1.
Talanta ; 148: 101-7, 2016.
Article in English | MEDLINE | ID: mdl-26653429

ABSTRACT

An effective electrode was developed based on electromembrane extraction (EME) and square wave voltammetry (SWV) for simultaneous separation, pre-concentration and determination of lead (II) (Pb(II)) ions in complex aqueous samples. Electrochemically reduced graphene oxide-graphite reinforced carbon (ErGO-GRC) was utilized in conjunction with the SWV. Pb(II) ions were extracted from an aqueous sample solution into an acidic acceptor phase (1M HCl) in the lumen of the polyvinylidene fluoride (PVDF) membrane bag by the application of voltage of maximum 6 V across the supported liquid membrane (SLM), consisting of organic solvent and di-(2-ethylhexyl)phosphoric acid (D2EHPA). The parameters affecting the EME were optimized for Pb(II) ions. The optimum EME conditions were found to be 20% D2EHPA in 1-octanol impregnated in the wall of PVDF membrane (PVDF17) as the SLM, extraction time of 20 min, pH of sample solution of 8 and a voltage of 5 V. The PVDF-ErGO-GRC electrode system attained enrichment factors of 40 times and 80% of extraction with relative standard deviations (n=5) of 8.3%. Good linearity ranging from 0.25 to 2 nM with coefficients correlation of 0.999 was obtained. The Pb(II) ions detection limit of PVDF-ErGO-GRC electrode was found to be 0.09 nM. The newly developed single setup electrochemical system was applied to complex aqueous samples such as tap, river and sea water to evaluate the feasibility of the method for applications.


Subject(s)
Electrochemical Techniques/methods , Graphite/chemistry , Ion-Selective Electrodes , Lead/analysis , Polyvinyls/chemistry , Water/analysis , Electrochemical Techniques/standards , Ion-Selective Electrodes/standards , Limit of Detection
2.
Talanta ; 144: 969-76, 2015 Nov 01.
Article in English | MEDLINE | ID: mdl-26452915

ABSTRACT

In this study, a sensitive and cost-effective electrochemically reduced graphene oxide (ErGO) on graphite reinforced carbon (GRC) was developed for the detection of lead (Pb(II)) ions present in the real-life samples. A film of graphene oxide (GO) was drop-casted on GRC and their electrochemical properties were investigated using cyclic voltammetry (CV), amperometry and square wave voltammetry (SWV). Factors influencing the detection of Pb(II) ions, such as grades of GRC, constant applied cathodic potential (CACP), concentration of hydrochloric acid and drop-casting drying time were optimised. GO is irreversibly reduced in the range of -0.7 V to -1.6 V vs Ag/AgCl (3 M) in acidic condition. The results showed that the reduction behaviour of GO contributed to the high sensitivity of Pb(II) ions detection even at nanomolar level. The ErGO-GRC showed the detection limit of 0.5 nM and linear range of 3-15 nM in HCl (1 M). The developed electrode has potential to be a good candidate for the determination of Pb(II) ions in different aqueous system. The proposed method gives a good recovery rate of Pb(II) ions in real-life water samples such as tap water and river water.


Subject(s)
Lead/analysis , Water Pollutants, Chemical/analysis , Drinking Water/chemistry , Electrochemical Techniques , Electrodes , Graphite/chemistry , Lead/chemistry , Oxidation-Reduction , Oxides/chemistry , Rivers/chemistry , Seawater/chemistry , Water Pollutants, Chemical/chemistry
3.
Environ Technol ; 36(17): 2249-54, 2015.
Article in English | MEDLINE | ID: mdl-25749108

ABSTRACT

Para-arsanilic acid (p-ASA) has been widely used in the poultry industry to promote growth and prevent dysentery. It is excreted unchanged in the manure and released into non-target sites causing organoarsenic pollution risk to the environment and living system. Therefore, simple and effective analytical strategies are demanded for determining the samples that contain p-ASA. However, direct determination of both p-ASA and ortho-arsanilic acid (o-ASA) using differential pulse cathodic stripping voltammetry (DPCSV) gives the similar voltammograms that directly hamper the analysis used by the DPCSV technique. In this study, a method to determine and differentiate p-ASA from o-ASA via diazotization and coupling reaction of the amine groups followed by the direct DPCSV determination of diazo compounds is presented. The diazotization reaction carried out at pH 1.5 and 0 ± 1°C for 10 min showed two reduction peaks in DPCSV at-70 mV and -440 mV vs. Ag/AgCl (KCl 3 M). However, when the diazotization reaction was performed at pH 12.5 and 0 ± 1°C for 40 min, a coloured azo compound was produced and the DPCSV showed only one reduction peak that appeared at -600 mV vs. Ag/AgCl (3 M of KCl). The results of this study show that only p-ASA compound gave a reduction peak, whereas o-ASA compound did not give any peak. The detection limit of p-ASA was found to be 4 × 10(-8 )M. As a result, the proposed electro-analytical technique might be a good candidate to determine and differentiate the p-ASA present in the poultry and environmental samples.


Subject(s)
Arsanilic Acid/analysis , Electrochemical Techniques/methods , Water Pollutants, Chemical/analysis , Water/analysis , Animal Feed/analysis , Azo Compounds/analysis , Electrodes , Limit of Detection
4.
Mar Pollut Bull ; 83(1): 337-42, 2014 Jun 15.
Article in English | MEDLINE | ID: mdl-24775070

ABSTRACT

Recently in the Sultanate of Oman, there has been a rapid surge of coastal developments. These developments cause metal contamination, which may affect the habitats and communities at and near the coastal region. As a result, a study was conducted to assess the level of metal contamination and its impact on the marine sediments in the vicinity of the Single Buoy Moorings 3 (SBM3) at Mina Al Fahal in the Sultanate of Oman. Marine subtidal sediment samples were collected from six different stations of the SBM3 for the period ranging from June 2009 to April 2010. These samples were then analyzed for their level and distribution of the heavy metals of cadmium (Cd), copper (Cu), lead (Pb) and vanadium (V). Overall, low concentrations of all four heavy metals were measured from the marine sediments, indicating that the marine at SBM3 is of good quality.


Subject(s)
Geologic Sediments/analysis , Metals, Heavy/analysis , Water Pollutants, Chemical/analysis , Ecosystem , Environmental Monitoring , Oman
5.
Int J Occup Environ Health ; 19(3): 169-78, 2013.
Article in English | MEDLINE | ID: mdl-23885771

ABSTRACT

Malaysia has partially banned the use of asbestos. The prohibition of asbestos building materials in schools, clinics, and hospitals built by government started in 1999. Since 2005, prohibition has also been applied to all government buildings. However, asbestos construction materials such as roof and ceiling tiles are still sold in the market. There are no acts or regulations prohibiting the use of asbestos in private buildings in Malaysia. Asbestos was first used for industrial purposes in Malaysia in the 1960s and the first regulations related to asbestos have been around since the 1980s. Non-governmental organizations have been pushing the government to impose a total ban since the 1980s. Asbestos is still used in the manufacturing sector under the "control use" concept. The study found difficulties in established and validated medical record data on asbestos-related diseases. This paper reviews existing asbestos-related regulations and guidelines in Malaysia and discusses the urgency for a total ban in the use of asbestos in building materials in the country. In the meanwhile, stricter enforcement of occupational safety and health regulations related to the use and exposure of asbestos among workers in the manufacturing, construction, maintenance, and demolition sectors has been in place.


Subject(s)
Asbestos , Construction Materials/standards , Occupational Exposure/legislation & jurisprudence , Occupational Exposure/prevention & control , Occupational Health/legislation & jurisprudence , Humans , Malaysia , Occupational Diseases/prevention & control , Occupational Health/standards
6.
J Sep Sci ; 30(3): 391-8, 2007 Feb.
Article in English | MEDLINE | ID: mdl-17396598

ABSTRACT

An online preconcentration technique by dynamic pH junction was studied to improve the detection limit for anionic arsenic compounds by CE. The main target compound is roxarsone, or 3-nitro-4-hydroxyphenylarsonic acid, which is being used as an animal feed additive. The other inorganic and organoarsenic compounds studied are the possible biotransformation products of roxarsone. The arsenic species were separated by a dynamic pH junction in a fused-silica capillary using 15 mM phosphate buffer (pH 10.6) as the BGE and 15 mM acetic acid as the sample matrix. CE with UV detection was monitored at a wavelength of 192 nm. The influence of buffer pH and concentration on dynamic pH junction were investigated. The arsenic species focusing resulted in LOD improvement by a factor of 100-800. The combined use of C18 and anion exchange SPE and dynamic pH junction to CE analysis of chicken litter and soils helps to increase the detection sensitivity. Recoveries of spiked samples ranged between 70 and 72%.