Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Type of study
Publication year range
1.
J Mal Vasc ; 35(6): 355-8, 2010 Dec.
Article in French | MEDLINE | ID: mdl-20580174

ABSTRACT

Vascular complications following laparoscopic cholecystectomy are less frequent but carry higher morbidity than bile ducts lesions. We report on a 19-year-old patient, who presented a ruptured pseudoaneurysm of the hepatic artery 2 months after laparoscopic cholecystectomy. This case illustrates the alternative of direct transhepatic puncture with exclusive glue embolization in case of endovascular access failure.


Subject(s)
Aneurysm/therapy , Embolization, Therapeutic/methods , Hepatic Artery , Aneurysm/etiology , Cholecystectomy, Laparoscopic/adverse effects , Female , Humans , Liver , Young Adult
2.
J Pharm Pharm Sci ; 4(2): 201-6, 2001.
Article in English | MEDLINE | ID: mdl-11466177

ABSTRACT

PURPOSE: To develop a simple, sensitive and rapid HPLC fluorescence method with single step sample preparation for the determination of glyburide in the human plasma. METHODS: Glyburide and ketoconazole (internal standard) were extracted from the 0.5 mL plasma by addition of 0.5 mL acetonitrile and 50 microL CuSO(4) solution (5% w/v in water). The separation was achieved on the Kingsorb 3 microm, C8 reverse phase column at ambient temperature with a mobile phase consisted of 45% buffer solution (0.05 M NH(4)H(2)P(4)), 40% acetonitrile and 15% methanol adjusted to pH 5.7 by diluted ammonia solution. A fluorescence detector was set at 235 nm excitation wavelength and 354 nm emission wavelengths to monitor eluted components. RESULTS: The internal standard and glyburide eluted at about 6.7 and 9.6 min, respectively at the flow rate of 1 mL/min. The regression equation was established for every calibration curves (5 ng/mL to 400 ng/mL), which resulted in the correlation coefficient of 0.99 or greater. The absolute recovery ranged from 94.32 to 98.12% and the relative recovery ranged from 91.12 to 97.15%. The intraday coefficient of variation (CV) ranged from of 6.52 to 12.35% and interday varied from 6.21 to 16.07%. The limit of quantitation (LOQ) of glyburide was set to five ng/mL. CONCLUSION: This simple, rapid and sensitive method is suitable for pharmacokinetic, bioavailability and biequivalence studies.


Subject(s)
Chromatography, High Pressure Liquid/methods , Glyburide/blood , Antifungal Agents/blood , Biological Availability , Calibration , Fluorescence , Glyburide/analysis , Humans , Hypoglycemic Agents/analysis , Hypoglycemic Agents/blood , Ketoconazole/blood , Reference Standards , Therapeutic Equivalency
SELECTION OF CITATIONS
SEARCH DETAIL
...