Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Diabetes Technol Ther ; 16(3): 172-9, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24152323

ABSTRACT

OBJECTIVE: This study assessed the efficacy of a closed-loop (CL) system consisting of a predictive rule-based algorithm (pRBA) on achieving nocturnal and postprandial normoglycemia in patients with type 1 diabetes mellitus (T1DM). The algorithm is personalized for each patient's data using two different strategies to control nocturnal and postprandial periods. RESEARCH DESIGN AND METHODS: We performed a randomized crossover clinical study in which 10 T1DM patients treated with continuous subcutaneous insulin infusion (CSII) spent two nonconsecutive nights in the research facility: one with their usual CSII pattern (open-loop [OL]) and one controlled by the pRBA (CL). The CL period lasted from 10 p.m. to 10 a.m., including overnight control, and control of breakfast. Venous samples for blood glucose (BG) measurement were collected every 20 min. RESULTS: Time spent in normoglycemia (BG, 3.9-8.0 mmol/L) during the nocturnal period (12 a.m.-8 a.m.), expressed as median (interquartile range), increased from 66.6% (8.3-75%) with OL to 95.8% (73-100%) using the CL algorithm (P<0.05). Median time in hypoglycemia (BG, <3.9 mmol/L) was reduced from 4.2% (0-21%) in the OL night to 0.0% (0.0-0.0%) in the CL night (P<0.05). Nine hypoglycemic events (<3.9 mmol/L) were recorded with OL compared with one using CL. The postprandial glycemic excursion was not lower when the CL system was used in comparison with conventional preprandial bolus: time in target (3.9-10.0 mmol/L) 58.3% (29.1-87.5%) versus 50.0% (50-100%). CONCLUSIONS: A highly precise personalized pRBA obtains nocturnal normoglycemia, without significant hypoglycemia, in T1DM patients. There appears to be no clear benefit of CL over prandial bolus on the postprandial glycemia.


Subject(s)
Blood Glucose Self-Monitoring , Diabetes Mellitus, Type 1/drug therapy , Hypoglycemia/drug therapy , Hypoglycemic Agents/administration & dosage , Insulin Infusion Systems , Insulin/administration & dosage , Pancreas, Artificial , Algorithms , Blood Glucose/metabolism , Cross-Over Studies , Diabetes Mellitus, Type 1/blood , Diabetes Mellitus, Type 1/physiopathology , Female , Glycated Hemoglobin/metabolism , Humans , Hypoglycemia/metabolism , Hypoglycemia/physiopathology , Infusions, Subcutaneous , Male , Meals , Postprandial Period , Predictive Value of Tests , Reproducibility of Results , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...