1.
Ann Cardiol Angeiol (Paris) ; 68(3): 187-194, 2019 Jun.
Article in French | MEDLINE | ID: mdl-30704626

ABSTRACT

Regular physical exercice has undeniable cardiovascular benefits and improves life expectancy. This benefice seems limited to moderate intensity exercises. Intense and chronic physical exercice would lead to heart structural changes. For a long time, knowledge of these cardiac effects seemed limited to the left ventricle. Since more authors have shown that right ventricle is vulnerability to the effects of intense chronic training. We report a Gallavardin-type ventricular stress tachycardia in a young with healthy hearted; in whom a right infundibular arrhythmogenic focus has been found in the absence of structural alteration of the right ventricle. Intense athletic activity may reveal a latent arrhythmogenic focus through sympathetic activation. Ablation was the preferred therapeutic strategy, preferred to drug therapy and derived from an analysis of risk-benefit ratios.


Subject(s)
Sports/physiology , Tachycardia, Ventricular/physiopathology , Adult , Arrhythmias, Cardiac/diagnosis , Electrocardiography , Exercise Test , Female , Humans
2.
Transfus Apher Sci ; 32(3): 305-13, 2005 Jun.
Article in English | MEDLINE | ID: mdl-15944117

ABSTRACT

The first protocol available for the new ALYX component system (Baxter Healthcare Inc.) allows automated collection of two Red Blood Cell (RBC) units from one donor. The primary objective of our evaluation was to assess donor safety, comfort and to check the quality of blood products collected. 30 procedures were performed on eligible donors according to French best donation practices. Eligibility criteria were defined in order to ensure a post donation hemoglobin concentration of 11 g/dL minimum. Pre donation ferritin level was also checked. 360 ml of absolute RBC were collected from each donor. Donors physiological parameters and haematological profile were measured immediately before and after donation. Adverse events and donors were observed during the procedure and followed daily during 5 days after donation. Hemolysis in RBC was followed until of shelf life (<0.8% on 42 days storage). The evaluation of different parameters during storage show no difference if we compare with the manual technique. The concentration of hemoglobin is good and all ou concentrates are conform. No serious adverse effects were reported during and after donation. All donors confirmed they would agree to donate 2 RBC units again with this system. We have seen a good quality of RBC products. This evaluation indicates that 2 RBC donation is feasible on the ALYX system, comfortable and safe for eligible donors.


Subject(s)
Erythrocytes , Leukapheresis/instrumentation , Leukapheresis/methods , Plasmapheresis/instrumentation , Plasmapheresis/methods , Adult , Female , Humans , Male , Middle Aged