve a desired volume in the injured animals that did not differ from the tidal volume observed before injury (p = 0.39). Closed-loop adaptive pacing partially mitigated hypoventilation as indicated by reduction of end-tidal CO2 values during pacing. The closed-loop controller was developed and parametrized in a computational testbed before in vivo assessment. This bioelectronic technology could serve as an individualized and autonomous respiratory pacing approach for support or recovery from ventilatory deficiency.


Subject(s)
Diaphragm/physiology , Pulmonary Ventilation/physiology , Respiration, Artificial/methods , Spinal Cord Injuries/physiopathology , Animals , Cervical Vertebrae/injuries , Diaphragm/innervation , Male , Phrenic Nerve/physiology , Rats , Rats, Sprague-Dawley , Respiration, Artificial/instrumentation , Spinal Cord Injuries/therapy , Tidal Volume/physiology
9.
PLoS One ; 14(1): e0210956, 2019.
Article in English | MEDLINE | ID: mdl-30650161

ABSTRACT

Current myoelectric prosthetic limbs are limited in their ability to provide direct sensory feedback to users, which increases attentional demands and reliance on visual cues. Vibrotactile sensory substitution (VSS), which can be used to provide sensory feedback in a non-invasive manner has demonstrated some improvement in myoelectric hand control. In this work, we developed and tested two VSS configurations: one with a single burst-rate modulated actuator and another with a spatially distributed array of five coin tactors. We performed a direct comparative assessment of these two VSS configurations with able-bodied subjects to investigate sensory perception, myoelectric control of grasp force and hand aperture with a prosthesis, and the effects of interface compliance. Six subjects completed a sensory perception experiment under a stimulation only paradigm; sixteen subjects completed experiments to compare VSS performance on perception and graded myoelectric control during grasp force and hand aperture tasks; and ten subjects completed experiments to investigate the effect of mechanical compliance of the myoelectric hand on the ability to control grasp force. Results indicated that sensory perception of vibrotactile feedback was not different for the two VSS configurations in the absence of active myoelectric control, but it was better with feedback from the coin tactor array than with the single actuator during myoelectric control of grasp force. Graded myoelectric control of grasp force and hand aperture was better with feedback from the coin tactor array than with the single actuator, and myoelectric control of grasp force was improved with a compliant grasp interface. Further investigations with VSS should focus on the use of coin tactor arrays by subjects with amputation in real-world settings and on improving control of grasp force by increasing the mechanical compliance of the hand.


Subject(s)
Artificial Limbs , Feedback, Sensory/physiology , Hand Strength/physiology , Hand/physiology , Touch/physiology , Adult , Amputation, Surgical , Amputees , Biomechanical Phenomena , Compliance/physiology , Computer Simulation , Electromyography , Female , Humans , Male , Perception/physiology , Prosthesis Design , Vibration , Young Adult
10.
Bioelectron Med (Lond) ; 1(1): 55-69, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29480906

ABSTRACT

The network of peripheral nerves presents extraordinary potential for modulating and/or monitoring the functioning of internal organs or the brain. The degree to which these pathways can be used to influence or observe neural activity patterns will depend greatly on the quality and specificity of the bionic interface. The anatomical organization, which consists of multiple nerve fibers clustered into fascicles within a nerve bundle, presents opportunities and challenges that may necessitate insertion of electrodes into individual fascicles to achieve the specificity that may be required for many clinical applications. This manuscript reviews the current state-of-the-art in bionic intrafascicular interfaces, presents specific concerns for stimulation and recording, describes key implementation considerations and discusses challenges for future designs of bionic intrafascicular interfaces.

11.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 1970-1973, 2017 Jul.
Article in English | MEDLINE | ID: mdl-29060280

ABSTRACT

Functional Electrical Stimulation can be used to restore motor functions loss consecutive to spinal cord injury, such as respiratory deficiency due to paralysis of ventilatory muscles. This paper presents a fully configurable IC-centered stimulator designed to investigate muscle stimulation paradigms. It provides 8 current stimulation channels with high-voltage compliance and real-time operation capabilities, to enable a wide range of FES applications. The stimulator can be used in a standalone mode, or within a closed-loop setup. Primary in vivo results show successful drive of respiratory muscles stimulation using a computer-based dedicated controller.


Subject(s)
Respiratory Muscles , Electric Stimulation , Electric Stimulation Therapy , Humans , Paralysis , Spinal Cord Injuries
12.
Bioinspir Biomim ; 12(1): 016015, 2017 01 30.
Article in English | MEDLINE | ID: mdl-28134133

ABSTRACT

Locomotion requires coordination of leg joints to maintain stability and to maneuver. We studied leg joint function during constant-average-velocity running and the sagittal-plane maneuvers of step ascent and descent. We tested two hypotheses: (1) that leg joints perform distinct functions during locomotion; and (2) that humans select functional parameters to maximize intrinsic dynamic stability. We recorded whole-body kinematics and forces when participants stepped up or down a single vertical step, and found that leg joints show functional differences during both constant-average-velocity locomotion and maneuvers. The hip, knee and ankle function as a motor, damper, and spring, respectively. We therefore constructed a simplified computational model of a human leg with a motor, damper, and spring in series (MDS). The intrinsic dynamics of the model resulted in sustained locomotion on level ground within narrow parameter ranges. However, using parameters experimentally derived from humans, the model showed only short-term stability. Humans may not optimize intrinsic dynamic stability alone, but may instead choose mechanical and behavioral parameters appropriate for both constant-average-velocity locomotion and maneuvers. Understanding joint-level mechanical function during unsteady locomotion helps to understand how differential joint function contributes to whole-body performance, and could lead to improvements in rehabilitation, prosthetic and robotic design.


Subject(s)
Ankle Joint/physiology , Hip Joint/physiology , Knee Joint/physiology , Running/physiology , Adult , Analysis of Variance , Biomechanical Phenomena , Humans , Leg , Locomotion/physiology , Male , Terminology as Topic
13.
Nanobiomedicine (Rij) ; 4: 1849543517701158, 2017.
Article in English | MEDLINE | ID: mdl-29942391

ABSTRACT

In the two decades after 1990, the rates of child and maternal mortality dropped by over 40% and 47%, respectively. Despite these improvements, which are in part due to increased access to medical technologies, profound health disparities exist. In 2015, a child born in a developing region is nearly eight times as likely to die before the age of 5 than one born in a developed region and developing regions accounted for nearly 99% of the maternal deaths. Recent developments in nanotechnology, however, have great potential to ameliorate these and other health disparities by providing new cost-effective solutions for diagnosis or treatment of a variety of medical conditions. Affordability is only one of the several challenges that will need to be met to translate new ideas into a medical product that addresses a global health need. This article aims to describe some of the other challenges that will be faced by nanotechnologists who seek to make an impact in low-resource settings across the globe.

14.
Arch Phys Med Rehabil ; 98(4): 613-621, 2017 04.
Article in English | MEDLINE | ID: mdl-27984031

ABSTRACT

OBJECTIVE: To evaluate the effects of 12-week polestriding intervention on gait and disease severity in people with mild to moderate Parkinson disease (PD). DESIGN: A-B-A withdrawal study design. SETTING: Outpatient movement disorder center and community facility. PARTICIPANTS: Individuals (N=17; 9 women [53%] and 8 men [47%]; mean age, 63.7±4.9y; range, 53-72y) with mild to moderate PD according to United Kingdom brain bank criteria with Hoehn & Yahr score ranging from 2.5 to 3.0 with a stable medication regimen and ability to tolerate "off" medication state. INTERVENTIONS: Twelve-week polestriding intervention with 12-week follow-up. MAIN OUTCOME MEASURES: Gait was evaluated using several quantitative temporal, spatial, and variability measures. In addition, disease severity was assessed using clinical scales such as Unified Parkinson's Disease Rating Scale (UPDRS), Hoehn & Yahr scale, and Parkinson's Disease Questionnaire-39. RESULTS: Step and stride lengths, gait speed, and step-time variability were improved significantly (P<.05) because of 12-week polestriding intervention. Also, the UPDRS motor score, the UPDRS axial score, and the scores of UPDRS subscales on walking and balance improved significantly after the intervention. CONCLUSIONS: Because increased step-time variability and decreased step and stride lengths are associated with PD severity and an increased risk of falls in PD, the observed improvements suggest that regular practice of polestriding may reduce the risk of falls and improve mobility in people with PD.


Subject(s)
Exercise Therapy/methods , Gait Disorders, Neurologic/rehabilitation , Parkinson Disease/rehabilitation , Accidental Falls/prevention & control , Aged , Disability Evaluation , Female , Gait Disorders, Neurologic/physiopathology , Humans , Male , Middle Aged , Parkinson Disease/physiopathology , Postural Balance/physiology , Quality of Life , Risk Factors , Treatment Outcome
15.
Gait Posture ; 51: 91-96, 2017 01.
Article in English | MEDLINE | ID: mdl-27728877

ABSTRACT

We developed and evaluated properties of a new measure of variability in stride length and cadence, termed residual standard deviation (RSD). To calculate RSD, stride length and cadence are regressed against velocity to derive the best fit line from which the variability (SD) of the distance between the actual and predicted data points is calculated. We examined construct, concurrent, and discriminative validity of RSD using dual-task paradigm in 14 below-knee prosthesis users and 13 age- and education-matched controls. Subjects walked first over an electronic walkway while performing separately a serial subtraction and backwards spelling task, and then at self-selected slow, normal, and fast speeds used to derive the best fit line for stride length and cadence against velocity. Construct validity was demonstrated by significantly greater increase in RSD during dual-task gait in prosthesis users than controls (group-by-condition interaction, stride length p=0.0006, cadence p=0.009). Concurrent validity was established against coefficient of variation (CV) by moderate-to-high correlations (r=0.50-0.87) between dual-task cost RSD and dual-task cost CV for both stride length and cadence in prosthesis users and controls. Discriminative validity was documented by the ability of dual-task cost calculated from RSD to effectively differentiate prosthesis users from controls (area under the receiver operating characteristic curve, stride length 0.863, p=0.001, cadence 0.808, p=0.007), which was better than the ability of dual-task cost CV (0.692, 0.648, respectively, not significant). These results validate RSD as a new measure of variability in below-knee prosthesis users. Future studies should include larger cohorts and other populations to ascertain its generalizability.


Subject(s)
Artificial Limbs , Gait , Knee Prosthesis/economics , Walking , Adolescent , Adult , Aged , Aged, 80 and over , Biomechanical Phenomena , Female , Humans , Male , Middle Aged , Reproducibility of Results , Task Performance and Analysis , Young Adult
16.
Front Neurosci ; 10: 275, 2016.
Article in English | MEDLINE | ID: mdl-27378844

ABSTRACT

Cervical spinal cord injury can disrupt connections between the brain respiratory network and the respiratory muscles which can lead to partial or complete loss of ventilatory control and require ventilatory assistance. Unlike current open-loop technology, a closed-loop diaphragmatic pacing system could overcome the drawbacks of manual titration as well as respond to changing ventilation requirements. We present an original bio-inspired assistive technology for real-time ventilation assistance, implemented in a digital configurable Field Programmable Gate Array (FPGA). The bio-inspired controller, which is a spiking neural network (SNN) inspired by the medullary respiratory network, is as robust as a classic controller while having a flexible, low-power and low-cost hardware design. The system was simulated in MATLAB with FPGA-specific constraints and tested with a computational model of rat breathing; the model reproduced experimentally collected respiratory data in eupneic animals. The open-loop version of the bio-inspired controller was implemented on the FPGA. Electrical test bench characterizations confirmed the system functionality. Open and closed-loop paradigm simulations were simulated to test the FPGA system real-time behavior using the rat computational model. The closed-loop system monitors breathing and changes in respiratory demands to drive diaphragmatic stimulation. The simulated results inform future acute animal experiments and constitute the first step toward the development of a neuromorphic, adaptive, compact, low-power, implantable device. The bio-inspired hardware design optimizes the FPGA resource and time costs while harnessing the computational power of spike-based neuromorphic hardware. Its real-time feature makes it suitable for in vivo applications.

17.
IEEE J Biomed Health Inform ; 19(6): 1809-19, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26316235

ABSTRACT

For people with Parkinson's disease (PD), gait and postural impairments can significantly affect their ability to perform activities of daily living. Presentation of appropriate cues has been shown to improve gait in PD. Based on this, a treadmill-based system and experimental paradigm were developed to determine if people with PD can utilize real-time feedback (RTFB) of step length or back angle (uprightness) to improve gait and posture. Eleven subjects (mean age 67 ± 8 years) with mild-to-moderate PD (Hoehn and Yahr stage I-III) were evaluated regarding their ability to successfully utilize RTFB of back angle or step length during quiet standing and treadmill walking tasks during a single session in their medication-on state. Changes in back angle and step length due to feedback were compared using Friedman nonparametric tests with Wilcoxon Signed-Rank tests for post-hoc comparisons. Improvements in uprightness were observed as an increase in back angle during quiet standing (p = 0.005) and during treadmill walking (p = 0.005) with back angle feedback when compared to corresponding tasks without feedback. Improvements in gait were also observed as an increase in step length (p = 0.005) during step length feedback compared to tasks without feedback. These results indicate that people with mild-to-moderate PD can utilize RTFB to improve upright posture and gait. Future work will investigate the long-term effects of this RTFB paradigm and the development of systems for clinical or home-based use.


Subject(s)
Feedback , Gait/physiology , Monitoring, Physiologic/methods , Parkinson Disease/physiopathology , Posture/physiology , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Monitoring, Physiologic/instrumentation , Signal Processing, Computer-Assisted
18.
J Neurophysiol ; 113(7): 2666-75, 2015 Apr 01.
Article in English | MEDLINE | ID: mdl-25673734

ABSTRACT

Spinal cord injury (SCI) can lead to changes in muscle activation patterns and atrophy of affected muscles. Moderate levels of SCI are typically associated with foot drag during the swing phase of locomotion. Foot drag is often used to assess locomotor recovery, but the causes remain unclear. We hypothesized that foot drag results from inappropriate muscle coordination preventing flexion at the stance-to-swing transition. To test this hypothesis and to assess the relative contributions of neural and muscular changes on foot drag, we developed a two-dimensional, one degree of freedom ankle musculoskeletal model with gastrocnemius and tibialis anterior muscles. Anatomical data collected from sham-injured and incomplete SCI (iSCI) female Long-Evans rats as well as physiological data from the literature were used to implement an open-loop muscle dynamics model. Muscle insertion point motion was calculated with imposed ankle trajectories from kinematic analysis of treadmill walking in sham-injured and iSCI animals. Relative gastrocnemius deactivation and tibialis anterior activation onset times were varied within physiologically relevant ranges based on simplified locomotor electromyogram profiles. No-atrophy and moderate muscle atrophy as well as normal and injured muscle activation profiles were also simulated. Positive moments coinciding with the transition from stance to swing phase were defined as foot swing and negative moments as foot drag. Whereas decreases in activation delay caused by delayed gastrocnemius deactivation promote foot drag, all other changes associated with iSCI facilitate foot swing. Our results suggest that even small changes in the ability to precisely deactivate the gastrocnemius could result in foot drag after iSCI.


Subject(s)
Ankle/physiopathology , Gait Disorders, Neurologic/physiopathology , Models, Biological , Muscle Contraction , Muscle, Skeletal/physiopathology , Spinal Cord Injuries/physiopathology , Adaptation, Physiological , Animals , Computer Simulation , Female , Gait , Gait Disorders, Neurologic/etiology , Muscular Atrophy/etiology , Muscular Atrophy/physiopathology , Rats , Rats, Long-Evans , Spinal Cord Injuries/complications
19.
J Neurosci Methods ; 244: 78-84, 2015 Apr 15.
Article in English | MEDLINE | ID: mdl-25092497

ABSTRACT

BACKGROUND: Several neural interface technologies that stimulate and/or record from groups of axons have been developed. The longitudinal intrafascicular electrode (LIFE) is a fine wire that can provide access to a discrete population of axons within a peripheral nerve fascicle. Some applications require, or would benefit greatly from, technology that could provide access to multiple discrete sites in several fascicles. NEW METHOD: The distributed intrafascicular multi-electrode (DIME) lead was developed to deploy multiple LIFEs to several fascicles. It consists of several (e.g. six) LIFEs that are coiled and placed in a sheath for strength and durability, with a portion left uncoiled to allow insertion at distinct sites. We have also developed a multi-lead multi-electrode (MLME) management system that includes a set of sheaths and procedures for fabrication and deployment. RESULTS: A prototype with 3 DIME leads was fabricated and tested in a procedure in a cadaver arm. The leads were successfully routed through skin and connective tissue and the deployment procedures were utilized to insert the LIFEs into fascicles of two nerves. COMPARISON WITH EXISTING METHOD(S): Most multi-electrode systems use a single-lead, multi-electrode design. For some applications, this design may be limited by the bulk of the multi-contact array and/or by the spatial distribution of the electrodes. CONCLUSION: We have designed a system that can be used to access multiple sets of discrete groups of fibers that are spatially distributed in one or more fascicles of peripheral nerves. This system may be useful for neural-enabled prostheses or other applications.


Subject(s)
Action Potentials/physiology , Axons/physiology , Neural Prostheses , Peripheral Nerves/physiology , Animals , Electric Stimulation , Electrodes , Equipment Design , Humans , User-Computer Interface
20.
Front Neurosci ; 8: 371, 2014.
Article in English | MEDLINE | ID: mdl-25452711

ABSTRACT

Decoding motor intent from recorded neural signals is essential for the development of effective neural-controlled prostheses. To facilitate the development of online decoding algorithms we have developed a software platform to simulate neural motor signals recorded with peripheral nerve electrodes, such as longitudinal intrafascicular electrodes (LIFEs). The simulator uses stored motor intent signals to drive a pool of simulated motoneurons with various spike shapes, recruitment characteristics, and firing frequencies. Each electrode records a weighted sum of a subset of simulated motoneuron activity patterns. As designed, the simulator facilitates development of a suite of test scenarios that would not be possible with actual data sets because, unlike with actual recordings, in the simulator the individual contributions to the simulated composite recordings are known and can be methodically varied across a set of simulation runs. In this manner, the simulation tool is suitable for iterative development of real-time decoding algorithms prior to definitive evaluation in amputee subjects with implanted electrodes. The simulation tool was used to produce data sets that demonstrate its ability to capture some features of neural recordings that pose challenges for decoding algorithms.