Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 12(9): e0184493, 2017.
Article in English | MEDLINE | ID: mdl-28910368

ABSTRACT

A substantive approach converting waste date pits to mercerized mesoporous date pit activated carbon (DPAC) and utilizing it in the removal of Cd(II), Cu(II), Pb(II), and Zn(II) was reported. In general, rapid heavy metals adsorption kinetics for Co range: 25-100 mg/L was observed, accomplishing 77-97% adsorption within 15 min, finally, attaining equilibrium in 360 min. Linear and non-linear isotherm studies revealed Langmuir model applicability for Cd(II) and Pb(II) adsorption, while Freundlich model was fitted to Zn(II) and Cu(II) adsorption. Maximum monolayer adsorption capacities (qm) for Cd(II), Pb(II), Cu(II), and Zn(II) obtained by non-linear isotherm model at 298 K were 212.1, 133.5, 194.4, and 111 mg/g, respectively. Kinetics modeling parameters showed the applicability of pseudo-second-order model. The activation energy (Ea) magnitude revealed physical nature of adsorption. Maximum elution of Cu(II) (81.6%), Zn(II) (70.1%), Pb(II) (96%), and Cd(II) (78.2%) were observed with 0.1 M HCl. Thermogravimetric analysis of DPAC showed a total weight loss (in two-stages) of 28.3%. Infra-red spectral analysis showed the presence of carboxyl and hydroxyl groups over DPAC surface. The peaks at 820, 825, 845 and 885 cm-1 attributed to Zn-O, Pb-O, Cd-O, and Cu-O appeared on heavy metals saturated DPAC, confirmed their binding on DPAC during the adsorption.


Subject(s)
Metals, Heavy/isolation & purification , Phoeniceae , Water Pollutants, Chemical/isolation & purification , Water Purification/instrumentation , Adsorption , Cadmium/isolation & purification , Carbon/chemistry , Copper/isolation & purification , Hydrogen-Ion Concentration , Kinetics , Lead/isolation & purification , Thermogravimetry , Zinc/isolation & purification
2.
Food Chem ; 176: 487-92, 2015 Jun 01.
Article in English | MEDLINE | ID: mdl-25624260

ABSTRACT

Ultra performance liquid chromatography coupled to mass spectrometry was used for the simultaneous separation and determination of reducing monosaccharides (fructose and glucose), a non-reducing disaccharide (sucrose) and oligosaccharides (kestose and nystose) in HILIC mode. The chromatographic separation of all saccharides was performed on a BEH amide column using an acetonitrile-water gradient elution. The detection was carried out using selected ion recording (SIR) acquisition mode. The validation of the proposed method showed that the limit of detection and limit of quantification values for the five analyzed compounds were in the range of 0.25-0.69µg/mL and 0.82-3.58µg/mL, respectively; while the response was linear in the range of 1-50µg/mL. The developed method showed potential usefulness for a rapid and sensitive analysis of underivatized saccharides and was used for determination of sugars in three date samples (Sefri, Mabroom, Ghassab) which were soxhlet extracted by ethanol.


Subject(s)
Chromatography, Liquid/methods , Monosaccharides/chemistry , Oligosaccharides/chemistry , Spectrometry, Mass, Electrospray Ionization/methods , Limit of Detection
SELECTION OF CITATIONS
SEARCH DETAIL
...