Strahlenther Onkol ; 192(11): 815-819, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27380001

ABSTRACT

OBJECTIVE: The Gamma Knife Icon (Elekta AB, Stockholm, Sweden) allows frameless stereotactic treatment using a combination of cone beam computer tomography (CBCT), a thermoplastic mask system, and an infrared-based high-definition motion management (HDMM) camera system for patient tracking during treatment. We report on the first patient with meningioma at the left petrous bone treated with adaptive fractionated stereotactic radiotherapy (a-gkFSRT). METHODS: The first patient treated with Gamma Knife Icon at our institute received MR imaging for preplanning before treatment. For each treatment fraction, a daily CBCT was performed to verify the actual scull/tumor position. The system automatically adapted the planned shot positions to the daily position and recalculated the dose distribution (online adaptive planning). During treatment, the HDMM system recorded the intrafractional patient motion. Furthermore, the required times were recorded to define a clinical treatment slot. RESULTS: Total treatment time was around 20 min. Patient positioning needed 0.8 min, CBCT positioning plus acquisition 1.65 min, CT data processing and adaptive planning 2.66 min, and treatment 15.6 min. The differences for the five daily CBCTs compared to the reference are for rotation: -0.59 ± 0.49°/0.18 ± 0.20°/0.05 ± 0.36° and for translation: 0.94 ± 0.52 mm/-0.08 ± 0.08 mm/-1.13 ± 0.89 mm. Over all fractions, an intrafractional movement of 0.13 ± 0.04 mm was observed. CONCLUSION: The Gamma Knife Icon allows combining the accuracy of the stereotactic Gamma Knife system with the flexibility of fractionated treatment with the mask system and CBCT. Furthermore, the Icon system introduces a new online patient tracking system to the clinical routine. The interfractional accuracy of patient positioning was controlled with a thermoplastic mask and CBCT.


Subject(s)
Cone-Beam Computed Tomography/instrumentation , Meningeal Neoplasms/radiotherapy , Meningioma/radiotherapy , Radiosurgery/instrumentation , Radiotherapy Planning, Computer-Assisted/instrumentation , Radiotherapy, Image-Guided/instrumentation , Aged , Cone-Beam Computed Tomography/methods , Dose Fractionation, Radiation , Equipment Design , Equipment Failure Analysis , Female , Humans , Meningeal Neoplasms/diagnostic imaging , Meningioma/diagnostic imaging , Radiosurgery/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Systems Integration , Treatment Outcome
2.
Strahlenther Onkol ; 188(8): 653-9, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22740169

ABSTRACT

BACKGROUND AND PURPOSE: Conventional algorithms show uncertainties in dose calculation already for three-dimensional conformal radiotherapy (3D-CRT). Intensity-modulated radiotherapy (IMRT) might even increase these. We wanted to assess differences in dose distribution for pencil beam (PB), collapsed cone (CC), and Monte Carlo (MC) algorithm for both 3D-CRT and IMRT in patients with mediastinal Hodgkin lymphoma. PATIENTS AND METHODS: Based on 20 computed tomograph (CT) datasets of patients with mediastinal Hodgkin lymphoma, we created treatment plans according to the guidelines of the German Hodgkin Study Group (GHSG) with PB and CC algorithm for 3D-CRT and with PB and MC algorithm for IMRT. Doses were compared for planning target volume (PTV) and organs at risk. RESULTS: For 3D-CRT, PB overestimated PTV(95) and V(20) of the lung by 6.9% and 3.3% and underestimated V(10) of the lung by 5.8%, compared to the CC algorithm. For IMRT, PB overestimated PTV(95), V(20) of the lung, V(25) of the heart and V(10) of the female left/right breast by 8.1%, 25.8%, 14.0% and 43.6%/189.1%, and underestimated V(10) of the lung, V(4) of the heart and V(4) of the female left/right breast by 6.3%, 6.8% and 23.2%/15.6%, compared to MC. CONCLUSION: The PB algorithm underestimates low doses to the organs at risk and overestimates dose to PTV and high doses to the organs at risk. For 3D-CRT, a well-modeled PB algorithm is clinically acceptable; for IMRT planning, however, an advanced algorithm such as CC or MC should be used at least for part of the plan optimization.


Subject(s)
Algorithms , Hodgkin Disease/radiotherapy , Mediastinal Neoplasms/radiotherapy , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Radiotherapy, Intensity-Modulated/methods , Breast/radiation effects , Female , Guideline Adherence , Humans , Imaging, Three-Dimensional/methods , Male , Organs at Risk , Radiation Dosage , Tomography, X-Ray Computed/methods