Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Environ Monit Assess ; 195(9): 1126, 2023 Aug 31.
Article in English | MEDLINE | ID: mdl-37651046

ABSTRACT

Pollution from vehicular emissions is a major cause of poor air quality observed in many urban and semi-urban towns and cities. As such, this study was conducted to assess air quality and the spatiotemporal distribution of vehicular and traffic-related pollutants in several air sheds of Lagos megacity, the economic nerve centre of Nigeria. A setup of low-cost air quality sensors comprising five (5) units was deployed between November 2018 and February 2019 within traffic corridors in the heart of the city. Diurnal variation of pollutants indicated that carbon dioxide (CO2) peaked during the early hours of the day, total oxide (Ox = NO2+O3) peaked at mid-day while carbon monoxide (CO) had two distinct peaks which correspond to morning and evening rush hours. Nitrogen dioxide (NO2) concentration peaked during evening hours. Average concentrations are NO2 (97.1 ± 9.7) ppb, Ox (78.6 ± 27.2) ppb, CO2 (450.1 ± 31.2) ppm, and CO (2285.63 ± 743.7) ppb. Average concentrations of pollutants were above thresholds set by the World Health Organization (WHO) except for NO2 which was within the range permissible limits. The implication of this is that the atmosphere is polluted due to elevated concentrations of airborne pollutants, an indication which is of both health and environmental concern. The air quality index (AQI) indicates that the quality of ambient air varies from good to very unhealthy for Ox, and unhealthy to very unhealthy for CO, while AQI for PM2.5 and PM10 showed hazardous at all the sampling locations except at UNILAG where it is unhealthy for the sensitive group. For all of the sampling sites, conditional bivariate probability function (CBPF) plots show a significant agreement with the location of known pollution sources.


Subject(s)
Environmental Pollutants , Nigeria , Nitrogen Dioxide , Carbon Dioxide , Meteorology , Environmental Monitoring , Vehicle Emissions
2.
Heliyon ; 6(6): e04207, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32577574

ABSTRACT

The concentrations of fine and coarse fractions of airborne particulate matter (PM) and meteorological variables (wind speed, wind direction, temperature and relative humidity) were measured at six selected locations in Ile Ife, a prominent university town in Nigeria using a network of low-cost air quality (AQ) sensor units. The objective of the deployment was to collate baseline air quality data and assess the impact of prevailing meteorological conditions on PM concentrations in selected residential communities downwind of an iron smelting facility. The raw data obtained from OPC-N2 of the AQ sensor units was corrected using the RH correction factor developed based k-Kohler theory. This PM (corrected) fast time resolution data (20 s) from the AQ sensor units were used to create daily averages. The overall mean mass concentrations for PM2.5 and PM10 were 213.3, 44.1, 23.8, 27.7, 20.2 and 41.5 µg/m3 and; 439.9, 107.1, 55.0, 72.4, 45.5 and 112.0 µg/m3 for Fasina (Iron-Steel Smelting Factory, ISSF), Modomo, Eleweran, Fire Service, O.A.U. staff quarters and Obafemi Awolowo University Teaching and Research Farm (OAUTRF), respectively. PM concentration and wind speed showed a negative exponential distribution curve with the lowest exponential fit coefficient of determination (R2) values of 0.08 for PM2.5 and 0.03 for PM10 during nighttime periods at Eleweran and Fire service sites, respectively. The relationship between PM concentration and temperature gave a decay curve indicating that higher PM concentrations were observed at lower temperatures. The exponential distribution curve for the relationship between PM concentration and relative humidity (RH) showed that PM concentrations do not vary for RH < 80 % while stronger relationship was noticed with higher PM concentration for RH > 80 % for both day and nighttime. The performances of the MLR model were slightly poor and as such not too reliable for predicting the concentration but useful for improving predictive model accuracy when other variables contributing to the variability of PM is considered. The study concluded that the anthropogenic and industrial activities at the smelting factory contribute significantly to the elevated PM mass concentration measured at the study locations.

SELECTION OF CITATIONS
SEARCH DETAIL
...