Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Oral Oncol ; 157: 106944, 2024 Jul 17.
Article in English | MEDLINE | ID: mdl-39024700

ABSTRACT

OBJECTIVES: We describe the development of 3D-printed stents using our digital workflow and their effects on patients enrolled in the lead-in phase of a multi-center, randomized Phase-II trial. MATERIALS AND METHODS: Digital dental models were created for patients using intraoral scanning. Digital processes were implemented to develop the mouth-opening, tongue-depressing, and tongue-lateralizing stents using stereolithography. Time spent and material 3D-printing costs were measured. Physicians assessed mucositis using the Oral Mucositis Assessment Scale (OMAS) and collected MD Anderson Symptom Inventory (MDASI) reports and adverse events (AEs) from patients at various time points (TPs). OMAS and MDASI results were evaluated using paired t-test analysis. RESULTS: 18 patients enrolled into the lead-in phase across 6 independent clinical sites in the USA. 15 patients received stents (average design and fabrication time, 8 h; average material 3D-printing cost, 11 USD). 10 eligible patients with complete OMAS and MDASI reports across all TPs were assessed. OMAS increased significantly from baseline to week 3 of treatment (mean difference = 0.34; 95 % CI, 0.09-0.60; p = 0.01). MDASI increased significantly from baseline to week 3 of treatment (mean difference = 1.02; 95 % CI, 0.40-1.70; p = 0.005), and week 3 of treatment to end of treatment (mean difference = 1.90; 95 % CI, 0.90-2.92; p = 0.002). AEs (grades 1-3) were reported by patients across TPs. Mucositis and radiation dermatitis were primarily attributed to chemoradiation. CONCLUSIONS: 3D-printed stents were successfully fabricated and well tolerated by patients. As patients enroll in the randomized phase of this trial, data herein will establish a baseline for comparative analysis.

2.
Int J Radiat Oncol Biol Phys ; 114(1): 163-172, 2022 09 01.
Article in English | MEDLINE | ID: mdl-35643254

ABSTRACT

PURPOSE: The benefit of radiation therapy for pancreatic ductal adenocarcinoma (PDAC) remains unclear. We hypothesized that a new mechanistic mathematical model of chemotherapy and radiation response could predict clinical outcomes a priori, using a previously described baseline measurement of perfusion from computed tomography scans, normalized area under the enhancement curve (nAUC). METHODS AND MATERIALS: We simplified an existing mass transport model that predicted cancer cell death by replacing previously unknown variables with averaged direct measurements from randomly selected pathologic sections of untreated PDAC. This allowed using nAUC as the sole model input to approximate tumor perfusion. We then compared the predicted cancer cell death to the actual cell death measured from corresponding resected tumors treated with neoadjuvant chemoradiation in a calibration cohort (n = 80) and prospective cohort (n = 25). After calibration, we applied the model to 2 separate cohorts for pathologic and clinical associations: targeted therapy cohort (n = 101), cetuximab/bevacizumab + radiosensitizing chemotherapy, and standard chemoradiation cohort (n = 81), radiosensitizing chemotherapy to 50.4 Gy in 28 fractions. RESULTS: We established the relationship between pretreatment computed v nAUC to pathologically verified blood volume fraction of the tumor (r = 0.65; P = .009) and fractional tumor cell death (r = 0.97-0.99; P < .0001) in the calibration and prospective cohorts. On multivariate analyses, accounting for traditional covariates, nAUC independently associated with overall survival in all cohorts (mean hazard ratios, 0.14-0.31). Receiver operator characteristic analyses revealed discrimination of good and bad prognostic groups in the cohorts with area under the curve values of 0.64 to 0.71. CONCLUSIONS: This work presents a new mathematical modeling approach to predict clinical response from chemotherapy and radiation for PDAC. Our findings indicate that oxygen/drug diffusion strongly influences clinical responses and that nAUC is a potential tool to select patients with PDAC for radiation therapy.


Subject(s)
Carcinoma, Pancreatic Ductal , Pancreatic Neoplasms , Calibration , Carcinoma, Pancreatic Ductal/diagnostic imaging , Carcinoma, Pancreatic Ductal/radiotherapy , Humans , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/pathology , Pancreatic Neoplasms/therapy , Prospective Studies , Pancreatic Neoplasms
3.
Pancreatology ; 21(1): 200-207, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33221151

ABSTRACT

OBJECTIVES: Tumor size measurement is critical for accurate tumor staging in patients with pancreatic ductal adenocarcinoma (PDAC). However, accurate tumor size measurement is challenging in patients who received neoadjuvant therapy before resection, due to treatment-induced fibrosis and tumor invasion beyond the grossly identified tumor area. In this study, we evaluated the correlation between the tumor size and tumor volume measured on post-therapy computed tomography (CT) scans and the pathological measurement. Also, we investigated the correlation between these measurements and clinicopathological parameters and survival. MATERIALS AND METHODS: Retrospectively, we evaluated 343 patients with PDAC who received neoadjuvant therapy, followed by pancreaticoduodenectomy and had pre-operative pancreatic protocol CT imaging. We measured the longest tumor diameter (RadL) and the radiological tumor volume (RadV) on the post-therapy CT scan, then we categorized RadL into four radiologic tumor stages (RTS) based on the current AJCC staging (8th edition) protocol and RadV based on the median. Pearson correlation or Spearman's coefficient (δ), T-test and ANOVA was used to test the correlation between the radiological and pathological measurement. Chi-square analysis was used to test the correlation with the tumor pathological response, lymph-node metastasis and margin status and Kaplan-Meier and Cox-proportional hazard for survival analysis. P-value < 0.05 was considered significant. RESULTS: As a continuous variable, RadL showed a positive linear correlation with the post-therapy pathologic tumor size in the overall patient population (Pearson correlation coefficient: 0.72, P < 0.001) and RadV (δ: 0.63, p < 0.0001). However, there was no correlation between RadL and pathologic tumor size in patients with ypT0 and those with pathologic tumor size of ≤1.0 cm. Post-therapy RTS and RadV group correlated with ypT stage, tumor response grades using either CAP or MDA grading system, distance of superior mesenteric artery margin and tumor recurrence/metastasis. CONCLUSION: Although RadL tends to understage ypT in PDAC patients who had no radiologically detectable tumor or small tumors (RTS0 or RTS1), radiologic measurement of post-therapy tumor size may be used as a marker for the pathologic tumor staging and tumor response to neoadjuvant therapy.


Subject(s)
Carcinoma, Pancreatic Ductal/diagnostic imaging , Pancreatic Neoplasms/diagnostic imaging , Adult , Aged , Aged, 80 and over , Carcinoma, Pancreatic Ductal/mortality , Carcinoma, Pancreatic Ductal/therapy , Disease-Free Survival , Female , Humans , Kaplan-Meier Estimate , Lymphatic Metastasis , Male , Middle Aged , Neoadjuvant Therapy , Neoplasm Staging , Pancreatic Neoplasms/mortality , Pancreatic Neoplasms/therapy , Pancreaticoduodenectomy , Retrospective Studies , Survival Analysis , Tomography, X-Ray Computed , Treatment Outcome
4.
Oral Oncol ; 106: 104665, 2020 07.
Article in English | MEDLINE | ID: mdl-32298994

ABSTRACT

BACKGROUND AND PURPOSE: Customized mouth-opening-tongue-depressing-stents (MOTDs) may reduce toxicity in patients with head and neck cancers (HNC) receiving radiotherapy (RT). However, making MOTDs requires substantial resources, which limits their utilization. Previously, we described a workflow for fabricating customized 3D-printed MOTDs. This study reports the results of a prospective trial testing the non-inferiority of 3D-printed to standard and commercially-available (TruGuard) MOTDs as measured by patient reported outcomes (PROs). MATERIALS AND METHODS: PROs were collected at 3 time points: (t1) simulation, (t2) prior to RT, (t3) between fractions 15-25 of RT. Study participants received a 3D-printed MOTDs (t1, t2, t3), a wax-pattern (t1), an acrylic-MOTDs (t2, t3) and an optional TruGuard (t1, t2, t3). Patients inserted the stents for 5-10 min and completed a PRO-questionnaire covering ease-of-insertion and removal, gagging, jaw-pain, roughness and stability. Inter-incisal opening and tongue-displacement were recorded. With 39 patients, we estimated 90% power to detect a non-inferiority margin of 2 at a significance level of 0.025. Matched pairs and t-test were used for statistics. RESULTS: 41 patients were evaluable. The 3D-printed MOTDs achieved a significantly better overall PRO score compared to the wax-stent (p = 0.0007) and standard-stent (p = 0.0002), but was not significantly different from the TruGuard (p = 0.41). There was no difference between 3D-printed and standard MOTDs in terms of inter-incisal opening (p = 0.4) and position reproducibility (p = 0.98). The average 3D-printed MOTDs turn-around time was 8 vs 48 h for the standard-stent. CONCLUSIONS: 3D-printed stents demonstrated non-inferior PROs compared to TruGuard and standard-stents. Our 3D-printing process may expand utilization of MOTDs.


Subject(s)
Head and Neck Neoplasms/surgery , Printing, Three-Dimensional/instrumentation , Stents/standards , Adult , Aged , Female , Head and Neck Neoplasms/radiotherapy , Humans , Male , Middle Aged , Prospective Studies
5.
Drug Deliv ; 21(2): 148-54, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24128122

ABSTRACT

The central nervous system (CNS) is an immunological privileged sanctuary site-providing reservoir for HIV-1 virus. Current anti-HIV drugs, although effective in reducing plasma viral levels, cannot eradicate the virus completely from the body. The low permeability of anti-HIV drugs across the blood-brain barrier (BBB) leads to insufficient delivery. Therefore, developing a novel approaches enhancing the CNS delivery of anti-HIV drugs are required for the treatment of neuro-AIDS. The aim of this study was to develop intranasal nanoemulsion (NE) for enhanced bioavailability and CNS targeting of saquinavir mesylate (SQVM). SQVM is a protease inhibitor which is a poorly soluble drug widely used as antiretroviral drug, with oral bioavailability is about 4%. The spontaneous emulsification method was used to prepare drug-loaded o/w nanoemulsion, which was characterized by droplet size, zeta potential, pH, drug content. Moreover, ex-vivo permeation studies were performed using sheep nasal mucosa. The optimized NE showed a significant increase in drug permeation rate compared to the plain drug suspension (PDS). Cilia toxicity study on sheep nasal mucosa showed no significant adverse effect of SQVM-loaded NE. Results of in vivo biodistribution studies show higher drug concentration in brain after intranasal administration of NE than intravenous delivered PDS. The higher percentage of drug targeting efficiency (% DTE) and nose-to-brain drug direct transport percentage (% DTP) for optimized NE indicated effective CNS targeting of SQVM via intranasal route. Gamma scintigraphy imaging of the rat brain conclusively demonstrated transport of drug in the CNS at larger extent after intranasal administration as NE.


Subject(s)
Brain/metabolism , Drug Delivery Systems/methods , Nanoparticles/metabolism , Nasal Mucosa/metabolism , Saquinavir/metabolism , Administration, Intranasal , Animals , Blood-Brain Barrier/drug effects , Blood-Brain Barrier/metabolism , Brain/drug effects , Emulsions , Male , Nanoparticles/administration & dosage , Nasal Mucosa/drug effects , Rats , Rats, Sprague-Dawley , Saquinavir/administration & dosage , Sheep
6.
J Mater Sci Mater Med ; 23(9): 2163-75, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22802103

ABSTRACT

The present investigation deals with the development and statistical optimization of solid lipid nanoparticles (SLNs) of ondansetron HCl (OND) for intranasal (i.n.) delivery. SLNs were prepared using the solvent diffusion technique and a 2(3) factorial design. The concentrations of lipid, surfactant and cosurfactant were independent variables in this design, whereas, particle size and entrapment efficiency (EE) were dependent variables. The particle size of the SLNs was found to be 320-498 nm, and the EE was between 32.89 and 56.56 %. The influence of the lipid, surfactant and cosurfactant on the particle size and EE was studied. A histological study revealed no adverse response of SLNs on sheep nasal mucosa. Transmission electron microscopic analysis showed spherical shape particles. Differential scanning calorimetry and X-ray diffraction studies indicated that the drug was completely encapsulated in a lipid matrix. In vitro drug release studies carried out in phosphate buffer (pH 6.6) indicated that the drug transport was of Fickian type. Gamma scintigraphic imaging in rabbits after i.n. administration showed rapid localization of the drug in the brain. Hence, OND SLNs is a promising nasal delivery system for rapid and direct nose-to-brain delivery.


Subject(s)
Chemistry, Pharmaceutical , Drug Delivery Systems , Lipids/chemistry , Nanoparticles/chemistry , Ondansetron/administration & dosage , Administration, Intranasal , Animals , Calibration , Calorimetry, Differential Scanning , Cells, Cultured , Chemistry, Pharmaceutical/methods , Chemistry, Pharmaceutical/standards , Drug Delivery Systems/methods , Drug Delivery Systems/standards , Lipids/chemical synthesis , Liposomes/chemical synthesis , Liposomes/chemistry , Materials Testing , Microscopy, Electron, Transmission , Rabbits , Sheep , X-Ray Diffraction
7.
Drug Deliv ; 18(5): 353-60, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21351825

ABSTRACT

In the present study, tramadol HCl microspheres were designed in order to accomplish rapid delivery of drug to the brain. For this purpose, lower viscosity grade HPMC (E15) was chosen as mucoadhesive polymer and used at different drug/polymer ratios in the microspheres formulations. The spray-dried microspheres were evaluated with respect to the production yield, incorporation efficiency, particle size, mucoadhesive property, in vitro drug release, histopathological study, and radio imaging study in rabbits. DSC and XRD study showed molecular dispersion and conversion of the drug into amorphous form. Size and surface morphology of microspheres was analyzed by SEM and found to be spherical in shape with smooth surface. It was found that the particle size, swelling ability, and incorporation efficiency of microspheres increase with increasing drug-to-polymer ratio. Microspheres show adequate mucoadhesion and do not have any destructive effect on nasal mucosa. In vitro drug release of optimized formulation was found to be 94% after 90 min. The radio imaging study indicated localization of drug in the brain. Hence, tramadol HCl microspheres based on a HPMC E15 may be a promising nasal delivery system for CNS targeting.


Subject(s)
Analgesics, Opioid/administration & dosage , Brain/metabolism , Drug Delivery Systems , Tramadol/administration & dosage , Adhesiveness , Administration, Intranasal , Analgesics, Opioid/pharmacokinetics , Animals , Excipients/chemistry , Hypromellose Derivatives , Methylcellulose/analogs & derivatives , Methylcellulose/chemistry , Microscopy, Acoustic , Microspheres , Nasal Mucosa/drug effects , Nasal Mucosa/metabolism , Particle Size , Rabbits , Tissue Distribution , Tramadol/pharmacokinetics
SELECTION OF CITATIONS
SEARCH DETAIL
...