Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
Add more filters










Publication year range
1.
Appl Opt ; 55(18): 4814-9, 2016 Jun 20.
Article in English | MEDLINE | ID: mdl-27409104

ABSTRACT

Our work relates to the use of metamaterials engineered to realize a metasurface approaching the exotic properties of an ideal object not observed in nature, a "magnetic mirror." Previous realizations were based on resonant structures that implied narrow bandwidths and large losses. The working principle of our device is ideally frequency-independent, it does not involve resonances and it does not rely on a specific technology. The performance of our prototype, working at millimeter wavelengths, has never been achieved before and it is superior to any other device reported in the literature, both in the microwave and optical regions. The device inherently has large bandwidth (144%), low losses (<1%), and is almost independent of incidence angle and polarization state, and thus approaches the behavior of an ideal magnetic mirror. Applications of magnetic mirrors range from low-profile antennas, absorbers to optoelectronic devices. Our device can be realized using different technologies to operate in other spectral regions.

2.
Rev Sci Instrum ; 87(3): 033105, 2016 Mar.
Article in English | MEDLINE | ID: mdl-27036756

ABSTRACT

We have developed a passive 350 GHz (850 µm) video-camera to demonstrate lumped element kinetic inductance detectors (LEKIDs)--designed originally for far-infrared astronomy--as an option for general purpose terrestrial terahertz imaging applications. The camera currently operates at a quasi-video frame rate of 2 Hz with a noise equivalent temperature difference per frame of ∼0.1 K, which is close to the background limit. The 152 element superconducting LEKID array is fabricated from a simple 40 nm aluminum film on a silicon dielectric substrate and is read out through a single microwave feedline with a cryogenic low noise amplifier and room temperature frequency domain multiplexing electronics.

3.
Appl Opt ; 55(36): 10255-10262, 2016 Dec 20.
Article in English | MEDLINE | ID: mdl-28059242

ABSTRACT

The quasi-optical modulation of linear polarization at millimeter and sub-millimeter wavelengths can be achieved by using rotating half-wave plates (HWPs) in front of polarization-sensitive detectors. Large operational bandwidths are required when the same device is meant to work simultaneously across different frequency bands. Previous realizations of half-wave plates, ranging from birefringent multi-plates to mesh-based devices, have achieved bandwidths of the order of 100%. Here we present the design and experimental characterization of a reflective HWP able to work across bandwidths of the order of 150%. The working principle of the novel device is completely different from any previous realization, and it is based on the different phase-shift experienced by two orthogonal polarizations reflecting, respectively, off an electric conductor and an artificial magnetic conductor.

4.
Opt Express ; 20(23): 25766-73, 2012 Nov 05.
Article in English | MEDLINE | ID: mdl-23187394

ABSTRACT

Stacked layers of metal meshes embedded in a dielectric substrate are routinely used for providing spectral selection at THz frequencies. Recent work has shown that particular geometries allow the refractive index to be tuned to produce practical artificial materials. Here we show that by spatially grading in the plane of the mesh we can manufacture a Graded Index (GrIn) thin flat lens optimized for use at THz frequencies. Measurements on a prototype lens show we are able to obtain the parabolic profile of a Woods type lens which is dependent only on the mesh parameters. This technique could realize other exotic optical devices.

5.
Appl Opt ; 51(12): 2202-11, 2012 Apr 20.
Article in English | MEDLINE | ID: mdl-22534934

ABSTRACT

A laboratory prototype spectral-spatial interferometer has been constructed to demonstrate the feasibility of the double-Fourier technique at far infrared (FIR) wavelengths (0.15-1 THz). It is planned to use this demonstrator to investigate and validate important design features and data-processing methods for future astronomical FIR interferometer instruments. In building this prototype, we have had to address several key technologies to provide an end-end system demonstration of this double-Fourier interferometer. We report on the first results taken when viewing single-slit and double-slit sources at the focus of a large collimator used to simulate real sources at infinity. The performance of the prototype instrument for these specific field geometries is analyzed to compare with the observed interferometric fringes and to demonstrate image reconstruction capabilities.

6.
Rev Sci Instrum ; 82(6): 064502, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21721713

ABSTRACT

We investigate the possibility of using a flat-fold beam steering mirror for a cosmic microwave background B-mode experiment. An aluminium flat-fold mirror is found to add ∼0.075% polarization, which varies in a scan synchronous way. Time-domain simulations of a realistic scanning pattern are performed, and the effect on the power-spectrum illustrated, and a possible method of correction applied.

7.
Appl Opt ; 50(21): 3750-7, 2011 Jul 20.
Article in English | MEDLINE | ID: mdl-21772356

ABSTRACT

We describe a novel multilayered metal-mesh achromatic half-wave plate (HWP) for use in astronomical polarimetric instruments. The HWP is designed to operate across the frequency range from 125 to 250 GHz. The wave plate is manufactured from 12 layers of thin film metallic inductive and capacitive grids patterned onto polypropylene sheets, which are then bonded together using a hot-pressing technique. Transmission line modeling and three-dimensional electromagnetic simulations are used to optimize the parameters of the metal-mesh patterns and to evaluate their optical properties. A prototype HWP has been fabricated, and its performance is characterized in a polarizing Fourier transform spectrometer. The device performance is consistent with the modeling, although the measured differential phase shift for two orthogonal polarizations is lower than expected. This difference is likely to result from imperfect patterning of individual layers and misalignment of the grids during manufacture.

8.
Appl Opt ; 48(11): 2006-13, 2009 Apr 10.
Article in English | MEDLINE | ID: mdl-19363537

ABSTRACT

A spectro-polarimetric method is presented to allow the recovery of the frequency dependent polarization modulation function for an achromatic half-wave plate. We show how the non ideal nature of the modulator can be characterized for removal of both instrument effects and variations related to the source spectral index.

9.
Nature ; 458(7239): 737-9, 2009 Apr 09.
Article in English | MEDLINE | ID: mdl-19360081

ABSTRACT

Submillimetre surveys during the past decade have discovered a population of luminous, high-redshift, dusty starburst galaxies. In the redshift range 1 or= 1.2 accounting for 70% of it. As expected, at the longest wavelengths the signal is dominated by ultraluminous galaxies at z > 1.

10.
Appl Opt ; 47(33): 6251-6, 2008 Nov 20.
Article in English | MEDLINE | ID: mdl-19023391

ABSTRACT

A metal-mesh achromatic half-wave plate (HWP) has been designed, manufactured, and tested for potential use in millimeter and submillimeter astronomical instruments. The prototype device presented here is based on a 12-grid Shatrow [IEEE Trans. Antennas Propag. 43, 109 (1995)] recipe to operate over the frequency range of 120-180 GHz. Transmission line modeling and finite-element analysis [Ansoft HFSS website: http://www.ansoft.com/hfss/] were used to optimize the design geometrical parameters in terms of the device transmission, reflection, absorption, phase-shift, and cross-polarization as a function of frequency. The resulting prototype device was constructed and characterized using incoherent radiation from a polarizing Fourier transform spectrometer to explore its frequency and polarization behavior. These measurements are shown to be in excellent agreement with the models. Lists of the achieved HWP performance characteristics are reported.

11.
Rev Sci Instrum ; 78(2): 024502, 2007 Feb.
Article in English | MEDLINE | ID: mdl-17578131

ABSTRACT

SCUBA-2 is a submillimeter camera being built for the James Clerk Maxwell Telescope in Hawaii. Bringing CCD style imaging to the submillimeter for the first time, with over 10000 pixels, it will provide a revolutionary improvement in sensitivity and mapping speed. We present results of the first tests on a prototype 1280 pixel SCUBA-2 subarray; the full instrument will be made up of eight such subarrays. The array is made up of transition edge sensor (TES) detectors, with Mo/Cu bilayers as the sensing element. To keep the number of wires reasonable, a multiplexed readout is used. Unlike previous TES arrays, an in-focal plane multiplexer configuration is used, in which the multiplexing elements are located beneath each pixel. To achieve the required performance, the detectors are operated at a temperature of approximately 120 mK. We describe the results of a basic electrical and optical characterization of the array, demonstrating that it is fully operational. Noise measurements were made on several pixels and gave a noise equivalent power below 2.5 x 10(-17) W HZ(-0.5), within the requirements for SCUBA-2. The construction of the testbed used to carry out these measurements is also described.

12.
Appl Opt ; 45(35): 8907-15, 2006 Dec 10.
Article in English | MEDLINE | ID: mdl-17119591

ABSTRACT

We adopted an existing formalism and modified it to simulate, with high precision, the transmission, reflection, and absorption of multiple-plate birefringent devices as a function of frequency. To validate the model, we use it to compare the measured properties of an achromatic five-plate device with a broadband antireflection coating to expectations derived from the material optical constants and its geometric configuration. The half-wave plate presented here is observed to perform well with a phase shift variation of < 2 degrees from the ideal 180 degrees over a bandwidth of Deltav/v approximately 1 at millimeter wavelengths. This formalism represents a powerful design tool for birefringent polarization modulators and enables its optical properties to be specified with high accuracy.

13.
Appl Opt ; 45(27): 6982-9, 2006 Sep 20.
Article in English | MEDLINE | ID: mdl-16946775

ABSTRACT

An achromatic half-wave plate (HWP) to be used in millimeter cosmic microwave background (CMB) polarization experiments has been designed, manufactured, and tested. The design is based on the 5-plates Pancharatnam recipe and it works in the frequency range 85-185 GHz. A model has been used to predict the transmission, reflection, absorption, and phase shift as a function of frequency. The HWP has been tested by using coherent radiation from a back-wave oscillator to investigate its modulation efficiency and with incoherent radiation from a polarizing Fourier transform spectrometer (FTS) to explore its frequency behavior. The FTS measurements have been fitted with an optical performance model which is in excellent agreement with the data. A detailed analysis of the data also allows a precise determination of the HWP fast and slow axes in the frequency band of operation. A list of the HWP performance characteristics is reported including estimates of its cross polarization.

14.
Appl Opt ; 42(25): 5009-16, 2003 Sep 01.
Article in English | MEDLINE | ID: mdl-12962375

ABSTRACT

Bolometers designed to detect submillimeter radiation also respond to cosmic, gamma, and x rays. Because detectors cannot be fully shielded from such energy sources, it is necessary to understand the effect of a photon or cosmic-ray particle being absorbed. The resulting signal (known as a glitch) can then be removed from raw data. We present measurements using an Americium-241 gamma radiation source to irradiate a prototype bolometer for the High Frequency Instrument in the Planck Surveyor satellite. Our measurements showed no variation in response depending on where the radiation was absorbed, demonstrating that the bolometer absorber and thermistor thermalize quickly. The bolometer has previously been fully characterized both electrically and optically. We find that using optically measured time constants underestimates the time taken for the detector to recover from a radiation absorption event. However, a full thermal model for the bolometer, with parameters taken from electrical and optical measurements, provides accurate time constants. Slight deviations from the model were seen at high energies; these can be accounted for by use of an extended model.

15.
Appl Opt ; 41(13): 2561-74, 2002 May 01.
Article in English | MEDLINE | ID: mdl-12009168

ABSTRACT

The South Pole Imaging Fabry-Perot Interferometer (SPIFI) is the first instrument of its kind-a direct-detection imaging spectrometer for astronomy in the submillimeter band. SPIFI's focal plane is a square array of 25 silicon bolometers cooled to 60 mK; the spectrometer consists of two cryogenic scanning Fabry-Perot interferometers in series with a 60-mK bandpass filter. The instrument operates in the short submillimeter windows (350 and 450 microm) available from the ground, with spectral resolving power selectable between 500 and 10,000. At present, SPIFI's sensitivity is within a factor of 1.5-3 of the photon background limit, comparable with the best heterodyne spectrometers. The instrument's large bandwidth and mapping capability provide substantial advantages for specific astrophysical projects, including deep extragalactic observations. We present the motivation for and design of SPIFI and its operational characteristics on the telescope.

SELECTION OF CITATIONS
SEARCH DETAIL
...