Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Biochem ; 118: 110589, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37236295

ABSTRACT

BACKGROUND: Hemoglobinopathies include thalassemia syndromes, where production of one or more globin subunits of hemoglobin (Hb) is reduced, and structural Hb variants. Over 1000 disorders of Hb synthesis and/or structure have been identified and characterized, with phenotypes ranging from having severe clinical manifestations to clinically silent. Various analytical methods are used to phenotypically detect Hb variants. However, molecular genetic analysis is a more definitive method for Hb variant identification. CASE REPORT: Here, we report a case of a 23-month-old male with results from capillary electrophoresis, gel electrophoresis (acid and alkaline), and high-performance liquid chromatography most consistent with HbS trait. Specifically, capillary electrophoresis showed slightly elevated HbF and HbA2, HbA of 39.4% and HbS of 48.5%. The HbS percentage was consistently higher than expected (typically 30-40%) for HbS trait with no concurrent thalassemic indices. The patient has not experienced any clinical complications due to the hemoglobinopathy and he is thriving. CONCLUSION: Molecular genetic analysis revealed the presence of compound heterozygosity for HbS and Hb Olupona. Hb Olupona is an extremely rare beta-chain variant that appears as HbA on all three common methods used for phenotypic Hb analysis. When the fractional concentration of Hb variants is unusual, more definitive methods should be used, such as mass spectrometry or molecular genetic testing. In this case, incorrectly reporting this result as HbS trait is unlikely to have a significant clinical impact, as current evidence suggests Hb Olupona is not a clinically significant variant.


Subject(s)
Hemoglobinopathies , Hemoglobins, Abnormal , Thalassemia , Male , Humans , Hemoglobins, Abnormal/genetics , Hemoglobinopathies/diagnosis , Hemoglobinopathies/genetics , Thalassemia/genetics , Hemoglobin A2 , Electrophoresis, Capillary/methods
2.
Clin Biochem ; 116: 105-112, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37100108

ABSTRACT

OBJECTIVES: Multiple sclerosis is diagnosed based on clinical and laboratory findings, including cerebrospinal fluid (CSF) oligoclonal banding (OCB) analysis. The lack of updated CSF OCB laboratory guidelines in Canada has likely led to variation in processes and reporting across clinical laboratories. As a first step to developing harmonized laboratory recommendations, we examined current CSF OCB processes, reporting, and interpretation across all Canadian clinical laboratories currently performing this test. DESIGN AND METHODS: A survey of 39 questions was sent to clinical chemists at all 13 Canadian clinical laboratories performing CSF OCB analysis. The survey included questions regarding quality control processes, reporting practices for CSF gel electrophoresis pattern interpretation, and associated tests and calculated indices. RESULTS: The survey response rate was 100%. Most (10/13) laboratories use ≥2 CSF-specific bands (2017 McDonald Criteria) as their CSF OCB positivity cut-off and only 2/13 report the number of bands with every report. Most (8/13 and 9/13) laboratories report an inflammatory response pattern and monoclonal gammopathy pattern, respectively. However, the process for reporting and/or confirming a monoclonal gammopathy varies widely. Variation was observed for reference intervals, units, and the panel of reported associated tests and calculated indices. The maximum acceptable time interval between paired CSF and serum collections varied from 24 h to no limit. CONCLUSIONS: Profound variation exists in processes, reporting, and interpretation of CSF OCB and associated tests and indices across Canadian clinical laboratories. Harmonization of CSF OCB analysis is required to ensure continuity and quality of patient care. Our detailed assessment of current practice variation highlights the need for clinical stakeholder engagement and further data analysis to support optimal interpretation and reporting practices, which will aid in developing harmonized laboratory recommendations.


Subject(s)
Monoclonal Gammopathy of Undetermined Significance , Multiple Sclerosis , Paraproteinemias , Humans , Laboratories, Clinical , Canada , Oligoclonal Bands , Multiple Sclerosis/diagnosis , Multiple Sclerosis/cerebrospinal fluid
SELECTION OF CITATIONS
SEARCH DETAIL
...