Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
J Esthet Restor Dent ; 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38655672

ABSTRACT

OBJECTIVE: This randomized controlled clinical trial compared the clinical efficacy of self-adhesive bulk-fill Surefil One with a traditional bulk-fill composite in class II restorations. MATERIALS AND METHODS: Sixty-four direct class II composite restorations were categorized into two groups. Group I, control group (n = 32): cavities were restored by Filtek One bulk-fill composite with Scotchbond Universal (SBU) adhesive in self-etch mode, Group II, test group (n = 32): cavities were restored by Surefil One self-adhesive bulk-fill composite. The study involved a follow-up period of 1 year, during which restorations were assessed at baseline (BL), 6 months, and 12 months using Federation Dentaire Internationale (FDI) criteria. Data analysis was performed using nonparametric tests. A comparison of restoration characteristics was performed utilizing the chi-square test (X2). The significance level was set at 0.05. RESULTS: Filtek One and Surefil One bulk-fill composites revealed clinically acceptable FDI scores over 12-month recalls. Thirty-two patients (64 restorations) were available for all follow-up visits; 100% of the restorations survived. For esthetic properties, Filtek One was far better than Surefil One at all time points. However, in terms of functional and biological properties, both restorations demonstrated comparable performances. CONCLUSIONS: Filtek One bulk-fill restorations were superior in terms of surface luster, surface staining, color match, and translucency, but Surefil One restorations performed well and were similar to Filtek One restorations; however, additional advancements and research are needed to obtain better esthetics. Furthermore, longitudinal studies with extended follow-up periods are needed to assess the clinical potential of both materials. CLINICAL SIGNIFICANCE: Both Filtek One and Surefil One met the FDI criteria, with Filtek One demonstrating superior esthetic and functional qualities and similar performance regarding biological criteria. Both innovative restorative materials show potential for clinical use. Trial registered on ClinicalTrials.gov under registration number; NCT06120868:07/11/2023.

2.
Dent Mater ; 40(5): 869-877, 2024 May.
Article in English | MEDLINE | ID: mdl-38609774

ABSTRACT

OBJECTIVES: This 3D finite element analysis study aimed to investigate the effect of reinforcing CAD-CAM bars on stress distribution in various components of a posterior composite bridge. METHODS: A virtual model mimicking the absence of an upper second premolar was created, featuring class II cavity preparations on the proximal surfaces of the adjacent abutment teeth surrounding the edentulous space. Five distinct finite element analysis (FEA) models were generated, each representing a CAD-CAM reinforcing bar material: 3-YTZP (IPS. emax ZirCAD MO; Zr), lithium disilicate (IPS e.max CAD; EX), nano-hybrid resin composite (Grandio Blocs; GB), Fibre-reinforced composite (Trilor; Tri), and polyetheretherketone (PEEK). A veneering resin composite was employed to simulate the replacement of the missing premolar (pontic). In the FEA, an axial force of 600 N and a transverse load of 20 N were applied at the center of the pontic. Subsequently, maximum von Mises (mvM) and maximum principal stresses (σmax) were computed across various components of the generated models. Additionally, shear stresses at the interface between the CAD-CAM bars and the veneering resin composite were determined. RESULTS: CAD-CAM materials with high modulus of elasticity, such as Zr and EX, exhibited the highest mvM stresses and shear stresses while transferring the lowest stress to the veneering resin composite in comparison to other materials. Conversely, PEEK demonstrated the lowest mvM stresses but produced the highest stresses within the veneering resin composite. There was a uniform distribution of mvM stresses in the remaining tooth structure among all groups, except for a noticeable elevation in the molar region of Zr and EX groups. SIGNIFICANCE: Reinforcing CAD-CAM bar materials with a high modulus of elasticity, such as Zr and EX, may result in debonding failures at the connector sites of posterior composite bridges. Conversely, GB, PEEK, and Tri have the potential to cause fracture failures at the connectors rather than debonding.


Subject(s)
Benzophenones , Composite Resins , Computer-Aided Design , Dental Stress Analysis , Finite Element Analysis , Polyethylene Glycols , Composite Resins/chemistry , Polyethylene Glycols/chemistry , Materials Testing , Humans , Dental Materials/chemistry , Ketones/chemistry , Biomechanical Phenomena , Polymers/chemistry , Dental Porcelain/chemistry , Dental Veneers , Imaging, Three-Dimensional
3.
J Adhes Dent ; 26(1): 53-64, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-38329120

ABSTRACT

PURPOSE: This study investigated and compared the bond strengths, microleakage, microgaps, and marginal adaptation of self-adhesive resin composites (SAC) to dentin with or without universal adhesives. MATERIALS AND METHODS: Dentin surfaces of 75 molars were prepared for shear and microtensile bond strength testing (SBS and µTBS). Silicon molds were used to build up direct restorations using the following materials to form 5 groups: 1. Surefil One; 2. Prime&Bond active Universal Adhesive + Surefil One; 3. Vertise Flow; 4. OptiBond Universal + Vertise Flow; 5. Scotchbond Universal + Filtek Z500 (control group). Bonded specimens were thermocycled 10,000x before being tested either for SBS or µTBS using a universal testing machine at a crosshead speed of 0.5 mm/min. Direct mesial and distal class-II cavities were created on 100 sound premolars, with the gingival margin of distal cavities placed below CEJ and restored according to the five groups. After thermocycling, microleakage scores were assessed following immersion of restored premolars in 2% methylene blue dye for 24 h, while marginal gaps and adaptation percentages were investigated on epoxy resin replicas under SEM at magnifications of 2000X and 200X, respectively. Results were statistically analyzed with parametric and non-parametric tests as applicable, with a level of significance set at α = 0.05. RESULTS: Bond strengths, microleakage scores, microgaps, and percent marginal adaptation of Surefil One and Vertise Flow were significantly (p < 0.001) inferior to the control group. Dentin preconditioning with universal adhesives significantly increased the study parameter outcomes of Surefil One and Vertise Flow, yet they were still significantly below the performance of the control group. CONCLUSION: Conventional resin composite outperformed the SAC whether applied solely or in conjunction with their corresponding universal adhesives.


Subject(s)
Dental Bonding , Resin Cements , Bisphenol A-Glycidyl Methacrylate/chemistry , Resin Cements/chemistry , Dentin-Bonding Agents/chemistry , Dental Restoration, Permanent/methods , Dental Cements , Dentin , Composite Resins/chemistry , Materials Testing
4.
Viral Immunol ; 36(4): 250-258, 2023 05.
Article in English | MEDLINE | ID: mdl-36847755

ABSTRACT

Severe respiratory involvement that follows a process of immune dysregulation and intense cytokine production remains to be the most dreaded complication of Coronavirus Disease-2019 (COVID-19) infection. The aim of this study was to analyze T lymphocyte subsets and natural killer (NK) lymphocytes in moderate and severe cases of COVID-19 infection and assess their significance in disease severity and prognosis. Twenty moderate cases and 20 severe cases of COVID-19 were studied and compared regarding blood picture, biochemical markers, T lymphocyte population subsets, and NK lymphocytes, which were determined by flow cytometric analysis. On analyzing the flow cytometric data of T lymphocyte cells and their subsets and NK cells in two groups of COVID-19 infection (one group moderate and the other severe cases), some immature NK lymphocyte relative and absolute counts were higher in the severe patients with worse outcome and death, while some mature NK lymphocyte relative and absolute counts were depressed in both groups. Also, interleukin (IL)-6 was significantly higher in severe cases when compared to moderate cases, and there was a positive significant correlation between immature NK lymphocyte relative and absolute counts and IL-6. There was no statistically significant difference between T lymphocyte subsets (T helper and T cytotoxic) with disease severity or outcome. Some immature NK lymphocyte subsets contribute to the widespread inflammatory response that complicates severe cases of COVID-19; therapeutic approaches directed to enhancing NK maturation or drugs that block NK cell inhibitory receptors have a potential role in controlling COVID-19 induced cytokine storm.


Subject(s)
COVID-19 , Humans , SARS-CoV-2 , T-Lymphocyte Subsets , Lymphocyte Subsets , Killer Cells, Natural , Lymphocyte Count , Interleukin-6
5.
Dent Mater ; 39(1): 57-69, 2023 01.
Article in English | MEDLINE | ID: mdl-36496258

ABSTRACT

OBJECTIVE: To investigate the effect of acidic media, including beverages and gastric fluids on flexural strength and fatigue of CAD-CAM materials. METHODS: Four CAD-CAM materials (high-translucency zirconia (Ceramill Zolid HT+), lithium disilicate (IPS e-max CAD), hybrid ceramic (Vita Enamic), and nanohybrid resin composite (Grandio Blocs) were prepared and immersed in one of five media (gastric HCl, white wine, Coca-Cola, orange juice, and artificial saliva) in an incubator (37 â„ƒ, 24 h). Surface topography and roughness were obtained using a scanning electron microscope (SEM) and a stylus contact profilometer, respectively. Initial 3-point flexural strength was measured for half of the bars (n = 20/gp) using a universal testing machine (0.5 mm/min). The other bars underwent 106 cyclic fatigue loadings before measurement of residual 3-point flexural strength. Data were statistically analyzed (two-way and three-way ANOVA, Tukey's post-hoc, p < 0.05). Weibull distributions were plotted for reliability analysis. RESULTS: Zirconia bars has the highest initial flexural strengths followed by lithium disilicate, while resin composite and hybrid ceramic groups had the lowest strength regardless of the erosive medium. Cyclic fatigue significantly reduced initial flexural strengths for all materials except for hybrid ceramic and resin composite. Weibull moduli were the highest for zirconia, lithium disilicate and resin composite and lowest for hybrid ceramic. SIGNIFICANCE: Erosive media significantly changed surface roughness of CAD-CAM materials except for zirconia and resin composite without jeopardizing the flexural strength of the CAD-CAM materials. Despite the higher flexural strengths for zirconia and lithium disilicate, resin composite and hybrid ceramic were more resistant to cyclic fatigue.


Subject(s)
Dental Materials , Flexural Strength , Reproducibility of Results , Materials Testing , Surface Properties , Dental Porcelain , Ceramics , Computer-Aided Design
6.
J Evid Based Dent Pract ; 22(4): 101725, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36494113

ABSTRACT

OBJECTIVES: to evaluate the efficacy of 2 types of bioactive glass (45S5) compared to casein-phosphopeptide stabilized-amorphous calcium phosphate (CPP-ACP) in the treatment of orthodontically-induced white spot lesions (WSLs). METHODS: Sixty post-orthodontic WSLs (ICDAS II score 2) were randomly allocated to a double blind randomized controlled trial with 3 parallel arms (n = 20). Test group I (Bio-BAG) received BiominF slurry and toothpaste, and test group II (N-BAG) received Novamin slurry and toothpaste. While the positive control group (CPP-ACP) received Recaldent paste. Products were applied daily in-office during week 1, and boosted by self-administered home application for 4 weeks (week 1-4). Standard oral hygiene care was performed by all participants twice daily during months 2-6. All patients were assessed for change in WSL dimensions using computer assisted analysis based on standardized digital intraoral photographs in addition to laser fluorescence DIAGNOdent assessment before treatment (T0) and at 1 week (T1), 1 month (T2), 3 months (T3,) and 6 months (T4) follow up periods. RESULTS: Kruskal Wallis test was used (P < .05 for all). At T4, a statistically significant (P < .001) regression of WSL was disclosed in all 3 groups compared to baseline, and a highly significant lesion size percent reduction in Bio-BAG group compared to the control group (P < .001). The mean area of the lesions decreased by 64.8%, 32.2%, and 31.6% for groups I, II and III respectively (P = .001). DIAGNOdent findings largely reflected the clinical scores (Mean scores at baseline/T4 for groups I, II, and III respectively; 16.57/3.62, 16.93/7.90, 21.95/19.27). No adverse effects were reported. CONCLUSIONS: The combined in-office and home-application of BiominF paste for 4 weeks resulted in greater esthetic improvements of post-orthodontic WSLs compared to Novamin and CPP-ACP. In addition, BiominF showed a significant reduction in fluorescence intensity which indicates potential lesion remineralization. CLINICAL RELEVANCE: Post-orthodontic WSLs can be diminished using bioactive glass remineralization therapy.


Subject(s)
Dental Caries , Tooth Remineralization , Humans , Tooth Remineralization/methods , Cariostatic Agents/therapeutic use , Cariostatic Agents/pharmacology , Dental Caries/therapy , Dental Enamel , Toothpastes/therapeutic use , Toothpastes/pharmacology
7.
BMC Oral Health ; 22(1): 412, 2022 09 19.
Article in English | MEDLINE | ID: mdl-36123676

ABSTRACT

BACKGROUND: Mechanical surface treatments can deteriorate the mechanical properties of zirconia. This study evaluated and compared the biaxial flexural strength, fracture toughness, and fatigue resistance of high translucency (HT) to low translucency (LT) zirconia after various mechanical surface treatments. METHODS: Four hundred eighty zirconia discs were prepared by milling and sintering two HT (Katana and BruxZir) and LT (Cercon and Lava) zirconia blocks at targeted dimensions of 12 mm diameter × 1.2 mm thickness. Sintered zirconia discs received one of the following surface treatments: low-pressure airborne particle abrasion (APA) using 50 µm alumina particles, grinding using 400 grit silicon carbide paper, while as-sintered specimens served as control. Internal structure and surface roughness were evaluated by scanning electron microscope (SEM) and a non-contact laser profilometer, respectively. Half of the discs were tested for initial biaxial flexural strength, while the rest was subjected to 106 cyclic fatigue loadings, followed by measuring the residual biaxial flexural strength. Fractured surfaces were examined for critical size defects (c) using SEM to calculate the fracture toughness (KIC). The effect of surface treatments, zirconia type, and cyclic fatigue on the biaxial flexural strength was statistically analyzed using three-way analysis of variance (ANOVA) and Tukey HSD post hoc tests (α = 0.05). Weibull analysis was done to evaluate the reliability of the flexural strength for different materials. RESULTS: The initial biaxial flexural strength of LT zirconia was significantly higher (p < 0.001) than that of HT zirconia in all groups. While low APA significantly increased the biaxial flexural strength of LT zirconia, no significant change was observed for HT zirconia except for Katana. Surface grinding and cyclic fatigue significantly reduced the flexural strength of all groups. High translucency zirconia reported higher fracture toughness, yet with lower Weibull moduli, compared to LT zirconia. CONCLUSION: LT zirconia has higher biaxial flexural strength, yet with lower fracture toughness and fatigue resistance, compared to HT zirconia. Low-pressure APA has significantly increased the biaxial flexural strength in all zirconia groups except BruxZir. Grinding was deteriorating to biaxial flexural strength and fracture toughness in all zirconia types. Cyclic fatigue has significantly decreased the biaxial flexural strength and reliability of HT and LT zirconia.


Subject(s)
Aluminum Oxide , Flexural Strength , Humans , Materials Testing , Reproducibility of Results , Zirconium
8.
BMC Oral Health ; 22(1): 191, 2022 05 19.
Article in English | MEDLINE | ID: mdl-35590294

ABSTRACT

BACKGROUND: Erosive acids might create surface flaws and deteriorate the mechanical properties of CAD-CAM materials. This invitro study aimed to investigate the effect of simulated gastric HCl and extrinsic erosive acids on surface microhardness and fracture toughness of CAD-CAM materials. METHODS: 400 bar-shaped specimens (17×4×2 mm3) were prepared from 4 different CAD-CAM dental materials (n = 100/group); monolithic zirconia (Ceramill Zolid HT+, Amanngirbach, Austria), lithium disilicate ceramic (IPS e.max CAD, Ivoclar Vivadent, Liechtenstein), nanohybrid resin composite (Grandio Blocs, VOCO) and polymer-infiltrated glass network (Vita Enamic, VITA Zahnfabrik). Specimens from each material type were further subdivided into 5 groups (n = 20) according to the erosive media applied (simulated gastric HCl, white wine, Coca-Cola®, orange juice, and artificial saliva that served as a control). Specimens were immersed for 24 h in an incubator at 37 ℃, then ultrasonically cleaned in distilled water and air-dried. Half of the specimens were tested for Vickers microhardness (VHN) at parameters of 500 gf for 10 s, while the rest of the specimens underwent 3-point flexure till fracture. Fractured surfaces were examined under a scanning electron microscope (SEM) for fracture toughness (KIC) calculation using the quantitative fractographic analysis method. Data collected were statistically analyzed using two-way analysis of variance (α = 0.05) after verification of data normality and homogeneity of variances. RESULTS: Erosive media created surface flaws that lowered the surface microhardness of the material and initiated the fracture pattern under different loads according to material type. The material type was a more predominant factor than erosive media that affected either the microhardness or the fracture toughness of CAD-CAM dental materials. The highest VHN and KIC values were found among Ceramill Zolid HT+ groups followed by IPS e.max CAD and Grandio Blocs regardless of the erosive media employed. Erosive media significantly reduced the VHN and KIC in Vita Enamic specimens compared to the rest of the material types. CONCLUSION: All CAD-CAM materials used, except Vita Enamic, showed high resistance against the erosive acids indicating higher longevity of the material in patients frequently exposed to either extrinsic or intrinsic acid.


Subject(s)
Ceramics , Computer-Aided Design , Dental Materials , Humans , Materials Testing , Surface Properties
9.
Arab J Urol ; 20(1): 24-29, 2022.
Article in English | MEDLINE | ID: mdl-35223106

ABSTRACT

OBJECTIVES: To assess the efficacy and safety of high-dose tranexamic acid (TXA) during bipolar transurethral resection of the prostate (B-TURP) in patients with large prostates compared to placebo. PATIENTS AND METHODS: From February 2018 to May 2020, 204 patients with enlarged prostates of 80-130 g and in need of surgical intervention were randomised into two groups. Patients in Group A underwent B-TURP and received TXA as an intravenous loading dose of 50 mg/kg over 20 min before induction of anaesthesia followed by a maintenance infusion of 5 mg/kg/h until resection was completed. The patients in Group B (placebo) received a saline infusion of a similar volume. RESULTS: There was highly significant drop in haemoglobin in the placebo group at 4- and 24-h postoperatively compared with the TXA group (P < 0.001). However, there was no significant difference in the blood transfusion rate between the two groups with five patients (5.5%) in the placebo group and four (4.2%) in the TXA group requiring a transfusion (P = 0.74). The procedural time was significantly less in the TXA group vs the control group, at a mean (SD) of 79.93 (22.18) vs 90.91 (21.4) min (P = 0.001). Also, the intraoperative irrigation fluid volume and postoperative irrigation duration were significantly less in the TXA group vs the control group, at a mean (SD) of 19.21 (3.13) vs 23.05 (3.8) L and 14.75 (5.15) vs 18.33 (5.96) h, respectively (P = 0.001). Catheterisation and hospital stay durations were comparable between both groups (P = 0.384 and P = 0.388, respectively). No complications were recorded with use of high-dose TXA. CONCLUSION: High-dose TXA was effective in controlling blood loss during B-TURP in patients with large prostates, with no adverse drug reactions.

10.
Int J Dent ; 2021: 4593131, 2021.
Article in English | MEDLINE | ID: mdl-34335770

ABSTRACT

AIM: The aim of this study was to compare the microshear bond strength of ceramic veneers with digital die spacer settings at 20, 40, and 100 µm. MATERIALS AND METHODS: Eighteen milled lithium disilicate microdiscs (IPS e.max CAD, Ivoclar Vivadent) were divided into three groups (n = 6) according to their digital die spacer settings: group A = 20 µm, group B = 40 µm, and group C = 100 µm. Six randomly selected sound maxillary premolars received three microdiscs each. Each microdisc was 1 mm in diameter and 1 mm in height. The buccal surfaces of the premolars were prepared with a 0.5 mm depth in enamel. After cementation, the specimens were thermocycled for 2,500 cycles between 5 and 55°C. Microshear bond strength testing was performed using a universal testing machine until bonding failure. Failure modes were evaluated using a stereomicroscope. Statistical analyses included one-way ANOVA, Tukey's post hoc test, and chi-square test with a 5% alpha error and 80% study power. RESULTS: The mean microshear bond strength values were calculated in MPa for group A = 31.91 ± 12.41, group B = 29.58 ± 5.03, and group C = 13.85 ± 4.12. One-way ANOVA (p ≤ 0.05) showed a statistically significant difference in microshear bond strength among the three groups. Tukey's post hoc test showed significant differences between groups A and C (p=0.004) and between groups B and C (p=0.011). The failure modes were presented as cohesive, adhesive, and mixed failures. Chi-square test indicated that the failure mode distribution was not significantly different among the three groups (p=0.970). CONCLUSION: Higher digital die spacer settings decrease the microshear bond strength of CAD/CAM lithium disilicate veneers.

11.
Clin Cosmet Investig Dent ; 13: 223-230, 2021.
Article in English | MEDLINE | ID: mdl-34135638

ABSTRACT

OBJECTIVE: The purpose of this study was to compare the fracture resistance of ceramic veneers with digital die spacer settings at 20 µm, 40 µm, and 100 µm. MATERIALS AND METHODS: Eighteen sound maxillary first premolars were divided into three groups (n=6) according to their digital die spacer settings: group A=20 µm, group B=40 µm, group C=100 µm. Each tooth was prepared to a depth of 0.5 mm to receive lithium disilicate veneers (IPS e.max CAD, Ivoclar Vivadent). All groups were thermocycled (2500 cycles at 5-55°C) and subjected to fracture resistance test using a universal testing machine until failure. Failure modes were examined using a stereomicroscope. RESULTS: The values (N) for group A=1181.34±301.33, group B=1014.29±291.12, and group C=841.89±244.59. One-way ANOVA showed no statistical difference among the three groups (p=0.145). However, chi-square test showed that a significant difference was present in the modes of failure (p=0.009). Tukey's post hoc test indicated that the failure modes of group A were statistically different from those of group C, showing 83.3% adhesive failure for group A compared to 0% adhesive failures in group C. A p-value of ≤0.05 was considered as statistically significant. CONCLUSION: Digital die spacer thickness did not influence the mean fracture resistance values of CAD/CAM lithium disilicate veneers. However, the way the failure occurred differed significantly at various die spacer thicknesses.

SELECTION OF CITATIONS
SEARCH DETAIL
...