Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Language
Publication year range
1.
Rev. colomb. cardiol ; 23(4): 334-339, jul.-ago. 2016. ilus, tab
Article in Spanish | LILACS, COLNAL | ID: biblio-830304

ABSTRACT

Objetivo: Establecer la correlación y la concordancia del grado de severidad de insuficiencia pulmonar entre la ecocardiografía y la resonancia magnética en la población pediátrica de un hospital de tercer nivel de atención. Métodos: Se estudiaron 20 pacientes con diagnóstico de cardiopatía congénita con insuficiencia pulmonar, a quienes se les realizaron ecocardiograma transtorácico y resonancia magnética. Se calculó: relación de la vena contracta y el chorro de insuficiencia pulmonar, tiempo de hemipresión, presencia de flujo diastólico reverso en tronco pulmonar e índice de insuficiencia pulmonar; en cuanto a la resonancia magnética: la fracción y el volumen regurgitante. Se realizó análisis de correlación mediante coeficiente de correlación de Spearman y prueba de Tau B. Resultados:La tetralogía de Fallot corregida representó el 60% de la muestra. La correlación fue significativa en la fracción y el volumen regurgitante de la resonancia magnética, así como en las variables ecocardiográficas índice de insuficiencia pulmonar en modo M, vena contracta y porcentaje de vena contracta/arteria pulmonar. La correlación entre los grados de insuficiencia pulmonar por resonancia magnética y ecocardiografía fue 0,85 (p < 0,001). Conclusiones: La vena contracta y el porcentaje VC/AP son variables que tienen alta correlación con la fracción y el volumen regurgitante de la resonancia magnética nuclear para evaluar la insuficiencia pulmonar en pacientes en posoperatorio de cardiopatía congénita.


Motivation: To establish the correlation and concordance of the degree of severity of pulmonary insufficiency between echocardiography and magnetic resonance in pediatric population of a third level hospital. Methods: 20 patients diagnosed with congenital heart disease and with pulmonary insufficiency were studied, they underwent a transthoracic echocardiogram and a magnetic resonance. The relationship of the vena contracta, the pulmonary regurgitation jet, the pressure half-time time, the presence of reversed end-diastolic flow and the pulmonary insufficiency index were calculated. With regards to the magnetic resonance, both fraction and regurgitant volume were measured. An analysis of the correlation was conducted.by means of the Spearman correlation and the Tau B. Results: Corrected Fallot's tetralogy represented 60% of the sample. The correlation was significant in the fraction and the regurgitant volume of the magnetic resonance, as well as in the echocardiographic variables of M-mode pulmonary insufficiency, vena contracta and vena contracta/pulmonary artery percentage. The correlation between the degrees of pulmonary insufficiency by magnetic resonance and echocardiogram was 0.85 (p < 0.001). Conclusions: Vena contracta and the VC/PA percentage are variables that present high correlation with the fraction and the regurgitant volume of nuclear magnetic resonance to assess pulmonary insufficiency in patients after a congenital cardiac disease surgery.


Subject(s)
Humans , Echocardiography , Magnetic Resonance Imaging
2.
Rev Med Inst Mex Seguro Soc ; 52 Suppl 2: S62-7, 2014.
Article in Spanish | MEDLINE | ID: mdl-24983559

ABSTRACT

BACKGROUND: Congenital heart disease with decreased pulmonary flow survival has increased due to systemic pulmonary fistulae (SPF); nevertheless, complications may occur. The purpose of this study was to identify mortality-related surgical and biochemical factors in pediatric patients with modified Blalock-Taussig shunt. METHODS: A cohort was formed with congenital heart disease newborns who survived Blalock-Taussig-type palliative systemic pulmonary fistulae surgery. At admission to the intensive care unit, surgical time, diameter polytetrafluoroethylene vascular graft, arterial blood gases and central venous saturation were recorded. The patients were followed until discharge or death. For statistical analysis, central tendency and dispersion measures, chi-square tests, odds-ratios, Cox regression model and hazard ratios (HR) were used, and for the most independent variable, Kaplan-Meier curves. RESULTS: Out of 33 newborns who underwent the surgical procedure, 9 died (23%). The most common heart diseases were pulmonary atresia with intact ventricular septum (8 patients, 25%) and hypoplastic right ventricle (8, 25%). The most independent mortality-associated variable was hyperlactatemia > 3 mmol/L (HR = 8 [1.9 - 32], p < 0.05). CONCLUSIONS: Lactate > 3 mmol/L was an independent predictor of mortality in patients who underwent Blalock-Taussig shunt.


INTRODUCCIÓN: la supervivencia de los pacientes con cardiopatía congénita con flujo pulmonar disminuido ha aumentado debido a las técnicas de anastomosis quirúrgica entre la circulación sistémica y la pulmonar, sin embargo, pueden presentarse complicaciones. El objetivo de este estudio fue determinar los factores quirúrgicos y bioquímicos relacionados con la muerte en pacientes pediátricos en quienes se realizó derivación de Blalock-Taussig modificada. MÉTODOS: se integró una cohorte de neonatos con cardiopatía congénita sometidos a derivación tipo Blalock-Taussig que sobrevivieron a la cirugía. Al ingreso a cuidados intensivos se documentó tiempo quirúrgico, diámetro del injerto vascular de politetrafluoroetileno, gasometría arterial y saturación venosa central de oxígeno. Se dio seguimiento hasta el egreso o defunción. Para el análisis estadístico se utilizaron medidas de tendencia central y dispersión, chi cuadrada, razón de momios, modelo de regresión de Cox, hazard ratio (HR) y curva de Kaplan-Meier, para la variable más independiente. RESULTADOS: de 33 neonatos sometidos a procedimiento quirúrgico, nueve murieron (23 %). Las cardiopatías más frecuentes fueron la atresia pulmonar con septo íntegro (ocho, 25 %) y ventrículo derecho hipoplásico (ocho, 25 %). La variable más independiente relacionada con mortalidad lo constituyó el nivel del lactato sérico > 3 mmol/L (HR = 8 [1.9-32], p < 0.05). CONCLUSIONES: el nivel del lactato sérico > 3 mmol/L fue un predictor independiente de mortalidad en los pacientes con derivación tipo Blalock-Taussig.


Subject(s)
Blalock-Taussig Procedure/mortality , Child , Child, Preschool , Cohort Studies , Female , Humans , Infant , Infant, Newborn , Male , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...