Skeletal Radiol ; 2024 Mar 16.
Article in English | MEDLINE | ID: mdl-38492028

ABSTRACT

During the past four decades, ultrasound has become popular as an imaging modality applied to the musculoskeletal (MSK) system, particularly outside the USA, due to its low cost, accessibility, and lack of ionizing radiation. A basic requirement in performing these examinations is to have a core group of radiologists and ultrasound technologists with expertise in MSK ultrasound. The extent to which ultrasound will be part of the imaging offered by a particular radiology practice or in an academic institution will vary according to expertise, availability, and reimbursements. A brief discussion of the technical capabilities of the current generation of ultrasound scanners will be followed by a description of some of the more prevalent MSK ultrasound imaging applications. The extent to which training to perform these exams within and outside of Radiology plays a role is discussed. Applications that are unique to ultrasound, such as dynamic evaluation of musculoskeletal anatomy and some, US-guided interventions are an important part of MSK imaging. Ultrasound is increasingly important in the assessment of superficial structures, such as tendons, small joints, and peripheral nerves. These applications help to establish the place of ultrasound as an important part of the Radiologists approach to MSK imaging. Outside of radiology, for a variety of clinical subspecialties, ultrasound already plays an integral role in MSK imaging.

2.
Skeletal Radiol ; 53(3): 577-582, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37566147

ABSTRACT

Pronator syndrome is a median nerve entrapment neuropathy that can be difficult to diagnose due to its variable presentation and objective findings. Neurolymphomatosis is an uncommon disease in which malignant lymphocytes infiltrate central or peripheral nerve endoneurium and is often missed for prolonged periods prior to diagnosis. We present a rare case of pronator syndrome and anterior interosseous nerve palsy due to neurolymphomatosis that was occult on initial MRI in spite of the presence of a median nerve mass discovered intra-operatively during neurolysis. This case demonstrates the value of ultrasound for the examination of peripheral nerve pathology and illustrates its utility as an adjunct to MRI, in part due to the ability to screen a large region.


Subject(s)
Median Neuropathy , Nerve Compression Syndromes , Neurolymphomatosis , Humans , Median Neuropathy/complications , Median Neuropathy/diagnosis , Median Neuropathy/pathology , Median Nerve/pathology , Forearm/innervation , Paralysis/complications , Paralysis/pathology , Nerve Compression Syndromes/surgery
3.
J Ultrason ; 23(95): e347-e357, 2023 Oct.
Article in English | MEDLINE | ID: mdl-38020507

ABSTRACT

Ultrasound visualization affords proceduralists versatile and accurate guidance for a variety of percutaneous, minimally invasive procedures in the musculoskeletal system including joint (intra-articular) injections or aspirations, intra-bursal injections, peritendinous, and perineural injections. A variety of percutaneous procedures are traditionally performed blindly, but may be more easily or more accurately performed with the real-time assistance of ultrasound guidance. Other procedures are only possible utilizing image-guidance, due to the required precision of the injection because of delicate local anatomy or depth of the injection; ultrasound is a safe, portable, and widespread modality that can be used to assist the proceduralist in localizing the needle tip in such cases, to ensure safe and accurate delivery of the medication, most frequently a solution of steroid and anesthetic. This review aims to provide a foundational approach to ultrasound-guided procedures in the musculoskeletal system, offering tips and tricks that can be employed in many different procedures including intra-articular, juxta-articular, and perineural injections for a multitude of clinical scenarios. Technical considerations regarding ultrasound transducer selection, sonographic technique, as well as common indications, contraindications, and complications of these procedures, are presented. Additionally, a variety of pharmacologic considerations for proceduralists contemplating ultrasound-guided injections are discussed.

4.
J Ultrason ; 23(95): e172-e187, 2023 Oct.
Article in English | MEDLINE | ID: mdl-38020513

ABSTRACT

During the past four decades, musculoskeletal ultrasound has become popular as an imaging modality due to its low cost, accessibility, and lack of ionizing radiation. The development of ultrasound technology was possible in large part due to concomitant advances in both solid-state electronics and signal processing. The invention of the transistor and digital computer in the late 1940s was integral in its development. Moore's prediction that the number of microprocessors on a chip would grow exponentially, resulting in progressive miniaturization in chip design and therefore increased computational power, added to these capabilities. The development of musculoskeletal ultrasound has paralleled technical advances in diagnostic ultrasound. The appearance of a large variety of transducer capabilities and rapid image processing along with the ability to assess vascularity and tissue properties has expanded and continues to expand the role of musculoskeletal ultrasound. It should also be noted that these developments have in large part been due to a number of individuals who had the insight to see the potential applications of this developing technology to a host of relevant clinical musculoskeletal problems. Exquisite high-resolution images of both deep and small superficial musculoskeletal anatomy, assessment of vascularity on a capillary level and tissue mechanical properties can be obtained. Ultrasound has also been recognized as the method of choice to perform a large variety of interventional procedures. A brief review of these technical developments, the timeline over which these improvements occurred, and the impact on musculoskeletal ultrasound is presented below.

5.
Magn Reson Imaging Clin N Am ; 31(2): 255-267, 2023 May.
Article in English | MEDLINE | ID: mdl-37019549

ABSTRACT

Multimodality imaging of the brachial plexus is essential to accurately localize the lesion and characterize the pathology and site of injury. A combination of computed tomography (CT), ultrasound, and MR imaging is useful along with clinical and nerve conduction studies. Ultrasound and MR imaging in combination are effective to accurately localize the pathology in most of the cases. Accurate reporting of the pathology with dedicated MR imaging protocols in conjunction with Doppler ultrasound and dynamic imaging provides practical and useful information to help the referring physicians and surgeons to optimize medical or surgical treatment regimens.


Subject(s)
Brachial Plexus Neuropathies , Brachial Plexus , Humans , Magnetic Resonance Imaging/methods , Brachial Plexus/diagnostic imaging , Brachial Plexus/injuries , Brachial Plexus/pathology , Ultrasonography , Tomography, X-Ray Computed , Multimodal Imaging , Brachial Plexus Neuropathies/pathology
6.
AJR Am J Roentgenol ; 220(3): 399-406, 2023 03.
Article in English | MEDLINE | ID: mdl-36259594

ABSTRACT

Preoperative localization of nonpalpable breast lesions using a radar reflector surgical guidance system has become commonplace, but the clinical utility of this emerging technology in the musculoskeletal system has not yet been well established. The system components include a console, a handpiece, an implanted radiofrequency reflector that works as a lesion marker, and an infrared light-emitting probe to guide the surgeon. The reflector can be deployed to localize small nonpalpable nodules within the subcutaneous fat as well as lesions within the deeper soft tissues. It can also be used for lymph nodes and foreign bodies. Localization can be performed both before and after treatment. The objective of this article is to describe the potential applications and our technique and initial experience for radar reflector localization within the musculoskeletal system.


Subject(s)
Breast Neoplasms , Musculoskeletal System , Surgery, Computer-Assisted , Humans , Female , Radar , Mastectomy, Segmental/methods , Surgery, Computer-Assisted/methods
7.
Eur Radiol ; 32(10): 6759-6768, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35579710

ABSTRACT

OBJECTIVES: To determine the incidence of infectious complications following ultrasound-guided musculoskeletal interventions performed with a disinfected uncovered ultrasound transducer footprint. METHODS: Electronic medical records of all patients who underwent an ultrasound-guided musculoskeletal procedure (including injection, calcific lavage, or ganglion cyst aspiration) performed by any of the 14 interventional musculoskeletal radiologists at our institution between January 2013 and December 2018 were retrospectively reviewed to identify procedure site infections. Biopsies and joint aspirations were excluded. The procedures were performed using a disinfected uncovered transducer footprint. First, an automated chart review identified cases with (1) positive answers to the nurse's post-procedure call, (2) an International Classification of Diseases (ICD) diagnostic code related to a musculoskeletal infection, or (3) an antibiotic prescription within 30 days post-procedure. Then, these cases were manually reviewed for evidence of procedure site infection. RESULTS: In total, 6511 procedures were included. The automated chart review identified 3 procedures (2 patients) in which post-procedural fever was reported during the nurse's post-procedure call, 33 procedures (28 patients) with an ICD code for a musculoskeletal infection, and 220 procedures (216 patients) with an antibiotic prescription within 30 post-procedural days. The manual chart review of these patients revealed no cases of confirmed infection and 1 case (0.015%) of possible site infection. CONCLUSIONS: The incidence of infectious complications after an ultrasound-guided musculoskeletal procedure performed with an uncovered transducer footprint is extremely low. This information allows radiologists to counsel their patients more precisely when obtaining informed consent. KEY POINTS: • Infectious complications after ultrasound-guided musculoskeletal procedures performed with a disinfected uncovered transducer footprint are extremely rare.


Subject(s)
Transducers , Ultrasonography, Interventional , Anti-Bacterial Agents/therapeutic use , Humans , Incidence , Retrospective Studies , Ultrasonography, Interventional/methods
8.
J Am Board Fam Med ; 35(2): 427-434, 2022.
Article in English | MEDLINE | ID: mdl-35379732

ABSTRACT

INTRODUCTION: Improving design, selection and implementation of appropriate clinical quality measures can reduce harms and costs of health care and improve the quality and experience of care delivery. These measures have not been evaluated for appropriateness for use in performance measurement in a systematic, reproducible, and widely accepted manner. METHODS: We defined 10 criteria for evaluation of measure appropriateness in 4 domains: Patient-centeredness of outcomes, specification of population measured and measure detail, reliable evidence that benefits likely outweigh harms, and independence from significant confounders. We applied these criteria to 24 measures under consideration for statewide use in Massachusetts in public and private incentive-based programs. We appraised each measure as Appropriate or Not Appropriate for such use. RESULTS: We rated 15 measures as Appropriate (62.5%). Three measures (12.5%) were considered Appropriate only if applied at a system level but not for patient-provider assessment and 6 measures (25%) were rated Not Appropriate. Reasons for designation as "Not Appropriate" included benefits not clearly outweighing harms, lack of preservation of patient autonomy, inappropriate specification of population and measure detail, confounding by locus of control, and confounding by social determinants of health. CONCLUSIONS: Using this consensus-driven, 10-criteria methodology we were able to evaluate appropriateness of clinical quality measures. This methodology may improve measure design and inform selection of the most appropriate measures for use in quality measurement, financial incentives, and reporting.


Subject(s)
Motivation , Physicians, Family , Delivery of Health Care , Humans , Massachusetts
10.
Semin Musculoskelet Radiol ; 26(6): 744-754, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36791742

ABSTRACT

A variety of foot and ankle pathologies can impair patient's daily activities, ultimately requiring surgical management. However, with improvements in image-guided intervention, the joints, soft tissues, and osseous structures may be accessible using various percutaneous techniques as a potential alternative therapeutic tool, avoiding the need for surgery with its associated risks and morbidity. This article discusses the potential range of image-guided interventional treatments. Injections, aspiration, biopsies, cryoablation, and radiofrequency ablation are described. Newer novel treatments are also covered. Finally, the common pathologies of Morton's neuroma, Achilles tendinopathy, and plantar fasciitis are addressed.


Subject(s)
Achilles Tendon , Tendinopathy , Humans , Ankle/diagnostic imaging , Ankle/surgery , Achilles Tendon/diagnostic imaging , Achilles Tendon/surgery , Ankle Joint/diagnostic imaging , Ankle Joint/surgery , Ultrasonography, Interventional
11.
Semin Musculoskelet Radiol ; 25(6): 769-784, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34937117

ABSTRACT

Musculoskeletal injections serve a variety of diagnostic and therapeutic purposes, with ultrasonography (US) guidance having many advantages: no ionizing radiation, real-time guidance, high spatial resolution, excellent soft tissue contrast, and the ability to identify and avoid critical structures. Sonography can be cost effective and afford flexibility in resource-constrained settings. This article describes US-guided musculoskeletal injections relevant to many radiology practices and provides experience-based suggestions. Structures covered include multiple joints (shoulder, hip), bursae (iliopsoas, subacromial-subdeltoid, greater trochanteric), peripheral nerves (sciatic, radial), and tendon sheaths (posterior tibial, peroneal, flexor hallucis longus, Achilles, long head of the biceps). Trigger point and similar targeted steroid injections, as well as calcific tendinopathy barbotage, are also described.


Subject(s)
Tendinopathy , Ultrasonography, Interventional , Humans , Injections , Shoulder , Ultrasonography
12.
J Clin Ultrasound ; 49(9): 969-975, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34536025

ABSTRACT

PURPOSE: To describe our experience using ultrasound (US) to evaluate postoperative complications in the presence of in situ shoulder arthroplasty. METHODS: Review of patients who underwent US evaluation following total shoulder arthroplasty (TSA), reverse total shoulder arthroplasty (RTSA) or hemiarthroplasty from 2007 to 2020. All studies were reviewed independently by two musculoskeletal radiologists to assess for joint effusion, periarticular collection, and characterization of associated rotator cuff tears. Tendon tears were assessed with respect to (1) thickness: low grade (<50% thickness), high grade (>50% thickness), full thickness; (2) morphology (focal vs. diffuse) and location (insertion vs. critical zone). Inter-reader agreements were determined using Cohen's kappa test. RESULTS: Ninety-seven studies were performed in 72 patients following TSA, RTSA, or hemiarthroplasty. Thirty-seven exams were solely for diagnostic purposes, and 59 were for guiding joint or periarticular collection aspiration. Twenty-eight studies assessed the cuff tendons post TSA. The mean time between surgery and US examination was 29.2 months. Complete or high-grade tears were identified in 8/28 (28.6%) diagnostic exams. The most commonly torn tendon among TSA patients was the subscapularis, with 13/28 (46.4%) demonstrating at least partial tearing. Inter-reader agreement was excellent for presence of effusion (k = 0.79, p < .001) and periarticular collection (k = 0.87, p < .001), and excellent agreement for presence of subscapularis tear (k = 0.78, p < .001), with fair agreement for assessment of supraspinatus (k = 0.66, p < .001) and infraspinatus (k = 0.60, p < .001) tears. CONCLUSION: The most commonly torn tendon following anatomic TSA identified by US was the subscapularis, which was torn or deficient in 46.4% of cases. The majority of studies were performed for the guidance of percutaneous aspiration.


Subject(s)
Arthroplasty, Replacement, Shoulder , Rotator Cuff Injuries , Shoulder Joint , Humans , Magnetic Resonance Imaging , Prevalence , Rotator Cuff , Rotator Cuff Injuries/diagnostic imaging , Rotator Cuff Injuries/surgery , Shoulder Joint/diagnostic imaging , Shoulder Joint/surgery , Treatment Outcome
13.
Radiol Artif Intell ; 3(1): e200125, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33937855

ABSTRACT

PURPOSE: To train convolutional neural network (CNN) models to classify benign and malignant soft-tissue masses at US and to differentiate three commonly observed benign masses. MATERIALS AND METHODS: In this retrospective study, US images obtained between May 2010 and June 2019 from 419 patients (mean age, 52 years ± 18 [standard deviation]; 250 women) with histologic diagnosis confirmed at biopsy or surgical excision (n = 227) or masses that demonstrated imaging characteristics of lipoma, benign peripheral nerve sheath tumor, and vascular malformation (n = 192) were included. Images in patients with a histologic diagnosis (n = 227) were used to train and evaluate a CNN model to distinguish malignant and benign lesions. Twenty percent of cases were withheld as a test dataset, and the remaining cases were used to train the model with a 75%-25% training-validation split and fourfold cross-validation. Performance of the model was compared with retrospective interpretation of the same dataset by two experienced musculoskeletal radiologists, blinded to clinical history. A second group of US images from 275 of the 419 patients containing the three common benign masses was used to train and evaluate a separate model to differentiate between the masses. The models were trained on the Keras machine learning platform (version 2.3.1), with a modified pretrained VGG16 network. Performance metrics of the model and of the radiologists were compared by using the McNemar test, and 95% CIs for performance metrics were estimated by using the Clopper-Pearson method (accuracy, recall, specificity, and precision) and the DeLong method (area under the receiver operating characteristic curve). RESULTS: The model trained to classify malignant and benign masses demonstrated an accuracy of 79% (95% CI: 68, 88) on the test data, with an area under the receiver operating characteristic curve of 0.91 (95% CI: 0.84, 0.98), matching the performance of two expert readers. Performance of the model distinguishing three benign masses was lower, with an accuracy of 71% (95% CI: 61, 80) on the test data. CONCLUSION: The trained CNN was capable of differentiating between benign and malignant soft-tissue masses depicted on US images, with performance matching that of two experienced musculoskeletal radiologists.© RSNA, 2020.

14.
J Ultrasound Med ; 40(8): 1515-1522, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33058264

ABSTRACT

OBJECTIVES: To evaluate whether a follow-up magnetic resonance imaging (MRI) scan performed after initial ultrasound (US) to evaluate soft tissue mass (STM) lesions of the musculoskeletal system provides additional radiologic diagnostic information and alters clinical management. METHODS: A retrospective chart review was performed of patients undergoing initial US evaluations of STMs of the axial or appendicular skeleton between November 2012 and March 2019. Patients who underwent US examinations followed by MRI for the evaluation of STM lesions were identified. For inclusion, the subsequent pathologic correlation was required from either a surgical or image-guided biopsy. Imaging studies with pathologic correlations were then reviewed by 3 musculoskeletal radiologists, who were blinded to the pathologic diagnoses. The diagnostic utility of MRI was then assessed on the basis of a 5-point grading scale, and inter-reader agreements were determined by the Fleiss κ statistic. RESULTS: Ninety-two patients underwent MRI after US for STM evaluations. Final pathologic results were available in 42 cases. Samples were obtained by surgical excision or open biopsy (n = 34) or US-guided core biopsy (n = 8). The most common pathologic diagnoses were nerve sheath tumors (n = 9), lipomas (n = 5), and leiomyomas (n = 5). Imaging review showed that the subsequent MRI did not change the working diagnosis in 73% of cases, and the subsequent MRI was not considered to narrow the differential diagnosis in 68% of cases. There was slight inter-reader agreement for the diagnostic utility of MRI among individual cases (κ = 0.10) between the 3 readers. CONCLUSIONS: The recommendation of MRI to further evaluate STM lesions seen with US frequently fails to change the working diagnosis or provide significant diagnostic utility.


Subject(s)
Image-Guided Biopsy , Magnetic Resonance Imaging , Diagnosis, Differential , Humans , Retrospective Studies , Ultrasonography
15.
J Am Soc Cytopathol ; 10(2): 135-140, 2021.
Article in English | MEDLINE | ID: mdl-33097463

ABSTRACT

INTRODUCTION: Colposcopic endocervical brushing cytology (CEB) is more sensitive than endocervical curettage (ECC) for detecting squamous intraepithelial lesions. There are no data on performance of CEB for detecting endocervical adenocarcinoma. MATERIALS AND METHODS: A total of 151 patients were identified in a word search for "endocervical adenocarcinoma" in surgical pathology reports from January 2007 to June 2019. To measure sensitivity, reports of CEB or ECC samples within 1 year preceding the first surgical pathology diagnosis of at least endocervical adenocarcinoma in situ (AIS+) were examined. Specificity was measured in a cohort in which at least atypical glandular cells (AGC+) was reported in CEB or ECC. RESULTS: Seven CEB preceding diagnosis of AIS were identified: 6 of 7 were positive or suspicious for AIS+. One of 7 was negative and it was negative on re-review. Three of 6 positive CEB cases used cell blocks with immunohistochemistry. Seventy ECC samples preceding diagnosis of AIS were identified: 40 of 70 were diagnosed as AGC+. The sensitivities of CEB and ECC for detecting AIS+ at a threshold of AGC+ are 86% and 57% (too few patients for statistics), respectively. For specificity, 12 of 18 CEB and 9 of 25 ECC reports with AGC+ were false positive by follow-up surgical pathology. The specificities of CEB and ECC are 99.4% and 99.9%, respectively. CONCLUSION: Sensitivity of CEB for detecting AIS+ (86%) is at least as high as ECC (57%). Specificity of CEB is similar to ECC. Addition of a cell block to CEB may be useful. CEB appears to be an appropriate test for follow-up of atypical glandular cells reported on Papanicolaou tests.


Subject(s)
Adenocarcinoma/diagnosis , Cervix Uteri/pathology , Colposcopy/methods , Uterine Cervical Neoplasms/diagnosis , Adenocarcinoma/pathology , Adult , Cervix Uteri/cytology , Curettage/methods , Early Detection of Cancer/methods , Female , Humans , Middle Aged , Sensitivity and Specificity , Uterine Cervical Neoplasms/pathology
16.
J Ultrasound Med ; 40(10): 2055-2068, 2021 Oct.
Article in English | MEDLINE | ID: mdl-33258512

ABSTRACT

OBJECTIVE: To determine whether the healing response in rotator cuff repairs can be quantitatively characterized using a multimodality imaging approach with MR signal intensity, power Doppler and shear wave elastography (SWE). MATERIALS AND METHODS: Patients scheduled for rotator cuff repair were prospectively enrolled between September 2013 and June 2016. A 12 patient cohort with unilateral, full-thickness, supraspinatus tendon tears underwent MRI and ultrasound both preoperatively and postoperatively (at 3 and 6 months post-surgery). The MR signal intensity ratio of tendon-to-deltoid muscle (TMR), vascularity score by power Doppler (PD) and shear wave velocity (SWV) were measured. Repaired and asymptomatic control shoulders were compared over time and between modalities. RESULTS: TMR and vascularity of the tendon repair initially increased and then decreased postoperatively. Although not achieving statistical significance, postoperative SWV initially decreased and later increased, which negatively correlated with the TMR at 3 months (r = -0.73, p = 0.005). PD demonstrated a statistically significant change in tendon vascularity over time compared to the contralateral control (p = 0.009 at 3 months; p = 0.036 at 6 months). No significant correlation occurred between TMR and SWE at 6 months, or with PD at any time point. CONCLUSION: Despite a small patient cohort, this prospective pilot study suggests a temporal relationship of MRI and ultrasound parameters that parallels the expected phases of healing in the repaired rotator cuff.


Subject(s)
Elasticity Imaging Techniques , Rotator Cuff Injuries , Arthroscopy , Humans , Magnetic Resonance Imaging , Pilot Projects , Prospective Studies , Rotator Cuff/diagnostic imaging , Rotator Cuff/surgery , Rotator Cuff Injuries/diagnostic imaging , Rotator Cuff Injuries/surgery , Treatment Outcome
17.
Ultrasound Q ; 36(4): 357-362, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33298773

ABSTRACT

Ultrasound-guided hookwire localization was initially introduced to facilitate the excision of nonpalpable breast lesions by guiding surgical exploration, thereby reducing operative time and morbidity. The same technique has since found utility in a range of other applications outside breast and can be useful within the musculoskeletal system. Despite this, there remains limited literature with respect to its technical aspects and practical utility. We describe our technique and a series of preoperative ultrasound-guided wire localizations in the musculoskeletal system to assist surgical excision of 4 soft tissue masses.


Subject(s)
Preoperative Care/methods , Soft Tissue Neoplasms/diagnostic imaging , Soft Tissue Neoplasms/surgery , Surgical Equipment , Ultrasonography, Interventional/methods , Aged , Female , Humans , Male , Middle Aged , Musculoskeletal System/diagnostic imaging , Musculoskeletal System/surgery
19.
Skeletal Radiol ; 49(7): 1167-1174, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32076761

ABSTRACT

Adult T cell leukemia/lymphoma (ATLL) is a mature T cell neoplasm caused by the human oncogenic retrovirus human T lymphotropic virus type-1 (HTLV-1). While several musculoskeletal manifestations have been described in ATLL, skeletal muscle involvement is unusual, with only four cases reported in the English-language literature. We present a rare case of ATLL manifesting as an intra-muscular calf mass in a 58-year-old man who immigrated to the USA from West Africa. While skeletal muscle involvement by lymphoma is uncommon, it remains important to consider within the differential diagnosis when there are suggestive imaging findings because it entails important technical biopsy considerations as well as treatment implications. This case report also raises awareness of ATLL presenting outside of typical HTLV-1 endemic areas, related to current population migration patterns. ATLL should therefore be considered in patients with appropriate risk factors.


Subject(s)
Leg , Leukemia-Lymphoma, Adult T-Cell/diagnostic imaging , Muscle Neoplasms/diagnostic imaging , Biopsy, Large-Core Needle , Diagnosis, Differential , Fluorodeoxyglucose F18 , Human T-lymphotropic virus 1 , Humans , Leukemia-Lymphoma, Adult T-Cell/drug therapy , Magnetic Resonance Imaging , Male , Middle Aged , Muscle Neoplasms/drug therapy , Positron Emission Tomography Computed Tomography , Radiopharmaceuticals , Ultrasonography, Doppler
20.
Acad Radiol ; 27(4): 518-527, 2020 04.
Article in English | MEDLINE | ID: mdl-31279644

ABSTRACT

RATIONALE AND OBJECTIVES: The medial plantar proper digital nerve, also called Joplin's nerve, arises from the medial plantar nerve, courses along the medial hallux metatarsophalangeal joint, and can be a source of neuropathic pain due to various etiologies, following acute injury including bunion surgery and repetitive microtrauma. We describe our clinical experience with diagnostic ultrasound assessment of Joplin's neuropathy and technique for ultrasound-guided therapeutic intervention including both injection and cryoablation over a 6-year period. MATERIALS AND METHODS: Retrospective review of all diagnostic studies performed for Joplin's neuropathy and therapeutic Joplin's nerve ultrasound-guided injections and cryoablations between 2012 and 2018 was performed. Indications for therapeutic injection and cryoablation, were recorded. Studies were assessed for sonographic abnormalities related to the nerve and perineural soft tissues. Post-treatment outcomes including immediate pain scores, clinical follow-up, and periprocedural complications were documented. RESULTS: Twenty-four ultrasound-guided procedures were performed, including 15 perineural injections and nine cryoablations. With respect to sonographic abnormalities, nerve thickening (33%) and perineural hypoechoic scar tissue (27%) were the most common findings. The mean pain severity score prior to the therapeutic injection was 6.4/10 (range 4-10) and 0.25/10 (range 0-2) following the procedure; mean follow-up was 26.2 months (range 3-63 months). All of the cryoablation patients experienced sustained pain relief with a mean length follow-up of 3.75 months (range 0.2-10 months). CONCLUSION: Therapeutic injection of Joplin's nerve is a safe and easily performed procedure under ultrasound guidance, with high rates of immediate symptom improvement. For those experiencing a relapse or recurrent symptoms, cryoablation offers an effective secondary potential treatment option.


Subject(s)
Cryosurgery , Tibial Nerve , Ultrasonography, Interventional , Humans , Retrospective Studies , Tibial Nerve/diagnostic imaging , Treatment Outcome , Ultrasonography
SELECTION OF CITATIONS