1.
Transplant Direct ; 10(4): e1609, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38481967

ABSTRACT

Background: Brief normothermic machine perfusion is increasingly used to assess and recondition grafts before transplant. During normothermic machine perfusion, metabolic activity is typically maintained using red blood cell (RBC)-based solutions. However, the utilization of RBCs creates important logistical constraints. This study explored the feasibility of human kidney normothermic perfusion using William's E-based perfusate with no additional oxygen carrier. Methods: Sixteen human kidneys declined for transplant were perfused with a perfusion solution containing packed RBCs or William's E medium only for 6 h using a pressure-controlled system. The temperature was set at 37 °C. Renal artery resistance, oxygen extraction, metabolic activity, energy metabolism, and histological features were evaluated. Results: Baseline donor demographics were similar in both groups. Throughout perfusion, kidneys perfused with William's E exhibited improved renal flow (P = 0.041) but similar arterial resistance. Lactic acid levels remained higher in kidneys perfused with RBCs during the first 3 h of perfusion but were similar thereafter (P = 0.95 at 6 h). Throughout perfusion, kidneys from both groups exhibited comparable behavior regarding oxygen consumption (P = 0.41) and reconstitution of ATP tissue concentration (P = 0.55). Similarly, nicotinamide adenine dinucleotide levels were preserved during perfusion. There was no evidence of histological damage caused by either perfusate. Conclusions: In human kidneys, William's E medium provides a logistically convenient, off-the-shelf alternative to packed RBCs for up to 6 h of normothermic machine perfusion.

2.
J Clin Med ; 9(1)2020 Jan 18.
Article in English | MEDLINE | ID: mdl-31963739

ABSTRACT

Ex situ machine perfusion is a promising technology to help improve organ viability prior to transplantation. However, preclinical studies using discarded human livers to evaluate therapeutic interventions and optimize perfusion conditions are limited by significant graft heterogeneity. In order to improve the efficacy and reproducibility of future studies, a split-liver perfusion model was developed to allow simultaneous perfusion of left and right lobes, allowing one lobe to serve as a control for the other. Eleven discarded livers were surgically split, and both lobes perfused simultaneously on separate perfusion devices for 3 h at subnormothermic temperatures. Lobar perfusion parameters were also compared with whole livers undergoing perfusion. Similar to whole-liver perfusions, each lobe in the split-liver model exhibited a progressive decrease in arterial resistance and lactate levels throughout perfusion, which were not significantly different between right and left lobes. Split liver lobes also demonstrated comparable energy charge ratios. Ex situ split-liver perfusion is a novel experimental model that allows each graft to act as its own control. This model is particularly well suited for preclinical studies by avoiding the need for large numbers of enrolled livers necessary due to the heterogenous nature of discarded human liver research.

3.
PLoS One ; 15(1): e0228011, 2020.
Article in English | MEDLINE | ID: mdl-31978172

ABSTRACT

There continues to be a significant shortage of donor livers for transplantation. One impediment is the discard rate of fatty, or steatotic, livers because of their poor post-transplant function. Steatotic livers are prone to significant ischemia-reperfusion injury (IRI) and data regarding how best to improve the quality of steatotic livers is lacking. Herein, we use normothermic (37°C) machine perfusion in combination with metabolic and lipidomic profiling to elucidate deficiencies in metabolic pathways in steatotic livers, and to inform strategies for improving their function. During perfusion, energy cofactors increased in steatotic livers to a similar extent as non-steatotic livers, but there were significant deficits in anti-oxidant capacity, efficient energy utilization, and lipid metabolism. Steatotic livers appeared to oxidize fatty acids at a higher rate but favored ketone body production rather than energy regeneration via the tricyclic acid cycle. As a result, lactate clearance was slower and transaminase levels were higher in steatotic livers. Lipidomic profiling revealed ω-3 polyunsaturated fatty acids increased in non-steatotic livers to a greater extent than in steatotic livers. The novel use of metabolic and lipidomic profiling during ex situ normothermic machine perfusion has the potential to guide the resuscitation and rehabilitation of steatotic livers for transplantation.


Subject(s)
Fatty Liver/metabolism , Lipidomics , Metabolomics , Perfusion , Resuscitation , Temperature , Adenosine Triphosphate/biosynthesis , Bile Acids and Salts/metabolism , Fatty Acids/metabolism , Fatty Liver/pathology , Fatty Liver/physiopathology , Glucose/metabolism , Hemodynamics , Humans , Liver/pathology , Liver/physiopathology , Liver Function Tests , Oxidation-Reduction , Oxidative Stress , Vascular Resistance
4.
Am J Transplant ; 19(10): 2814-2824, 2019 10.
Article in English | MEDLINE | ID: mdl-30938927

ABSTRACT

Normothermic machine perfusion presents a novel platform for pretransplant assessment and reconditioning of kidney grafts. Maintaining the metabolic activity of a preserved graft at physiologic levels requires an adequate oxygen supply, typically delivered by crystalloid solutions supplemented with red blood cells. In this study, we explored the feasibility of using a synthetic hemoglobin-based oxygen carrier (HBOC) in human kidney normothermic perfusion. Fourteen discarded human kidneys were perfused for 6 hours at a mean temperature of 37°C using a pressure-controlled system. Kidneys were perfused with a perfusion solution supplemented with either HBOC (n = 7) or packed red blood cells (PRBC) (n = 7) to increase oxygen-carrying capacity. Renal artery resistance, oxygen extraction, metabolic activity, energy stores, and histological features were evaluated. Throughout perfusion, kidneys from both groups exhibited comparable behavior regarding vascular flow (P = .66), oxygen consumption (P = .88), and reconstitution of tissue adenosine triphosphate (P = .057). Lactic acid levels were significantly higher in kidneys perfused with PRBC (P = .007). Histological findings were comparable between groups, and there was no evidence of histological damage caused by the HBOC. This feasibility experiment demonstrates that a HBOC solution can offer a logistically more convenient off-the-shelf alternative to PRBC in normothermic machine perfusion of human kidneys.


Subject(s)
Blood Substitutes/pharmacology , Hemoglobins/pharmacology , Kidney/drug effects , Organ Preservation Solutions/chemistry , Organ Preservation/methods , Oxygen/metabolism , Reperfusion Injury/prevention & control , Adult , Aged , Cells, Cultured , Erythrocytes/chemistry , Extracorporeal Circulation , Female , Follow-Up Studies , Humans , Male , Middle Aged , Oxygen Consumption , Perfusion , Tissue Survival , Tissue and Organ Harvesting/methods
5.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 3128-3131, 2018 Jul.
Article in English | MEDLINE | ID: mdl-30441057

ABSTRACT

This paper introduces a non-invasive, contrastenhanced ultrasound (CEUS) infusion method to quantify the health of viable donor livers. The method uses the infusion of microbubbles and their destruction and subsequent replenishment to measure the perfusion rate in the liver microvasculature. The proposed method improves on the previous parameter extraction approaches applied to the flashreplenishment technique by addressing the effects of the microbubble mixing within the perfusate bath and destruction rate. By doing so, the tissue perfusion rate can be extracted from the data even though the microbubble concentration is not constant throughout image acquisition. The measured changes in the tissue perfusion rate showed that CEUS infusion is a viable biomarker for assessing liver health.


Subject(s)
Liver , Animals , Contrast Media , Microbubbles , Perfusion , Swine , Ultrasonography