Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Oral Health ; 24(1): 113, 2024 Jan 19.
Article in English | MEDLINE | ID: mdl-38243249

ABSTRACT

PURPOSE: To investigate the effect of different occlusal reduction design on stress distribution and fracture resistance of different endocrown systems. MATERIAL AND METHODS: Sixty-four maxillary human premolars with endodontic treatment, prepared for endocrowns were divided into 2 groups (n = 32) according to the occlusal design: Butt joint preparation (B group) and Anatomical preparation (A group). Each group were subdivided into four groups according to ceramic systems: IPS E max CAD (EM group), monolithic zirconia (ZR group), Nacera Hyprid (NH group) and PEKKTON (PE group). After manufacturing of endocrowns and adhesive bonding the specimens were thermomechanically loaded and subsequently they were tested in a universal testing machine for evaluating the fracture resistance. The specimens failure mode was qualitatively assessed. The stress distribution in each group was assessed using three-dimensional finite element analysis (FEA). 1-way ANOVA and the Post Hoc Tukey HSD test were used to evaluate the data (a = .05). RESULTS: The fracture resistance values between the groups showed statistically significant variations. The B PE and A PE groups had a higher ratio of fracture resistance values. Regarding failure mode, ceramic endocrowns recorded mainly irreparable failures. FEA showed that anatomical occlusal preparation have reduced the stress concentration under all endocrown systems. CONCLUSION: Endocrowns could be used to restore endodontically treated maxillary premolars. PEKKTON endocrowns with anatomical preparations revealed most appropriate restoration. The tested new endocrown systems enhanced the biomechanical performance of the tooth. CLINICAL SIGNIFICANCE: The innovative endocrown systems (PEKK, Nacera Hyprid) can be seen as a promising choice for restoration of severely-destructed endodontic treated premolars, with less stress transmit to the residual tooth structure. Although the traditional endocrown technology might increase the longevity of tooth bonding, it shouldn't be used for clenching cases since the risk of failure is too great overall.


Subject(s)
Crowns , Dental Porcelain , Humans , Dental Porcelain/chemistry , Bicuspid , Dental Stress Analysis , Dental Restoration Failure , Ceramics/chemistry , Materials Testing , Computer-Aided Design
2.
BMC Oral Health ; 23(1): 421, 2023 06 25.
Article in English | MEDLINE | ID: mdl-37357307

ABSTRACT

PURPOSE: To assess and compare the impact of various computers aided design/manufacturing (CAD/CAM) materials on internal and marginal discrepancies, fracture resistance and failure probability of Endocrown restorations with 3D Finite Element analysis. MATERIAL AND METHODS: Forty devitalized human maxillary first molars were collected. After endodontic treatment, they classified into 4 groups (n = 10) based on the materials used for endocrown fabrication. Group V (Vita-Enamic), Group N (Nacera Hybrid), Group T (Translucent Prettau Zirconia) and Group P (Pekkton ivory). All samples were exposed to artificial aging method simulating one year of clinical service. Silicone replica technique and stereomicroscope (25X) utilized to evaluate the marginal and internal gaps of endocrowns at different areas. Fracture resistance test used for cemented specimens followed by qualitative investigation utilizing Stereomicroscopy. Four models representing four endocrown systems used for restoration of severely-damaged endodontically treated upper first molar were generated for finite element analysis (FEA). Axially and centrally static occlusal compressive load was applied. Modified Von Mises and maximum principal stress values on the remaining tooth structure, cement lines and restorative materials were assessed independently. Resulted data were statistically analyzed at P-value ≤ 0.05. RESULTS: In the current study, the highest mean values of internal and marginal discrepancies (µm) among studied groups were reported for Zirconia group (100.300 and 102.650) respectively, while the lowest mean value of internal discrepancy (µm) was observed for Nacera group (69.275) and the lowest mean value of marginal discrepancy (µm) was observed for PEKK group (78.4750). Regarding internal discrepancy, Vita-Enamic and PEKK groups did not exhibit any statistically significant differences (P = 0.293), however zirconia and the other tested groups exhibited statistically significant differences in the mean values of the marginal gap region (p 0.05).On the other hand, PEKK group showed the highest mean value of fracture resistance (1845.20 N) and the lowest value was observed for Vita-Enamic group (946.50 N). Regarding to stress distributions through 3D FEA, and according to modified von Mises (mvM) analysis, the greatest possible stress values were noticed in PEKK model in relation to tooth structure, cement line, and flowable composite as the following: (93.1, 64.5, 58.4 MPa) respectively, while Zirconia revealed lower maximum stress values (11.4, 13.6, 11.6 MPa) respectively. CONCLUSIONS: Statistically excellent marginal and internal fit was observed for PEKK in relation to other used endocrown materials. Also, PEKK material explained fracture resistance comparable to zirconia value while the lowest value was detected for Vita Enamic material.


Subject(s)
Ceramics , Crowns , Humans , Finite Element Analysis , Dental Materials/chemistry , Zirconium , Computer-Aided Design , Materials Testing , Dental Stress Analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...