Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Dent ; 2018: 2412084, 2018.
Article in English | MEDLINE | ID: mdl-29713345

ABSTRACT

OBJECTIVE: The objective of this study was to evaluate the level of adaptation of patients to newly fitted complete dentures in their dominant and nondominant sides, by means of ElectromyoFigureic signals. MATERIALS AND METHODS: Eighty-eight patients with complete dentures were evaluated in the study. Masticatory muscle (masseter and temporal) bioelectric activity of the patients with complete dentures was recorded at maximum intercuspal relation. Parametric statistical data were analyzed with one-way repeated measures ANOVA test. RESULTS: Measurement time was significantly different for both dominant (DS) and nondominant (NDS) sides: FΣs-DS = 21.51, p=0.0001; FΣs-NDS = 13.25, p=0.0001. Gender was also significantly different: FΣs-DS-gender = 41.53, p=0.001; FΣs-NDS-gender = 85.76, p=0.0001. The average surface area values showed significant difference in females. Prior experience with dentures showed no significant difference for both sides of mastication: FΣs-DS-experiences = 1.83, p=0.1772; F Σs-NDS-experiences = 3.30, p=0.0697. CONCLUSION: The planimetric indicators of bioelectric activity of masseter and temporalis muscles at maximum physiological loading conditions are significant discriminators of the level of functional adaptation of patients with new complete dentures.

2.
Int J Dent ; 2017: 5138950, 2017.
Article in English | MEDLINE | ID: mdl-28702055

ABSTRACT

OBJECTIVE: The aim of this study was to evaluate sensibility threshold for interocclusal thickness in experienced and nonexperienced denture wearers after the insertion of new complete dentures. MATERIALS AND METHODS: A total of 88 patients with complete dentures have participated in this study. The research was divided into two experimental groups, compared with the previous experience prosthetic dental treatment. The sensibility threshold for interocclusal thickness was measured with metal foil with 8 µm thickness and width of 8 mm, placed between the upper and lower incisor region. Statistical analysis was performed using standard software package BMDP (biomedical statistical package). RESULTS: Results suggest that time of measurement affects the average values of the sensibility threshold for interocclusal thickness (F = 242.68, p = 0.0000). Gender appeared to be a significant factor when it interacted with time measurement resulting in differences in sensibility threshold for interocclusal thickness (gender: F = 9.84, p = 0.018; F = 4.83, p = 0.0003). CONCLUSION: The sensibility threshold for interocclusal thickness was the most important functional adaptation in patient with complete dentures. A unique trait of this indicator is the progressive reduction of initial values and a tendency to reestablish the stationary state in the fifteenth week after dentures is taken off.

3.
Open Dent J ; 10: 656-663, 2016.
Article in English | MEDLINE | ID: mdl-28077970

ABSTRACT

This retrospective clinical study aimed to assess patient's satisfaction with removable partial dentures (RPDs), as retention, chewing ability, aesthetics during the observation period. MATERIAL AND METHODS: A total of 63 patients with RPDs, participated in this study. The following data was collected: Kennedy classification, denture design, denture support, satisfaction and success of RPD. RESULT: The results showed that 73.6% of patients were wearing RPD for the first time and were finally satisfied. According to the denture support of RPDs, clasp-retained quadrangular RPDs were 100% effective, followed by triangular dental support 81% and linear dental support 47.7%. Comparison of RPDs with attachment with RPDs with claps assessed through Fisher exact test, confirmed statistically significant difference (P=0.008), despite retention; however, chewing ability and aesthetics showed no statistically significant difference with X 2 test on patient's satisfaction with RPD with or without attachment. CONCLUSION: Patients often would prefer not showing the anterior buccal clasps of RPD, therefore are generally satisfied more with RPD with attachment based on level of retention, chewing ability and aesthetics.

4.
Eur J Dent ; 9(3): 382-386, 2015.
Article in English | MEDLINE | ID: mdl-26430367

ABSTRACT

OBJECTIVE: The aim of this study was to evaluate the influence of removable partial dentures (RPD) on the periodontal health of abutment and non-abutment teeth. MATERIALS AND METHODS: A total 107 patients with RPD participated in this study. It was examined 138 RPD, they were 87 with clasp-retained and 51 were RPD with attachments. The following periodontal parameters were evaluated for abutment and non-abutment teeth, plaque index (PLI), calculus index (CI), bleeding on probing (BOP), probing depth (PD) (mm) and tooth mobility (TM) index. These clinical measurements were taken immediately before insertion the RPD, then one and 3 months after insertion. The level of significance was set at (P < 0.05). RESULTS: The mean scores for PLI, CI, BOP, PD, and TM index, of the abutment teeth and non-abutment teeth were no statistically significant at the time of insertion of RPD. After 1-month, PLI was statistically significant (0.57 ± 0.55 for abutment and 0.30 ± 0.46 for non-abutment teeth). After 3 months, there were significant differences between abutment and non-abutment teeth with regard to the BOP (1.53 ± 0.50 and 1.76 ± 0.43 respectively), PD (0.28 ± 0.45 and 0.12 ± 0.33 respectively) and PLI (1.20 ± 0.46 and 0.75 ± 0.64 respectively). No significant mean difference in TM and CI was found between the abutment and non-abutment teeth (P > 0.05). CONCLUSIONS: With carefully planned prosthetic treatment and adequate maintenance of the oral and denture hygiene, we can prevent the periodontal diseases.

5.
Open Dent J ; 9: 132-9, 2015.
Article in English | MEDLINE | ID: mdl-25926896

ABSTRACT

The aim of this retrospective study was to evaluate the effect of removable partial dentures in periodontal abutment teeth in relation to the type of denture support and design of RPD in a five-year worn period. Methods : A total of 64 patients with removable partial dentures (RPDs), participated in this study. It were examined ninety-one RPDs. There were seventy-five RPDs with clasp-retained and sixteenth were RPDs with attachments. There were 28 females and 36 males, aged between 40-64 years, 41 maxillary and 50 mandible RPDs. For each subjects the following data were collected: denture design, denture support, and Kennedy classification. Abutment teeth were assessed for plaque index (PI), calculus index (CI), blending on probing (BOP), probing depth (PD), gingival recession (GR), tooth mobility (TM). Level of significance was set at p<0.05. Results : According to denture support of RPD, BOP, PD, PI, GR, CI and TM-index showed no statistically significant difference. Based on the denture design of RPD's, BOP, PD, PI, CI, and TM-index proved no statistically significant difference. Except GR-index according to denture design confirmed statistically significant difference in RPD with clasp p<0.01. The higher values of all periodontal parameter as BOP, PD, PI, CI and TM were in patients with RPD's with claps comparing with RPD's with attachment. Conclusion : RPD's with clasp increased level of gingival inflammation in regions covered by the dentures and below the clasp arms in abutment teeth.

SELECTION OF CITATIONS
SEARCH DETAIL
...