Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
Rev Sci Instrum ; 87(11): 11E536, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910584

ABSTRACT

A new technique for fitting the full radial profiles of electron density and temperature obtained by the Thomson scattering diagnostic in H-mode discharges on the COMPASS tokamak is described. The technique combines the conventionally used modified hyperbolic tangent function for the edge transport barrier (pedestal) fitting and a modification of a Gaussian function for fitting the core plasma. Low number of parameters of this combined function and their straightforward interpretability and controllability provide a robust method for obtaining physically reasonable profile fits. Deconvolution with the diagnostic instrument function is applied on the profile fit, taking into account the dependence on the actual magnetic configuration.

2.
Rev Sci Instrum ; 87(4): 043510, 2016 04.
Article in English | MEDLINE | ID: mdl-27131677

ABSTRACT

The ball-pen probe (BPP) technique is used successfully to make profile measurements of the electron temperature on the ASDEX Upgrade (Axially Symmetric Divertor Experiment), COMPASS (COMPact ASSembly), and ISTTOK (Instituto Superior Tecnico TOKamak) tokamak. The electron temperature is provided by a combination of the BPP potential (ΦBPP) and the floating potential (Vfl) of the Langmuir probe (LP), which is compared with the Thomson scattering diagnostic on ASDEX Upgrade and COMPASS. Excellent agreement between the two diagnostics is obtained for circular and diverted plasmas and different heating mechanisms (Ohmic, NBI, ECRH) in deuterium discharges with the same formula Te = (ΦBPP - Vfl)/2.2. The comparative measurements of the electron temperature using BPP/LP and triple probe (TP) techniques on the ISTTOK tokamak show good agreement of averaged values only inside the separatrix. It was also found that the TP provides the electron temperature with significantly higher standard deviation than BPP/LP. However, the resulting values of both techniques are well in the phase with the maximum of cross-correlation function being 0.8.

3.
Rev Sci Instrum ; 85(11): 11E431, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430338

ABSTRACT

The core Thomson scattering diagnostic (TS) on the COMPASS tokamak was put in operation and reported earlier. Implementation of edge TS, with spatial resolution along the laser beam up to ∼1/100 of the tokamak minor radius, is presented now. The procedure for spatial calibration and alignment of both core and edge systems is described. Several further upgrades of the TS system, like a triggering unit and piezo motor driven vacuum window shutter, are introduced as well. The edge TS system, together with the core TS, is now in routine operation and provides electron temperature and density profiles.

4.
Rev Sci Instrum ; 83(10): 10E327, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126985

ABSTRACT

COMPASS tokamak shots at low magnetic field feature overdense plasmas during the extended current flat-top phase. The first harmonic of the electron cyclotron emission is completely cutoff for O and X modes and so the emission caused by electron Bernstein waves (EBWs) propagating obliquely with respect to the magnetic field and undergoing so called EBW-X-O conversion process can be observed. We perform an angular scan of the EBW emission during a set of comparable shots in order to determine the optimum antenna direction. A weak dependence of the radiative temperature on the antenna angles indicates an influence of multiple reflections from the vessel wall. The low temperature at the mode conversion region is responsible for the collisional damping of EBW, which can explain several times lower measured radiative temperature than the electron temperature measured by the Thomson scattering system.

5.
Rev Sci Instrum ; 83(10): 10E350, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23127007

ABSTRACT

The electron density and temperature profiles measured by the Thomson scattering diagnostic on the COMPASS tokamak are used for estimation of electron kinetic energy, energy confinement time, and effective charge number Z(eff). Data are compared with the line-integrated electron density measured by a microwave interferometer in an ohmically heated plasma with a circular cross section. An error analysis of both electron temperature and density are performed by two methods-a constant chi-square boundaries method and a Monte Carlo simulation, determining asymmetrical error bars for the electron temperature.

6.
Rev Sci Instrum ; 81(10): 10D511, 2010 Oct.
Article in English | MEDLINE | ID: mdl-21033866

ABSTRACT

A new Thomson scattering diagnostic has been designed and is currently being installed on the COMPASS tokamak in IPP Prague in the Czech Republic. The requirements for this system are very stringent with approximately 3 mm spatial resolution at the plasma edge. A critical part of this diagnostic is the laser source. To achieve the specified parameters, a multilaser solution is utilized. Two 30 Hz 1.5 J Nd:YAG laser systems, used at the fundamental wavelength of 1064 nm, are located outside the tokamak area at a distance of 20 m from the tokamak. The design of the laser beam transport path is presented. The approach leading to a final choice of optimal focusing optics is given. As well as the beam path to the tokamak, a test path of the same optical length was built. Performance tests of the laser system carried out using the test path are described.

7.
Rev Sci Instrum ; 81(10): 10D531, 2010 Oct.
Article in English | MEDLINE | ID: mdl-21033886

ABSTRACT

A new Thomson scattering diagnostic system has been designed and is being built now on the COMPASS tokamak at the Institute of Plasma Physics ASCR in Prague (IPP Prague) in the Czech Republic. This contribution focuses on design, development, and installation of the light collection and detection system. High spatial resolution of 3 mm will be achieved by a combination of design of collection optics and connected polychromators. Imaging characteristics of both core and edge plasma collection objectives are described and fiber backplane design is presented. Several calibration procedures are discussed. The operational deployment of the Thomson scattering diagnostic is planned by the end of 2010.

9.
Percept Mot Skills ; 32(3): 881-2, 1971 Jun.
Article in English | MEDLINE | ID: mdl-5557028
10.
Multivariate Behav Res ; 4(4): 459-81, 1969 Oct 01.
Article in English | MEDLINE | ID: mdl-26804657

ABSTRACT

This study investigated the factorial composition of brain damage tests selected on the basis of a comprehensive review of the test literature. The tests were administered to 100 normal persons between the ages of 16 and 70. Two analyses were performed. The first analysis concerned the determi- nation of the factorial composition of the brain damage tests selected. The results suggested that although the dimensionality of the brain damage test battery is relatively complex, the majority of the tests discriminate on the basis of a few dimensions, at least for normal persons. The second analysis involved the determination of factor scores for each individual on the twelve factors extracted in the 16-70 age group analysis. An analysis of the factor scores as a function of age indicated a significant difference for only two of the factors. This finding was discussed in terms of the possibility that certain of the tests would be psychometrically more efficient in differential diagnosis of brain damage in the older person.

SELECTION OF CITATIONS
SEARCH DETAIL
...