Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Biomed Eng Lett ; 13(4): 671-680, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37872996

ABSTRACT

Microfluidic systems with the ability to mimic the female reproductive tract (FRT) and sperm features have emerged as promising methods to separate sperm with higher quality for the assistant reproductive technology. Thereby, we designed and fabricated a microfluidic system based on FRT features with a focus on rheotaxis and thigmotaxis for passive sperm separation. In this regard, four various geometries (linear, square, zigzag, and sinusoidal) were designed, and the effect of rheotaxis and thigmotaxis were investigated. Although separated sperm in all microchannels were 100% motile, non-linear geometries were more effective than linear geometry in the term of separating the progressive sperm with high quality. In the presence of upstream flow, periodical changes in the slope of walls (in non-linear geometries) give rise to the periodical facing sperm with a high flow rate in the middle of microchannels, which was a reason for the high quality of separated sperm. However, because of sharp corners in the square and zigzag microchannels that create dead zones with a lack of upstream flow, which is noticeable via simulation results, these geometries have obstacles against sperm swimming toward the outlet, which was proved by image analysis. The sinusoidal geometry showed the highest enhancement level of the designed geometries compared to the linear geometry. Separated sperm exhibited 34.7% normal morphology, 100% motility, and 100% viability in the sinusoidal geometry. Therefore, the periodic change in the position of sperm from one wall to another wall can be a strategy for separating sperm with high quality. Graphical abstract: In the present study, we used a microfluidic system for studying the combined effects of thigmotaxis and rheotaxis for sperm separation process to achieve the successful Assisted reproductive technology (ART). The designed PDMS-based microfluidic system had four various geometries, including linear, square, zigzag, and sinusoidal. The functionality of separated sperm was evaluated by sperm tracking (ImageJ), motility assay (CASA software), and morphology assay (Papanicolaou ultrafast staining). Probing various geometries revealed 100% motility. In non-linear geometries, sperm's periodic detachment from the walls gave rise to the periodic interaction with the high flow velocity in the center of the channel, resulting in the separation of high-quality sperm with progressive motility. The collected data proved the influence of thigmotaxis on the quality of separated sperm. Morphologically improvement in separated sperm from the sinusoidal geometry was significant than others, which means the sinusoidal structure would be the best candidate for the sperm separation process. Supplementary Information: The online version contains supplementary material available at 10.1007/s13534-023-00294-8.

2.
Cryobiology ; 111: 26-29, 2023 06.
Article in English | MEDLINE | ID: mdl-36934956

ABSTRACT

Development of successful tissue cryopreservation methods requires specific knowledge regarding tissue permeation of individual cryoprotective agents (CPAs) and their combinations. The present study assessed the permeation of dimethyl sulfoxide, ethylene glycol, and propylene glycol into liver tissue, and addressed whether the diffusion coefficient of individual CPAs changes when combining CPAs. To do this, mouse liver slices were exposed at room temperature to 3.5 mol/L concentrations of CPAs individually or in combination for 15, 30, 45, and 60 min. Subsequently, tissue CPA concentrations were determined using a gas chromatography/mass spectrometry (GC/MS) method. Our results show that (1) the GC/MS method allows measurement of multiple CPA concentrations in a single small tissue sample, (2) dimethyl sulfoxide has a higher diffusion coefficient than ethylene glycol and propylene glycol, and (3) the CPA diffusivity appears to decrease in mixtures with multiple CPAs. These findings may help the development of effective tissue cryopreservation methods.


Subject(s)
Cryoprotective Agents , Dimethyl Sulfoxide , Animals , Mice , Cryoprotective Agents/pharmacology , Cryopreservation/methods , Propylene Glycol , Ethylene Glycol
3.
Mater Today Bio ; 16: 100349, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35875198

ABSTRACT

Targeted drug delivery systems using nanocarriers offer a versatile platform for breast cancer treatment; however, a robust, CD44-targeted niosomal formulation has not been developed and deeply studied (both in vitro and in vivo) yet. Here, an optimized system of epirubicin (Epi)-loaded niosomal nanoparticles (Nio) coated with hyaluronic acid (HA) has been engineered for targeting breast cancer cells. The nanoformulation was first optimized (based on size, polydispersity index, and entrapment efficiency); then, we characterized the morphology, stability, and release behavior of the nanoparticles. Epirubicin release from the HA-coated system (Epi-Nio-HA) showed a 21% (acidic buffer) and 20% (neutral buffer) reduction in comparison with the non-coated group (Epi-Nio). The cytotoxicity and apoptosis results of 4T1 and SkBr3 cells showed an approximately 2-fold increase in the Epi-Nio-HA system over Epi-Nio and free epirubicin, which confirms the superiority of the engineered nanocarriers. Moreover, real-time PCR data demonstrated the down-regulation of the MMP-2, MMP-9, cyclin D, and cyclin E genes expression while caspase-3 and caspase-9 gene expression were up-regulated. Confocal microscopy and flow cytometry studies uncovered the cellular uptake mechanism of the Epi-Nio-HA system, which was CD44-mediated. Furthermore, in vivo studies indicated Epi-Nio-HA decreased mice breast tumor volume by 28% (compared to epirubicin) without side effects on the liver and kidney. Conclusively, our results indicated that the HA-functionalized niosomes provide a promising nanoplatform for efficient and targeted delivery of epirubicin to potentially treat breast cancer.

4.
J Assist Reprod Genet ; 39(1): 19-36, 2022 Jan.
Article in English | MEDLINE | ID: mdl-35034216

ABSTRACT

Although medical advancements have successfully helped a lot of couples with their infertility by assisted reproductive technologies (ART), sperm selection, a crucial stage in ART, has remained challenging. Therefore, we aimed to investigate novel sperm separation methods, specifically microfluidic systems, as they do sperm selection based on sperm and/or the female reproductive tract (FRT) features without inflicting any damage to the selected sperm during the process. In this review, after an exhaustive studying of FRT features, which can implement by microfluidics devices, the focus was centered on sperm selection and investigation devices. During this study, we tried not to only point to the deficiencies of these systems, but to put forth suggestions for their improvement as well.


Subject(s)
Genitalia, Female/physiology , Sperm Count/instrumentation , Spermatozoa/cytology , Adult , Female , Genitalia, Female/microbiology , Humans , Male , Microfluidics/instrumentation , Microfluidics/methods , Microfluidics/statistics & numerical data , Reproductive Techniques, Assisted/standards , Reproductive Techniques, Assisted/trends , Sperm Count/methods , Sperm Count/trends , Spermatozoa/microbiology
SELECTION OF CITATIONS
SEARCH DETAIL
...