Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Europace ; 25(11)2023 11 02.
Article in English | MEDLINE | ID: mdl-37738643

ABSTRACT

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF). There are limited data on the PolarX Cryoballoon. The study aimed to establish the safety, efficacy, and feasibility of same day discharge for Cryoballoon PVI. METHODS AND RESULTS: Multi-centre study across 12 centres. Procedural metrics, safety profile, and procedural efficacy of the PolarX Cryoballoon with the Arctic Front Advance (AFA) Cryoballoon were compared in a cohort large enough to provide definitive comparative data. A total of 1688 patients underwent PVI with cryoablation (50% PolarX and 50% AFA). Successful PVI was achieved with 1677 (99.3%) patients with 97.2% (n = 1641) performed as day case procedures with a complication rate of <1%. Safety, procedural metrics, and efficacy of the PolarX Cryoballoon were comparable with the AFA cohort. The PolarX Cryoballoon demonstrated a nadir temperature of -54.6 ± 7.6°C, temperature at 30 s of -38.6 ± 7.2°C, time to -40°C of 34.1 ± 13.7 s, and time to isolation of 49.8 ± 33.2 s. Independent predictors for achieving PVI included time to reach -40°C [odds ratio (OR) 1.34; P < 0.001] and nadir temperature (OR 1.24; P < 0.001) with an optimal cut-off of ≤34 s [area under the curve (AUC) 0.73; P < 0.001] and nadir temperature of ≤-54.0°C (AUC 0.71; P < 0.001), respectively. CONCLUSIONS: This large-scale UK multi-centre study has shown that Cryoballoon PVI is a safe, effective day case procedure. PVI using the PolarX Cryoballoon was similarly safe and effective as the AFA Cryoballoon. The cryoablation metrics achieved with the PolarX Cryoballoon were different to that reported with the AFA Cryoballoon. Modified cryoablation targets are required when utilizing the PolarX Cryoballoon.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Cryosurgery/adverse effects , Cryosurgery/methods , Treatment Outcome , Time Factors , Pulmonary Veins/surgery , Catheter Ablation/methods , United Kingdom , Recurrence
2.
Access Microbiol ; 3(1): acmi000183, 2021.
Article in English | MEDLINE | ID: mdl-33997614

ABSTRACT

Lawsonella clevelandensis is an anaerobic, partially acid-fast, Gram-positive bacillus associated with abscess formation. We present the case of a 70-year-old male with chronic contained rupture of abdominal aortic aneurysm (CCR-AAA) complicated by intra-abdominal abscess formation. An abdominal computed tomography scan revealed a rim-enhancing retroperitoneal collection tracking into the subcutaneous layer of the left flank and buttock, suggestive of CCR-AAA with infected haematoma. He underwent ultrasound-guided needle aspiration of the intra-abdominal collection. Conventional culture techniques failed to isolate L. clevelandensis , and the diagnosis was only confirmed by means of 16S rRNA PCR. The patient underwent branched endovascular repair of his aneurysm, and was commenced on treatment with co-amoxiclav, resulting in significant reduction in the size of the infected collection. This is only the second reported case of infection with L. clevelandensis in the UK, and the first reported case of this organism causing infected CCR-AAA.

SELECTION OF CITATIONS
SEARCH DETAIL
...