Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 31(13): 21407-21416, 2023 Jun 19.
Article in English | MEDLINE | ID: mdl-37381240

ABSTRACT

Tunable liquid crystal (LC) lenses have gained significant attention in recent decades due to their lightweight, low cost, and versatility in applications such as augmented reality, ophthalmic devices, and astronomy. Although various structures have been proposed to improve the performance of LC lenses, the thickness of the LC cell is a critical design parameter that is often reported without sufficient justification. While increasing the cell thickness can lead to a shorter focal length, it also results in higher material response times and light scattering. To address this issue, the Fresnel structure has been introduced as a solution to achieve a higher focal length dynamic range without increasing the cell thickness. In this study, we numerically investigate, for the first time (to our knowledge) the relationship between the number of phase resets and the minimum required cell thickness to achieve a Fresnel phase profile. Our findings reveal that the diffraction efficiency (DE) of a Fresnel lens also depends on the cell thickness. Specifically, to achieve a fast response Fresnel-structured-based LC lens with high optical transmission and over 90% DE using E7 as the LC material, the cell thickness should fall within the range of 13 to 23 µm.

2.
J Cancer Res Ther ; 13(3): 419-424, 2017.
Article in English | MEDLINE | ID: mdl-28862202

ABSTRACT

With the advent of new complex but precise radiotherapy techniques, the demands for an accurate, feasible three-dimensional (3D) dosimetry system have been increased. A 3D dosimeter system generally should not only have accurate and precise results but should also feasible, inexpensive, and time consuming. Recently, one of the new candidates for 3D dosimetry is optical computed tomography (CT) with a radiochromic dosimeter such as PRESAGE®. Several generations of optical CT have been developed since the 90s. At the same time, a large attempt has been also done to introduce the robust dosimeters that compatible with optical CT scanners. In 2004, PRESAGE® dosimeter as a new radiochromic solid plastic dosimeters was introduced. In this decade, a large number of efforts have been carried out to enhance optical scanning methods. This article attempts to review and reflect on the results of these investigations.


Subject(s)
Neoplasms/diagnostic imaging , Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Tomography, Optical , Humans , Neoplasms/pathology , Radiometry/methods , Radiotherapy Dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...