Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Eye (Lond) ; 37(12): 2535-2541, 2023 08.
Article in English | MEDLINE | ID: mdl-36577805

ABSTRACT

OBJECTIVES: To determine 36-month efficacy and safety outcomes of the PRESERFLO Microshunt implant in the treatment of refractory uveitic glaucoma. METHODS: Consecutive patients with uncontrolled uveitic glaucoma despite maximum medical treatment received PRESERFLO Microshunt implant with mitomycin C (MMC) in a tertiary referral glaucoma practice. Efficacy and safety outcomes data were collected at month 6, 12, 24, and 36, postoperatively. The primary outcome was surgical success, defined as intraocular pressure (IOP) between 5 and 21 mmHg or > 20% reduction from baseline, and absence of criteria for surgical failure. Secondary outcomes were IOP, visual acuity (VA), use of glaucoma medical therapy, surgical complications, rate of reoperation for glaucoma. RESULTS: 21 eyes of 21 patients were included. The mean rate of success was 0.74 (95%CI 0.48-0.88), 0.68 (0.43-0.84), 0.47 (0.25-0.67), and 0.47 (0.25-0.67, at 6, 12, 24, and 36 months postoperatively, respectively. The mean IOP decreased by 30.7% (95% CI 13.7-47.7), 26.5% (95% CI 3.2-49.8), 33.5% (95% CI 21.8-45.3), and 30.1% (95% CI 7.2-52.9) from baseline at postoperative month 6, 12, 24, and 36, respectively (p < 0.001). The mean ± SD number of glaucoma medications decreased from 4.1 ± 0.9 to 0.9 ± 1.2 at the final follow up (p = 0.0005). No sight-threatening complications were reported by 36 months. CONCLUSIONS: Three-year results of the PRESERFLO Microshunt implant demonstrated favourable efficacy and safety profile in the treatment of refractory uveitic glaucoma.


Subject(s)
Glaucoma Drainage Implants , Glaucoma , Humans , Glaucoma Drainage Implants/adverse effects , Treatment Outcome , Glaucoma/etiology , Glaucoma/surgery , Intraocular Pressure , Tonometry, Ocular , Retrospective Studies
2.
Eye (Lond) ; 37(10): 2126-2129, 2023 07.
Article in English | MEDLINE | ID: mdl-36434286

ABSTRACT

BACKGROUND/OBJECTIVES: PRESERFLO MicroShunt implantation is a relatively new and increasingly popular treatment for recalcitrant glaucoma. Though relatively uncommon, persistent or severe postoperative hypotony may occur and its treatment presents a significant challenge. SUBJECTS/METHODS: Interventional case series of the first 7 consecutive patients who underwent the insertion of a rip-cord suture to treat severe or persistent postoperative hypotony. RESULTS: In 6 patients, the hypotony resolved and vision was restored. The 7th patient had suffered a severe suprachoroidal haemorrhage with a poor visual recovery and limited follow-up, so success was more difficult to assess. CONCLUSIONS: Stenting the PRESERFLO MicroShunt with a rip-cord suture is a simple technique to correct persistent or severe postoperative hypotony.


Subject(s)
Glaucoma Drainage Implants , Intraocular Pressure , Humans , Tonometry, Ocular , Glaucoma Drainage Implants/adverse effects , Prosthesis Implantation/methods , Treatment Outcome
4.
Ophthalmol Glaucoma ; 4(3): 295-304, 2021.
Article in English | MEDLINE | ID: mdl-33069883

ABSTRACT

PURPOSE: To establish whether deep learning methods are able to improve the signal-to-noise ratio of time-domain (TD) OCT images to approach that of spectral-domain (SD) OCT images. DESIGN: Method agreement study and progression detection in a randomized, double-masked, placebo-controlled, multicenter trial for open-angle glaucoma (OAG), the United Kingdom Glaucoma Treatment Study (UKGTS). PARTICIPANTS: The training and validation cohort comprised 77 stable OAG participants with TD OCT and SD OCT imaging at up to 11 visits within 3 months. The testing cohort comprised 284 newly diagnosed OAG patients with TD OCT images from a cohort of 516 recruited at 10 United Kingdom centers between 2007 and 2010. METHODS: An ensemble of generative adversarial networks (GANs) was trained on TD OCT and SD OCT image pairs from the training dataset and applied to TD OCT images from the testing dataset. Time-domain OCT images were converted to synthesized SD OCT images and segmented via Bayesian fusion on the output of the GANs. MAIN OUTCOME MEASURES: Bland-Altman analysis assessed agreement between TD OCT and synthesized SD OCT average retinal nerve fiber layer thickness (RNFLT) measurements and the SD OCT RNFLT. Analysis of the distribution of the rates of RNFLT change in TD OCT and synthesized SD OCT in the two treatment arms of the UKGTS was compared. A Cox model for predictors of time-to-incident visual field (VF) progression was computed with the TD OCT and the synthesized SD OCT images. RESULTS: The 95% limits of agreement were between TD OCT and SD OCT were 26.64 to -22.95; between synthesized SD OCT and SD OCT were 8.11 to -6.73; and between SD OCT and SD OCT were 4.16 to -4.04. The mean difference in the rate of RNFLT change between UKGTS treatment and placebo arms with TD OCT was 0.24 (P = 0.11) and with synthesized SD OCT was 0.43 (P = 0.0017). The hazard ratio for RNFLT slope in Cox regression modeling for time to incident VF progression was 1.09 (95% confidence interval [CI], 1.02-1.21; P = 0.035) for TD OCT and 1.24 (95% CI, 1.08-1.39; P = 0.011) for synthesized SD OCT. CONCLUSIONS: Image enhancement significantly improved the agreement of TD OCT RNFLT measurements with SD OCT RNFLT measurements. The difference, and its significance, in rates of RNFLT change in the UKGTS treatment arms was enhanced and RNFLT change became a stronger predictor of VF progression.


Subject(s)
Deep Learning , Glaucoma, Open-Angle , Bayes Theorem , Double-Blind Method , Glaucoma, Open-Angle/diagnosis , Humans , Tomography, Optical Coherence
5.
Semin Ophthalmol ; 33(2): 223-230, 2018.
Article in English | MEDLINE | ID: mdl-27628484

ABSTRACT

PURPOSE: To examine interrelations between corneal biomechanics, ocular biometric variables and optic disc size (ODS), lamina cribosa depth (LCD) or thickness (LCT) in a healthy population. MATERIAL AND METHODS: In a cross-sectional case-control study, the following measurements were made in 81 eyes of 81 participants: axial length, anterior chamber depth, lens thickness, and central corneal thickness using the optical biometer Lenstar LS900; and corneal hysteresis (CH), corneal resistance factor (CRF), Goldman-correlated intraocular pressure (IOPg), and corneal-compensated IOP (IOPcc) using the Ocular Response Analyzer. Serial horizontal enhanced depth imaging optical coherence tomography (EDI OCT) B-scans of the optic nerve head were obtained in each participant. Mean ODS, mean LCD, and mean LCT were measured in 11 equally spaced horizontal B-scans, excluding the LC insertion area under Bruch's membrane and scleral rim. RESULTS: LCD was measured in 74 of 81 eyes (91.36%); LCT in 60/81 (75.3%); ODS in 81/81 (100%). CRF was poorly, but significantly, correlated with LCT (Pearson's R = 0.264; P = 0.045). IOPcc, IOPg, CH, and ocular biometrics variables were poorly (non-significantly) correlated with LCD, LCT, and ODS. CONCLUSIONS: CRF was poorly but directly correlated with LCT. No association was detected between CH or ocular biometric variables and ODS, LCD, or LCT.


Subject(s)
Cornea/physiology , Intraocular Pressure/physiology , Optic Disk/diagnostic imaging , Visual Fields , Adult , Biometry , Case-Control Studies , Cornea/diagnostic imaging , Cross-Sectional Studies , Elasticity , Female , Healthy Volunteers , Humans , Male , Middle Aged , Tomography, Optical Coherence/methods , Tonometry, Ocular , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...