Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
1.
J Cardiovasc Dev Dis ; 11(2)2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38392271

ABSTRACT

Background: Adding electroanatomical left atrial (LA) voltage mapping to cryoballoon ablation (CBA) improves validation of acute pulmonary vein isolation (PVI). Aims: To determine whether the addition of mapping can improve outcome and PVI durability. Methods: One-year outcome and PV reconnection (PVR) rate at first repeat ablation were studied in 400 AF patients in a propensity-matched analysis (age, AF type, CHA2DS2-VASc score) between Achieve catheter-guided CBA with additional EnSite LA voltage maps performed pre- and post-CBA (mapping group; N = 200) and CT- and Achieve catheter-guided CBA (control group; N = 200). Clinical success was defined as freedom of documented AF or atrial tachycardia (AT) > 30 s. PV reconnection patterns were characterized in repeat ablations. Results: At 1 year, 77 (19.25%) patients had recurrence of AF/AT, significantly lower than in the mapping group: 21 (10.5%) vs. 56 (28%), p < 0.001. Procedure time was shorter (72.2 ± 25.4 vs. 78.2 ± 29.3 min, p = 0.034) and radiation exposure lower (4465.0 ± 3454.6 Gy.cm2 vs. 5940.5 ± 4290.5 Gy.cm2, p = 0.037). Use of mapping was protective towards AF/AT recurrence (HR = 0.348; 95% CI 0.210-0.579; p < 0.001), independent of persistent AF type (HR = 1.723; 95% CI 1.034-2.872; p = 0.037), and LA diameter (HR = 1.055; 95% CI 1.015-1.096; p = 0.006). At repeat ablation (N = 90), persistent complete PVI was seen in 14/20 (70.0%) versus 23/70 (32.9%) in the mapping and conventional group, respectively (p = 0.03). Reconnection rate of the right inferior PV was lower with mapping (10.0% vs. 34,3%, p = 0.035). Conclusions: Adding electroanatomical LA voltage mapping to CBA improves 1-year clinical outcome and lowers both procedure time and radiation exposure. At repeat, use of mapping increases complete persistent PVI mainly by improving PVI durability of the RIPV.

2.
J Interv Card Electrophysiol ; 65(2): 559-571, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35869379

ABSTRACT

BACKGROUND: Cryoballoon technology (CB-A) has become a cornerstone of atrial fibrillation (AF) ablation in terms of safety and efficacy. Data regarding CB-A in octogenarians are still scarce and limited to single center experiences. The present study sought to analyze the performances of index CB-A in patients older than 80 years-old referring to 3 high-volume European centers. METHODS AND RESULTS: We retrospectively enrolled 95 patients with a median age of 81 [80, 83] years. 62 (65.3%) patients presented with paroxysmal AF and 33 (33.7%) with persistent AF. Mean procedure and fluoroscopy times were 73.8 ± 25.2 and 15.3 ± 7.5 min, respectively. At 12 months and 24 months of follow-up, the overall freedom from AF was 81.1% and 66.6%, respectively. When divided for AF type, freedom from AF was higher in patients with paroxysmal AF (p = 0.007). Cryoballoon ablation was able to significantly improve AF-related symptoms as proven by the significant decrease in EHRA score during the follow-up (p < 0.0001). Phrenic nerve palsy occurred in 8 (8.5%) patients and always resolved during the procedure without affecting procedural outcome. Two major complications occurred (2.1%); one patient experienced pneumonia, successfully treated with antibiotics and non-invasive mechanical ventilation, the latter one experienced acute kidney failure secondary to urosepsis successfully treated by renal replacement therapy. CONCLUSIONS: The present study showed that CB-A is a feasible and effective procedure among octogenarians with a low complication rate. Contemporarily, CB-A can help to alleviate arrhythmia-related symptoms also among this group of subjects.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Aged, 80 and over , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Pulmonary Veins/surgery , Cryosurgery/methods , Retrospective Studies , Octogenarians , Treatment Outcome , Recurrence
3.
Heart Rhythm O2 ; 3(6Part A): 656-664, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36589911

ABSTRACT

Background: Atrial fibrillation (AF) ablation strategy is associated with a non-negligible risk of complications and often requires repeat procedures (AF ablation track), implying repetitive exposure to procedural risk. Objective: The purpose of this study was to develop and validate a model to estimate individualized cumulative risk of complications in patients undergoing the AF ablation track (Atrial Fibrillation TRAck Complication risK [AF-TRACK] calculator). Methods: The model was derived from a multicenter cohort including 3762 AF ablation procedures in 2943 patients. A first regression model was fitted to predict the propensity for repeat ablation. The AF-TRACK calculator computed the risk of AF ablation track complications, considering the propensity for repeat ablation. Internal (cross-validation) and external (independent cohort) validation were assessed for discrimination capacity (area under the curve [AUC]) and goodness of fit (Hosmer-Lemeshow [HL] test). Results: Complications (N = 111) occurred in 3.7% of patients (2.9% of procedures). Predictors included female sex, heart failure, sleep apnea syndrome, and repeat procedures. The model showed fair discrimination capacity to predict complications (AUC 0.61 [0.55-0.67]) and likelihood of repeat procedure (AUC 0.62 [0.60-0.64]), with good calibration (HL χ2 12.5; P = .13). The model maintained adequate discrimination capacity (AUC 0.67 [0.57-0.77]) and calibration (HL χ2 5.6; P = .23) in the external validation cohort. The validated model was used to create the Web-based AF-TRACK calculator. Conclusion: The proposed risk model provides individualized estimates of the cumulative risk of complications of undergoing the AF ablation track. The AF-TRACK calculator is a validated, easy-to-use, Web-based clinical tool to calibrate the risk-to-benefit ratio of this treatment strategy.

4.
J Arrhythm ; 37(3): 626-634, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34141015

ABSTRACT

BACKGROUND: It is expected that ablation procedures will be increasingly offered to a more aged population affected with persistent AF (persAF); however, the clinical outcomes of ablation in this specific population are not well described. We aimed to analyze the efficacy and safety of CB-A in this group of patients compared with a younger cohort. METHODS AND RESULTS: Eighty-three patients with (persAF) aged ≥75 years (group 1; mean age 78.2 ± 3.1 years) and 166 patients also affected with persAF aged <75 years (group 2; mean age 64.3 ± 6.6 years) were included in the study. The primary outcome was freedom from recurrent sustained (>30 seconds) atrial arrhythmias without anti-arrhythmic medication after a blanking period of 3 months. At 2 years, clinical success was achieved in 108 out of 249 patients (43.4%). Median follow-up was 24 months (IQR: 18.4-25.5 months). Older patients suffered from more recurrences than those in the younger cohort ((53/83 patients, 63.9% vs 88/166 patients, 53.0%; P = .03). Thirty (12.0%) patients suffered a complication, but the incidence of complications was not different between both groups. The most frequent complication was transient phrenic nerve injury. CONCLUSIONS: The global 2 years efficacy of CB-A PVI in persAF is 43.4%. A lower success rate is achieved in the older patients (36.1%) compared to the younger age group (47.0%). However, the complication rate was not different between age groups.

5.
J Cardiovasc Med (Hagerstown) ; 21(9): 641-647, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32740497

ABSTRACT

AIMS: The main cause of atrial fibrillation recurrence after catheter ablation is pulmonary vein reconnection. The purpose of this retrospective study was to analyse the electophysiological findings in patients undergoing repeat procedures after an index cryoballoon ablation (CB-A) and presenting with permanency of pulmonary vein isolation (PVI) in all veins. In addition, we sought to compare the latter with a similar group of patients with reconnected veins at the redo procedure. METHODS: A total of 132 patients (81 men, 60.7 ±â€Š12.4 years) who underwent CB-A for paroxysmal atrial fibrillation (PAF) were enrolled. Indication for the redo procedure was symptomatic PAF in 83 (63%), persistent atrial fibrillation (PerAF) in 32 (24%) or persistent regular atrial tachycardia (RAT) in 17 (13%) patients. RESULTS: Seventy-five (57%) patients presented a pulmonary vein reconnection (pulmonary vein group) during the redo procedure, whereas 57 (43%) had no pulmonary vein reconnection (non-pulmonary vein group). The non-pulmonary vein group exhibited significantly more non-pulmonary vein foci and atrial flutters than the pulmonary vein group after induction protocol (51 vs. 24%, P = 0.002 and 67 vs. 36%, P = 0.003, respectively). Twenty-two (29.3%) patients of the pulmonary vein group and 20 (35%) patients of the non-pulmonary vein group had atrial fibrillation/RAT recurrence after a mean follow-up of 12.5 ±â€Š8 months. The survival analysis demonstrated no statistical significance in recurrence between both groups (log rank P = 0.358). CONCLUSION: Atrial fibrillation/RAT recurrence in patients after CB-A with durable PVI is significantly associated with non-pulmonary vein foci and atrial flutters. No statistically different success rate regarding atrial fibrillation/RAT freedom was detected between the pulmonary vein and non-pulmonary vein groups after redoing RF-CA.


Subject(s)
Action Potentials , Atrial Fibrillation/surgery , Atrial Flutter/surgery , Catheter Ablation , Cryosurgery , Heart Rate , Pulmonary Veins/surgery , Tachycardia, Supraventricular/surgery , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Atrial Flutter/diagnosis , Atrial Flutter/etiology , Atrial Flutter/physiopathology , Catheter Ablation/adverse effects , Cryosurgery/adverse effects , Electrophysiologic Techniques, Cardiac , Female , Humans , Male , Middle Aged , Pulmonary Veins/physiopathology , Recurrence , Reoperation , Retrospective Studies , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/etiology , Tachycardia, Supraventricular/physiopathology , Treatment Outcome
7.
J Interv Card Electrophysiol ; 58(3): 333-343, 2020 Sep.
Article in English | MEDLINE | ID: mdl-31520292

ABSTRACT

PURPOSE: The purpose of this study was to analyze the efficacy and complication rates of a one-stage left unilateral thoracoscopic hybrid procedure in a series of patients with persistent and long-standing persistent atrial fibrillation (AF) in a 2-year follow-up. METHODS: Fifty-one consecutive patients (34 males, 65.7 ± 8 years) having undergone hybrid isolation of pulmonary veins (PVs) and posterior wall of left atrium (LA) by means of left unilateral hybrid thoracoscopic ablation for symptomatic persistent (n = 22, 43%) and long-standing persistent atrial fibrillation (AF) (n = 29, 57%) were analyzed. RESULTS: At a mean follow-up of 24.9 ± 11.8 months (median 24), the success rate without antiarrhythmic therapy was achieved in 68.6% of patients. Procedure-related major complications were observed in 2 patients (4%) including diaphragmatic perforation and late pericardial tamponade requiring mini left-sided thoracotomy and pericardial drainage, respectively. The success rate did not significantly differ between persistent and long-standing persistent AF (respectively, 68.2 and 69%; P = 0.89). Patients with AF relapse during the blanking period were 3.8 times more likely to have AF recurrence after 3 months from the ablation procedure. CONCLUSION: The hybrid one-stage left unilateral thoracoscopic procedure exhibits encouraging results in the setting of both persistent and long-standing persistent AF after a 2-year follow-up, at a low rate of adverse events.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Follow-Up Studies , Humans , Male , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Treatment Outcome
9.
Pacing Clin Electrophysiol ; 42(11): 1456-1462, 2019 11.
Article in English | MEDLINE | ID: mdl-31579929

ABSTRACT

BACKGROUND: A left common pulmonary vein (LCPV) accounts as the most frequent pulmonary vein (PV) variation. Our aim was to compare the performance of radiofrequency (RF) versus second-generation cryoballoon (CB-A) ablation in patients with atrial fibrillation (AF) and LCPVs. METHODS: In a total cohort of 716 patients undergoing PV isolation with preprocedural CT-scanning, LCPV+ patients were selected with measurement of PV ostial area and trunk distance. All LCPV+ patients were matched between RF and CB-A group in a 1:1 ratio based on propensity scores, and compared for outcome. RESULTS: Left common pulmonary veins were found in 31% (88/283) RF versus 34% (146/433) CB-A patients, respectively, (P = .44). In the matched population of 83 LCPV+ patients in each group, electrical isolation could be achieved in all left-sided PVs. No significant difference was noted for the rate of AF/left atrial tachyarrhythmia (LAT) recurrence between RF and CB-A group (30% vs 28%, P = .86), with similar AF/LAT-free survival (log rank, P = .71). There were 48 patients with AF/LAT recurrence (29%) during the follow-up. Recurrence rate between paroxysmal versus persistent AF was 27/120 (22.5%) versus 21/46 (46%), P = .004. Cox proportional regression analysis withheld LA volume and persistent AF as independent variables to predict AF/LAT recurrence. No increased hazard for AF/LAT recurrence was observed for patients with a long (>15 mm) vs short (5-15 mm) LCPV trunk (OR 1.14, 95% CI 0.6-2.2, P = .7). CONCLUSIONS: In our study, equal efficacy and outcome was noted in LCPV+ patients between RF and CB-A technology.


Subject(s)
Anatomic Variation , Atrial Fibrillation/surgery , Catheter Ablation , Cryosurgery , Pulmonary Veins/anatomy & histology , Aged , Cryosurgery/instrumentation , Female , Humans , Male , Middle Aged , Pulmonary Veins/surgery
10.
J Arrhythm ; 35(3): 542-549, 2019 Jun.
Article in English | MEDLINE | ID: mdl-31293706

ABSTRACT

BACKGROUND: Radiofrequency (RF) ablation is a well-established approach to treat premature ventricular contractions (PVC) and is associated with good outcomes. AIM: The present study sought to analyze the acute efficacy and 1-year outcomes of PVC ablation using RF technology with an approach based on automated pace-mapping and contact force (CF) information. METHODS: Sixty-one consecutive patients (52.4% males, age 45.9 ± 12.5) underwent catheter ablation for symptomatic monomorphic PVC. All procedures were guided by a 3-dimensional mapping system; site of ablation was selected based on PASO™ aided pace-mapping; RF was started on the selected location when stable catheter position with >10 g of CF were obtained.The procedure was defined as acutely effective if the PVC was eliminated and it did not recur during within 30 minutes. Long-term efficacy was defined as a decrease by more than 95% at 1 year of the initial PVC burden at ECG Holter monitoring. RESULTS: The PVC ablation was performed in the right ventricular outflow tract in 37 patients (60.7%), left ventricle in 15 patients (24.6%), coronary cusps in 6 patients (9.8%), right ventricle in 3 patients (4.9%); PVC ablation was acutely successful in 59 of patients (96.7%). At 1-year efficacy was obtained in 57 patients (93.4%). No major complications occurred. Mean procedural and fluoroscopy time were 94.5 ± 20.9 and 4.3 ± 2.5 minutes respectively. CONCLUSION: Premature ventricular contraction RF ablation mainly guided by PASO™ and CF showed high success rate in both acute and 1-year follow-up (96.7% and 93.4% respectively). The best efficacy cut-off for RF ablation of PVCs has been identified in presence of both PASO™ ≥95% and CF >10 g.

11.
Pacing Clin Electrophysiol ; 42(7): 868-873, 2019 07.
Article in English | MEDLINE | ID: mdl-31037747

ABSTRACT

BACKGROUND: In the setting of second-generation cryoballoon (CB2) ablation, left atrial (LA) access is generally achieved using a standard sheath (SS) that is exchanged for the 15Fr cryoballoon delivery sheath (CBS) and dilator over a long wire (CBS over-the-wire technique, CBS-W). Our objective was to evaluate the direct use of the CBS to gain LA access, by advancing the latter over the trans-septal needle (CBS over-the-needle technique, CBS-N), under transesophageal echocardiographic (TEE) guidance. METHODS: Consecutive patients who underwent CB2 ablation with the CBS-N technique were evaluated for feasibility of gaining LA access using TEE guidance and fluoroscopy views. Complications related to the LA access were compared with a matched CBS-W control group. Subanalysis (30 CBS-W vs 30 CBS-N patients) evaluated time-to-LA of the CBS: time from superior vena cava (with SS vs CBS) to LA insertion of the CBS, after exchange or directly, respectively. RESULTS: LA access could be achieved in all 505 patients of the CBS-N group, without technique modification or additional equipment. Challenging interatrial septa were noted in 13% of these patients: previous atrial septal defect repair (1%), hypermobile (10%), aneurysmal (1%), and abnormally thickened/fibrotic (1%). Incidence of complications was similar to the CBS-W group. Subanalysis showed a shorter time-to-LA in the CBS-N versus CBS-W group, 72 ± 46 seconds versus 293 ± 180 seconds, P < .001. CONCLUSIONS: Our study showed that the CBS-N technique is feasible and safe under echocardiographic guidance. Without sheath exchange, it simplifies the CB2 procedure, is less costly, time sparing, and might reduce the risk of air embolism.


Subject(s)
Atrial Fibrillation/surgery , Atrial Septum/surgery , Balloon Occlusion/instrumentation , Cryosurgery/instrumentation , Needles , Pulmonary Veins/surgery , Belgium , Echocardiography , Feasibility Studies , Female , Fluoroscopy , Humans , Male , Middle Aged , Ultrasonography, Interventional
12.
J Atr Fibrillation ; 11(5): 2114, 2019.
Article in English | MEDLINE | ID: mdl-31139297

ABSTRACT

AIMS: To define predictors of long-term outcome of a first repeat ablation solely consisting of re-isolation of reconnected pulmonary veins (PVs). METHODS: Three hundred seven patients (age 59 ± 9%, 77% males, non-paroxysmal AF 43%) with recurrent AF after first PVI were studied. Re-isolation of reconnected PVs was guided by a circular mapping catheter and 3D mapping system using RF ablations. A PV was defined as "triggering" in case of spontaneous ectopy or AF paroxysms originating from the PV. RESULTS: After a mean follow-up of 5.05 ± 2.21 years, 194 (63.2%) patients (73.0% in PAF vs 50.4% in non-PAF, log Rank <0.001) were free from AF. A "triggering" PV was present in 48 (15.6%) during the first PVI and in 52 (16.9%) at repeat. Independent predictors of recurrence were a non-PAF type (HR: 1.814, 95%CI: 1.090 - 3.018, p=0.022) and early recurrence (≤ 3 months) after first PVI (HR: 1.632, 95%CI: 1.091 - 2.443, p=0.017) while a "triggering" PV at first or repeat was a predictor of good outcome (HR: 0.574; 95%CI: 0.344 - 0.959; p=0.034) in the multivariable analysis. CONCLUSIONS: A repeat ablation solely consisting of re-isolation of reconnected PVs results in a high degree of long-term AF freedom, especially in PAF and in case of a PV trigger at index or repeat. Patients with non-PAF or experiencing early AF recurrence after first PVI are less responsive.

13.
Indian Pacing Electrophysiol J ; 19(5): 171-177, 2019.
Article in English | MEDLINE | ID: mdl-31132410

ABSTRACT

BACKGROUND: Pulmonary vein isolation (PVI) modulates the intrinsic cardiac autonomic nervous system (ANS). We evaluated the impact of PVI on 5 non-invasive autonomic tests. METHODS: Thirty patients (76% male, mean age 60.37 ±â€¯9.02 years) with paroxysmal atrial fibrillation (AF) underwent cryoballoon-guided PVI. Five autonomic tests were performed 24hrs before and after PVI (N = 30) and repeated after 6months (N = 22). Parasympathetic function was measured by heart rate (HR) variability during deep breathing (E/I ratio, I-E difference), Valsalva maneuver (Valsalva-ratio) and head-up tilt test (30/15 ratio). Sympathetic function was measured by systolic BP response to sustained handgrip and 10' tilting and by diastolic BP response to cold water. RESULTS: 24hrs after PVI, baseline HR increased from 57.93 ±â€¯9.06 bpm to 71.10 ±â€¯12.75 bpm (p < 0.001). At 6 months, baseline HR was lower than immediately post-PVI (62.59 ±â€¯7.89 vs 71.36 ±â€¯13.58 bpm, p = 0.032) but still higher in comparison to pre-PVI (62.59 ±â€¯7.89 vs 57.09 ±â€¯8.80 bpm, p < 0.001). No differences were seen in baseline BP and parasympathetic tests acutely and at 6months. Besides an acute lowering in systolic BP increase during handgrip test, all sympathetic tests remained unchanged. CONCLUSIONS: An acute HR increase attenuated at 6months and an acute lowered systolic BP response to sustained handgrip were the only changes after cryoballoon-guided PVI. Non-invasive autonomic tests seem therefore not appropriate to evaluate the autonomic modulatory effect of PVI, either due to a too limited sensitivity or a too localized effect of PVI to influence test results.

14.
J Interv Card Electrophysiol ; 56(1): 1-7, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31028518

ABSTRACT

BACKGROUND: The creation of a posterior box isolation of the left atrium (LAPWI) in addition to pulmonary vein isolation (PVI) with the second-generation cryoballoon (CB-A) seems to offer promising clinical outcome in patients affected by persistent atrial fibrillation (PersAF). AIM: This work aims to study the clinical outcome of an ablation strategy based on the creation of a LAPWI during repeat procedures for recurrent AF after an index CB-A procedure for PersAF. METHODS AND RESULTS: A total of 33 patients having undergone a repeat procedure consisting in redo PVI plus LAPWI for recurrent PersAF with the CB-A after an index PVI ablation were retrospective included in our study. Electrical reconnection could be documented in 18 veins (13%). The LAPW was successfully isolated solely by CB-A ablation in 30 out of 33 (91%) patients; in the remaining 3 patients, isolation of the LAPW was completed by focal tip-irrigated RF ablation. The mean number of CB-A applications required for the superior portion of the LAPW and the inferior portion of the LAPW creation were 5.4 ± 0.9 and 4 ± 0.6, respectively. After a mean follow-up of 11.8 ± 3 months, 28 patients (85%) did not experience recurrence of any atrial arrhythmias during follow-up, without the need of further ablation or class I or III AADs. CONCLUSION: Left posterior wall isolation with the CB-A is feasible and safe during repeat ablation procedures for recurrent PersAF. In our study, the 12-month freedom from any arrhythmia was 85% following this ablation strategy.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Cryosurgery/methods , Female , Follow-Up Studies , Heart Atria/surgery , Humans , Male , Middle Aged , Pulmonary Veins/surgery , Recurrence , Retrospective Studies
15.
J Interv Card Electrophysiol ; 54(1): 1-8, 2019 Jan.
Article in English | MEDLINE | ID: mdl-29679186

ABSTRACT

PURPOSE: Cryoballoon (CB) technology in the context of anatomical pulmonary vein (PV) variants might hypothetically hamper successful PV isolation (PVI). Our aim was to assess the impact of a right middle PV (RMPV) in the setting of second-generation cryoballoon (CB advance-CB-A), on procedural parameters and on mid-term follow-up. METHODS: Consecutive patients with AF presenting RMPV (RMPV+) at the pre-procedural computed tomography who underwent PVI by CB-A were enrolled. Comparison with propensity score-matched patients without RMPV (RMPV-) was performed. Acute procedural parameters and clinical follow-up were assessed. RESULTS: A total of 240 patients (80 RMPV+) were included in the analysis. Twelve of 80 (15%) RMPV+ patients underwent a direct cryo-application in this variant and accomplished the isolation without phrenic nerve palsy, whereas in 25 of 80 (31%) RMPV+ patients, the RMPVs were not targeted directly nor indirectly (by co-occlusion during application at a major PV). At a median follow-up of 17.3 [interquartile range 11.3-26.5] months, there was no significant difference in AF-free survival between RMPV+ and RMPV- patients (78.8 vs 78.1%, P = 1.00), and the recurrence of atrial arrhythmias among patients with versus without an intentional or indirect cryo-application to the RMPV was not different (22 vs 20%, P = 1.00). CONCLUSIONS: Mid-term outcome after CB-A ablation did not differ between RMPV+ and RMPV- patients. Within RMPV+ patients, outcome was similar between those with versus without a cryo-application (either direct or indirect) to the additional vein.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Cryosurgery/methods , Pulmonary Veins/surgery , Aged , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/mortality , Catheter Ablation/adverse effects , Cohort Studies , Cryosurgery/instrumentation , Echocardiography, Transesophageal/methods , Female , Follow-Up Studies , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Propensity Score , Recurrence , Retrospective Studies , Risk Assessment , Severity of Illness Index , Statistics, Nonparametric , Survival Rate , Treatment Outcome
16.
Heart Rhythm ; 16(2): 187-196, 2019 02.
Article in English | MEDLINE | ID: mdl-30125716

ABSTRACT

BACKGROUND: The second-generation cryoballoon (CB) is effective in achieving pulmonary vein isolation. Continuous monitoring would eliminate any over- or underestimated freedom from atrial fibrillation (AF) postablation. OBJECTIVE: The purpose of this study was to differentiate between arrhythmias occurring after cryoballoon ablation (CBA), detecting true AF in symptomatic patients and detecting silent subclinical AF. METHODS: Between June 2012 and January 2015, 54 patients with a preexisting cardiac implantable electronic device (CIED) who had undergone CBA for paroxysmal atrial fibrillation (PAF) were included in our retrospective study. Regular CIED controls, physical examination, and ECG recordings were performed by an experienced cardiologist blinded to the ablation procedure. Data on any hospitalization during follow-up were gathered. Patients were encouraged to note all clinical symptoms during follow-up. RESULTS: Continuous monitoring showed a success rate of 83.3% after 1 year and 75.93% after 3 years of follow-up. During the first year, 68% of episodes of palpitations after ablation were due to sinus tachycardia, nonsustained ventricular tachycardia, or supraventricular tachycardia. AF recurrence was detected in 15.6% of asymptomatic patients during follow-up. Total AF burden post-CBA had decreased to 0.64% ± 4.34% (P <.001) during long-term follow-up of 3.3 years. CONCLUSION: Although this is a selected group of patients with a preexisting CIED, continuous monitoring showed freedom from AF in 83.3% of patients post-CBA after 1 year and 75.93% after 3 years of follow-up.


Subject(s)
Atrial Fibrillation/physiopathology , Cryosurgery/adverse effects , Electrodes, Implanted , Heart Conduction System/physiopathology , Heart Rate/physiology , Monitoring, Physiologic/instrumentation , Tachycardia, Ventricular/physiopathology , Atrial Fibrillation/surgery , Equipment Design , Female , Follow-Up Studies , Humans , Male , Middle Aged , Postoperative Period , Pulmonary Veins/surgery , Retrospective Studies , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Telemetry/methods
17.
Heart Rhythm ; 16(6): 879-887, 2019 06.
Article in English | MEDLINE | ID: mdl-30594641

ABSTRACT

BACKGROUND: Abnormal delayed electrograms (EGMs) from the anterior wall of the right ventricular outflow tract (RVOT) epicardium have become the ablation target in Brugada syndrome (BrS). OBJECTIVE: The aim of this study was to analyze the safety, feasibility, and efficacy of a novel hybrid thoracoscopic approach to perform epicardial RVOT radiofrequency ablation in BrS. METHODS: Thirty-six patients with BrS (26 men (72.2%); mean age 36.6±15.8 years; range 3-63 years) who underwent hybrid thoracoscopic epicardial ablation of RVOT from January 2016 to April 2018 were included in this study. Two expert electrophysiologists analyzed the EGMs during ajmaline challenge and guided the surgeon to perform ablation. Ajmaline challenge was repeated after 1 month to assess the absence of the BrS electrocardiographic pattern. Patients were followed by remote monitoring and outpatient visits every 6 months. RESULTS: The elimination of all abnormal EGMs was achieved in 94.4% of patients. After a mean follow-up of 16 ± 8 months (range 6-30 months), freedom from ventricular arrhythmias was obtained in 7 (77.8%) patients in secondary prevention 9/36 (25%) and in 24 (100%) patients in primary prevention 24/36 (75%). Major complications were observed in 1 patient (2.8%), who experienced late cardiac tamponade. CONCLUSION: Hybrid thoracoscopic epicardial RVOT ablation in BrS is a safe and feasible approach, allowing direct visualization of ablation during radiofrequency delivery. Because of ventricular arrhythmia recurrences, implantable cardioverter-defibrillator implantation is still mandatory in patients treated in secondary prevention and with high risk.


Subject(s)
Brugada Syndrome , Cardiac Tamponade , Catheter Ablation , Electrophysiologic Techniques, Cardiac/methods , Heart Ventricles , Postoperative Complications/diagnosis , Tachycardia, Ventricular , Thoracic Surgery, Video-Assisted/methods , Adult , Ajmaline/pharmacology , Anti-Arrhythmia Agents/pharmacology , Brugada Syndrome/diagnosis , Brugada Syndrome/physiopathology , Brugada Syndrome/surgery , Cardiac Tamponade/diagnosis , Cardiac Tamponade/etiology , Catheter Ablation/adverse effects , Catheter Ablation/instrumentation , Catheter Ablation/methods , Feasibility Studies , Female , Heart Ventricles/physiopathology , Heart Ventricles/surgery , Humans , Male , Pericardium/surgery , Recurrence , Risk Adjustment , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/prevention & control
18.
Circ J ; 83(1): 84-90, 2018 12 25.
Article in English | MEDLINE | ID: mdl-30429412

ABSTRACT

BACKGROUND: Pulmonary vein isolation (PVI) by means of cryoballoon is increasingly being used for the treatment of atrial fibrillation (AF). This study assessed whether the left atrial volume index (LAVI) predicts AF recurrence following PVI by means of 2nd-generation cryoballoon (Cryoballoon Advance; CB-A) when comparing persistent AF (PeAF) and paroxysmal AF (PAF). Methods and Results: Patients with drug-resistant AF and undergoing preprocedural computed tomography (CT) and PVI with CB-A were included. LAV was estimated from 3D CT images. A total of 417 patients with AF were included (95 PeAF, 322 PAF patients). After a mean of 22.1±9.4 months follow-up, 45/95 (47%) PeAF patients and 254/322 (79%) PAF patients had no recurrence. LAVI was an independent predictor for AF recurrence in PeAF patients (hazard ratio 1.042 per 1 mL/m2; 95% confidence interval 1.006-1.080, P=0.02), but not in PAF patients. In PeAF patients with LAVI ≤61 mL/m2, the freedom from recurrence was 78.5% vs. 22.2% in those with LAVI >61 mL/m2 (hazard ratio 5.771, 95% confidence interval 2.434-13.682, P<0.001), and the mid-term success rate was comparable with PAF patients. CONCLUSIONS: LAVI predicted AF recurrence after PVI using CB-A in PeAF patients but not in PAF patients. If LAVI was ≤61 mL/m2, the mid-term efficacy among PeAF patients was equivalent to that for PAF patients.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation , Cryosurgery , Pulmonary Veins/surgery , Adult , Aged , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/physiopathology , Female , Follow-Up Studies , Humans , Male , Middle Aged , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/physiopathology , Recurrence , Tomography, X-Ray Computed
19.
Cardiovasc Ultrasound ; 16(1): 19, 2018 Sep 25.
Article in English | MEDLINE | ID: mdl-30249263

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is the most common arrhythmia worldwide. Nowadays, AF ablation is a valuable treatment option. It has been shown that the left atrium (LA) diameter is a predictor of AF recurrence after cryoballoon ablation (CBA). Since it does not reflect the true LA size, we compared the role of different LA anatomical parameters using echocardiography for the prediction of AF recurrence after CBA. METHODS: We retrospectively included 209 patients (mean age 56.1 ± 13.6 years, male 62%) with paroxysmal AF undergoing CBA. A transthoracic echocardiography was performed in all patients. RESULTS: At a mean follow-up of 16.9 ± 6.3 months, AF recurred in 25.4% of the patients. LA anterior - posterior diameter (LAD), LA minimum volume (LAmin) and early AF recurrence were independent predictors of recurrence. Based on receiver operating characteristics, cut - off values for LAD and, LAmin were 41 mm, 23.69 mL, respectively. The negative predictive values for recurrence were 73% and 87.3% respectively. In patients with AF recurrence, a significant proportion (30.2%) showed LA longitudinal remodeling (LA superior - inferior diameter) even though classically measured LAD was normal. CONCLUSIONS: Longitudinal LA remodeling plays an additional role for predicting AF recurrence after CBA, in patients without LAD dilation. Moreover, LAmin had a high negative predictive value and was an independent predictor of AF recurrence. Therefore, a more complete LA anatomical assessment allows a better prediction of AF recurrences after CBA.


Subject(s)
Atrial Fibrillation/diagnosis , Atrial Remodeling , Catheter Ablation/instrumentation , Echocardiography/methods , Heart Atria/diagnostic imaging , Tachycardia, Paroxysmal/diagnosis , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Equipment Design , Female , Heart Atria/physiopathology , Humans , Male , Middle Aged , Prognosis , ROC Curve , Recurrence , Retrospective Studies , Tachycardia, Paroxysmal/physiopathology , Tachycardia, Paroxysmal/surgery , Treatment Outcome
20.
J Atr Fibrillation ; 10(6): 1855, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29988256

ABSTRACT

AIMS: Real Time Recordings (RTR) of pulmonary vein (PV) activity provide important information in the setting of the 2nd generation Cryoballoon (CB-A), as a funcion of time to isolation. Visualization of RTR with the standard inner lumen mapping catheter (ILMC) 20mm Achieve (AC) is possible in roughly 50% of PVs. A novel 25mm-Achieve Advance (AC-A) has been developed with the aim of increasing the detection of RTR. The purpose of this study is to compare the AC-A with the AC, to feasibility and improvement of RTR. METHODS: We assigned 50 patients with paroxysmal or persistent atrial fibrillation to CB-A PVI, using the AC-A as ILMC. We compared this group with 50 patients, matched for age and left atrial volume, who previously underwent the CB-A PVI using the AC. RESULTS: RTR were more frequently observed with the AC-A than with the AC (74% vs 49%; p= 0.02). RTR in the left superior PVs was similar in both groups (74% vs 72%, p= 0.8). RTR with the AC-A were equally appreciated in left or right sided, superior or inferior PVs. No significant differences were found in terms of feasibility, procedure fluoroscopy and freezing times, nadir temperatures, and acute PVI. CONCLUSIONS: CB-A PVI with the AC-A is feasible and safe in all PVs. The AC-A has proven significantly superior in visualising RTR if compared to the AC, affording RTR in 74% of PVs.

SELECTION OF CITATIONS
SEARCH DETAIL
...