Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
1.
Sensors (Basel) ; 24(13)2024 Jun 27.
Article in English | MEDLINE | ID: mdl-39000951

ABSTRACT

Hand-intensive work is strongly associated with work-related musculoskeletal disorders (WMSDs) of the hand/wrist and other upper body regions across diverse occupations, including office work, manufacturing, services, and healthcare. Addressing the prevalence of WMSDs requires reliable and practical exposure measurements. Traditional methods like electrogoniometry and optical motion capture, while reliable, are expensive and impractical for field use. In contrast, small inertial measurement units (IMUs) may provide a cost-effective, time-efficient, and user-friendly alternative for measuring hand/wrist posture during real work. This study compared six orientation algorithms for estimating wrist angles with an electrogoniometer, the current gold standard in field settings. Six participants performed five simulated hand-intensive work tasks (involving considerable wrist velocity and/or hand force) and one standardised hand movement. Three multiplicative Kalman filter algorithms with different smoothers and constraints showed the highest agreement with the goniometer. These algorithms exhibited median correlation coefficients of 0.75-0.78 for flexion/extension and 0.64 for radial/ulnar deviation across the six subjects and five tasks. They also ranked in the top three for the lowest mean absolute differences from the goniometer at the 10th, 50th, and 90th percentiles of wrist flexion/extension (9.3°, 2.9°, and 7.4°, respectively). Although the results of this study are not fully acceptable for practical field use, especially for some work tasks, they indicate that IMU-based wrist angle estimation may be useful in occupational risk assessments after further improvements.


Subject(s)
Algorithms , Wrist , Humans , Wrist/physiology , Male , Adult , Female , Range of Motion, Articular/physiology , Biomechanical Phenomena , Movement/physiology , Hand/physiology , Wrist Joint/physiology
2.
Biomedicines ; 12(6)2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38927569

ABSTRACT

Previous studies have suggested an association between Proton Pump Inhibitors (PPIs) and the progression of chronic kidney disease (CKD). This study aims to assess the association between PPI use and CKD progression by analysing estimated glomerular filtration rate (eGFR) trajectories using a process mining approach. We conducted a retrospective cohort study from 1 January 2006 to 31 December 2011, utilising data from the Stockholm Creatinine Measurements (SCREAM). New users of PPIs and H2 blockers (H2Bs) with CKD (eGFR < 60) were identified using a new-user and active-comparator design. Process mining discovery is a technique that discovers patterns and sequences in events over time, making it suitable for studying longitudinal eGFR trajectories. We used this technique to construct eGFR trajectory models for both PPI and H2B users. Our analysis indicated that PPI users exhibited more complex and rapidly declining eGFR trajectories compared to H2B users, with a 75% increased risk (adjusted hazard ratio [HR] 1.75, 95% confidence interval [CI] 1.49 to 2.06) of transitioning from moderate eGFR stage (G3) to more severe stages (G4 or G5). These findings suggest that PPI use is associated with an increased risk of CKD progression, demonstrating the utility of process mining for longitudinal analysis in epidemiology, leading to an improved understanding of disease progression.

3.
J Matern Fetal Neonatal Med ; 37(1): 2345855, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38679588

ABSTRACT

INTRODUCTION: Intraamniotic infection (IAI) and subsequent early-onset neonatal sepsis (EONS) are among the main complications associated with preterm prelabor rupture of membranes (PPROM). Currently used diagnostic tools have been shown to have poor diagnostic performance for IAI. This study aimed to investigate whether the exposure to IAI before delivery is associated with short-term variation of the fetal heart rate in pregnancies with PPROM. METHODS: Observational cohort study of 678 pregnancies with PPROM, delivering between 24 + 0 and 33 + 6 gestational weeks from 2012 to 2019 in five labor units in Stockholm County, Sweden. Electronic medical records were examined to obtain background and exposure data. For the exposure IAI, we used the later diagnosis of EONS in the offspring as a proxy. EONS is strongly associated to IAI and was considered a better proxy for IAI than the histological diagnosis of acute chorioamnionitis, since acute chorioamnionitis can be observed in the absence of both positive microbiology and biochemical markers for inflammation. Cardiotocography traces were analyzed by a computerized algorithm for short-term variation of the fetal heart rate, which was the main outcome measure. RESULTS: Twenty-seven pregnancies were categorized as having an IAI, based on the proxy diagnosis of EONS after birth. Fetuses exposed to IAI had significantly lower short-term variation values in the last cardiotocography trace before birth than fetuses who were not exposed (5.25 vs 6.62 ms; unadjusted difference: -1.37, p = 0.009). After adjustment for smoking and diabetes, this difference remained significant. IAI with a later positive blood culture in the neonate (n = 12) showed an even larger absolute difference in STV (-1.65; p = 0.034), with a relative decrease of 23.5%. CONCLUSION: In pregnancies with PPROM, fetuses exposed to IAI with EONS as a proxy have lower short-term variation of the fetal heart rate than fetuses who are not exposed. Short-term variation might be useful as adjunct surveillance in pregnancies with PPROM.


Subject(s)
Cardiotocography , Fetal Membranes, Premature Rupture , Heart Rate, Fetal , Humans , Female , Pregnancy , Heart Rate, Fetal/physiology , Fetal Membranes, Premature Rupture/diagnosis , Adult , Infant, Newborn , Chorioamnionitis/diagnosis , Cohort Studies , Sweden/epidemiology , Neonatal Sepsis/diagnosis , Pregnancy Complications, Infectious/diagnosis , Gestational Age
4.
Health Informatics J ; 29(4): 14604582231213846, 2023.
Article in English | MEDLINE | ID: mdl-38063181

ABSTRACT

In modern hospitals, monitoring patients' vital signs and other biomedical signals is standard practice. With the advent of data-driven healthcare, Internet of medical things, wearable technologies, and machine learning, we expect this to accelerate and to be used in new and promising ways, including early warning systems and precision diagnostics. Hence, we see an ever-increasing need for retrieving, storing, and managing the large amount of biomedical signal data generated. The popularity of standards, such as HL7 FHIR for interoperability and data transfer, have also resulted in their use as a data storage model, which is inefficient. This article raises concern about the inefficiency of using FHIR for storage of biomedical signals and instead highlights the possibility of a sustainable storage based on data compression. Most reported efforts have focused on ECG signals; however, many other typical biomedical signals are understudied. In this article, we are considering arterial blood pressure, photoplethysmography, and respiration. We focus on simple lossless compression with low implementation complexity, low compression delay, and good compression ratios suitable for wide adoption. Our results show that it is easy to obtain a compression ratio of 2.7:1 for arterial blood pressure, 2.9:1 for photoplethysmography, and 4.1:1 for respiration.


Subject(s)
Data Compression , Humans , Electronic Health Records , Delivery of Health Care , Hospitals , Internet
5.
Sensors (Basel) ; 23(22)2023 Nov 16.
Article in English | MEDLINE | ID: mdl-38005593

ABSTRACT

The development of smart wearable solutions for monitoring daily life health status is increasingly popular, with chest straps and wristbands being predominant. This study introduces a novel sensorized T-shirt design with textile electrodes connected via a knitting technique to a Movesense device. We aimed to investigate the impact of stationary and movement actions on electrocardiography (ECG) and heart rate (HR) measurements using our sensorized T-shirt. Various activities of daily living (ADLs), including sitting, standing, walking, and mopping, were evaluated by comparing our T-shirt with a commercial chest strap. Our findings demonstrate measurement equivalence across ADLs, regardless of the sensing approach. By comparing ECG and HR measurements, we gained valuable insights into the influence of physical activity on sensorized T-shirt development for monitoring. Notably, the ECG signals exhibited remarkable similarity between our sensorized T-shirt and the chest strap, with closely aligned HR distributions during both stationary and movement actions. The average mean absolute percentage error was below 3%, affirming the agreement between the two solutions. These findings underscore the robustness and accuracy of our sensorized T-shirt in monitoring ECG and HR during diverse ADLs, emphasizing the significance of considering physical activity in cardiovascular monitoring research and the development of personal health applications.


Subject(s)
Activities of Daily Living , Textiles , Humans , Heart Rate/physiology , Electrocardiography , Monitoring, Physiologic/methods
6.
Artif Intell Med ; 144: 102645, 2023 10.
Article in English | MEDLINE | ID: mdl-37783545

ABSTRACT

The widespread use of information technology in healthcare leads to extensive data collection, which can be utilised to enhance patient care and manage chronic illnesses. Our objective is to summarise previous studies that have used data mining or process mining methods in the context of chronic diseases in order to identify research trends and future opportunities. The review covers articles that pertain to the application of data mining or process mining methods on chronic diseases that were published between 2000 and 2022. Articles were sourced from PubMed, Web of Science, EMBASE, and Google Scholar based on predetermined inclusion and exclusion criteria. A total of 71 articles met the inclusion criteria and were included in the review. Based on the literature review results, we detected a growing trend in the application of data mining methods in diabetes research. Additionally, a distinct increase in the use of process mining methods to model clinical pathways in cancer research was observed. Frequently, this takes the form of a collaborative integration of process mining, data mining, and traditional statistical methods. In light of this collaborative approach, the meticulous selection of statistical methods based on their underlying assumptions is essential when integrating these traditional methods with process mining and data mining methods. Another notable challenge is the lack of standardised guidelines for reporting process mining studies in the medical field. Furthermore, there is a pressing need to enhance the clinical interpretation of data mining and process mining results.


Subject(s)
Data Mining , Delivery of Health Care , Humans , Data Mining/methods , Chronic Disease
7.
Sensors (Basel) ; 23(9)2023 Apr 25.
Article in English | MEDLINE | ID: mdl-37177463

ABSTRACT

Work-related musculoskeletal disorders (WMSDs) are a major contributor to disability worldwide and substantial societal costs. The use of wearable motion capture instruments has a role in preventing WMSDs by contributing to improvements in exposure and risk assessment and potentially improved effectiveness in work technique training. Given the versatile potential for wearables, this article aims to provide an overview of their application related to the prevention of WMSDs of the trunk and upper limbs and discusses challenges for the technology to support prevention measures and future opportunities, including future research needs. The relevant literature was identified from a screening of recent systematic literature reviews and overviews, and more recent studies were identified by a literature search using the Web of Science platform. Wearable technology enables continuous measurements of multiple body segments of superior accuracy and precision compared to observational tools. The technology also enables real-time visualization of exposures, automatic analyses, and real-time feedback to the user. While miniaturization and improved usability and wearability can expand the use also to more occupational settings and increase use among occupational safety and health practitioners, several fundamental challenges remain to be resolved. The future opportunities of increased usage of wearable motion capture devices for the prevention of work-related musculoskeletal disorders may require more international collaborations for creating common standards for measurements, analyses, and exposure metrics, which can be related to epidemiologically based risk categories for work-related musculoskeletal disorders.


Subject(s)
Musculoskeletal Diseases , Occupational Diseases , Occupational Health , Wearable Electronic Devices , Humans , Motion Capture , Ergonomics/methods , Musculoskeletal Diseases/prevention & control , Musculoskeletal Diseases/diagnosis , Occupational Diseases/prevention & control , Occupational Diseases/diagnosis
8.
Sensors (Basel) ; 23(8)2023 Apr 13.
Article in English | MEDLINE | ID: mdl-37112309

ABSTRACT

Smart workwear systems with embedded inertial measurement unit sensors are developed for convenient ergonomic risk assessment of occupational activities. However, its measurement accuracy can be affected by potential cloth artifacts, which have not been previously assessed. Therefore, it is crucial to evaluate the accuracy of sensors placed in the workwear systems for research and practice purposes. This study aimed to compare in-cloth and on-skin sensors for assessing upper arms and trunk postures and movements, with the on-skin sensors as the reference. Five simulated work tasks were performed by twelve subjects (seven women and five men). Results showed that the mean (±SD) absolute cloth-skin sensor differences of the median dominant arm elevation angle ranged between 1.2° (±1.4) and 4.1° (±3.5). For the median trunk flexion angle, the mean absolute cloth-skin sensor differences ranged between 2.7° (±1.7) and 3.7° (±3.9). Larger errors were observed for the 90th and 95th percentiles of inclination angles and inclination velocities. The performance depended on the tasks and was affected by individual factors, such as the fit of the clothes. Potential error compensation algorithms need to be investigated in future work. In conclusion, in-cloth sensors showed acceptable accuracy for measuring upper arm and trunk postures and movements on a group level. Considering the balance of accuracy, comfort, and usability, such a system can potentially be a practical tool for ergonomic assessment for researchers and practitioners.


Subject(s)
Arm , Movement , Male , Humans , Female , Biomechanical Phenomena , Posture , Upper Extremity
9.
Int J Occup Saf Ergon ; 28(3): 1840-1848, 2022 Sep.
Article in English | MEDLINE | ID: mdl-34193025

ABSTRACT

Inclinometry and video analyses can provide objective measures of physical workloads. The study aim was to measure and observe arm, back and head postures and movements among forklift truck operators (FLTOs) during a working day, analyzing differences between types of forklift trucks and to assess reported workload and health. Twenty-five male FLTOs in a high-level warehouse were randomly included. The data collected comprised technical measurements, video analyses of postures and movements, and a questionnaire measuring health, pain and workload. On average, the FLTOs rotated their head more than 45°, in total, 232 times/h. Video analysis revealed that FLTOs periodically drive the forklift truck sideways with the head rotated in the direction of travel, and in periods look upwards, in which the head is highly rotated and extended. Inclinometry and observations during the working day has the potential to be a valuable part of risk assessment promoting occupational safety and health.


Subject(s)
Occupational Diseases , Occupational Health , Humans , Male , Motor Vehicles , Movement , Posture , Workload
10.
Appl Ergon ; 89: 103188, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32854822

ABSTRACT

Vibrotactile feedback training may be one possible method for interventions that target at learning better work techniques and improving postures in manual handling. This study aimed to evaluate the short term effect of real-time vibrotactile feedback on postural exposure using a smart workwear system for work postures intervention in simulated industrial order picking. Fifteen workers at an industrial manufacturing plant performed order-picking tasks, in which the vibrotactile feedback was used for postural training at work. The system recorded the trunk and upper arm postures. Questionnaires and semi-structured interviews were conducted about the users' experience of the system. The results showed reduced time in trunk inclination ≥20°, ≥30° and ≥45° and dominant upper arm elevation ≥30° and ≥45° when the workers received feedback, and for trunk inclination ≥20°, ≥30° and ≥45° and dominant upper arm elevation ≥30°, after feedback withdrawal. The workers perceived the system as useable, comfortable, and supportive for learning. The system has the potential of contributing to improved postures in order picking through an automated short-term training program.


Subject(s)
Ergonomics/instrumentation , Feedback, Sensory , Occupational Exposure/analysis , Wearable Electronic Devices , Work/physiology , Adult , Arm/physiology , Biomechanical Phenomena , Ergonomics/methods , Female , Humans , Male , Manufacturing Industry , Musculoskeletal Diseases/prevention & control , Occupational Diseases/prevention & control , Postural Balance/physiology , Posture/physiology , Task Performance and Analysis , Torso/physiology , Touch , Vibration , Weight-Bearing/physiology
11.
Sensors (Basel) ; 19(20)2019 Oct 12.
Article in English | MEDLINE | ID: mdl-31614859

ABSTRACT

The interconnection between hard electronics and soft textiles remains a noteworthy challenge in regard to the mass production of textile-electronic integrated products such as sensorized garments. The current solutions for this challenge usually have problems with size, flexibility, cost, or complexity of assembly. In this paper, we present a solution with a stretchable and conductive carbon nanotube (CNT)-based paste for screen printing on a textile substrate to produce interconnectors between electronic instrumentation and a sensorized garment. The prototype connectors were evaluated via electrocardiogram (ECG) recordings using a sensorized textile with integrated textile electrodes. The ECG recordings obtained using the connectors were evaluated for signal quality and heart rate detection performance in comparison to ECG recordings obtained with standard pre-gelled Ag/AgCl electrodes and direct cable connection to the ECG amplifier. The results suggest that the ECG recordings obtained with the CNT paste connector are of equivalent quality to those recorded using a silver paste connector or a direct cable and are suitable for the purpose of heart rate detection.


Subject(s)
Electrocardiography , Textiles , Wearable Electronic Devices , Electric Impedance , Humans , Nanotubes, Carbon/chemistry , Regression Analysis , Surface Properties
12.
Mol Med ; 25(1): 39, 2019 08 15.
Article in English | MEDLINE | ID: mdl-31416428

ABSTRACT

BACKGROUND: Renal denervation (RDN) reduces sympathetic tone and may alter the sympathetic-parasympathetic balance. The autonomic nervous system is partly a regulator of innate immunity via the cholinergic anti-inflammatory pathway (CAP) which inhibits inflammation via the vagus nerve. Placental Growth Factor (PlGF) influences a neuro-immunological pathway in the spleen which may contribute to hypertension. The aim of this study was to investigate if modulation of renal sympathetic nerve activity affects CAP in terms of cytokine release as well as levels of PlGF. METHODS: Ten patients treated with RDN (Medtronic Inc), were analyzed for TNF, IL-1b and IL-10 and Lipopolysaccharide (LPS)-stimulated cytokine release before RDN, 1 day after and at 3- and 6-months follow-up. Four patients who underwent elective coronary angiography served as disease controls (DC). RESULTS: Baseline TNF was significantly lower 1 day after RDN (p = 0.03). LPS-stimulated (0, 10 and 100 ng/mL) TNF and IL-1b were significantly lower 1 day after RDN (TNF p = 0.0009, p = 0.0009 and p = 0.001, IL-1b; p = 0.0001, p = 0.002 and p = 0.005). IL-10 was significantly higher one day after RDN (p = ns, p = 0.02 and p = 0.01). These differences however declined during follow up. A more marked TNF reduction was achieved with a cholinergic analogue, GTS-21, in LPS-stimulated whole blood as compared with samples without GTS-21. Cytokine levels in controls did not differ before and 1 day after coronary angiography. PlGF was significantly higher in RDN patients and DC compared with healthy controls but did not change during follow-up. CONCLUSION: RDN has an immediate effect on TNF in vivo and cytokine release ex vivo but seems to wane over time suggesting that current RDN techniques may not have long-lasting immunomodulatory effect. Repeated and extended stimulation of CAP in resistant hypertension by targeting neural circuits may be a potential therapeutic strategy for treatment of both hypertension and inflammation.


Subject(s)
Denervation/methods , Hypertension/surgery , Kidney/innervation , Neuroimmunomodulation/physiology , Aged , Blood Pressure/physiology , Cytokines/analysis , Cytokines/metabolism , Female , Humans , Inflammation/metabolism , Male , Middle Aged
13.
Sensors (Basel) ; 19(5)2019 Mar 11.
Article in English | MEDLINE | ID: mdl-30862019

ABSTRACT

Preventive healthcare has attracted much attention recently. Improving people's lifestyles and promoting a healthy diet and wellbeing are important, but the importance of work-related diseases should not be undermined. Musculoskeletal disorders (MSDs) are among the most common work-related health problems. Ergonomists already assess MSD risk factors and suggest changes in workplaces. However, existing methods are mainly based on visual observations, which have a relatively low reliability and cover only part of the workday. These suggestions concern the overall workplace and the organization of work, but rarely includes individuals' work techniques. In this work, we propose a precise and pervasive ergonomic platform for continuous risk assessment. The system collects data from wearable sensors, which are synchronized and processed by a mobile computing layer, from which exposure statistics and risk assessments may be drawn, and finally, are stored at the server layer for further analyses at both individual and group levels. The platform also enables continuous feedback to the worker to support behavioral changes. The deployed cloud platform in Amazon Web Services instances showed sufficient system flexibility to affordably fulfill requirements of small to medium enterprises, while it is expandable for larger corporations. The system usability scale of 76.6 indicates an acceptable grade of usability.


Subject(s)
Biosensing Techniques , Musculoskeletal Diseases/physiopathology , Wearable Electronic Devices , Ergonomics/methods , Humans , Occupational Diseases/physiopathology
14.
Sensors (Basel) ; 18(9)2018 Sep 14.
Article in English | MEDLINE | ID: mdl-30223429

ABSTRACT

This paper presents a new method that integrates heart rate, respiration, and motion information obtained from a wearable sensor system to estimate energy expenditure. The system measures electrocardiography, impedance pneumography, and acceleration from upper and lower limbs. A multilayer perceptron neural network model was developed, evaluated, and compared to two existing methods, with data from 11 subjects (mean age, 27 years, range, 21⁻65 years) who performed a 3-h protocol including submaximal tests, simulated work tasks, and periods of rest. Oxygen uptake was measured with an indirect calorimeter as a reference, with a time resolution of 15 s. When compared to the reference, the new model showed a lower mean absolute error (MAE = 1.65 mL/kg/min, R² = 0.92) than the two existing methods, i.e., the flex-HR method (MAE = 2.83 mL/kg/min, R² = 0.75), which uses only heart rate, and arm-leg HR+M method (MAE = 2.12 mL/kg/min, R² = 0.86), which uses heart rate and motion information. As indicated, this new model may, in combination with a wearable system, be useful in occupational and general health applications.


Subject(s)
Energy Metabolism , Heart Rate , Movement , Respiration , Wearable Electronic Devices , Adult , Aged , Electrocardiography , Female , Humans , Male , Middle Aged , Oxygen/metabolism , Young Adult
15.
IEEE J Biomed Health Inform ; 22(6): 1883-1894, 2018 11.
Article in English | MEDLINE | ID: mdl-29990025

ABSTRACT

Impedance Cardiography (ICG) is a non-invasive method for monitoring cardiac dynamics using Electrical Bioimpedance (EBI) measurements. Since its appearance more than 40 years ago, ICG has been used for assessing hemodynamic parameters. This paper present a measurement system based on two System on Chip (SoC) solutions and Raspberry PI, implementing both a full 3-lead ECG recorder and an impedance cardiographer, for educational and research development purposes. Raspberry PI is a platform supporting Do-It-Yourself project and education applications across the world. The development is part of Biosignal PI, an open hardware platform focusing in quick prototyping of physiological measurement instrumentation. The SoC used for sensing cardiac biopotential is the ADAS1000, and for the EBI measurement is the AD5933. The recording were wirelessly transmitted through Bluetooth to a PC, where the waveforms were displayed, and hemodynamic parameters such as heart rate, stroke volume, ejection time and cardiac output were extracted from the ICG and ECG recordings. These results show how Raspberry PI can be used for quick prototyping using relatively widely available and affordable components, for supporting developers in research and engineering education. The design and development documents, will be available on www.BiosignalPI.com, for open access under a Non Commercial-Share A like 4.0 International License.


Subject(s)
Cardiography, Impedance/instrumentation , Electrocardiography/instrumentation , Signal Processing, Computer-Assisted/instrumentation , Adult , Biomedical Technology , Equipment Design , Female , Humans , Male , Young Adult
16.
Microvasc Res ; 120: 100-110, 2018 11.
Article in English | MEDLINE | ID: mdl-29958863

ABSTRACT

BACKGROUND: Nailfold capillaroscopy (NC) is a diagnostic imaging technique that is used to assess the blood capillary network in the nailfold area. NC is routinely used for patients with microcirculation problems, such as systemic sclerosis and other connective tissue diseases. Experts commonly use subjective evaluation as a reference point in images of nailfold video capillaroscopy, so it is important to reduce the inherent ambiguities in human judgment and diagnosis. Image quality is an important factor that affects measurement error and assessment time of NC images. OBJECTIVE: In this study, a new image enhancement technique was introduced and evaluated subjectively. METHODS: In total, 475 nailfold video capillaroscopy images from 18 healthy subjects and 41 systemic lupus erythematosus patients were used. The images were randomly divided into two sets, one each with 275 and 200. Eight independent observers who were familiar with the capillaroscopy technique participated in this study. The set of 275 images was evaluated by three observers with the forced-choice pairwise comparison method. Elliptic broken line (EBL) was used to count the number of capillaries. The intra- and inter-observer reliability of the original and enhanced images was evaluated on 200 images by five observers. RESULT: Except for eight images, all observers preferred the enhanced images in the visual quality comparison method. The intra-class correlation coefficient (ICC) of intra- and inter-observer reliability increased from 0.76-0.84 to 0.82-0.89, respectively, when using the enhancement method. CONCLUSION: By improving the image quality, more capillary details will be visible, and an observer can document more details that may not be visible in the original image and can do so more efficiently.


Subject(s)
Capillaries/diagnostic imaging , Image Enhancement/methods , Lupus Erythematosus, Systemic/diagnostic imaging , Microcirculation , Microscopic Angioscopy/methods , Nails/blood supply , Adult , Aged , Capillaries/physiopathology , Case-Control Studies , Female , Humans , Lupus Erythematosus, Systemic/physiopathology , Male , Middle Aged , Observer Variation , Predictive Value of Tests , Regional Blood Flow , Reproducibility of Results , Young Adult
17.
Acta Obstet Gynecol Scand ; 97(9): 1137-1147, 2018 Sep.
Article in English | MEDLINE | ID: mdl-29768660

ABSTRACT

INTRODUCTION: Reliability in visual cardiotocography interpretation is unsatisfying, which has led to the development of computerized cardiotocography. Computerized analysis is well established for antenatal fetal surveillance but has yet not performed sufficiently during labor. We aimed to investigate the capacity of a new computerized algorithm compared with visual assessment in identifying intrapartum fetal heart rate baseline and decelerations. MATERIAL AND METHODS: In all, 312 intrapartum cardiotocography tracings with variable decelerations were analyzed by the computerized algorithm and visually examined by two observers, blinded to each other and the computer analysis. The width, depth and area of each deceleration was measured. Four cases (>100 variable decelerations) were subjected to in-depth detailed analysis. The outcome measures were bias in seconds (width), beats per minute (depth), and beats (area) between computer and observers using Bland-Altman analysis. Interobserver reliability was determined by calculating intraclass correlation and Spearman rank analysis. RESULTS: The analysis (312 cases) showed excellent intraclass correlation (0.89-0.95) and very strong Spearman correlation (0.82-0.91). The detailed analysis of >100 decelerations in four cases revealed low bias between the computer and the two observers; width 1.4 and 1.4 seconds, depth 5.1 and 0.7 beats per minute, and area 0.1 and -1.7 beats. This was comparable to the bias between the two observers: 0.3 seconds (width), 4.4 beats per minute (depth) and 1.7 beats (area). The intraclass correlation was excellent (0.90-.98). CONCLUSION: A novel computerized algorithm for intrapartum cardiotocography analysis is as accurate as gold standard visual assessment, with high correlation and low bias.


Subject(s)
Algorithms , Cardiotocography/methods , Heart Rate, Fetal/physiology , Deceleration , Female , Humans , Pregnancy , Signal Processing, Computer-Assisted
18.
Microvasc Res ; 113: 1-8, 2017 09.
Article in English | MEDLINE | ID: mdl-28414021

ABSTRACT

Nailfold capillaroscopy is a practical method for identifying and obtaining morphological changes in capillaries which might reveal relevant information about diseases and health. Capillaroscopy is harmless, and seems simple and repeatable. However, there is lack of established guidelines and instructions for acquisition as well as the interpretation of the obtained images; which might lead to various ambiguities. In addition, assessment and interpretation of the acquired images are very subjective. In an attempt to overcome some of these problems, in this study a new modified technique for assessment of nailfold capillary density is introduced. The new method is named elliptic broken line (EBL) which is an extension of the two previously known methods by defining clear criteria for finding the apex of capillaries in different scenarios by using a fitted elliptic. A graphical user interface (GUI) is developed for pre-processing, manual assessment of capillary apexes and automatic correction of selected apexes based on 90° rule. Intra- and inter-observer reliability of EBL and corrected EBL is evaluated in this study. Four independent observers familiar with capillaroscopy performed the assessment for 200 nailfold videocapillaroscopy images, form healthy subject and systemic lupus erythematosus patients, in two different sessions. The results show elevation from moderate (ICC=0.691) and good (ICC=0.753) agreements to good (ICC=0.750) and good (ICC=0.801) for intra- and inter-observer reliability after automatic correction of EBL. This clearly shows the potential of this method to improve the reliability and repeatability of assessment which motivates us for further development of automatic tool for EBL method.


Subject(s)
Capillaries/pathology , Lupus Erythematosus, Systemic/pathology , Microscopic Angioscopy/methods , Nails/blood supply , Adult , Case-Control Studies , Female , Humans , Male , Middle Aged , Observer Variation , Predictive Value of Tests , Reproducibility of Results , Young Adult
19.
Clin Kidney J ; 8(5): 599-605, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26413288

ABSTRACT

BACKGROUND: The cholinergic anti-inflammatory pathway (CAP) modulates inflammatory responses through the vagus nerve and the α-7-nicotinic acetylcholine receptor (α7nAChR) on macrophages and immune cells. Sympathetic/parasympathetic imbalance and chronic inflammation are both linked to poor outcome in dialysis patients. The aim of this study was to investigate CAP activity in these patients. METHODS: Twenty dialysis patients, 12 hemodialysis (HD) and 8 peritoneal dialysis (PD) patients (12 male, 8 female; age range 47-83 years) and 8 controls (5 male, 3 female; age range 31-52 years) were analyzed for C-reactive protein (CRP), tumor necrosis factor (TNF), interleukin-1b (IL-1b), IL-6 and IL-10 at baseline. The cytokines were then assessed after whole blood stimulation ex vivo with lipopolysaccharide (LPS) (10 and 100 ng/mL) and again in the presence of 45 and 90 µmol/L GTS-21, a cholinergic α7nAChR agonist. RESULTS: CRP, TNF, IL-1 and IL-6 were significantly higher, whereas IL-10 was significantly lower at baseline in patients compared with controls. After LPS stimulation, TNF increased significantly more in patients than in controls but decreased to similar levels in both groups after addition of GTS-21. IL-6 attenuation was comparable with TNF and the IL-1b pattern was similar but remained significantly higher in patients. Interestingly, IL-10 increased after GTS-21 in a dose-dependent manner, but only in patients. Results in HD and PD patients did not differ. CONCLUSIONS: The response of immune cells after LPS exposure and cholinergic stimulation suggests a functional CAP in dialysis patients. It may thus be possible to target the α7nAChR control of cytokine release as an anti-inflammatory strategy and thereby improve outcome in these patients.

20.
Biomed Res Int ; 2015: 656323, 2015.
Article in English | MEDLINE | ID: mdl-26137489

ABSTRACT

For several decades electrical bioimpedance (EBI) has been used to assess body fluid distribution and body composition. Despite the development of several different approaches for assessing total body water (TBW), it remains uncertain whether bioimpedance spectroscopic (BIS) approaches are more accurate than single frequency regression equations. The main objective of this study was to answer this question by calculating the expected accuracy of a single measurement for different EBI methods. The results of this study showed that all methods produced similarly high correlation and concordance coefficients, indicating good accuracy as a method. Even the limits of agreement produced from the Bland-Altman analysis indicated that the performance of single frequency, Sun's prediction equations, at population level was close to the performance of both BIS methods; however, when comparing the Mean Absolute Percentage Error value between the single frequency prediction equations and the BIS methods, a significant difference was obtained, indicating slightly better accuracy for the BIS methods. Despite the higher accuracy of BIS methods over 50 kHz prediction equations at both population and individual level, the magnitude of the improvement was small. Such slight improvement in accuracy of BIS methods is suggested insufficient to warrant their clinical use where the most accurate predictions of TBW are required, for example, when assessing over-fluidic status on dialysis. To reach expected errors below 4-5%, novel and individualized approaches must be developed to improve the accuracy of bioimpedance-based methods for the advent of innovative personalized health monitoring applications.


Subject(s)
Body Composition/physiology , Body Water/physiology , Dielectric Spectroscopy , Renal Dialysis , Aged , Body Fluids/physiology , Female , Humans , Male , Middle Aged , Precision Medicine
SELECTION OF CITATIONS
SEARCH DETAIL
...