Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
PLoS One ; 17(6): e0269060, 2022.
Article in English | MEDLINE | ID: mdl-35767587

ABSTRACT

Millimetre-wave frequencies are promising for sensitive detection of glucose levels in the blood, where the temperature effect is insignificant. All these features provide the feasibility of continuous, portable, and accurate monitoring of glucose levels. This paper presents a metamaterial-inspired resonator comprising five split-rings to detect glucose levels at 24.9 GHz. The plexiglass case containing blood is modelled on the sensor's surface and the structure is simulated for the glucose levels in blood from 50 mg/dl to 120 mg/dl. The novelty of the sensor is demonstrated by the capability to sense the normal glucose levels at millimetre-wave frequencies. The dielectric characteristics of the blood are modelled by using the Debye parameters. The proposed design can detect small changes in the dielectric properties of blood caused by varying glucose levels. The variation in the transmission coefficient for each glucose level tested in this study is determined by the quality factor and resonant frequency. The sensor presented can detect the change in the quality factor of transmission response up to 2.71/mg/dl. The sensor's performance has also been tested to detect diabetic hyperosmolar syndrome. The sensor showed a linear shift in resonant frequency with the change in glucose levels, and an R2 of 0.9976 was obtained by applying regression analysis. Thus, the sensor can be used to monitor glucose in a normal range as well as at extreme levels.


Subject(s)
Glucose
2.
Micromachines (Basel) ; 11(10)2020 Sep 24.
Article in English | MEDLINE | ID: mdl-32987793

ABSTRACT

The demand for wearable technologies has grown tremendously in recent years. Wearable antennas are used for various applications, in many cases within the context of wireless body area networks (WBAN). In WBAN, the presence of the human body poses a significant challenge to the wearable antennas. Specifically, such requirements are required to be considered on a priority basis in the wearable antennas, such as structural deformation, precision, and accuracy in fabrication methods and their size. Various researchers are active in this field and, accordingly, some significant progress has been achieved recently. This article attempts to critically review the wearable antennas especially in light of new materials and fabrication methods, and novel designs, such as miniaturized button antennas and miniaturized single and multi-band antennas, and their unique smart applications in WBAN. Finally, the conclusion has been drawn with respect to some future directions.

SELECTION OF CITATIONS
SEARCH DETAIL
...