Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Arthroplast Today ; 12: 17-23, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34761088

ABSTRACT

BACKGROUND: The optimal management strategy for instability afte total hip arthroplasty remains unclear. Acetabular lip augmentation devices may offer an operative solution for recurrent instability. This systematic review reports the clinical outcomes of acetabular lip augmentation devices in comparison to other treatment options. METHODS: A literature search strategy was performed of Medline, EMBASE, and CENTRAL on September 19, 2020, for all studies reporting outcomes of acetabular lip augmentation devices for recurrent dislocation after total hip arthroplasty. Non-English language articles were excluded. Clinical and survivorship data were collated and analyzed. RESULTS: Thirteen studies describing acetabular augmentation were included for analysis. A total of 644 hips in 636 patients were augmented with a mean age of 75 years (39 to 103). Five different augmentation devices were used. The posterior lip augmentation device (PLAD, DePuy) was the most used (406 hips). Overall, acetabular lip augmentation devices had a 10% postoperative dislocation rate at a mean follow-up of 49 months (0.2 to 132). The PLAD had a 3.9% subsequent dislocation rate with a mean follow-up of 51 months (0.2 to 132). Only one study compared the PLAD to a dual-mobility cup, which demonstrated shorter operative times with the PLAD but higher rates of dislocation and revision surgery. CONCLUSION: The quality of literature on lip acetabular augmentation devices is poor. In these studies, the postoperative dislocation rate after lip acetabular augmentation was relatively high. The PLAD (DePuy) has the most evidence and may offer a therapeutic option for recurrent instability, in very specific clinical situations.

2.
J Bone Joint Surg Am ; 103(12): e47, 2021 06 16.
Article in English | MEDLINE | ID: mdl-33543881

ABSTRACT

BACKGROUND: Parents are increasingly turning to the internet to seek pediatric health information. Numerous organizations advise that patient educational materials (PEMs) should not surpass the sixth-grade reading level. We aimed to assess the readability of online pediatric orthopaedic PEMs. METHODS: The readability of 176 articles pertaining to pediatric orthopaedics from the American Academy of Orthopaedic Surgeons (AAOS), Pediatric Orthopaedic Society of North America (POSNA), and American Academy of Pediatrics (AAP) websites was assessed with the use of 8 readability formulae: the Flesch-Kincaid Reading Grade Level, the Flesch Reading Ease Score, the Raygor Estimate, the SMOG, the Coleman-Liau, the Fry, the FORCAST, and the Gunning Fog. The mean reading grade level (RGL) of each article was compared with the sixth and eighth-grade reading levels. The mean RGL of each website's articles also was compared. RESULTS: The cumulative mean RGL was 10.2 (range, 6.6 to 16.0). No articles (0%) were written at the sixth-grade reading level, and only 7 articles (4.0%) were written at or below the eighth-grade reading level. The mean RGL was significantly higher than the sixth-grade (95% confidence interval [CI] for the difference, 4.0 to 4.4; p < 0.001) and eighth-grade (95% CI, 2.0 to 2.4; p < 0.001) reading levels. The mean RGL of articles on the POSNA website was significantly lower than the mean RGL of the articles on the AAOS (95% CI, -1.8 to -1.0; p < 0.001) and AAP (95% CI, -2.9 to -1.1; p < 0.001) websites. CONCLUSIONS: Pediatric orthopaedic PEMs that are produced by the AAOS, the POSNA, and the AAP have readability scores that exceed recommendations. Given the increasing preference of parents and adolescents for online health information, the growing body of online PEMs, and the critical role that health literacy plays in patient outcomes, substantial work is required to address the readability of these materials.


Subject(s)
Comprehension , Health Literacy , Internet , Orthopedics , Patient Education as Topic , Pediatrics , Educational Status , Humans
3.
J Arthroplasty ; 35(11): 3076-3083, 2020 11.
Article in English | MEDLINE | ID: mdl-32631729

ABSTRACT

BACKGROUND: The Internet has become an increasingly popular resource among orthopedic patients for health education. Numerous organisations recommend that patient educational materials (PEMs) should not exceed the 6th grade reading level. Despite this, studies have repeatedly shown the reading grade level (RGL) of PEMs to be too advanced across a range of surgical specialties. We aimed to determine the readability of online hip and knee arthroplasty PEMs. METHODS: The readability of 134 articles pertaining to hip and knee arthroplasty from 5leading worldwide healthcare websites were assessed, using 8 readability formulae; the Flesch-Kincaid Reading Grade Level, the Flesch Reading Ease Score, Raygor Estimate, SMOG, Coleman-Liau, Fry, FORCAST and Gunning Fog. The mean RGL was compared to the 6th and 8thgrade reading level. The mean RGL of each website was also compared. RESULTS: The mean cumulative RGL was 12 (range = 7-16.1). No articles (0%) were written at a 6th grade reading level and only 4 articles (3%) were written at or below the 8th grade reading level. The mean RGL was significantly higher than the 6th (95% CI, 5.62-6.30; P < .0001) and 8th grade reading level (95% CI, 3.63-4.30; P < .0001). There was a significant difference between the RGLs of the 5websites (P = .001). CONCLUSION: Arthroplasty PEMs produced by leading worldwide healthcare organisations have readability scores that are above the recommended levels. Given the imperative role of health literacy in patient outcomes and satisfaction, and the increasing prevalence of Internet use among orthopedic patients, a substantial amount of work needs to be done to improve the readability of these materials.


Subject(s)
Arthroplasty, Replacement, Knee , Health Literacy , Orthopedics , Comprehension , Humans , Internet
4.
J Oncol ; 2019: 9417284, 2019.
Article in English | MEDLINE | ID: mdl-32082379

ABSTRACT

BACKGROUND: Joint-sparing limb salvage surgery (JSLSS) is an advancement in the techniques and concepts of limb salvage surgery, which makes it possible to save not only the limb affected by malignancy but also the adjacent joint and the epiphyseal plate. In the growing child, this procedure is technically demanding due to the availability of small length of bone for implant purchase. Reconstruction options can be biological reconstruction or endoprosthesis; however, the outcome of endoprosthetic reconstruction after joint-sparing resection is not well described in the literature. PURPOSES: (1) To determine the prosthesis survival rates when using customized Joint-Sparing Endoprosthesis (JSE) after juxta-articular resection of bone tumors, (2) to investigate the rates of local recurrence, (3) to evaluate the need for revision surgery, and (4) to compare the outcome of customized JSE with that of joint-sacrificing techniques. METHODS: In our study, joint sparing is defined as any procedure where a custom-made JSE is used in lieu of sacrificing the adjacent joint whenever the length of the remaining bone segment is not enough to accommodate the stem of a modular implant. Twenty-eight patients received JSE, and 31 joints were spared. Their age ranged from 4 to 55 years with a median age of 13 years. Twenty-one patients received surgery for primary reconstruction and 7 patients for revision of failed bone allograft or modular implant. Twenty-four joints are spared in the lower limbs and 7 in the upper limbs. Osteosarcoma was the most common pathological diagnosis (n = 13). Flat surface HA-coated custom JSE was used to spare 15 joints, and short-stemmed custom JSE was used to spare 16 joints. The length of the remaining bone epiphysis for JSE anchorage from the knee and ankle joints was 25-75 mm, median = 45 mm, and the length of the cortical bone remaining for the proximal femur and distal humerus was 5-70 mm, median = 10 mm. RESULTS: Operative time was 2.5 to 4 hours (avg. 3 hr.) The bone resection surface fitted the prosthesis surface with <2 mm difference. Histological examination of all resected specimens shows clear bone resection margins; 2 patients had positive soft tissue margins. At mean follow-up period of 3 years (6 months-10 years), 6 patients developed local and systemic recurrences, three of them had a pathological fracture at the time of diagnosis (P=0.139), and 4 showed a poor response to chemotherapy (P=0.139), and 4 showed a poor response to chemotherapy (. CONCLUSIONS: Whenever this kind of implant is affordable and can be utilized, particularly in younger age groups, JSE may be a good reconstruction option to avoid the use of expandable implants and to avoid the potentially higher revision and complication rates associated with biological reconstruction, as well as the complications of conventional joint-sacrificing implant, mainly dislocations and polyethylene wear and tear.

SELECTION OF CITATIONS
SEARCH DETAIL
...