Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Br J Ophthalmol ; 103(6): 802-804, 2019 06.
Article in English | MEDLINE | ID: mdl-30049800

ABSTRACT

AIM: To calculate a regression formula for intraoperative lagophthalmos to determine the amount of correction in levator resection for mild to moderate congenital ptosis. METHODS: This retrospective study included 38 eyelids from 28 consecutive children with congenital ptosis with levator function of 4 mm or better who showed satisfactory surgical outcomes defined as postoperative margin reflex distance-1 (MRD1) ≥3 mm in each eye and difference in MRD1 ≤1 mm between eyes at 6 months after levator resection. We investigated whether the degree of intraoperative lagophthalmos measured by calliper correlated with the preoperative values of MRD1, levator function and age. A stepwise multiple regression analysis was performed with intraoperative lagophthalmos as the dependent variable. RESULTS: The mean intraoperative lagophthalmos was 7.4±0.9 mm (range, 6-10 mm). The intraoperative lagophthalmos was found to have a statistically significant negative correlation with preoperative MRD1 (r2 =0.55, p<0.0001) and levator function (r2 =0.53, p<0.0001), respectively. A stepwise multiple regression analysis resulted in the following regression formula: Intraoperative lagophthalmos=9.08 - 0.48×Preoperative MRD1 - 0.26×Levator function (r2 =0.60, p<0.0001). CONCLUSION: Intraoperative lagophthalmos in patients with satisfactory surgical outcome correlated negatively with both preoperative MRD1 and levator function and accounting for both variables resulted in a stronger correlation than either variable alone. Surgeons would be able to calculate the amount of surgical correction using this formula of intraoperative lagophthalmos, which could lead to a satisfactory surgical outcome in levator resection for congenital ptosis.


Subject(s)
Blepharoplasty/methods , Blepharoptosis/surgery , Eye Movements/physiology , Eyelids/diagnostic imaging , Oculomotor Muscles/surgery , Suture Techniques , Blepharoptosis/congenital , Child , Child, Preschool , Eyelids/surgery , Female , Follow-Up Studies , Humans , Intraoperative Period , Male , Oculomotor Muscles/physiopathology , Retrospective Studies , Treatment Outcome
2.
Eye (Lond) ; 32(12): 1864-1870, 2018 12.
Article in English | MEDLINE | ID: mdl-30154573

ABSTRACT

OBJECTIVES: To describe and evaluate a novel surgical approach to orbital wall reconstruction that uses three-dimensionally (3D) printed templates to mold a customized orbital implant. METHODS: A review was conducted of 11 consecutive patients who underwent orbital wall reconstruction using 3D-printed customized orbital implant templates. In these procedures, the orbital implant was 3D pressed during surgery and inserted into the fracture site. The outcomes of this approach were analyzed quantitatively by measuring the orbital tissue volumes within the bony orbit using computed tomography. RESULTS: All 11 orbital wall reconstructions (6 orbital floor and 5 medial wall fractures) were successful with no post operative ophthalmic complications. Statistically significant differences were found between the preoperative and post operative orbital tissue volumes for the affected orbit (24.00 ± 1.74 vs 22.31 ± 1.90 cm3; P = 0.003). There was no statistically significant difference found between the tissue volume of the contralateral unaffected orbit and the affected orbit after reconstruction (22.01 ± 1.60 cm3 vs 22.31 ± 1.90 cm3; P = 0.182). CONCLUSION: 3D-printed customized orbital implant templates can be used to press and trim conventional implantable materials with patient-specific contours and sizes for optimal orbital wall reconstruction. It is difficult to design an orbital implant that exactly matches the shape and surface of a blowout fracture site due to the unique 3D structure of the orbit. The traditional surgical method is to visually inspect the fracture site and use eye measurements to cut a two-dimensional orbital implant that corresponds to the anatomical structure of the fracture site. However, implants that do not fit the anatomical structure of a fracture site well can cause complications such as enophthalmos, diplopia and displacement of the implant.


Subject(s)
Enophthalmos/surgery , Orbit/surgery , Orbital Fractures/surgery , Orbital Implants , Plastic Surgery Procedures/methods , Printing, Three-Dimensional , Prosthesis Design/methods , Adult , Aged , Female , Humans , Male , Middle Aged , Tomography, X-Ray Computed , Young Adult
3.
Br J Ophthalmol ; 102(11): 1591-1595, 2018 11.
Article in English | MEDLINE | ID: mdl-29420193

ABSTRACT

PURPOSE: To investigate the factors associated with response to steroid treatment and recurrence in patients with IgG4-related ophthalmic disease (ROD). METHODS: Twenty-eight patients with biopsy-proven IgG4-ROD treated between March 2010 and January 2017 were included in this retrospective study. Clinical features, serum IgG4 levels, systemic involvement, treatments and treatment outcome, factors associated with response to treatment and recurrence were assessed. RESULT: Thirteen men and 15 women (mean age 50.8 years) were evaluated over mean follow-up period of 27.3 months. Elevated serum IgG4 levels (>1.35 g/L) and systemic disease were noted in 9 (32%) and 18 patients (64%), respectively. The lacrimal gland was involved in all patients, and 22 patients (78.6%) had bilateral involvement. Most patients (82%) responded well to systemic steroids, but 12 (43%) relapsed after the initial steroid treatment, requiring additional therapies to achieve remission. Complete response to initial steroid treatment was associated with elevated serum IgG4 levels before treatment (P=0.001) and bilateral orbital involvement (P=0.050). Recurrence was associated with elevated serum IgG4 levels before treatment (P=0.007), lower dose (P=0.057) and shorter duration of initial steroids (P=0.042). Patients with recurrence eventually required significantly more steroids than those without recurrence (P=0.011). CONCLUSIONS: Patients with IgG4-ROD responded well to systemic steroid treatment, but recurrence was common, particularly among those with elevated serum IgG4 levels and shorter duration of initial steroid treatment. Low-dose maintenance treatment with systemic steroids should be considered to avoid recurrence in patients with elevated serum IgG4 levels.


Subject(s)
Autoimmune Diseases/drug therapy , Glucocorticoids/therapeutic use , Immunoglobulin G/blood , Lacrimal Apparatus Diseases/drug therapy , Orbital Diseases/drug therapy , Administration, Oral , Adult , Autoimmune Diseases/blood , Female , Humans , Infusions, Intravenous , Lacrimal Apparatus Diseases/blood , Male , Methylprednisolone/therapeutic use , Middle Aged , Orbital Diseases/blood , Plasma Cells/immunology , Recurrence , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...