Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Total Environ ; 427-428: 332-8, 2012 Jun 15.
Article in English | MEDLINE | ID: mdl-22578698

ABSTRACT

This study investigated the level of bisphenol A (BPA) in surface water used as potable water, drinking water (tap and bottled mineral water) and human plasma in the Langat River basin, Malaysia. BPA was present in 93% of the surface water samples at levels ranging from below limit of quantification (LOQ; 1.3 ng/L) to 215 ng/L while six fold higher levels were detected in samples collected near industrial and municipal sewage treatment plant outlets. Low levels of BPA were detected in most of the drinking water samples. BPA in tap water ranged from 3.5 to 59.8 ng/L with the highest levels detected in samples collected from taps connected to PVC pipes and water filter devices. Bottled mineral water had lower levels of BPA (3.3±2.6 ng/L) although samples stored in poor storage condition had significantly higher levels (11.3±5.3 ng/L). Meanwhile, only 17% of the plasma samples had detectable levels of BPA ranging from 0.81 to 3.65 ng/mL. The study shows that BPA is a ubiquitous contaminant in surface, tap and bottled mineral water. However, exposure to BPA from drinking water is very low and is less than 0.01% of the tolerable daily intake (TDI).


Subject(s)
Drinking Water/analysis , Environmental Exposure , Phenols/analysis , Water Pollutants, Chemical/analysis , Adult , Benzhydryl Compounds , Environmental Monitoring , Female , Humans , Malaysia , Male , Middle Aged , Mineral Waters/analysis , Phenols/blood , Rivers/chemistry , Water Pollutants, Chemical/blood
2.
Article in English | MEDLINE | ID: mdl-21607892

ABSTRACT

Migration of melamine has been determined for 41 types of retail melamine-ware products in Malaysia. This study was initiated by the Ministry of Health, Malaysia, in the midst of public anxiety on the possibility of melamine leaching into foods that come into contact with the melamine-ware. Thus, the objective of this study was to investigate the level of melamine migration in melamine utensils available on the market. Samples of melamine tableware, including cups and plates, forks and spoons, tumblers, bowls, etc., were collected from various retail outlets. Following the test guidelines for melamine migration set by the European Committee for Standardisation (CEN 2004) with some modifications, the samples were exposed to two types of food simulants (3% acetic acid and distilled water) at three test conditions (25°C (room temperature), 70 and 100°C) for 30 min. Melamine analysis was carried out using LC-MS/MS with a HILIC column and mobile phase consisting of ammonium acetate/formic acid (0.05%) in water and ammonium acetate/formic acid (0.05%) in acetonitrile (95 : 5, v/v). The limit of quantification (LOQ) was 5 ng/ml. Melamine migration was detected from all samples. For the articles tested with distilled water, melamine migration were [median (interquartile range)] 22.2 (32.6), 49.3 (50.9), 84.9 (89.9) ng/ml at room temperature (25°C), 70 and 100°C, respectively. In 3% acetic acid, melamine migration was 31.5 (35.7), 81.5 (76.2), 122.0 (126.7) ng/ml at room temperature (25°C), 70 and 100°C, respectively. This study suggests that excessive heat and acidity may directly affect melamine migration from melamine-ware products. However the results showed that melamine migration in the tested items were well below the specific migration limit (SML) of 30 mg/kg (30,000 ng/ml) set out in European Commission Directive 2002/72/EC.


Subject(s)
Cooking and Eating Utensils , Food Contamination/analysis , Triazines/analysis , Chromatography, Liquid , Food Safety , Humans , Malaysia , Spectrometry, Mass, Electrospray Ionization , Tandem Mass Spectrometry , Triazines/toxicity
SELECTION OF CITATIONS
SEARCH DETAIL
...