Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
J Echocardiogr ; 19(4): 232-242, 2021 12.
Article in English | MEDLINE | ID: mdl-34091856

ABSTRACT

BACKGROUND: The 6-min walk test (6MWT) provides prognostic information for patients with interstitial lung disease (ILD). Parameter determined by Doppler echocardiography after the 6MWT (6 MW stress echocardiography) is shown to be a predictor of future development of pulmonary hypertension in patients with connective tissue disease. However, the clinical utility of 6 MW stress echocardiography in predicting cardiopulmonary events in patients with ILD remains unknown. We examined whether parameters determined by 6 MW stress echocardiography independent predictors of adverse events in patients with ILD. METHODS: Echocardiographic examinations were performed in 68 consecutively enrolled patients with ILD (age, 65 ± 10 years, 65% men). A pressure gradient of tricuspid regurgitation (TRPG) and pulmonary vascular resistance (PVRecho) calculated using the following formula [PVRecho = (peak velocity of TR × 10/time-velocity integral of right ventricular outflow (RVOT-VTI)) + 0.16] were measured at baseline and at post 6MWT. Data for parameters of pulmonary functional tests and for 6MWT were collected. RESULTS: During a mean follow-up period of 22 ± 12 months, 22 patients experienced cardiopulmonary events. In univariate analysis, %VC, TRPG, PVRecho, TRPG post 6MWT, and PVRecho post 6MWT were significantly associated with cardiopulmonary events. Multivariate analysis using the Cox proportional hazards model indicated that %VC [hazard ratio (HR): 0.97, p = 0.009] and PVRecho post 6MWT (HR: 1.77, p = 0.004) were independent predictors of cardiopulmonary events in patients with ILD. CONCLUSIONS: In addition to parameters of pulmonary function tests, increased PVRecho post 6MWT is a significant predictor of cardiopulmonary events in patients with ILD. A 6 MW stress echocardiography is useful in assessing the risk of adverse events in patients with ILD.


Subject(s)
Hypertension, Pulmonary , Lung Diseases, Interstitial , Aged , Echocardiography, Stress , Female , Humans , Hypertension, Pulmonary/diagnostic imaging , Lung Diseases, Interstitial/complications , Lung Diseases, Interstitial/diagnostic imaging , Male , Middle Aged , Prognosis , Walking
2.
Anal Bioanal Chem ; 409(27): 6387-6396, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28842768

ABSTRACT

Blood adsorption onto the inside surface of hollow fiber dialysis membranes was investigated by means of time-of-flight secondary ion mass spectrometry (TOF-SIMS) and near-field infrared microscopy (NFIR) in order to evaluate the biocompatibility and permeability of dialysis membranes. TOF-SIMS is useful for the imaging of particular molecules with a high spatial resolution of approximately 100 nm. In contrast, infrared spectra provide quantitative information and NFIR enables analysis with a high spatial resolution of less than 1 µm, which is close to the resolution of TOF-SIMS. A comparison was made of one of the most widely used dialysis membranes made of polysulfone (PSf), that has an asymmetric and inhomogeneous pore structure, and a newly developed asymmetric cellulose triacetate (ATA) membrane that also has an asymmetric pore structure, even though the conventional cellulose triacetate membrane has a symmetric and homogeneous pore structure. As a result, it was demonstrated that blood adsorption on the inside surface of the ATA membrane is more reduced than that on the PSf membrane. Graphical abstract Analysis of blood adsorption on inside surface of hollow fiber membrane.


Subject(s)
Biocompatible Materials/chemistry , Blood Chemical Analysis , Cellulose/analogs & derivatives , Membranes, Artificial , Polymers/chemistry , Renal Dialysis/instrumentation , Sulfones/chemistry , Adsorption , Blood , Cellulose/chemistry , Humans , Infrared Rays , Materials Testing/methods , Microscopy/methods , Permeability , Porosity , Spectrometry, Mass, Secondary Ion/methods
3.
J Cardiol ; 69(5): 756-762, 2017 05.
Article in English | MEDLINE | ID: mdl-27484506

ABSTRACT

BACKGROUND: Deep vein thrombosis (DVT) develops after major orthopedic surgery despite the current use of prophylaxis. DVT frequently develops in the soleal vein (SV) and might develop easily at the site of SV dilatation because of blood flow stasis. However, whether preoperative SV dilatation detected by ultrasonography predicts DVT after major orthopedic surgery remains unknown. OBJECTIVE: We examined whether SV dilatation detected by preoperative ultrasonography predicts DVT after major orthopedic surgery. METHODS: Ultrasonography was performed preoperatively and postoperatively in 243 patients with orthopedic diseases (mean age of 67±13 years, 77% women) who underwent total hip arthroplasty (THA, n=180) or total knee arthroplasty (TKA, n=63). Presence of DVT was diagnosed by ultrasonography and SV diameter ≥10mm was defined as SV dilatation. Patients with preoperative DVT were excluded. RESULTS: Sixty-nine patients (28%) developed postoperative DVT. SV dilatation was found in 24 patients (10%), and 16 (67%) of those patients had postoperative DVT. Multivariate logistic regression analysis showed that female gender [odds ratio (OR): 4.09, p=0.004], TKA (OR: 2.52, p=0.011), and SV dilatation (OR: 6.67, p<0.001), but not presence of comorbidities, medications, or plasma d-dimer value, independently predict postoperative DVT. Subgroup analyses according to the operation site showed that female gender (OR: 3.27, p=0.043) and SV dilatation (OR: 3.72, p=0.022) were independent predictors of postoperative DVT in the THA group. SV dilatation (OR: 12.0, p=0.027) was an independent predictor of postoperative DVT also in the TKA group. CONCLUSIONS: In addition to gender and TKA, SV dilatation detected by ultrasonography is an independent predictor of DVT after major orthopedic surgery. Determination of SV diameter by ultrasonography before major orthopedic surgery is useful for assessing the risk of postoperative DVT.


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Knee/adverse effects , Dilatation, Pathologic/diagnostic imaging , Lower Extremity/diagnostic imaging , Veins/diagnostic imaging , Venous Thrombosis/etiology , Aged , Aged, 80 and over , Female , Humans , Lower Extremity/blood supply , Male , Middle Aged , Postoperative Complications , Preoperative Period , Risk Assessment , Sex Factors , Ultrasonography
4.
J Cardiol ; 68(4): 300-7, 2016 10.
Article in English | MEDLINE | ID: mdl-27032318

ABSTRACT

BACKGROUND: Pulmonary hypertension (PH) is a strong predictor of mortality in patients with interstitial lung disease (ILD). However, patients with ILD often have poor outcomes even in the absence of PH. Pulmonary vascular resistance (PVR) assessed by right heart catheterization is a predictor of mortality in patients with ILD. However, the clinical utility of PVR assessed by Doppler echocardiography (PVRecho) as a predictor of the outcome in patients with ILD remains unclear. The aim of this study was to examine whether PVRecho independently predicts mortality in patients with ILD. METHODS: Echocardiographic examinations were performed in 133 consecutively enrolled patients with ILD (age, 67±9 years; 53% men). Tricuspid annular plane systolic excursion (TAPSE) was measured, and PVRecho was calculated by the following formula: PVRecho=[TRV×10/time-velocity integral of right ventricular outflow (RVOT-VTI)]+0.16. Data for parameters of pulmonary functional tests and for serum biomarkers, which were measured within 3 months before or after the echocardiographic examinations, were collected. RESULTS: During a mean follow-up period of 18±7 months, 13 patients died due to respiratory failure (n=10), heart failure (n=1), or unknown causes (n=2). In univariate analysis, body mass index, idiopathic pulmonary fibrosis, use of an antifibrotic drug (AD), RVOT-VTI, PVRecho, percentage of predicted vital capacity (%VC), percentage of predicted forced expiratory volume in 1second, and percentage of predicted diffusion capacity of the lungs for carbon monoxide (%DLco), but not TAPSE or serum biomarkers, were significantly associated with mortality. Cox proportional hazard multivariate analysis indicated that %VC [hazard ratio (HR): 0.92, p=0.001], use of AD (HR: 4.05, p=0.043), and PVRecho (HR: 3.79, p=0.029) independently predict mortality in patients with ILD. Replacement of %VC with %DLco in the multivariate analysis did not change the results: %DLco (HR: 0.90, p=0.001), use of AD (HR: 7.53, p=0.029), and PVRecho (HR: 3.65, p=0.020). CONCLUSIONS: In addition to parameters of pulmonary function tests and use of AD, increased PVRecho is an independent predictor of mortality in patients with ILD who were evaluated for screening of PH by echocardiography.


Subject(s)
Echocardiography, Doppler , Lung Diseases, Interstitial/mortality , Vascular Resistance , Aged , Female , Follow-Up Studies , Heart Failure/mortality , Humans , Hypertension, Pulmonary/diagnostic imaging , Male , Respiratory Insufficiency/mortality , Vital Capacity
5.
Echocardiography ; 32(12): 1790-801, 2015 Dec.
Article in English | MEDLINE | ID: mdl-25925784

ABSTRACT

BACKGROUND: Whether an intervendor discordance of myocardial velocities determined by tissue Doppler echocardiography (TDE) can be generalized remains unclear. We compared intervendor variabilities of left ventricular (LV) and right ventricular (RV) myocardial velocities among three TDE systems. METHODS: Examinations with TDE were performed in 41 healthy subjects and 11 patients with cardiovascular risk factors (CVR) using α-7 (V1, Hitachi Aloka Medical), Artida (V2, Toshiba Medical Systems), and Vivid E9 (V3, GE Healthcare) on the same day. Peak systolic (s'), early diastolic (e'), and late diastolic (a') myocardial velocities at medial and lateral sites of the mitral annulus and lateral site of the tricuspid annulus were measured using both pulsed-wave TDE and color TDE. Intra-observer and inter-observer variabilities were determined in 10 subjects and test-retest variability in 14 subjects. RESULTS: As for test-retest variability, reproducibilities of LV and RV myocardial velocities determined by pulsed-wave TDE and color TDE were relatively low but comparable between V1, V2, and V3. Myocardial velocities in healthy subjects determined by both pulsed-wave TDE and color TDE were significantly different among the three TDE systems. Myocardial velocities by pulsed-wave TDE in V3 were 2-12% lower (P < 0.05) than those by V2 and 5-14% lower (P < 0.05) than those by V1. Similar differences in myocardial velocities determined by both pulsed-wave TDE and color TDE were found in patients with CVR. CONCLUSIONS: LV and RV myocardial velocities determined by both pulsed-wave TDE and color TDE are vendor dependent, and reproducibility of the myocardial velocities determined by both TDE systems is relatively low.


Subject(s)
Elasticity Imaging Techniques/instrumentation , Stroke Volume , Ventricular Dysfunction/diagnostic imaging , Ventricular Dysfunction/physiopathology , Equipment Design , Equipment Failure Analysis , Humans , Reproducibility of Results , Sensitivity and Specificity
6.
Echocardiography ; 31(5): 597-604, 2014 May.
Article in English | MEDLINE | ID: mdl-25070187

ABSTRACT

BACKGROUND: Inter-vendor discordance in three-dimensional speckle-tracking echocardiography (3DS) remains uncharacterized. We aimed to examine inter-vendor discordance of left ventricular (LV) volumes, and functional parameters and their reproducibilities between two commercially available 3DS systems. METHODS: Echocardiographic examinations with 3DS were performed in 26 healthy subjects (age 34 ± 13 years, 85% men) using a Vivid E9 system (V1) with 4V probe (GE Health Care) and Artida (V2) with PST-25SX probe (Toshiba Medical Systems) on the same day. LV variables and global LV longitudinal, circumferential, radial, and area strains were measured by vendor-specific softwares, 4D strain EchoPAC BT11 (for V1) and 3D WMT (for V2), respectively. Reproducibility of data was assessed by an intra-class correlation coefficient (ICC). RESULTS: The mean time required for 3DS analysis was 5.4 ± 1.5 min for V1, being 21% less than that for V2 (6.8 ± 1.9 min, P < 0.01). Reproducibilities of all LV strains were comparable between V1 (ICC 0.50-0.82) and V2 (ICC 0.51-0.76), except for intra-observer and inter-observer reproducibilities of radial strain being lower in V2 (ICC for V1 0.82 and 0.82 and ICC for V2 0.44 and 0.40, respectively). LV strains in all directions and area were significantly different between V1 and V2, though LV volumes and ejection fraction were comparable. CONCLUSIONS: Global longitudinal, circumferential, and area LV strains are reproducible in both 3DS vendors. However, values of three-dimensional LV strains by 3DS are highly vendor-dependent.


Subject(s)
Algorithms , Echocardiography, Three-Dimensional/methods , Heart Ventricles/diagnostic imaging , Ventricular Function, Left/physiology , Adult , Cross-Sectional Studies , Female , Follow-Up Studies , Heart Ventricles/physiopathology , Humans , Male , ROC Curve , Reproducibility of Results , Retrospective Studies , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...