Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Chirality ; 28(1): 49-57, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26527388

ABSTRACT

Rapid and simple isocratic high-performance liquid chromatographic methods with UV detection were developed and validated for the direct resolution of racemic mixtures of hyoscyamine sulfate and zopiclone. The method involved the use of αl -acid glycoprotein (AGP) as chiral stationary phase. The stereochemical separation factor (ά) and the stereochemical resolution factor (Rs ) obtained were 1.29 and 1.60 for hyoscyamine sulfate and 1.47 and 2.45 for zopiclone, respectively. The method was used for determination of chiral switching (eutomer) isomers: S-hyoscyamine sulfate and eszopiclone. Several mobile phase parameters were investigated for controlling enantioselective retention and resolution on the chiral AGP column. The influence of mobile phase, concentration and type of uncharged organic modifier, ionic strength, and column temperature on enantioselectivity were studied. Calibration curves were linear in the ranges of 1-10 µg mL(-1) and 0.5-5 µg mL(-1) for S-hyoscyamine sulfate and eszopiclone, respectively. The method is specific and sensitive, with lower limits of detection and quantifications of 0.156, 0.515 and 0.106, 0.349 for S-hyoscyamine sulfate and eszopiclone, respectively. The method was used to identify quantitatively the enantiomers profile of the racemic mixtures of the studied drugs in their pharmaceutical preparations. Thermodynamic studies were performed to calculate the enthalpic ΔH and entropic ΔS terms. The results showed that enantiomer separation of the studied drugs were an enthalpic process.


Subject(s)
Azabicyclo Compounds/chemistry , Hyoscyamine/chemistry , Indicators and Reagents/chemistry , Piperazines/chemistry , Chromatography, High Pressure Liquid , Stereoisomerism , Thermodynamics
2.
J Sep Sci ; 38(5): 757-63, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25545351

ABSTRACT

The introduction of sustainable development concepts to analytical laboratories has recently gained interest, however, most conventional high-performance liquid chromatography methods do not consider either the effect of the used chemicals or the amount of produced waste on the environment. The aim of this work was to prove that conventional methods can be replaced by greener ones with the same analytical parameters. The suggested methods were designed so that they neither use nor produce harmful chemicals and produce minimum waste to be used in routine analysis without harming the environment. This was achieved by using green mobile phases and short run times. Four mixtures were chosen as models for this study; clidinium bromide/chlordiazepoxide hydrochloride, phenobarbitone/pipenzolate bromide, mebeverine hydrochloride/sulpiride, and chlorphenoxamine hydrochloride/caffeine/8-chlorotheophylline either in their bulk powder or in their dosage forms. The methods were validated with respect to linearity, precision, accuracy, system suitability, and robustness. The developed methods were compared to the reported conventional high-performance liquid chromatography methods regarding their greenness profile. The suggested methods were found to be greener and more time- and solvent-saving than the reported ones; hence they can be used for routine analysis of the studied mixtures without harming the environment.


Subject(s)
Chromatography, High Pressure Liquid/methods , Green Chemistry Technology/methods , Pharmaceutical Preparations/analysis , Chromatography, High Pressure Liquid/instrumentation , Environmental Pollution , Green Chemistry Technology/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...