Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
J Nucl Med Technol ; 2023 Nov 14.
Article in English | MEDLINE | ID: mdl-37963782

ABSTRACT

A new SPECT/CT protocol for parathyroid imaging detailing fewer image-angle acquisitions (fewer-angle SPECT/CT [FASpecT/CT]) was evaluated for identification of parathyroid adenoma. The motivation for validating this protocol was to be able to use it in the future to decrease patient imaging time in our clinic. Methods: This was a retrospective review of existing data performed as a simulated case control study evaluating 50 parathyroid SPECT/CT scans acquired using the standard 60-stop protocol and the tested 15-stop FASpecT protocol acquired using angular sampling software. Agreement on the final interpretations between imaging methods was evaluated using the McNemar test and the Cohen κ. Interrater reliability among the 3 readers was described for each method using the Fleiss κ interpreted as in the strength-of-agreement guidelines by Landis and Koch. Results: Of the 50 evaluated images, 45 (90%) had concordant final image interpretations between imaging methods. The sensitivity of FASpecT/CT relative to SPECT/CT was 17 of 19 (89.5%; 95% CI, 66.9%-98.7%), and the specificity was 28 of 31 (90.3%; 95% CI, 74.2%-98.0%). Additionally, there was statistically significant substantial agreement between protocols and among readers for each protocol. Conclusion: Adequate diagnostic-quality SPECT/CT images can be acquired using significantly fewer imaging stops given advances in camera quality and processing algorithms such as iterative reconstruction.

2.
World J Nucl Med ; 20(3): 247-252, 2021.
Article in English | MEDLINE | ID: mdl-34703392

ABSTRACT

Cadmium Zinc Telluride (CZT) crystal-based myocardial perfusion imaging (MPI) cameras have increased count sensitivity compared to Anger cameras and can be used to lower either the injected activity or the image acquisition time. Institutions adopting CZT cameras need to decide whether to lower the injected activity or imaging time or attempt to lower both with a compromise. The aim of our study was to compare the scan time required to obtain similar count images using high activity protocol (HAP) versus low activity protocol (LAP) stratified by body mass index (BMI) and assess the impact on effective dose and our clinic workflow. Using a CZT camera, a cohort of 100 consecutive clinical patients imaged with LAP rest-stress MPI with approximately 185 MBq and 555 MBq activity was retrospectively compared to a similar cohort of 100 consecutive clinical patients imaged with HAP rest-stress MPI using approximately 370 MBq and 1110 MBq. Administered activity and BMI both had a statistically significant effect on scan time and radiation effective dose. LAP scans took an average of 9 min longer than HAP scans overall, P < 0.0001 and larger BMIs took longer than smaller BMIs, P < 0.0001. In addition, scan times were longer in men than women, P = 0.007. Effective dose was inversely proportional to BMI with an overall decrease of approximately 50% comparing LAP to HAP. For the same CZT camera, the LAP increased scan time while lowering the radiation effective dose when compared to HAP. The increase in scan time increased proportionally to BMI. The effective dose was inversely proportional to BMI. This increase in time did not have a significant impact on our local workflow, but its implications should be considered in the setting of LAP implementation, especially in obese or high patient volume practices.

3.
J Nucl Med Technol ; 49(1): 39-43, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33361187

ABSTRACT

A new protocol for rapid SPECT/CT blood pool imaging consisting of fewer image-angle acquisitions (fewer-angle SPECT/CT, or FASpecT/CT) was evaluated for localization of focal sites of soft-tissue inflammation, infection, and osteomyelitis. Methods: Immediately after dynamic flow and standard planar blood pool imaging with 99mTc-methylene diphosphonate, FASpecT/CT was performed with a dual-head γ-camera consisting of 6 steps over 360°, 12 total images with 30° of separation between angles, and 30 s per image, requiring a total imaging time of approximately 3 min. Images were reconstructed using iterative ordered-subset expectation maximization. Before use in a patient-care setting, various FASpecT/CT acquisition protocols were modeled using a phantom to determine the minimum number of stops and the stop duration required to produce a reliable image. Results: FASpecT/CT images provided excellent 3-dimensional localization of spine osteomyelitis, soft-tissue infection of the foot, and tendonitis of the hand and foot using a 3-min image acquisition time. The FASpecT/CT acquisition protocol required 1.3-3.5 min, including camera movement time. This was a reduction of 72%-90% from the time required for the standard 60-angle, 20-s SPECT/CT acquisition. Conclusion: The ability of FASpecT/CT blood pool images to help localize focal sites of hyperemia and inflammation can increase exam sensitivity and specificity. Additionally, using a FASpecT/CT protocol decreases imaging time by up to 90%.


Subject(s)
Radiopharmaceuticals , Tomography, Emission-Computed, Single-Photon , Humans , Inflammation/diagnostic imaging , Sensitivity and Specificity , Single Photon Emission Computed Tomography Computed Tomography
4.
Mil Med ; 186(1-2): e234-e240, 2021 Jan 30.
Article in English | MEDLINE | ID: mdl-33007060

ABSTRACT

INTRODUCTION: The purpose of this study is to introduce a virtual radiology rotation curriculum that is being used to safely maintain medical student and intern education and engagement with the Department of Radiology at Walter Reed National Military Medical Center during coronavirus disease 2019 (COVID-19) mitigation. MATERIALS AND METHODS: The curriculum is designed as a 4-week block with each week representing one of the four highest yield radiology subspecialties for medical students; neuroradiology, thoracic radiology, body radiology, and musculoskeletal radiology. A subspecialist radiologist from each section was identified as a primary mentor and tasked with designing a daily schedule for medical students and interns. The first 2 months of virtual rotators were surveyed to assess the effectiveness of the course. RESULTS: Thirty-five of 41 rotators responded to the survey, a response rate of 85%. Thirty-one of 35 (89%) of the rotators gave this virtual elective rotation a positive rating, with 16 trainees scoring the course as 4 out of 5 and 15 trainees selecting 5 out of 5. Four respondents selected 3 out of 5. Five out of 5 respondents who had experienced an in-person radiology elective rotation before this virtual rotation rated the virtual elective as more educational than the in-person rotation. We found the 4-week subspecialist mentor-based structure to be highly versatile, allowing us to simultaneously accommodate multiple groups of full or partial block rotators throughout COVID-19 mitigation. CONCLUSION: A virtual rotation curriculum is a viable method of maintaining medical student and intern education and engagement with the department of radiology during COVID-19 mitigation.

5.
Skeletal Radiol ; 48(3): 445-448, 2019 Mar.
Article in English | MEDLINE | ID: mdl-29846755

ABSTRACT

OBJECTIVE: To assess the impact of shifting arthrogram injectate compounding from the fluoroscopy suite to the main hospital sterile pharmacy on cost, examination delays, and infection rates. MATERIALS AND METHODS: All arthrograms from the 12 months before (629 in total) and the 12 months after (699 in total) the change in arthrogram preparation procedure were compared to identify differences in examination delays and infection rate. The arthrogram formulation was sent to the Compounder's International Analytical Laboratory for stability testing. Finally, cost per injection analysis was performed to compare fluoroscopy suite with sterile pharmacy compounding. RESULTS: In the 699 arthrograms performed in the 12 months following transfer of arthrogram preparation to the main hospital pharmacy, there were 0 reported examination delays, 0 reported infections, and a 53% decrease in the material cost per arthrogram. There were three recorded instances of fluoroscopy suite preparation of arthrogram injectate due to unexpected add-on patients. Outside stability testing determined that the arthrogram injectate retained at least 90% potency 30 h post-preparation. CONCLUSION: Shifting the compounding of the arthrogram injectate from the fluoroscopy room to the main hospital sterile pharmacy provides a modest cost saving and can be accomplished without examination delays or any increase in infection rate. It brought our practice into compliance with USP797, which is the current guideline for compounding practitioners, by transferring the compounding preparation of the arthrogram injectate from a procedure room to the sterile pharmacy.


Subject(s)
Contrast Media/chemistry , Drug Compounding/standards , Gadolinium DTPA/chemistry , Iopamidol/chemistry , Magnetic Resonance Imaging , Pharmacy Service, Hospital/standards , Contrast Media/economics , Cost Savings , Drug Compounding/economics , Fluoroscopy , Gadolinium DTPA/economics , Guideline Adherence , Humans , Iopamidol/economics , Pharmacy Service, Hospital/economics
6.
Cutis ; 93(3): 141-4, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24738095

ABSTRACT

Perineural invasion (PNI) is an uncommon manifestation of cutaneous squamous cell carcinoma (SCC). We report a case of recurrent cutaneous SCC with PNI diagnosed both clinically and histologically. We also provide a review the literature. Clinicians should be aware of this uncommon finding, as PNI has been associated with increased local recurrence, local and distant metastasis, and poor prognosis. Patients with clinical findings associated with perineural involvement have a poorer prognosis than those incidentally discovered on histologic examination, which emphasizes the importance of a thorough history and neurologic examination in patients with cutaneous SCC to identify those who will require more aggressive therapy.


Subject(s)
Carcinoma, Squamous Cell/pathology , Cranial Nerves/pathology , Head and Neck Neoplasms/pathology , Neoplasm Recurrence, Local/pathology , Paresthesia/pathology , Skin Neoplasms/pathology , Aged , Carcinoma, Squamous Cell/complications , Carcinoma, Squamous Cell/surgery , Head and Neck Neoplasms/complications , Head and Neck Neoplasms/surgery , Humans , Male , Mohs Surgery , Neoplasm Invasiveness , Neoplasm Recurrence, Local/complications , Neoplasm Recurrence, Local/surgery , Paresthesia/etiology , Skin Neoplasms/complications , Skin Neoplasms/surgery
7.
Dermatol Surg ; 40(4): 427-35, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24460761

ABSTRACT

BACKGROUND: The authors investigated the use of simulator platforms in fourth-year medical student education. OBJECTIVE: To evaluate which simulation platform students preferred for learning dermatologic procedures and to assess the effectiveness of the exercise in terms of the change in confidence that the students had performing dermatologic procedures. MATERIALS AND METHODS: After medical students were instructed on how to perform a punch biopsy and then assisted in executing the task, they were surveyed to determine their preferred simulation platform and simulator properties. Students were surveyed at the beginning and completion of the teaching block. RESULTS: One hundred fifty-seven students completed the skills laboratory, and 78 completed the preference questionnaire. Of the 11 surveyed categories, students preferred the pig foot in eight categories. Seventy students responded to a surgical skills questionnaire that assessed their overall confidence in planning and executing the procedure before and after the skills laboratory. The students had a statistically significant increase in confidence in dermatologic procedural skills as a result of the activity. CONCLUSION: Preference data show that the pig foot model is preferred for teaching dermatologic surgical skills. These results re-affirm that the pig foot model is an effective, low-cost solution for training.


Subject(s)
Attitude of Health Personnel , Dermatologic Surgical Procedures/education , Students, Medical , Animals , Biopsy , Female , Foot , Humans , Male , Manikins , Self Efficacy , Suture Techniques/education , Swine
SELECTION OF CITATIONS
SEARCH DETAIL
...