Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 49
Filter
1.
Lab Invest ; 103(4): 100052, 2023 04.
Article in English | MEDLINE | ID: mdl-36870295

ABSTRACT

Formalin-fixed, paraffin-embedded tissues represent a majority of all biopsy specimens commonly analyzed by histologic or immunohistochemical staining with adhesive coverslips attached. Mass spectrometry (MS) has recently been used to precisely quantify proteins in samples consisting of multiple unstained formalin-fixed, paraffin-embedded sections. Here, we report an MS method to analyze proteins from a single coverslipped 4-µm section previously stained with hematoxylin and eosin, Masson trichrome, or 3,3'-diaminobenzidine-based immunohistochemical staining. We analyzed serial unstained and stained sections from non-small cell lung cancer specimens for proteins of varying abundance (PD-L1, RB1, CD73, and HLA-DRA). Coverslips were removed by soaking in xylene, and after tryptic digestion, peptides were analyzed by targeted high-resolution liquid chromatography with tandem MS with stable isotope-labeled peptide standards. The low-abundance proteins RB1 and PD-L1 were quantified in 31 and 35 of 50 total sections analyzed, respectively, whereas higher abundance CD73 and HLA-DRA were quantified in 49 and 50 sections, respectively. The inclusion of targeted ß-actin measurement enabled normalization in samples where residual stain interfered with bulk protein quantitation by colorimetric assay. Measurement coefficient of variations for 5 replicate slides (hematoxylin and eosin stained vs unstained) from each block ranged from 3% to 18% for PD-L1, from 1% to 36% for RB1, 3% to 21% for CD73, and 4% to 29% for HLA-DRA. Collectively, these results demonstrate that targeted MS protein quantification can add a valuable data layer to clinical tissue specimens after assessment for standard pathology end points.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Humans , B7-H1 Antigen , HLA-DR alpha-Chains , Paraffin Embedding/methods , Hematoxylin , Eosine Yellowish-(YS) , Proteins/metabolism , Peptides , Biomarkers , Tandem Mass Spectrometry/methods , Formaldehyde/chemistry , Tissue Fixation
2.
Arch Toxicol ; 97(3): 769-785, 2023 03.
Article in English | MEDLINE | ID: mdl-36481916

ABSTRACT

Drug-induced pancreatic injury (DIPI) is an issue seen in drug development both in nonclinical and clinical contexts. DIPI is typically monitored by measurement of lipase and/or amylase, however, both enzymes lack sensitivity and specificity. Although candidate protein biomarkers specific to pancreas exist, antibody-based assay development is difficult due to their small size or the rapid cleavage by proteolytic enzymes released during pancreatic injury. Here we report the development of a novel multiplexed immunoaffinity-based liquid chromatography mass spectrometric assay (IA-LC-MS/MS) for trypsinogen activation peptide (TAP) and carboxypeptidases A1 and A2 (CPA1, CPA2). This method is based on the enzymatic digestion of the target proteins, immunoprecipitation of the peptides with specific antibodies and LC-MS/MS analysis. This assay was used to detect TAP, CPA1, and CPA2 in 470 plasma samples collected from 9 in-vivo rat studies with pancreatic injury and 8 specificity studies with injury in other organs to assess their performance in monitoring exocrine pancreas injury. The TAP, CPA1, and CPA2 response was compared to histopathology, lipase, amylase and microRNA217. In summary, TAP, CPA1, and CPA2 proteins measured in rat plasma were sensitive and specific biomarkers for monitoring drug-induced pancreatic injury; outperforming lipase and amylase both by higher sensitivity of detection and by sustained increases in plasma observed over a longer time period. These protein-based assays and potentially others under development, are valuable tools for use in nonclinical drug development and as future translatable biomarkers for assessment in clinical settings to further improve patient safety.


Subject(s)
Amylases , Tandem Mass Spectrometry , Rats , Animals , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Carboxypeptidases A/metabolism , Biomarkers , Lipase
3.
J Clin Pathol ; 75(9): 636-642, 2022 Sep.
Article in English | MEDLINE | ID: mdl-34353876

ABSTRACT

AIMS AND METHODS: Accurate protein measurements using formalin-fixed biopsies are needed to improve disease characterisation. This feasibility study used targeted and global mass spectrometry (MS) to interrogate a spectrum of disease severities using 19 ulcerative colitis (UC) biopsies. RESULTS: Targeted assays for CD8, CD19, CD132 (interleukin-2 receptor subunit gamma/common cytokine receptor gamma chain), FOXP3 (forkhead box P3) and IL17RA (interleukin 17 receptor A) were successful; however, assays for IL17A (interleukin 17A), IL23 (p19) (interleukin 23, alpha subunit p19) and IL23R (interleukin 23 receptor) did not permit target detection. Global proteome analysis (4200 total proteins) was performed to identify pathways associated with UC progression. Positive correlation was observed between histological scores indicating active colitis and neutrophil-related measurements (R2=0.42-0.72); inverse relationships were detected with cell junction targets (R2=0.49-0.71) and ß-catenin (R2=0.51-0.55) attributed to crypt disruption. An exploratory accuracy assessment with Geboes Score and Robarts Histopathology Index cut-offs produced sensitivities/specificities of 72.7%/75.0% and 100.0%/81.8%, respectively. CONCLUSIONS: Pathologist-guided MS assessments provide a complementary approach to histological scoring systems. Additional studies are indicated to verify the utility of this novel approach.


Subject(s)
Colitis, Ulcerative , Biopsy , Colitis, Ulcerative/pathology , Colonoscopy , Humans , Interleukin-23 , Intestinal Mucosa/pathology , Proteomics , Severity of Illness Index
4.
Sci Rep ; 10(1): 9805, 2020 06 17.
Article in English | MEDLINE | ID: mdl-32555523

ABSTRACT

New therapeutics targeting immune checkpoint proteins have significantly advanced treatment of non-small cell lung cancer (NSCLC), but protein level quantitation of drug targets presents a critical problem. We used multiplexed, targeted mass spectrometry (MS) to quantify immunotherapy target proteins PD-1, PD-L1, PD-L2, IDO1, LAG3, TIM3, ICOSLG, VISTA, GITR, and CD40 in formalin-fixed, paraffin-embedded (FFPE) NSCLC specimens. Immunohistochemistry (IHC) and MS measurements for PD-L1 were weakly correlated, but IHC did not distinguish protein abundance differences detected by MS. PD-L2 abundance exceeded PD-L1 in over half the specimens and the drug target proteins all displayed different abundance patterns. mRNA correlated with protein abundance only for PD-1, PD-L1, and IDO1 and tumor mutation burden did not predict abundance of any protein targets. Global proteome analyses identified distinct proteotypes associated with high PD-L1-expressing and high IDO1-expressing NSCLC. MS quantification of multiple drug targets and tissue proteotypes can improve clinical evaluation of immunotherapies for NSCLC.


Subject(s)
Carcinoma, Non-Small-Cell Lung/drug therapy , Drug Delivery Systems , Immune Checkpoint Inhibitors/therapeutic use , Lung Neoplasms/drug therapy , Humans , Mass Spectrometry , Neoplasm Proteins/antagonists & inhibitors
5.
Clin Chem ; 66(2): 282-301, 2020 02 01.
Article in English | MEDLINE | ID: mdl-32040572

ABSTRACT

Immunoaffinity-mass spectrometry (IA-MS) is an emerging analytical genre with several advantages for profiling and determination of protein biomarkers. Because IA-MS combines affinity capture, analogous to ligand binding assays (LBAs), with mass spectrometry (MS) detection, this platform is often described using the term hybrid methods. The purpose of this report is to provide an overview of the principles of IA-MS and to demonstrate, through application, the unique power and potential of this technology. By combining target immunoaffinity enrichment with the use of stable isotope-labeled internal standards and MS detection, IA-MS achieves high sensitivity while providing unparalleled specificity for the quantification of protein biomarkers in fluids and tissues. In recent years, significant uptake of IA-MS has occurred in the pharmaceutical industry, particularly in the early stages of clinical development, enabling biomarker measurement previously considered unattainable. By comparison, IA-MS adoption by CLIA laboratories has occurred more slowly. Current barriers to IA-MS use and opportunities for expanded adoption are discussed. The path forward involves identifying applications for which IA-MS is the best option compared with LBA or MS technologies alone. IA-MS will continue to benefit from advances in reagent generation, more sensitive and higher throughput MS technologies, and continued growth in use by the broader analytical community. Collectively, the pursuit of these opportunities will secure expanded long-term use of IA-MS for clinical applications.


Subject(s)
Chromatography, Liquid/methods , Immunoassay/methods , Tandem Mass Spectrometry/methods , Biological Assay , Biomarkers/analysis , Humans , Proteins/analysis , Sensitivity and Specificity
6.
Lab Invest ; 100(6): 874-886, 2020 06.
Article in English | MEDLINE | ID: mdl-31896815

ABSTRACT

Immunohistochemistry (IHC) using formalin-fixed, paraffin embedded (FFPE) tissue is limited by epitope masking, posttranslational modification and immunoreactivity loss that occurs in stored tissue by poorly characterized mechanisms. Conformational epitopes recognized by many programmed-death-ligand-1 (PD-L1) IHC assays are particularly susceptible to degradation and provide an ideal model for understanding signal loss in stored FFPE tissue. Here we assessed 1206 tissue sections to evaluate environmental factors impacting immunoreactivity loss. PD-L1 IHC using four antibodies (22C3, 28-8, E1L3N, and SP142), raised against intracellular and extracellular epitopes, was assessed in stored FFPE tissue alongside quantitative mass spectrometry (MS). Global proteome analyses were used to assess proteome-wide oxidation across an inventory of 3041 protein groups (24,737 distinct peptides). PD-L1 quantitation correlated well with IHC expression on unaged sections (R2 = 0.744; P < 0.001), with MS demonstrating no loss of PD-L1 protein, even in sections with significant signal loss by IHC impacting diagnostic category. Clones 22C3 and 28-8 were most susceptible to signal loss, with E1L3N demonstrating the most robust signal (56%, 58%, and 33% reduction respectively; p < 0.05). Increased humidity and temperature resulted in significant acceleration of immunoreactivity loss, which was mitigated by storage with desiccant. MS demonstrated only modest oxidation of 274 methionine-containing peptides and aligned with IHC results suggesting peptide oxidation is not a major factor. These data imply immunoreactivity loss driven by humidity and temperature results in structural distortion of epitopes rendering them unsuitable for antibody binding following epitope retrieval. Limitations of IHC biomarker analysis from stored tissue sections may be mitigated by cost-effective use of desiccant when appropriate. In some scenarios, complementary MS is a preferred approach for retrospective analyses of archival FFPE tissue collections.


Subject(s)
B7-H1 Antigen/analysis , Immunohistochemistry/methods , Mass Spectrometry/methods , Proteome/analysis , Proteomics/methods , B7-H1 Antigen/chemistry , Humans , Neoplasms/chemistry , Proteome/chemistry , Specimen Handling
7.
Clin Transl Sci ; 11(1): 46-53, 2018 01.
Article in English | MEDLINE | ID: mdl-28857461

ABSTRACT

Safety, tolerability, and pharmacology profiles of LY3127760, an EP4 antagonist, were explored in healthy subjects in a subject/investigator-blind, parallel-group, multiple-ascending dose study. Cohorts consisted of 13 patients randomized to LY3127760, celecoxib (400 mg), or placebo (9:2:2 ratio) for 28 days. LY3127760 was well tolerated; the most commonly observed adverse events were gastrointestinal, similar to celecoxib. LY3127760 increased release of ex vivo tumor necrosis factor alpha after lipopolysaccharide/prostaglandin E2 stimulation when compared with placebo, suggesting a dose-dependent blockade of the EP4 receptor. Compared with placebo, 24-h urinary excretion of prostaglandin E metabolite was modestly increased; prostacyclin metabolite was inhibited; and thromboxane A2 metabolite was unchanged. Effects on sodium and potassium excretion were similar to those of celecoxib. We conclude that LY3127760 demonstrated similar effects on prostacyclin synthesis and renal sodium retention as celecoxib. These data support exploration of LY3127760 at daily doses of 60 mg to 600 mg in phase II trials. This trial's registration number: NCT01968070.


Subject(s)
Anti-Inflammatory Agents, Non-Steroidal/pharmacology , Arthralgia/drug therapy , Celecoxib/pharmacology , Organic Chemicals/pharmacology , Osteoarthritis/drug therapy , Receptors, Prostaglandin E, EP4 Subtype/antagonists & inhibitors , Administration, Oral , Adult , Anti-Inflammatory Agents, Non-Steroidal/therapeutic use , Arthralgia/etiology , Celecoxib/therapeutic use , Double-Blind Method , Female , Healthy Volunteers , Humans , Male , Middle Aged , Organic Chemicals/chemistry , Osteoarthritis/complications , Placebos , Young Adult
10.
Bioanalysis ; 8(15): 1579-1595, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27314304

ABSTRACT

BACKGROUND: A thorough understanding of the biological role of oxyntomodulin (OXM) has been limited by the availability of sensitive and specific analytical tools for reliable in vivo characterization. Here, we utilized immunoaffinity capture coupled with high-resolution accurate mass LC-MS detection to quantify OXM and its primary catabolites. RESULTS: Quantification of intact OXM 1-37 in human and rat plasma occurred in pre- and post-prandial samples. Profiles for the major catabolites were observed allowing kinetic differences to be assessed between species. CONCLUSION: A validated assay in human and rat plasma was obtained for OXM 1-37 and its catabolites, 3-37 and 4-37. The value of full scan high-resolution accurate mass detection without selected reaction monitoring for low-abundance peptide quantification was also demonstrated.


Subject(s)
Chromatography, Affinity/methods , Mass Spectrometry/methods , Oxyntomodulin/blood , Animals , Humans , Limit of Detection , Male , Rats , Rats, Sprague-Dawley
11.
Bioanalysis ; 8(3): 163-7, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26795584

ABSTRACT

Crystal City VI Workshop on Bioanalytical Method Validation of Biomarkers, Renaissance Baltimore Harborplace Hotel, Baltimore, MD, USA, 28-29 September 2015 The Crystal City VI workshop was organized by the American Association of Pharmaceutical Scientists in association with the US FDA to continue discussion on the bioanalysis of biomarkers. An outcome of the Crystal City V workshop, convened following release of the draft FDA Guidance for Industry on Bioanalytical Methods Validation in 2013 was the need to have further discussion on biomarker methods. Biomarkers ultimately became the sole focal point for Crystal City VI, a meeting attended by approximately 200 people and composed of industry scientists and regulators from around the world. The meeting format included several panel discussions to maximize the opportunity for dialogue among participants. Following an initial session on the general topic of biomarker assays and intended use, more focused sessions were held on chromatographic (LC-MS) and ligand-binding assays. In addition to participation by the drug development community, significant representation was present from clinical testing laboratories. The experience of this latter group, collectively identified as practitioners of CLIA (Clinical Laboratory Improvement Amendments), helped shape the discussion and takeaways from the meeting. While the need to operate within the framework of the current BMV guidance was clearly acknowledged, a general understanding that biomarker methods validation cannot be adequately depicted by current PK-centric guidelines emerged as a consensus from the meeting. This report is not intended to constitute the official proceedings from Crystal City VI, which is expected to be published in early 2016.


Subject(s)
Chemistry Techniques, Analytical/methods , Education , United States Food and Drug Administration , Biomarkers/analysis , Biomarkers/metabolism , Chromatography , Humans , Ligands , Reproducibility of Results , United States
12.
Biochem J ; 473(5): 605-14, 2016 Mar 01.
Article in English | MEDLINE | ID: mdl-26635356

ABSTRACT

Fibroblast growth factor 21 (FGF21), a hormone implicated in the regulation of glucose homoeostasis, insulin sensitivity, lipid metabolism and body weight, is considered to be a promising therapeutic target for the treatment of metabolic disorders. Despite observations that FGF21 is rapidly proteolysed in circulation rending it potentially inactive, little is known regarding mechanisms by which FGF21 protein levels are regulated. We systematically investigated human FGF21 protein processing using mass spectrometry. In agreement with previous reports, circulating human FGF21 was found to be cleaved primarily after three proline residues at positions 2, 4 and 171. The extent of FGF21 processing was quantified in a small cohort of healthy human volunteers. Relative abundance of FGF21 proteins cleaved after Pro-2, Pro-4 and Pro-171 ranged from 16 to 30%, 10 to 25% and 10 to 34%, respectively. Dipeptidyl peptidase IV (DPP-IV) was found to be the primary protease responsible for N-terminal cleavages after residues Pro-2 and Pro-4. Importantly, fibroblast activation protein (FAP) was implicated as the protease responsible for C-terminal cleavage after Pro-171, rendering the protein inactive. The requirement of FAP for FGF21 proteolysis at the C-terminus was independently demonstrated by in vitro digestion, immunodepletion of FAP in human plasma, administration of an FAP-specific inhibitor and by human FGF21 protein processing patterns in FAP knockout mouse plasma. The discovery that FAP is responsible for FGF21 inactivation extends the FGF21 signalling pathway and may enable novel approaches to augment FGF21 actions for therapeutic applications.


Subject(s)
Fibroblasts , Proteolysis , Animals , Humans , Insulin Resistance , Lipid Metabolism , Protein Processing, Post-Translational
13.
Bioanalysis ; 7(19): 2461-75, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26470737

ABSTRACT

BACKGROUND: Human cerebrospinal fluid (CSF) is often acquired in Phase I clinical trials to assess the CNS penetration of new pharmacological agents and to search for biomarkers associated with PD effects. Robust methods for neurotransmitter metabolites in CSF have proven elusive, in part due to inadequate reversed phase LC retention. RESULTS: Benzoyl chloride derivatization was used to promote retention for LC-MS/MS for a panel of neurotransmitter metabolites while delivering a concise method for sample preparation. CONCLUSION: A validated assay in human CSF was obtained for 3,4-dihydroxyphenylacetic acid, homovanillic acid, 3,4-dihydroxyphenylglycol and 5-hydroxyindoleacetic acid. This method is differentiated from other LC-MS/MS methods by delivering results in line with full regulatory expectations.


Subject(s)
Benzoates/chemistry , Clinical Chemistry Tests/methods , Neurotransmitter Agents/cerebrospinal fluid , Tandem Mass Spectrometry , 3,4-Dihydroxyphenylacetic Acid/cerebrospinal fluid , 3,4-Dihydroxyphenylacetic Acid/standards , Animals , Chromatography, High Pressure Liquid/standards , Half-Life , Homovanillic Acid/cerebrospinal fluid , Homovanillic Acid/standards , Humans , Hydroxyindoleacetic Acid/cerebrospinal fluid , Hydroxyindoleacetic Acid/standards , Male , Methoxyhydroxyphenylglycol/analogs & derivatives , Methoxyhydroxyphenylglycol/cerebrospinal fluid , Methoxyhydroxyphenylglycol/standards , Neurotransmitter Agents/chemistry , Neurotransmitter Agents/metabolism , Quality Control , Rats , Rats, Sprague-Dawley , Tandem Mass Spectrometry/standards
14.
Mol Cell Proteomics ; 13(3): 907-17, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24443746

ABSTRACT

Adoption of targeted mass spectrometry (MS) approaches such as multiple reaction monitoring (MRM) to study biological and biomedical questions is well underway in the proteomics community. Successful application depends on the ability to generate reliable assays that uniquely and confidently identify target peptides in a sample. Unfortunately, there is a wide range of criteria being applied to say that an assay has been successfully developed. There is no consensus on what criteria are acceptable and little understanding of the impact of variable criteria on the quality of the results generated. Publications describing targeted MS assays for peptides frequently do not contain sufficient information for readers to establish confidence that the tests work as intended or to be able to apply the tests described in their own labs. Guidance must be developed so that targeted MS assays with established performance can be made widely distributed and applied by many labs worldwide. To begin to address the problems and their solutions, a workshop was held at the National Institutes of Health with representatives from the multiple communities developing and employing targeted MS assays. Participants discussed the analytical goals of their experiments and the experimental evidence needed to establish that the assays they develop work as intended and are achieving the required levels of performance. Using this "fit-for-purpose" approach, the group defined three tiers of assays distinguished by their performance and extent of analytical characterization. Computational and statistical tools useful for the analysis of targeted MS results were described. Participants also detailed the information that authors need to provide in their manuscripts to enable reviewers and readers to clearly understand what procedures were performed and to evaluate the reliability of the peptide or protein quantification measurements reported. This paper presents a summary of the meeting and recommendations.


Subject(s)
Biological Assay/methods , Biology , Mass Spectrometry/methods , Medicine , Peptides/metabolism , Animals , Guidelines as Topic , Humans , Isotope Labeling , Proteomics/standards , Reference Standards , Software
15.
PLoS One ; 8(11): e80292, 2013.
Article in English | MEDLINE | ID: mdl-24244672

ABSTRACT

A robust immunohistochemical (IHC) assay for VEGFR2 was developed to investigate its utility for patient tailoring in clinical trials. The sensitivity, specificity, and selectivity of the IHC assay were established by siRNA knockdown, immunoblotting, mass spectrometry, and pre-absorption experiments. Characterization of the assay included screening a panel of multiple human cancer tissues and an independent cohort of non-small cell lung carcinoma (NSCLC, n = 118) characterized by TTF-1, p63, CK5/6, and CK7 IHC. VEGFR2 immunoreactivity was interpreted qualitatively (VEGFR2 positive/negative) in blood vessels and by semi-quantitative evaluation using H-scores in tumor cells (0-300). Associations were determined among combinations of VEGFR2 expression in blood vessels and tumor cells, and clinico-pathologic characteristics (age, sex, race, histologic subtype, disease stage) and overall survival using Kaplan-Meier analyses and appropriate statistical models. VEGFR2 expression both in blood vessels and in tumor cells in carcinomas of the lung, cervix, larynx, breast, and others was demonstrated. In the validation cohort, 99/118 (83.9%) NSCLC tissues expressed VEGFR2 in the blood vessels and 46/118 (39.0%) showed high tumor cell positivity (H-score ≥10). Vascular and tumor cell expression were inversely correlated (p = 0.0175). High tumor cell expression of VEGFR2 was associated with a 3.7-fold reduction in median overall survival in lung squamous-cell carcinoma (SCC, n = 25, p = 0.0134). The inverse correlation between vascular and tumor cell expression of VEGFR2 and the adverse prognosis associated with high VEGFR2 expression in immunohistochemically characterized pulmonary SCC are new findings with potential therapeutic implications. The robustness of this novel IHC assay will support further evaluation of its utility for patient tailoring in clinical trials of antiangiogenic agents.


Subject(s)
Carcinoma, Squamous Cell/metabolism , Lung Neoplasms/metabolism , Vascular Endothelial Growth Factor Receptor-2/metabolism , Aged , Aged, 80 and over , Cell Line, Tumor , Female , Humans , In Vitro Techniques , Kaplan-Meier Estimate , Male , Middle Aged , Prognosis
16.
Bioanalysis ; 4(19): 2343-56, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23088461

ABSTRACT

BACKGROUND: Quantitation of biomarkers by LC-MS/MS is complicated by the presence of endogenous analytes. This challenge is most commonly overcome by calibration using an authentic standard spiked into a surrogate matrix devoid of the target analyte. A second approach involves use of a stable-isotope-labeled standard as a surrogate analyte to allow calibration in the actual biological matrix. For both methods, parallelism between calibration standards and the target analyte in biological matrix must be demonstrated in order to ensure accurate quantitation. RESULTS: In this communication, the surrogate matrix and surrogate analyte approaches are compared for the analysis of five amino acids in human plasma: alanine, valine, methionine, leucine and isoleucine. In addition, methodology based on standard addition is introduced, which enables a robust examination of parallelism in both surrogate analyte and surrogate matrix methods prior to formal validation. Results from additional assays are presented to introduce the standard-addition methodology and to highlight the strengths and weaknesses of each approach. CONCLUSION: For the analysis of amino acids in human plasma, comparable precision and accuracy were obtained by the surrogate matrix and surrogate analyte methods. Both assays were well within tolerances prescribed by regulatory guidance for validation of xenobiotic assays. When stable-isotope-labeled standards are readily available, the surrogate analyte approach allows for facile method development. By comparison, the surrogate matrix method requires greater up-front method development; however, this deficit is offset by the long-term advantage of simplified sample analysis.


Subject(s)
Amino Acids/blood , Chromatography, Liquid , Tandem Mass Spectrometry , Amino Acids/standards , Arachidonic Acids/blood , Arachidonic Acids/standards , Biomarkers/analysis , Chromatography, Liquid/standards , Endocannabinoids/blood , Endocannabinoids/standards , Glycerides/blood , Glycerides/standards , Humans , Isotope Labeling , Methylhistidines/blood , Polyunsaturated Alkamides/blood , Polyunsaturated Alkamides/standards , Reference Standards , Tandem Mass Spectrometry/standards
18.
Anal Biochem ; 430(2): 130-7, 2012 Nov 15.
Article in English | MEDLINE | ID: mdl-22922382

ABSTRACT

There is strong experimental evidence associating cathepsin S with the pathogenesis of atherosclerosis, with emerging data to support its role in diseases such as abdominal aortic aneurysm, obesity, and type 2 diabetes. To further our understanding of cathepsin S, we have developed a novel sandwich immunoassay to measure the mature form of cathepsin S in plasma (mean values from 12 healthy donors of 53±17ng/ml, range=39-102). We also developed a targeted liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay to measure in vitro cathepsin S activity to compare activity levels with the protein mass levels determined by enzyme-linked immunosorbent assay (ELISA). Interestingly, we observed that only 0.4 to 1.1% of circulating cathepsin S was enzymatically active. We subsequently demonstrated that the attenuated activity we observed resulted from binding between cathepsin S and its endogenous inhibitor cystatin C in plasma. These data were obtained through immunoprecipitation coupled with either Western blotting analysis or in-gel tryptic digestion and LC-MS/MS characterization of Coomassie-stained gel bands. Although many laboratories have explored the relationship between cathepsin S and cystatin C, this is the first study to demonstrate their association in human circulation, a finding that could prove to be important in furthering our understanding of cathepsin S biology.


Subject(s)
Cathepsins/blood , Chromatography, High Pressure Liquid , Enzyme-Linked Immunosorbent Assay , Tandem Mass Spectrometry , Antibodies, Monoclonal/immunology , Blotting, Western , Cathepsins/genetics , Cathepsins/metabolism , Cystatin C/genetics , Cystatin C/metabolism , Humans , Immunoprecipitation , Protein Binding , Recombinant Proteins/genetics , Recombinant Proteins/metabolism
19.
Bioanalysis ; 4(3): 241-8, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22303828

ABSTRACT

BACKGROUND: Accurate measurement of a total protein target (free plus bound) is essential to optimize dose selection for monoclonal antibody drugs. Herein, we describe a novel sandwich immunoassay format in which the biotherapeutic antibody itself serves as the primary detection antibody. A signal is then generated through the addition of a labeled secondary antibody that recognizes the biotherapeutic antibody. The secondary antibody is conjugated with ruthenium to facilitate electrochemiluminescent analysis. RESULTS: Data are presented from the analysis of two protein biomarkers having disparate size and structure; a 4.5 kDa peptide and a 60 kDa protein. In both cases, validated, highly specific assays were developed and shown to be tolerant to elevated levels of the therapeutic monoclonal antibody in question. CONCLUSION: Our novel format allows drug-tolerant measurement of soluble protein biomarkers targeted by monoclonal antibodies when only two independent epitopes for antibody binding are available and one is recognized by the therapeutic antibody.


Subject(s)
Immunoassay , Peptides/blood , Pharmaceutical Preparations/chemistry , Proteins/analysis , Animals , Antibodies/chemistry , Antibodies/immunology , Antibodies, Monoclonal/immunology , Biomarkers/blood , Haplorhini , Humans , Luminescent Measurements , Peptides/immunology , Proteins/immunology , Ruthenium/chemistry
20.
Psychopharmacology (Berl) ; 219(4): 959-70, 2012 Feb.
Article in English | MEDLINE | ID: mdl-21847569

ABSTRACT

RATIONALE: Accumulating evidence suggests that the primary symptoms of schizophrenia may be associated with altered central glutamate transmission. LY2140023 monohydrate is the methionine prodrug of the selective mGlu(2/3) receptor agonist LY404039 and is currently being assessed for the treatment of schizophrenia. OBJECTIVE: The objective of this study was to evaluate the central pharmacological activity of LY2140023 monohydrate in preclinical and clinical studies. METHODS: Effects on neurotransmitter/metabolite concentrations were assessed in male rats following single oral doses of LY2140023 monohydrate (microdiasylates from the prefrontal cortex), single intraperitoneal injection of LY404039 [cerebrospinal fluid (CSF)], or LY2140023 monohydrate dosed once daily for 7 days (CSF). A clinical study in 16 healthy subjects assessed the effects of LY2140023 monohydrate 40 mg orally twice daily for 14 days in lumbar CSF. RESULTS: Rat studies: Acute dosing with LY2140023 monohydrate resulted in significant dose-dependent increases in extracellular concentrations of dihydroxyphenylacetic acid (DOPAC) and homovanillic acid (HVA), but not 5-hydroxyindoleacetic acid (5-HIAA), in the prefrontal cortex. LY2140023 monohydrate dosing for 7 days elevated the concentrations of HVA in CSF, while acutely dosed LY404039 increased the concentrations of DOPAC, HVA, and methoxy-hydroxyphenylglycol (MHPG), but not 5-HIAA. Clinical study: Significant increases were seen for DOPAC, HVA, 5-HIAA, and MHPG in the CSF of subjects receiving LY2140023 monohydrate, but not placebo. CONCLUSIONS: LY2140023 monohydrate and/or LY404039 dosing potently affected dopamine turnover and also significantly affected serotonin turnover in the human and rat central nervous systems. The measurement of biogenic amine metabolites such as DOPAC and HVA may serve as useful biomarkers of LY2140023 monohydrate and/or LY404039 central pharmacodynamic activity.


Subject(s)
Amino Acids/pharmacology , Bridged Bicyclo Compounds, Heterocyclic/pharmacology , Cyclic S-Oxides/pharmacology , Receptors, Metabotropic Glutamate/agonists , 3,4-Dihydroxyphenylacetic Acid/cerebrospinal fluid , 3,4-Dihydroxyphenylacetic Acid/metabolism , Adult , Amino Acids/administration & dosage , Animals , Biomarkers, Pharmacological/metabolism , Bridged Bicyclo Compounds, Heterocyclic/administration & dosage , Cyclic S-Oxides/administration & dosage , Dopamine/metabolism , Dose-Response Relationship, Drug , Homovanillic Acid/cerebrospinal fluid , Homovanillic Acid/metabolism , Humans , Injections, Intraperitoneal , Male , Microdialysis , Prodrugs , Rats , Rats, Sprague-Dawley , Serotonin/metabolism , Single-Blind Method , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...