Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Language
Publication year range
1.
Clin Ophthalmol ; 8: 2533-9, 2014.
Article in English | MEDLINE | ID: mdl-25540578

ABSTRACT

BACKGROUND: There are limited data concerning the optic disc topography in normal-tension glaucoma (NTG) and primary open-angle glaucoma (POAG) patients living in Southeast Asian countries. This study aims to compare optic disc parameters in patients with NTG and POAG in Malaysia and to discuss the results in comparison with studies of NTG and POAG in other Asian countries. METHODS: This prospective cross-sectional study was performed in two hospitals with glaucoma service in Malaysia from 2010 to 2012. Seventy-seven patients of Malay ethnicity were enrolled in this study, including 32 NTG patients and 45 POAG patients. Using the Heidelberg Retinal Tomograph III, we measured optic disc area, cup area, rim area, cup volume, rim volume, cup-to-disc area ratio, mean cup depth, maximum cup depth, cup shape measure, height variation contour, mean retinal nerve fiber layer thickness, and retinal nerve fiber layer cross-sectional area. RESULTS: The eyes for NTG patients had significantly larger optic disc areas (2.65 [standard deviation, 0.41] vs 2.40 [standard deviation, 0.36] mm(2), respectively; P=0.006) and cup areas (1.54 [standard deviation, 0.43] vs 1.32 [standard deviation, 0.40] mm(2), respectively; P=0.027) compared with the eyes of POAG patients. Comparison of the other parameters between the two groups revealed no significant difference (P>0.050). The moderate and severe NTG patients showed significantly deeper cups and larger disc and cup areas when compared with the moderate and severe POAG patients (P<0.050). CONCLUSION: The NTG patients in this study have notably larger optic disc and cup areas than the POAG patients. Our observations are consistent with those reported in studies of NTG and POAG patients in Korea. The deeper cups and larger disc and cup areas may serve as indicators of severity when comparing NTG with POAG. However, these findings require verification with IOP and visual field results.

2.
Med J Malaysia ; 68(4): 338-42, 2013 Aug.
Article in English | MEDLINE | ID: mdl-24145263

ABSTRACT

There are limited data in the literature on the optic disc topography in normal tension glaucoma (NTG) patients in Asian countries, especially in Southeast Asia. This study is aimed at comparing optic disc topography in NTG patients and a control group in Malaysia, and we discuss the literature on NTG studies in other Asian populations. A comparative cross-sectional study was conducted in two hospitals with glaucoma services in Malaysia from November 2010 to February 2012. A total of 109 eyes of 109 Malay patients were included in this study: 32 NTG patients and 77 subjects in the control group. All participants underwent a thorough ocular examination, including visual acuity, subjective refraction, anterior segment and fundus examinations, Humphrey visual field 24-2, intraocular pressure measurement, gonioscopy examination and fundus photography. Optic disc topography was assessed using the Heidelberg Retinal Tomograph III by an identified masked investigator in each hospital. NTG patients had a notably larger disc area (2.65 (0.41) vs 2.19 (0.43) mm(2), respectively), larger cupping (1.54 (0.43) vs 0.63 (0.40) mm(2), respectively), smaller retinal rim areas (1.12 (0.41) vs 1.56 (0.33) mm(2), respectively), higher cup volume (0.47 (0.28) vs 0.11 (0.19) mm(3), respectively), reduced rim volume (0.23 (0.13) vs 0.41 (0.16) mm(3), respectively), higher cup to disc area ratio (0.58 (0.14) vs 0.27 (0.15), respectively), higher linear cup to disc ratio (0.76 (0.09) vs 0.49 (0.17) mm(2), respectively), higher mean cup depth (0.37 (0.09) vs 0.22 (0.09) mm, respectively), higher maximum cup depth (0.77 (0.16) vs 0.59 (0.20) mm, respectively), higher mean of cup shape measure (-0.04 (0.06) vs -0.16 (0.07), respectively), and thinner mean retinal nerve fibre layer thickness (0.15 (0.15) vs 0.24 (0.07) mm, respectively) compared to the control group (p<0.05). In conclusion, most of the optic disc parameters were significantly different in NTG patients compared to healthy individuals in Malaysia. Our findings are comparable to those reported in NTG studies in other Asian countries.


Subject(s)
Low Tension Glaucoma , Optic Disk , Cross-Sectional Studies , Humans , Intraocular Pressure , Malaysia
3.
Article in English | WPRIM (Western Pacific) | ID: wpr-630365

ABSTRACT

There are limited data in the literature on the optic disc topography in normal tension glaucoma (NTG) patients in Asian countries, especially in Southeast Asia. This study is aimed at comparing optic disc topography in NTG patients and a control group in Malaysia, and we discuss the literature on NTG studies in other Asian populations. A comparative cross-sectional study was conducted in two hospitals with glaucoma services in Malaysia from November 2010 to February 2012. A total of 109 eyes of 109 Malay patients were included in this study: 32 NTG patients and 77 subjects in the control group. All participants underwent a thorough ocular examination, including visual acuity, subjective refraction, anterior segment and fundus examinations, Humphrey visual field 24-2, intraocular pressure measurement, gonioscopy examination and fundus photography. Optic disc topography was assessed using the Heidelberg Retinal Tomograph III by an identified masked investigator in each hospital. NTG patients had a notably larger disc area (2.65 (0.41) vs 2.19 (0.43) mm(2), respectively), larger cupping (1.54 (0.43) vs 0.63 (0.40) mm(2), respectively), smaller retinal rim areas (1.12 (0.41) vs 1.56 (0.33) mm(2), respectively), higher cup volume (0.47 (0.28) vs 0.11 (0.19) mm(3), respectively), reduced rim volume (0.23 (0.13) vs 0.41 (0.16) mm(3), respectively), higher cup to disc area ratio (0.58 (0.14) vs 0.27 (0.15), respectively), higher linear cup to disc ratio (0.76 (0.09) vs 0.49 (0.17) mm(2), respectively), higher mean cup depth (0.37 (0.09) vs 0.22 (0.09) mm, respectively), higher maximum cup depth (0.77 (0.16) vs 0.59 (0.20) mm, respectively), higher mean of cup shape measure (-0.04 (0.06) vs -0.16 (0.07), respectively), and thinner mean retinal nerve fibre layer thickness (0.15 (0.15) vs 0.24 (0.07) mm, respectively) compared to the control group (p<0.05). In conclusion, most of the optic disc parameters were significantly different in NTG patients compared to healthy individuals in Malaysia. Our findings are comparable to those reported in NTG studies in other Asian countries.

SELECTION OF CITATIONS
SEARCH DETAIL
...