J Acoust Soc Am ; 126(1): EL34-40, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19603851

ABSTRACT

Use of ultrasonically excited microbubbles within blood vessels has been proposed for a variety of clinical applications. In this paper, an axisymmetric coupled boundary element and finite element code and experiments have been used to investigate the effects of a surrounding tube on a bubble's response to acoustic excitation. A balloon model allowed measurement of spherical gas bubble response. Resonance frequencies match one-dimensional cylindrical model predictions for a bubble well within a rigid tube but deviate for a bubble near the tube end. Simulations also predict bubble translation along the tube axis and aspherical oscillations at higher amplitudes.


Subject(s)
Acoustics , Gases , Microbubbles , Models, Theoretical , Blood Vessels/physiology , Computer Simulation , Motion , Vibration