Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Radiol Prot ; 42(3)2022 09 07.
Article in English | MEDLINE | ID: mdl-35917802

ABSTRACT

The facilities now available on linear accelerators for external beam radiotherapy enable radiation fields to be conformed to the shapes of tumours with a high level of precision. However, in order for the treatment delivered to take advantage of this, the patient must be positioned on the couch with the same degree of accuracy. Kilovoltage cone beam computed tomography systems are now incorporated into radiotherapy linear accelerators to allow imaging to be performed at the time of treatment, and image-guided radiation therapy is now standard in most radiotherapy departments throughout the world. However, because doses from imaging are much lower than therapy doses, less effort has been put into optimising radiological protection of imaging protocols. Standard imaging protocols supplied by the equipment vendor are often used with little adaptation to the stature of individual patients, and exposure factors and field sizes are frequently larger than necessary. In this study, the impact of using standard protocols for imaging anatomical phantoms of varying size from a library of 193 adult phantoms has been evaluated. Monte Carlo simulations were used to calculate doses for organs and tissues for each phantom, and results combined in terms of size-specific effective dose (SED). Values of SED from pelvic scans ranged from 11 mSv to 22 mSv for male phantoms and 8 mSv to 18 mSv for female phantoms, and for chest scans from 3.8 mSv to 7.6 mSv for male phantoms and 4.6 mSv to 9.5 mSv for female phantoms. Analysis of the results showed that if the same exposure parameters and field sizes are used, a person who is 5 cm shorter will receive a size SED that is 3%-10% greater, while a person who is 10 kg lighter will receive a dose that is 10%-14% greater compared with the average size.


Subject(s)
Cone-Beam Computed Tomography , Radiotherapy, Image-Guided , Adult , Cone-Beam Computed Tomography/methods , Female , Humans , Male , Monte Carlo Method , Phantoms, Imaging , Radiation Dosage , Radiotherapy, Image-Guided/methods
2.
Phys Med ; 90: 53-65, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34562809

ABSTRACT

Improvements in delivery of radiation dose to target tissues in radiotherapy have increased the need for better image quality and led to a higher frequency of imaging patients. Imaging for treatment planning extends to function and motion assessment and devices are incorporated into medical linear accelerators (linacs) so that regions of tissue can be imaged at time of treatment delivery to ensure dose distributions are delivered as accurately as possible. A survey of imaging in 97 radiotherapy centres in nine countries on six continents has been undertaken with an on-line questionnaire administered through the International Commission on Radiological Protection mentorship programme to provide a snapshot of imaging practices. Responses show that all centres use CT for planning treatments and many utilise additional information from magnetic resonance imaging and positron emission tomography scans. Most centres have kV cone beam CT attached to at least some linacs and use this for the majority of treatment fractions. The imaging options available declined with the human development index (HDI) of the country, and the frequency of imaging during treatment depended more on country than treatment site with countries having lower HDIs imaging less frequently. The country with the lowest HDI had few kV imaging facilities and relied on MV planar imaging intermittently during treatment. Imaging protocols supplied by vendors are used in most centres and under half adapt exposure conditions to individual patients. Recording of patient doses, a knowledge of which is important in optimisation of imaging protocols, was limited primarily to European countries.


Subject(s)
Radiation Oncology , Radiotherapy, Image-Guided , Cone-Beam Computed Tomography , Humans , Particle Accelerators , Phantoms, Imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Surveys and Questionnaires
3.
Folia Morphol (Warsz) ; 76(4): 574-581, 2017.
Article in English | MEDLINE | ID: mdl-28553860

ABSTRACT

BACKGROUND: Frontal aslant tract (FAT) is a white matter bundle connecting the pre-supplementary motor area (pre-SMA) and the supplementary motor area (SMA) with the inferior frontal gyrus (IFG). The purpose of the present study was to evaluate the anatomical variability of FAT. MATERIALS AND METHODS: Total number of fibres and the lateralisation index (LI) were calculated. We attempted to find factors contributing to the diversity of FAT regarding IFG terminations to the pars opercularis (IFG-Op) and to the pars triangularis (IFG-Tr). Magnetic resonance imaging of adult patients with diffusion tensor imaging (DTI) with total number of 98 hemispheres composed a cohort. V-shaped operculum was the most common (60.5%). RESULTS: Total number of FAT fibres had widespread and unimodal distribution (6 to 1765; median: 160). Left lateralisation was noted in 64.3% of cases and was positively correlated with total number of FAT fibres and the bundle projecting to IFG-Op (p < 0.01). LI correlated with total number of FAT fibres (r = 0.43, p < 0.01). FAT projected predominantly to IFG-Op (88.9%; 88 of 99). Only in 3 (3.1%) cases more fibres terminated in IFG-Tr than in IFG-Op. Total number of FAT fibres and number of fibres terminating at IFG-Op did not correlate with the ratio of fibre numbers: FAT/IFG-Op, FAT/IFG-Tr and IFG-Op/IFG-Tr (p > 0.05). The greater total number of fibres to IFG-Tr was, the higher were the ratios of IFG-Tr/ /FAT (r = 0.57, p < 0.01) and IFG-Tr/IFG-Op (r = 0.32, p = 0.04). CONCLUSIONS: Among the IFG, the major termination of FAT is IFG-Op. Whereas the IFG-Tr projection seems to be related to the expansion of the entire FAT bundle regardless of side, domination and handedness. Nevertheless, FAT features a significant anatomical variability which cannot be explained in terms of DTI findings.

SELECTION OF CITATIONS
SEARCH DETAIL
...