Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
Ultraschall Med ; 35(1): 33-7, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24327473

ABSTRACT

INTRODUCTION: The potential of sonography in the examination of lung tissue is extremely limited by the air-filled alveoles of the lung. Only in special circumstances like pleural adhesion lesions, atelectasis or pneumonia can lung tissue be visualized by B-mode sonography. Real-time elastography was primarily applied to detect and visualize pulmonary lesions. METHODS AND PATIENTS: 8 patients with a total of 18 histologically proven metastases of the lung were included. All pulmonary lesions were detected by computed tomography. Sonographic examination was performed with a 7.5 MHz linear transducer (Acuson Antares premium edition, Siemens, Erlangen, Germany), including B-mode and real-time elastography (RTE). The mean distance between pleura and the lesions ranged from 0 to 2.5 cm. Two lesions were located in the upper right lobe, eleven lesions in the lower right and five in the lower left lobe. RESULTS: RTE was able to detect and visualize all 18 pulmonary lesions in contrast to B-mode. The size and distance of the lesions from the pleura correlated with the CT findings. CONCLUSION: In contrast to B-mode sonography, RTE is able to detect and visualize peripheral, non-pleural adherent pulmonary lesions.


Subject(s)
Breast Neoplasms/diagnostic imaging , Elasticity Imaging Techniques/methods , Leiomyosarcoma/diagnostic imaging , Leiomyosarcoma/secondary , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/secondary , Ovarian Neoplasms/diagnostic imaging , Uterine Neoplasms/diagnostic imaging , Aged , Breast Neoplasms/pathology , Elasticity Imaging Techniques/instrumentation , Feasibility Studies , Female , Humans , Image Enhancement/instrumentation , Image Enhancement/methods , Image Interpretation, Computer-Assisted/instrumentation , Image Interpretation, Computer-Assisted/methods , Leiomyosarcoma/pathology , Lung/diagnostic imaging , Lung/pathology , Lung Neoplasms/pathology , Middle Aged , Ovarian Neoplasms/pathology , Sensitivity and Specificity , Tomography, X-Ray Computed , Transducers , Tumor Burden , Uterine Neoplasms/pathology
2.
AJNR Am J Neuroradiol ; 33(4): E55-60, 2012 Apr.
Article in English | MEDLINE | ID: mdl-21454412

ABSTRACT

BACKGROUND AND PURPOSE: Computed tomography is an essential modality for imaging of the temporal bone. Newest generation scanners allow the coverage of large examination volumes with a single gantry rotation. The objective of this study was to compare a 128-section SST (1 single rotation of the x-ray tube) with conventional spiral MSCT (ultra-high-resolution mode) for imaging of the temporal bone. MATERIALS AND METHODS: Fifty-four temporal bones in 27 patients were scanned with both a conventional MSCT and 128-section SST. After blinding and randomization of both examinations, 2 observers assessed the visualization of 38 anatomic structures (eg, various segments of the facial nerve canal, mallear ligaments) by using multiplanar reconstructions in the axial and coronal planes. The differences in evaluation scores obtained for the 2 techniques were analyzed by using a Wilcoxon signed rank test, with a P value of < .05 considered significant. For both methods, imaging time and radiation exposure were noted. RESULTS: Overall visualization of anatomic structures did not differ significantly between the 2 techniques (P > .05). When we compared the anatomic structures separately, there was better visualization of the lateral mallear ligament with MSCT, whereas the cochlear septa were ranked higher with SST (P < .05). Imaging time and average DLP for MSCT were 12.3 seconds and 306 mGy cm, respectively; for SST, values they were 1 second and 64 mGy cm, respectively (ie, a dose reduction of 79%). CONCLUSIONS: For imaging of the temporal bone with adequate diagnostic quality, 128-section SST can be used. The main advantages over MSCT are the dramatic reductions of imaging time and radiation exposure, which are particularly important when scanning uncooperative patients or children.


Subject(s)
Temporal Bone/diagnostic imaging , Tomography, X-Ray Computed/methods , Adult , Aged , Female , Humans , Male , Middle Aged , Observer Variation , Reproducibility of Results , Sensitivity and Specificity
3.
Eur J Surg Oncol ; 38(1): 44-51, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22032911

ABSTRACT

BACKGROUND: Re-operations after breast conserving surgery (BCS) are necessary, when specimen margins are not free of breast cancer cells. This study explored the accuracy of preoperative tumour size assessment and its influence on the rate of re-excisions and mastectomies. METHODS: The study included 1591 patients with invasive breast cancer, who were planned for BCS. Patient, staging and tumor characteristics were evaluated concerning their influence on re-excision and mastectomy rates. Patient and tumor characteristics comprised histopathological tumour size, HER2 status, multifocality, in situ component, grading (G), nodal status and hormone receptor (HR) status. Staging characteristics included deviation from pathological tumour size as measured by clinical examination, sonography and mammography. RESULTS: In 1316 patients (83%) sufficient treatment was possible with one operation. 275 patients (17%) had to undergo at least one further surgery as a result of positive specimen margins. In 138 patients (9%) mastectomy was ultimately necessary. In patients with a positive HER2 status, a larger tumour size, underestimation by ultrasound, an in situ component and multifocality, the risk for a re-operation was about doubled. Tumour size deviation in the mammogram or the clinical tumour size assessment did not have significant influence to the re-excision rates. CONCLUSION: Tumour size and accurate presurgical assessment of the tumour size itself are independent predictors for the need of a second surgery or even a mastectomy in patients for whom a primary BCS was planned.


Subject(s)
Breast Neoplasms/pathology , Breast Neoplasms/surgery , Mammography , Mastectomy, Segmental , Neoplasm, Residual/surgery , Adult , Aged , Aged, 80 and over , Biomarkers, Tumor/blood , Breast Neoplasms/diagnostic imaging , Cohort Studies , Female , Humans , Mastectomy, Modified Radical , Middle Aged , Neoplasm Grading , Neoplasm Staging , Predictive Value of Tests , Preoperative Period , Reoperation , Risk Assessment , Ultrasonography, Mammary
4.
Geburtshilfe Frauenheilkd ; 72(5): 408-411, 2012 May.
Article in English | MEDLINE | ID: mdl-25298545

ABSTRACT

Purpose: Experimental study of a new system for digital 2D and 3D full-field mammography (FFDM) using a high resolution detector based on two shifts of a-Se. Material and Methods: Images were acquired using the new FFDM system Amulet® (FujiFilm, Tokio, Japan), an a-Se detector (receptor 24 × 30 cm2, pixel size 50 µm, memory depth 12 bit, spatial resolution 10 lp/mm, DQE > 0.50). Integrated in the detector is a new method for data transfer, based on optical switch technology. The object of investigation was the Wisconsin Mammographic Random Phantom, Model 152A (Radiation Measurement Inc., Middleton, WI, USA) and the same parameters and exposure data (Tungsten, 100 mAs, 30 kV) were consistently used. We acquired 3 different pairs of images in the c-c and ml planes (2D) and in the c-c and c-c planes with an angle of 4 degrees (3D). Five radiologists experienced in mammography (experience ranging from 3 months to more than 5 years) analyzed the images (monitoring) which had been randomly encoded (random generator) with regard to the recognition of details such as specks of aluminum oxide (200-740 µm), nylon fibers (0.4-1.6 mm) and round lesions/masses (diameters 5-14 mm), using special linear glasses for 3D visualization, and compared the results. Results: A total of 225 correct positive decisions could be detected: we found 222 (98.7 %) correct positive results for 2D and 3D visualization in each case. Conclusion: The results of this phantom study showed the same detection rates for both 2D and 3D imaging using full field digital mammography. Our results must be confirmed in further clinical trials.

5.
Ultraschall Med ; 32 Suppl 2: E75-9, 2011 Dec.
Article in English | MEDLINE | ID: mdl-22194044

ABSTRACT

PURPOSE: Phyllodes tumors (PT) are a rare entity accounting for less than 1 % of all breast lesions. They have a malignancy rate of 25-30%. Differentiation from benign fibroadenomas is difficult using ultrasound, mammogram and MRI. The elastic characteristics of both tumors were examined using real-time elastography (RTE) to find specific patterns that make differentiation possible. MATERIALS AND METHODS: From February 2007 to May 2009, a total of 620 women were examined by RTE. Histological diagnosis was achieved using core needle biopsy. 123 of the lesions were fibroadenomas, 8 were phyllodes tumors. All patients underwent mammography and ultrasound followed by RTE. Sonography was performed by Acuson Antares, Premium Edition® (Siemens, Erlangen, Germany) with a 7 and 10 MHz transducer. RESULTS: All phyllodes tumors had a similar elastic pattern with an elastic center and inelastic outer limits, referred to as the "ring sign". It was found in 5% of all fibroadenomas. CONCLUSION: RTE provides a specific elastic pattern, which is sufficient for differentiating between a fibroadenoma and a phyllodes tumor. Therefore, the detection of the most suspicious lesion in women with the coexistence of multiple fibroadenomas and phyllodes tumors seems easier.


Subject(s)
Breast Neoplasms/diagnostic imaging , Elasticity Imaging Techniques , Fibroadenoma/diagnostic imaging , Image Interpretation, Computer-Assisted , Phyllodes Tumor/diagnostic imaging , Ultrasonography, Mammary , Adult , Biopsy, Needle , Breast/pathology , Breast Neoplasms/pathology , Diagnosis, Differential , Female , Fibroadenoma/pathology , Follow-Up Studies , Humans , Magnetic Resonance Imaging , Middle Aged , Phyllodes Tumor/pathology , Sensitivity and Specificity
6.
Ultraschall Med ; 32(1): 67-73, 2011 Feb.
Article in English | MEDLINE | ID: mdl-21165816

ABSTRACT

PURPOSE: Elastography is a new ultrasonographic method that has been examined as a diagnostic tool for breast lesions. This study was intended to create and define new elastographic criteria allowing assessment of whether breast lesions are malignant or benign. MATERIALS AND METHODS: 217 patients with a total of 245 breast lesions of unknown malignancy underwent ultrasound examination. The new eSie Touch Elasticity Imaging technology (Siemens, Erlangen, Germany) was used with a 10-MHz linear transducer (Acuson Antares). Lesions were examined using B-mode and real-time elastography (RTE). Each lesion was histologically assessed by core biopsy. Five RTE characteristics were examined: elasticity proportion (EP), different location on RTE in comparison with B-mode (MV), different contrast patterns (SOS), dorsal lesion limitation visibility and different size on RTE in comparison with B-mode. RESULTS: 54 malignant lesions (54 %) appeared inelastic, in contrast to the benign control group (34.5 %; P = 0.001). A completely elastic pattern was visible in 10 malignant (10 %) and 39 benign lesions (26.9 %). MV was identified in 23 cases, with 22 of the lesions being malignant and one benign. The SOS was negative in 89 malignant lesions (89 %) and positive in 100 benign lesions. The dorsal lesion limitation was visible on RTE without B-mode in 88 malignant lesions (88 %) and 27 benign lesions (18.6 %). The size was assessed as larger in 45 malignant lesions (45 %) and seven benign lesions (4.8 %). CONCLUSION: SOS and a larger tumor size on RTE are specific characteristics of malignant breast lesions. EP, MV and distal mass border are further helpful signs to assess the malignancy of tumors.


Subject(s)
Breast Neoplasms/diagnostic imaging , Elasticity Imaging Techniques/methods , Image Enhancement/methods , Image Processing, Computer-Assisted/methods , Ultrasonography, Mammary/methods , Adolescent , Adult , Aged , Aged, 80 and over , Carcinoma, Ductal, Breast/diagnostic imaging , Elasticity , Female , Fibroadenoma/diagnostic imaging , Humans , Middle Aged , Multivariate Analysis , Papilloma, Intraductal/diagnostic imaging , Prospective Studies , Sensitivity and Specificity , Young Adult
7.
Geburtshilfe Frauenheilkd ; 71(12): 1080-1084, 2011 Dec.
Article in English | MEDLINE | ID: mdl-25253902

ABSTRACT

Aim: A prospective clinical study was done to see whether it is possible to reduce the rate of re-excisions using digital breast tomosynthesis (DBT) compared commercial FFDM. Material and Method: Between 1/2011 and 5/2011 we diagnosed an invasive breast cancer (BI-RADS 5) in 100 patients. After histological verification we performed breast-conserving therapy with intraoperative imaging using one of 2 different systems: 1. Tomosynthesis (Siemens, Erlangen, Germany), amorphous selenium, Tungsten source, focus 0.1 mm, resolution 85 µm, pixel pitch, 8 l/mm, range: 50°, 25 projections, time for scanning > 20 s, geometry: same scanning scope, reconstruction: filtered back projection; or 2. Inspiration™ (Siemens, Erlangen, Germany), amorphous selenium, tungsten source, focus 0.1 mm, resolution 85 µm, pixel pitch, 8 l/mm as the standard. The 100 radiograms obtained with both systems were prospectively shown on a monitor to 3 radiologists. Results: Out of a total of 100 patients with histologically proven breast cancer (BI-RADS 6) no re-excision was necessary in 78 patients. A retrospective analysis (n = 22) demonstrated an increase in sensitivity of tomosynthesis compared to the Inspiration™ at a magnification of 1.0 : 1.0 of 8 % (p < 0.05), i.e., in 8 patients re-excision would not have been necessary with tomosynthesis. Conclusion: Tomosynthesis has a significant higher sensitivity (p < 0.05) compared with a commercial FFDM system. Studies with higher numbers of patients will be necessary to evaluate this method.

8.
Geburtshilfe Frauenheilkd ; 71(12): 1056-1066, 2011 Dec.
Article in English | MEDLINE | ID: mdl-25253900

ABSTRACT

The information available about breast cancer risk factors has increased dramatically during the last 10 years. In particular, studies of low-penetrance genes and mammographic density have improved our understanding of breast cancer risk. In addition, initial steps have been taken in investigating interactions between genes and environmental factors. This review concerns with actual data on this topic. Several genome-wide association studies (GWASs) with a case-control design, as well as large-scale validation studies, have identified and validated more than a dozen single nucleotide polymorphisms (SNPs) associated with breast cancer risk. They are located not only in or close to genes known to be involved in cancer pathogenesis, but also in genes not previously associated with breast cancer pathogenesis, or may even not be related to any genes. SNPs have also been identified that alter the lifetime risk in BRCA mutation carriers. With regard to nongenetic risk factors, studies of postmenopausal hormone replacement therapy (HRT) have revealed important information on how to weigh up the risks and benefits of HRT. Mammographic density (MD) has become an accepted and important breast cancer risk factor. Lifestyle and nutritional considerations have become an integral part of most studies of breast cancer risk, and some improvements have been made in this field as well. More than 10 years after the publication of the first breast cancer prevention studies with tamoxifen, other substances such as raloxifene and aromatase inhibitors have been investigated and have also been shown to have preventive potential. Finally, mammographic screening systems have been implemented in most Western countries during the last decade. These may be developed further by including more individualized methods of predicting the patient's breast cancer risk.

9.
Radiologe ; 51(2): 126-9, 2011 Feb.
Article in German | MEDLINE | ID: mdl-21069511

ABSTRACT

PURPOSE: The aim of this retrospective clinical study was to compare the diagnostic accuracy of the novel 50 µm FFDM (full-field digital mammography) system (DR) with an established 70 µm system (DR) in the differential diagnosis between benign and malignant clusters of microcalcification (n=50) (BI-RADS™ classification 4/5) and to assess the possible incremental value of the 50 µm pixel-pitch on specificity. MATERIAL AND METHODS: From March 2009 to September 2009, 50 patients underwent full-field digital mammography (FFDM) (detector resolution 70 µm) (Novation, Siemens, Erlangen, Germany). As there were suspicious signs of microcalcification classified with BI-RADS™ 4/5 after diagnosis and preoperative wire localization, control images were made with the new FFDM system (detector: resolution 50 µm) (Amulet, Fujifilm, Tokyo, Japan) with the same exposure parameters. The diagnosis was determined after the operation by five radiologists with different experience in digital mammography from randomly distributed mediolateral views (monitor reading) whose results were correlated with the final histology of all lesions. RESULTS: Histopathology revealed 19 benign and 31 malignant lesions in 50 patients after open biopsy. The results of the five readers showed a higher sensitivity of the new FFDM system (80.0%) in the ability to recognize malignant microcalcification in comparison to the established system (74.8%). The specificity (75.8 versus 71.6%) was slightly higher for the new system but these results were not statistically significant (p<0.001). Considering the diagnostic accuracy, the new system (detector: resolution 50 µm) was also slightly superior to the well-known system (detector: resolution 70 µm) (80.1% versus 76.4%). CONCLUSIONS: Our study has shown that the new full-field digital mammography system using the novel detector compared with the already established FFDM system with respect to the assessment of microcalcification is at least equivalent.


Subject(s)
Breast Diseases/diagnostic imaging , Calcinosis/diagnostic imaging , Mammography/instrumentation , Radiographic Image Enhancement/instrumentation , Radiographic Image Enhancement/methods , Transducers , Adolescent , Adult , Aged , Equipment Design , Equipment Failure Analysis , Humans , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Young Adult
10.
Radiologe ; 51(2): 130-4, 2011 Feb.
Article in German | MEDLINE | ID: mdl-21069512

ABSTRACT

PURPOSE: The article describes an experimental phantom study of a system for digital full field mammography with a new digital detector with a double plate of pure selenium. MATERIALS AND METHODS: The experiments were carried out with the new full field digital mammography system Amulet from FujiFilm. This system has a new detector (18×24 cm(2)) on the basis of highly purified amorphous selenium (a-Se) with a pixel size of 50 µm. The x-rays are converted into electric signals in the first plate which are read into the second plate with the help of an optical switch and demonstrated in the form of an image. In this way a better pixel size/volume and signal-to-noise ratio should be achieved. The object of the investigation was the Wisconsin Mammographic Random Phantom, Model 152 A (Technical Performance Mo/Mo, 28 kV, 100 mAs). Five investigators with different experiences in mammography each received three images on a monitor with different random positions of the simulated lesions in the phantom for assessment. The detection rates were compared under the same conditions with the results of two other full field digital mammography systems. RESULTS: The median detection rate for all images and investigators for the new doubled plated a-Se detector with optical switch was 98.7%. For both other systems with a-Si or and a-Se detectors the detection rate was 89.8% or 97.3%, respectively. There were no significant differences in the detection rate of the simulated breast lesions for all three systems considering the interobserver and intraobserver variation. CONCLUSION: The first phantom study for the detection of simulated breast lesions with the new full field digital mammography system Amulet demonstrates equivalent results with the other systems used in the clinical routine. The trend towards superiority of the new system has to be confirmed in further clinical studies.


Subject(s)
Breast Neoplasms/diagnostic imaging , Mammography/instrumentation , Radiographic Image Enhancement/instrumentation , Selenium , Transducers , Equipment Design , Equipment Failure Analysis , Female , Humans , Observer Variation , Phantoms, Imaging , Pilot Projects , Reproducibility of Results , Sensitivity and Specificity
14.
Radiologe ; 49(9): 868-71, 2009 Sep.
Article in German | MEDLINE | ID: mdl-19148618

ABSTRACT

Diagnostic investigations of mammary glands, which are routinely undertaken prior to a planned liver transplantation, can place high demands on the radiologist. The article describes a case of known Ehlers-Danlos syndrome, where it was essential that the radiologist was sufficiently informed over the past history, possible previously made images and typical presentation forms of microcalcification for corresponding findings from the breast diagnostics.


Subject(s)
Breast Diseases/diagnostic imaging , Calcinosis/diagnostic imaging , Ehlers-Danlos Syndrome/diagnostic imaging , Mammography/methods , Diagnosis, Differential , Female , Humans , Middle Aged
16.
Rofo ; 179(8): 826-31, 2007 Aug.
Article in German | MEDLINE | ID: mdl-17577870

ABSTRACT

PURPOSE: To investigate the tolerance of MR examinations in children and adolescents performed in a 1.5 Tesla MR scanner with an expanded bore diameter. METHOD AND MATERIALS: 163 patients, ages 4 to 25, underwent MR examinations in a 1.5 Tesla MR scanner with an open design (MAGNETOM Espree, Siemens, Erlangen, Germany), characterized by a compact length of 125 cm and an expanded 70 cm bore diameter. MR imaging of the brain was carried out in most cases (78.5 %), followed by examinations of the spinal canal (9.8 %), the extremities (9.2 %) and the neck (2.5 %). The patients were divided into four age groups and the success rate, motion artifacts and diagnostic quality of the MR examinations were assessed using a 3-grade scale. RESULTS: In 119 of 163 patients (73.0 %), MR examination was possible without any motion artifacts. With respect to the different age groups, 41.7 % of the 4 - 7-year-old children, 67.6 % of the 8 - 10-year-old children, 84.1 % of the 11 - 16-year-old children and 95.8 % of the patients older than 17 showed tolerance grade I without motion artifacts and excellent diagnostic image quality. In 39 of 163 children (23.9 %), the MR images showed moderate motion artifacts but had sufficient diagnostic quality. With regard to the different age groups, 52.8 % of the 4 - 7-year-old children, 26.5 % of the 8 - 10-year-old children, 15.9 % of the 11 - 16-year-old children and none of the patients older than 17 showed tolerance grade II with moderate motion artifacts and sufficient diagnostic image quality. In only 4 of 124 children < 10 years old and 1 child > 10 years old, the MR examination was not feasible and had to be repeated under sedation. CONCLUSION: Pediatric MR imaging using a 1.5 Tesla MR scanner with an open design can be conducted in children and adolescents with excellent acceptance. The failure rate of 3.0 % of cases for pediatric MR imaging is comparable to that of a conventional low-field open MR scanner.


Subject(s)
Artifacts , Image Enhancement/instrumentation , Image Enhancement/methods , Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging/methods , Patient Acceptance of Health Care , Adolescent , Adult , Child , Child, Preschool , Equipment Design , Equipment Failure Analysis , Female , Germany , Humans , Male , Reproducibility of Results , Sensitivity and Specificity
17.
Rofo ; 179(5): 492-6, 2007 May.
Article in German | MEDLINE | ID: mdl-17436183

ABSTRACT

PURPOSE: Evaluation of the diagnostic value of breast specimen imaging with a digital mammographic system using a detector system with changeable pixel size compared to standard mode imaging in different monitor display modes. MATERIALS AND METHODS: Using the digital mammographic system SenoScan (Fischer Imaging, Denver, USA), 50 diagnostic breast specimens with microcalcifications were visualized in both standard mode (pixel size 54 microm) and high resolution mode (pixel size 27 microm). The resulting radiographs were displayed 1:1 on a monitor. Standard mode images (pixel size 54 microm) were additionally displayed in a 2:1 mode. A total of 5 readers with different mammographic experience analyzed the type of the microcalcifications on the basis of the different display modes. The images were presented randomly. The findings were subsequently compared to the histology. RESULTS: The high resolution mode yielded slightly but not significantly better results than the standard mode on average for all 5 readers. Compared to a sensitivity of 80 % and a specificity of 72 % (PPV = 74 %, NPV = 78 %) in the standard mode, the high resolution mode provided a sensitivity of 86 % and a specificity of 74 % (PPV = 77 %, NPV = 83 %). The standard mode images on a 2:1 monitor display yielded 84 % and 74 % (PPV = 76 %, NPV = 82 %). CONCLUSION: The high resolution mode did not significantly increase the sensitivity and specificity of the microcalcification reading. A similar improvement was achieved by the 2:1 display mode, i. e. digital monitor zooming. For the clinical situation this means that there is no diagnostic advantage from using a high resolution target view with this mammographic system.


Subject(s)
Breast Neoplasms/diagnostic imaging , Calcinosis/diagnostic imaging , Mammography/methods , Radiographic Image Enhancement/methods , Humans , Male , Phantoms, Imaging , Radiation Dosage
18.
Strahlenther Onkol ; 177(11): 604-10, 2001 Nov.
Article in German | MEDLINE | ID: mdl-11757183

ABSTRACT

PURPOSE: In early stage Dupuytren's contracture radiotherapy was applied to prevent disease progression. Long-term results and late toxicity of this treatment were evaluated in a retrospective analysis. PATIENTS AND METHODS: Between 1982 and 1994, 99 patients (176 hands) received orthovoltage radiotherapy, which consisted of two courses with 5 x 3 Gy (total dose: 30 Gy, daily fractionated; 120 kV, 4 mm Al), separated by a 6 to 8-week pause. The Dupuytren's contracture was staged according to the classification of Tubiana et al. The long-term outcome was analyzed at last follow-up between July and November 1999. The median follow-up was 10 years (range 7-18 years). Late toxicity was assessed using the LENT-SOMA criteria. RESULTS: In Stage N 84% and Stage N/I 67% of cases remained stable. 65% of the cases in Stage I and 83% in Stage II showed progressive nodules and cords. In case of progression we saw no complications after a second radiotherapy or salvage operation. CONCLUSION: Radiotherapy effectively prevents disease progression for early stage Dupuytren's contracture (Stage N, N/I). Moreover, in case of disease progression despite radiotherapy salvage surgery is still feasible.


Subject(s)
Dupuytren Contracture/radiotherapy , Adolescent , Adult , Aged , Disease Progression , Dose Fractionation, Radiation , Dupuytren Contracture/diagnosis , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...