PLoS One ; 14(7): e0219021, 2019.
Article in English | MEDLINE | ID: mdl-31276477

ABSTRACT

BACKGROUND: Since 2010, point-of-care (POC) CD4 testing platforms have been introduced in both urban and rural settings to expand access to testing by bringing diagnostic services closer to patients. We conducted an analysis of routinely collected CD4 testing data to determine the invalid result rates associated with POC CD4 testing. METHODS: We analyzed 981,152 CD4 testing records collected from Alere Pima Analyzers between January 2011 and December 2016 across five countries in sub-Saharan Africa. Routinely collected data and programmatic records were used to determine the rate of invalid test results per month, by facility type, and by operator based on cumulative usage during the study period. In addition, frequency of invalid test types and utilization of control beads were assessed. RESULTS: Across the five countries, 75,530 invalid messages were returned, resulting in an overall invalid result rate of 7.7%. The invalid result rate by country ranged from 6.6% to 11.2%. Invalid result rates were consistent across facility types. Invalid result rates were inversely correlated with operator usage: low volume operators (<50 tests over study period) experienced an invalid result rate of 10.2%, while high volume operators (>500 tests over study period) experienced an invalid result rate of 5.5%. Two invalid result types (exposure position control and reagent control) accounted for nearly 50% of invalid results. Routine data showed that control beads were run on 88.3% of days that the device was used. CONCLUSIONS: Our analysis found that the rate of invalid results was consistent across all types of health facilities, indicating that decentralization of POC CD4 testing to lower level health facilities did not exhibit high invalid result rates or increase cartridge wastage. Additionally, invalid result rates were inversely correlated to operator usage, with high-volume operators experiencing lower invalid result rates than low-volume operators. POC CD4 testing can, therefore, be performed in decentralized national testing programs; however, adequate training, quality assurance, routine monitoring, and ongoing mentorship should also be implemented for success.


Subject(s)
HIV Infections/immunology , Point-of-Care Testing , Wireless Technology/instrumentation , Africa South of the Sahara , CD4 Lymphocyte Count , Cross-Sectional Studies , Humans , Public Health , Reproducibility of Results , Retrospective Studies , Rural Health Services
SELECTION OF CITATIONS
SEARCH DETAIL
...