Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
AAPS PharmSciTech ; 14(3): 1004-11, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23780781

ABSTRACT

Abbreviated impactors have been developed recently to allow more rapid evaluation of inhalation products as alternates to the eight-stage Andersen Cascade Impactor (ACI) which has been widely used in the pharmaceutical industry for assessing aerodynamic particle size distribution. In this paper, a two-stage abbreviated impactor, Westech Fine Particle Dose Impactor (WFPD), was used to characterize the aerodynamic particle size of metered dose inhaler (MDI) products, and the results were compared with those obtained using the standard eight-stage ACI. Seven commercial MDI products, with different propellants (chlorofluorocarbon/hydrofluoroalkane) and formulation types (suspension/solution, dry/normal/wet), were tested in this study by both WFPD and ACI. Substantially equivalent measures of fine particle fraction were obtained for most of the tested MDI products, but larger coarse particle fraction and extra-fine particle fraction values were measured from WFPD relative to those measured using the ACI. Use of the WFPD also produced more wall loss than the ACI. Therefore, it is recommended that the system suitability be evaluated on a product-by-product basis to establish substantial equivalency before implementing an abbreviated impactor measurement methodology for routine use in inhaler product characterization.


Subject(s)
Equipment Design , Metered Dose Inhalers , Administration, Inhalation , Particle Size
2.
J Pharm Sci ; 100(3): 1093-101, 2011 Mar.
Article in English | MEDLINE | ID: mdl-20803604

ABSTRACT

Dissolution testing of pharmaceutical products is an important technique used extensively for both product development and quality control, but there are many variables that can affect dissolution results. In this study, the effect of the inner shape of standard 1-L dissolution vessels on drug dissolution results was investigated. The geometric dimensions and irregularities of commercially available vessels (obtained from four different manufacturers) were examined using a three-dimensional video-based measuring machine (VMM). The same analyst, dissolution test assembly, and experimental conditions were used for dissolution testing involving 10 mg of prednisone tablets (NCDA #2) with dissolution apparatus 2 (paddle). Mechanical calibration of the dissolution apparatus was performed prior to dissolution testing with each set of vessels. Geometric characteristics varied within and among the sets of vessels, but the overall averages and standard deviations of dissolution results (six vessels) showed no statistical significant differences among the vessel sets. However, some dissolution differences were noted when comparing individual vessels. With these types of comparisons, the vessel concentricity, sphericity, and radius of sphere were found to possibly influence the amount of prednisone dissolved, but flatness of vessel flange, cylindricity, and circularity showed no effect on dissolution results. The study shows that VMM is a technique that could be used to qualify dissolution vessels.


Subject(s)
Chemistry, Pharmaceutical/instrumentation , Glucocorticoids/chemistry , Pharmaceutical Preparations/analysis , Pharmaceutical Preparations/chemistry , Prednisone/chemistry , Calibration , Pharmacopoeias as Topic , Quality Control , Solubility
SELECTION OF CITATIONS
SEARCH DETAIL
...