Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 370
Filter
1.
Perioper Med (Lond) ; 13(1): 56, 2024 Jun 14.
Article in English | MEDLINE | ID: mdl-38877533

ABSTRACT

BACKGROUND: Remimazolam is a short-acting benzodiazepine newly approved for the induction and maintenance of general anesthesia. Remimazolam emerges as an ideal drug for the neurosurgical population due to its rapid emergence, enabling early neurological assessment, and its ability to maintain perfusion pressure, which is crucial for preventing cerebral ischemia. However, the use of benzodiazepine has been associated with an increased risk of postoperative delirium (POD). There is currently limited evidence about the relationship between remimazolam-based total intravenous anesthesia (TIVA) and POD. METHODS: In this double-blind, randomized, non-inferiority trial, we plan to include 696 adult patients with American Society of Anesthesiologists physical status class I to III, undergoing elective neurovascular surgery under general anesthesia. After informed consent, the patients will be randomized to receive either remimazolam or propofol-based TIVA with a 1:1 ratio. The primary outcome is the incidence of POD within 5 days after surgery. Secondary outcomes include subtypes, number of positive assessments and severity of POD, emergence agitation, intraoperative awareness and undesirable patient movement, intraoperative hypotension, and postoperative cognitive function. The data will be analyzed in modified intention to treat. DISCUSSION: This trial will evaluate the effect of remimazolam on the development of POD compared to propofol anesthesia. The results of this trial will provide evidence regarding the choice of optimal anesthetics to minimize the risk of POD in neurosurgical patients. TRIAL REGISTRATION: The study protocol was prospectively registered at the Clinical trials ( https://clinicaltrials.gov , NCT06115031, principal investigator: Jiseon Jeong; date of first registration: November 2, 2023, before the recruitment of the first participant.

2.
ACS Appl Mater Interfaces ; 16(24): 31384-31391, 2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38855921

ABSTRACT

Soft electronic materials hold great promise for advancing flexible functional devices. Among the various soft materials available, hydrogels are particularly attractive for soft electronic device development due to their inherent properties, including transparency, shape adaptability through swelling/deswelling, and self-healing capabilities. Transparent hydrogels contribute to the creation of advanced smart devices such as sensors, smart windows, and anticounterfeiting technologies. Poly(vinyl alcohol) hydrogels are used as a platform for creating electrofluorochromic (EFC) devices in combination with oligothiophene-conjugated benzothiazole derivatives (OCBs) as fluorescent emitters. OCBs demonstrated excited-state intramolecular proton transfer (ESIPT) behavior with a large Stokes shift and emission changes responsive to solvent polarity and pH stimuli. Even in the solid state, OCBs exhibited strong fluorescence emission across a wide range of colors from blue to red, making them exceptionally well-suited for EFC device development. Their quantum yields in the powder state were obtained between 2.3% and 19.9%. Through the incorporation of OCBs into a PVA hydrogel (OCB@PVA), we achieved the successful fabrication of flexible EFC devices, including electronic paper and smart panels. When electric potentials (-2.4 and +2.4 V) were applied in OCB@PVA, fluorescence color changes were observed by an electrochemically induced pH change owing to electrohydrolysis of water. These devices demonstrated the potential of OCB@PVA hydrogels in the realm of flexible electronics. They could be used to create innovative and versatile devices with stimuli-responsive fluorescence properties.

3.
J Anesth ; 2024 Jun 02.
Article in English | MEDLINE | ID: mdl-38824469

ABSTRACT

PURPOSE: Adequate oxygenation and airway management during deep sedation can be challenging. We investigated the effect of high-flow nasal cannula (group HF) and conventional nasal cannula (group CO) during sedation for endoscopic submucosal dissection (ESD). METHODS: Patients undergoing ESD with deep sedation were enrolled. The primary outcome was difference in lowest oxygen saturation (SpO2) between the groups. Incidence of hypoxia (SpO2 < 90%), patients with SpO2 < 95%, hypercapnia, and airway interventions; operator satisfaction; and adverse events were recorded. RESULTS: Thirty-two patients in each group completed the study. The mean of minimum SpO2 values was significantly higher in group HF than in group CO (96.8% ± 4.2% vs. 93.3% ± 5.3%, p = 0.005). The incidence of hypoxia was comparable between the groups (4 [12.5%] vs. 6 [18.8%], p = 0.491); however, patients with SpO2 < 95% were significantly less in group HF (5 [15.6%] vs. 18 [56.3%], p = 0.003). Incidence of hypercapnia was higher in group HF than in group CO (14 [46.7%] vs. 5 [16.7%], p = 0.013). Airway rescue interventions were significantly less common in group HF. Satisfaction of operators and post-procedural complications were comparable between the two groups. In multivariable analysis, group CO and higher body mass index were risk factors for airway managements (odds ratio [95% confidence interval]: 6.204 [1.784-21.575], p = 0.004; 1.337 [1.043-1.715], p = 0.022, respectively). CONCLUSIONS: Compared to conventional nasal cannula, high-flow nasal cannula maintained higher minimum SpO2 value during deep sedation with propofol-remifentanil for ESD. TRIAL REGISTRATION: Clinical Trial Registry of the Republic of Korea (KCT0006618, https://cris.nih.go.kr ; registered September 29, 2021; principal investigator: Ji Won Choi).

4.
Anesth Pain Med (Seoul) ; 19(2): 94-108, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38725164

ABSTRACT

Cancer is a leading cause of death worldwide. With the increasingly aging population, the number of emerging cancer cases is expected to increase markedly in the foreseeable future. Surgical resection with adjuvant therapy is the best available option for the potential cure of many solid tumors; thus, approximately 80% of patients with cancer undergo at least one surgical procedure during their disease. Agents used in general anesthesia can modulate cytokine release, transcription factors, and/or oncogenes. This can affect host immunity and the capability of cancer cells to survive and migrate, not only during surgery but for up to several weeks after surgery. However, it remains unknown whether exposure to anesthetic agents affects cancer recurrence or metastasis. This review explores the current literature to explain whether and how the choice of anesthetic and perioperative medication affect cancer surgery outcomes.

5.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38624037

ABSTRACT

AIMS: Pulmonary vein isolation using cryoablation is effective and safe in patients with atrial fibrillation (AF). Although both obesity and underweight are associated with a higher risk for incident AF, there is limited data on the efficacy and safety following cryoablation according to body mass index (BMI) especially in Asians. METHODS AND RESULTS: Using the Korean Heart Rhythm Society Cryoablation registry, a multicentre registry of 12 tertiary hospitals, we analysed AF recurrence and procedure-related complications after cryoablation by BMI (kg/m2) groups (BMI < 18.5, underweight, UW; 18.5-23, normal, NW; 23-25, overweight, OW; 25-30, obese Ⅰ, OⅠ; ≥30, obese Ⅱ, OⅡ). A total of 2648 patients were included (median age 62.0 years; 76.7% men; 55.6% non-paroxysmal AF). Patients were categorized by BMI groups: 0.9% UW, 18.7% NW, 24.8% OW, 46.1% OI, and 9.4% OII. Underweight patients were the oldest and had least percentage of non-paroxysmal AF (33.3%). During a median follow-up of 1.7 years, atrial arrhythmia recurred in 874 (33.0%) patients (incidence rate, 18.9 per 100 person-years). After multivariable adjustment, the risk of AF recurrence was higher in UW group compared with NW group (adjusted hazard ratio, 95% confidence interval; 2.55, 1.18-5.50, P = 0.02). Procedure-related complications occurred in 123 (4.7%) patients, and the risk was higher for UW patients (odds ratio, 95% confidence interval; 2.90, 0.94-8.99, P = 0.07), mainly due to transient phrenic nerve palsy. CONCLUSION: Underweight patients showed a higher risk of AF recurrence after cryoablation compared with NW patients. Also, careful attention is needed on the occurrence of phrenic nerve palsy in UW patients.


Subject(s)
Atrial Fibrillation , Body Mass Index , Cryosurgery , Obesity , Pulmonary Veins , Recurrence , Registries , Humans , Atrial Fibrillation/surgery , Cryosurgery/adverse effects , Male , Female , Middle Aged , Republic of Korea/epidemiology , Aged , Treatment Outcome , Risk Factors , Pulmonary Veins/surgery , Obesity/complications , Thinness/complications , Time Factors , Postoperative Complications/epidemiology , Postoperative Complications/etiology
6.
ChemSusChem ; : e202400593, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38676292

ABSTRACT

Recent advances in electrosynthesis of nanomaterials expanded structural and compositional variations accessible by the electrochemical method; however, reliably synthesizable morphological variety fall shy of that available by conventional solvothermal synthesis. In this communication, electrochemical preparation of surfactant-free hollow nanoparticles is demonstrated. By anodic conversion of core-shell precursors with metastable cores, hollowed nickel nanoparticles with uniform dimensions were synthesized and characterized. Implementation of TEM grids as the working electrodes, identical location tracking of the morphological evolution of single particles to anodic stimulus has been demonstrated. The synthesized nanoparticles were employed as catalysts for the alkaline hydrogen evolution reaction and exhibited catalytic rates that compare favorably to the Pt/C benchmark. This marks the first pure electrochemical synthesis of hollow nanoparticles and shall contribute to the structural diversification of electrosynthesized nanomaterials.

7.
Can J Anaesth ; 71(5): 619-628, 2024 May.
Article in English | MEDLINE | ID: mdl-38468077

ABSTRACT

PURPOSE: Recently, endotracheal tubes with an embedded temperature sensor in the inner surface of the tube cuff (temperature tracheal tubes) have been developed. We sought to assess whether temperature tracheal tubes show a good agreement with esophageal temperature probes during surgery. METHODS: We enrolled 40 patients who underwent laparoscopic surgery in an observational study. The tracheas of all patients were intubated with a temperature tracheal tube, and an esophageal temperature probe was inserted into the esophagus. Tracheal and esophageal temperatures were recorded at 15-min intervals until the end of surgery. Temperatures from both devices were analyzed using Bland-Altman analysis, four-quadrant plots, and polar plots. RESULTS: We analyzed 261 data points from 36 patients. Temperatures ranges were 34.2 °C to 36.6 °C for the tracheal temperature tube and 34.7 °C to 37.2 °C for the esophageal temperature probe. Bland-Altman analysis showed an acceptable agreement between the two devices, with an overall mean bias (95% limit of agreement) of -0.3 °C (-0.8 °C to 0.1 °C) and a percentage error of 3%; the trending ability (temperature changes over time) between the two devices showed a concordance rate of 94% in four-quadrant plot (cut-off ≥ 92%), but this was higher than the acceptable mean angular bias of 177° (cut-off < ± 5°) and radial limits of agreement of 52° (cut-off < ± 30°) in the polar plot. Bronchoscopy during extubation and patient interviews at six hours postoperatively revealed no serious injuries related to the use of the temperature tracheal tube. CONCLUSION: The temperature tracheal tube showed an acceptable overall mean bias of -0.3 °C and a percentage error of 3%, but incompatible trending ability with the esophageal temperature probe. STUDY REGISTRATION: cris.nih.go.kr (KCT0007265); 22 April 2022.


RéSUMé: OBJECTIF: Récemment, des sondes endotrachéales munies d'un capteur de température intégré dans la surface interne du ballonnet de la sonde (sondes thermiques trachéales) ont été mises au point. Nous avons cherché à évaluer si les sondes trachéales de température montraient une bonne concordance avec les sondes thermiques œsophagiennes pendant la chirurgie. MéTHODE: Nous avons recruté 40 patient·es ayant bénéficié d'une chirurgie par laparoscopie dans le cadre d'une étude observationnelle. Les trachées de tou·tes les patient·es ont été intubées à l'aide d'une sonde trachéale de température et une sonde thermique œsophagienne a été insérée dans l'œsophage. Les températures trachéale et œsophagienne ont été enregistrées à des intervalles de 15 minutes jusqu'à la fin de la chirurgie. Les températures des deux appareils ont été analysées à l'aide d'une analyse de Bland-Altman, de diagrammes à quatre quadrants et de diagrammes polaires. RéSULTATS: Nous avons analysé 261 points de données provenant de 36 patient·es. Les plages de température allaient de 34,2 °C à 36,6 °C pour la sonde trachéale de température et de 34,7 °C à 37,2 °C pour la sonde thermique œsophagienne. L'analyse de Bland-Altman a montré une concordance acceptable entre les deux dispositifs, avec un biais moyen global (limite de 95 % de la concordance) de −0,3 °C (−0,8 °C à 0,1 °C) et un pourcentage d'erreur de 3 %; la capacité de tendance (changements de température au fil du temps) entre les deux dispositifs a montré un taux de concordance de 94 % dans un diagramme à quatre quadrants (limite ≥ 92 %), mais cette capacité était plus élevée que le biais angulaire moyen acceptable de 177° (limite < ± 5°) et que les limites radiales de l'accord de 52° (limite < ± 30°) dans le diagramme polaire. La bronchoscopie réalisée lors de l'extubation et les entretiens avec les patient·es six heures après l'opération n'ont révélé aucune blessure grave liée à l'utilisation de la sonde trachéale de température. CONCLUSION: La sonde trachéale de température a montré un biais moyen global acceptable de −0,3 °C et un pourcentage d'erreur de 3 %, mais une capacité de tendance incompatible avec la sonde thermique œsophagienne. ENREGISTREMENT DE L'éTUDE: cris.nih.go.kr (KCT0007265); 22 avril 2022.


Subject(s)
Laparoscopy , Trachea , Humans , Temperature , Body Temperature , Intubation, Intratracheal
8.
Chemistry ; 30(27): e202400191, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38498874

ABSTRACT

Controlling the formation of photoexcited triplet states is critical for many (photo)chemical and physical applications. Here, we demonstrate that a permanent out-of-plane distortion of the benzothioxanthene imide (BTI) dye promotes intersystem crossing by increasing spin-orbit coupling. This manipulation was achieved through a subtle chemical modification, specifically the bay-area methylation. Consequently, this simple yet efficient approach expands the catalog of known molecular engineering strategies for synthesizing heavy atom-free, dual redox-active, yet still emissive and synthetically accessible photosensitizers.

9.
Anesth Analg ; 2024 Feb 27.
Article in English | MEDLINE | ID: mdl-38412113

ABSTRACT

BACKGROUND: The effect of sevoflurane on left ventricular diastolic function is not well understood. We hypothesized that parameters of diastolic function may improve under sevoflurane anesthesia in patients with preexisting diastolic dysfunction compared to patients with normal diastolic function. METHODS: This observational study included 60 patients undergoing breast surgery or laparoscopic cholecystectomy. Patients were assigned to diastolic dysfunction (n = 34) or normal (n = 26) groups of septal e' < 8 or ≥ 8.0 cm/s on the first thoracic echocardiography (TTE) performed before anesthesia. During anesthesia, sevoflurane was maintained at 1 to 2 minimum alveolar concentration (MAC) to maintain the bispectral index at 40 to 50. At the end of surgery, the second TTE was performed under 0.8 to 1 MAC of sevoflurane with the patient breathing spontaneously without ventilator support. Primary end point was the percentage change (Δ) of e' on 2 TTEs (Δe'). Secondary end points were ΔE/e', Δleft atrial volume index (ΔLAVI), and Δtricuspid regurgitation maximum velocity (ΔTR Vmax). These percentage changes (Δ) were compared between diastolic dysfunction and normal groups. RESULTS: e' (Δe': 30 [6, 64] vs 0 [-18, 11]%; P < .001), mitral inflow E wave velocity (E), mitral inflow E/A ratio (E/A), and mitral E velocity deceleration time (DT) improved significantly in diastolic dysfunction group compared to normal group. LAVI decreased in diastolic dysfunction group but did not reach statistical significance between the 2 groups (ΔLAVI:-15 [-31, -3] vs -4 [-20, 10]%, P = .091). ΔE/e' was not different between the 2 groups (11 [-16, 26] vs 12 [-9, 22]%, P = .853) (all: median [interquartile range, IQR]). TR was minimal in both groups. CONCLUSIONS: In this study, echocardiographic parameters of diastolic function, including septal e', E, E/A, and DT, improved with sevoflurane anesthesia in patients with preexisting diastolic dysfunction, but remained unchanged in patients with normal diastolic function.

10.
Small ; : e2400038, 2024 Feb 25.
Article in English | MEDLINE | ID: mdl-38402430

ABSTRACT

Development of synthetic strategies selectively yielding single crystals is desired owing to the facet-dependent chemical reactivities. Recent advances in electrochemical materials synthesis yielded nanomaterials that are surfactant-free, however, typically in polycrystalline forms. In this work, an electrochemical synthetic strategy selectively yielding single-crystalline nanoparticles by implementation of surface-selective heating of the working electrode is developed. Single crystals of copper, silver, gold, and platinum are afforded, and the crystallinity verified by electron diffraction and chemical reactivity studies. Notably, Cu (100) surface prepared by electrochemical synthesis yielded high single product selectivity when applied to electrochemical CO2 reduction catalysis.

11.
Sci Rep ; 14(1): 3864, 2024 02 16.
Article in English | MEDLINE | ID: mdl-38366042

ABSTRACT

We aimed to evaluate the feasibility of MR elastography (MRE) using a transpelvic approach. Thirty-one patients who underwent prostate MRE and had a pathological diagnosis were included in this study. MRE was obtained using a passive driver placed at the umbilicus and iliac crests. The shear stiffness, clinical data, and conventional imaging findings of prostate cancer and benign prostatic hyperplasia (BPH) were compared. Inter-reader agreements were evaluated using the intraclass coefficient class (ICC). Prostate MRE was successfully performed for all patients (100% technical success rate). Nineteen cancer and 10 BPH lesions were visualized on MRE. The mean shear stiffness of cancer was significantly higher than that of BPH (5.99 ± 1.46 kPa vs. 4.67 ± 1.54 kPa, p = 0.045). One cancer was detected on MRE but not on conventional sequences. Six tiny cancer lesions were not visualized on MRE. The mean size of cancers that were not detected on MRE was smaller than that of cancers that were visible on MRE (0.8 ± 0.3 cm vs. 2.3 ± 1.8 cm, p = 0.001). The inter-reader agreement for interpreting MRE was excellent (ICC = 0.95). Prostate MRE with transpelvic vibration is feasible without intracavitary actuators. Transpelvic prostate MRE is reliable for detecting focal lesions, including clinically significant prostate cancer and BPH.


Subject(s)
Elasticity Imaging Techniques , Prostatic Hyperplasia , Prostatic Neoplasms , Male , Humans , Prostate/diagnostic imaging , Vibration , Elasticity Imaging Techniques/methods , Feasibility Studies , Prostatic Hyperplasia/diagnostic imaging , Prostatic Neoplasms/diagnostic imaging , Reproducibility of Results , Magnetic Resonance Imaging/methods
12.
Ann Pharmacother ; 58(4): 383-390, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37401103

ABSTRACT

BACKGROUND: Only some studies have directly compared and analyzed the roles of activated partial thromboplastin time (aPTT) and activated clotting time (ACT) in coagulation monitoring during argatroban administration. OBJECTIVES: This study aims to assess the correlation of argatroban dose with ACT and aPTT values and to identify the optimal coagulation test for argatroban dose adjustment. METHODS: We evaluated 55 patients on extracorporeal membrane oxygenation (ECMO) who received argatroban for more than 72 hours. The correlation between argatroban dose and aPTT and ACT values was evaluated. To compare argatroban dose and bleeding events according to liver dysfunction, the patients were divided into 2 groups based on alanine aminotransferase and total bilirubin. RESULTS: Among the 55 patients, a total of 459 doses and coagulation tests were evaluated. The aPTT and ACT values showed a weak correlation with argatroban dose, with the Pearson correlation coefficients of 0.261 (P < 0.001) and 0.194 (P = 0.001), respectively. The agreement between the target 150 to 180 seconds for ACT and 55 to 75 seconds for aPTT was observed in 140 patients (46.1%). Twenty-four patients (43.6%) had liver dysfunction when they started argatroban. The median argatroban dose was lower in the liver dysfunction group than in the control group (0.094 mcg/kg/min vs 0.169 mcg/kg/min, P = 0.020). Difference was not observed between the 2 groups in the amount of red blood cell (0.47 vs 0.43 pack, P = 0.909) and platelet (0.60 vs 0.08 pack, P = 0.079) transfusion per day. CONCLUSION AND RELEVANCE: A weak correlation was observed between argatroban dose and the aPTT and ACT values. However, the agreement between aPTT and ACT was only 46.1% regarding the scope of target range. Further research is necessary to determine how to assess the optimal argatroban dose for patients administered argatroban while undergoing ECMO at the intensive care unit.


Subject(s)
Arginine/analogs & derivatives , Extracorporeal Membrane Oxygenation , Liver Diseases , Sulfonamides , Humans , Partial Thromboplastin Time , Heparin/adverse effects , Anticoagulants/adverse effects , Extracorporeal Membrane Oxygenation/adverse effects , Pipecolic Acids
13.
Anesthesiology ; 140(5): 920-934, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38109657

ABSTRACT

BACKGROUND: Mechanical power (MP), the rate of mechanical energy (ME) delivery, is a recently introduced unifying ventilator parameter consisting of tidal volume, airway pressures, and respiratory rates, which predicts pulmonary complications in several clinical contexts. However, ME has not been previously studied in the perioperative context, and neither parameter has been studied in the context of thoracic surgery utilizing one-lung ventilation. METHODS: The relationships between ME variables and postoperative pulmonary complications were evaluated in this post hoc analysis of data from a multicenter randomized clinical trial of lung resection surgery conducted between 2020 and 2021 (n = 1,170). Time-weighted average MP and ME (the area under the MP time curve) were obtained for individual patients. The primary analysis was the association of time-weighted average MP and ME with pulmonary complications within 7 postoperative days. Multivariable logistic regression was performed to examine the relationships between energy variables and the primary outcome. RESULTS: In 1,055 patients analyzed, pulmonary complications occurred in 41% (431 of 1,055). The median (interquartile ranges) ME and time-weighted average MP in patients who developed postoperative pulmonary complications versus those who did not were 1,146 (811 to 1,530) J versus 924 (730 to 1,240) J (P < 0.001), and 6.9 (5.5 to 8.7) J/min versus 6.7 (5.2 to 8.5) J/min (P = 0.091), respectively. ME was independently associated with postoperative pulmonary complications (ORadjusted, 1.44 [95% CI, 1.16 to 1.80]; P = 0.001). However, the association between time-weighted average MP and postoperative pulmonary complications was time-dependent, and time-weighted average MP was significantly associated with postoperative pulmonary complications in cases utilizing longer periods of mechanical ventilation (210 min or greater; ORadjusted, 1.46 [95% CI, 1.11 to 1.93]; P = 0.007). Normalization of ME and time-weighted average MP either to predicted body weight or to respiratory system compliance did not alter these associations. CONCLUSIONS: ME and, in cases requiring longer periods of mechanical ventilation, MP were independently associated with postoperative pulmonary complications in thoracic surgery.


Subject(s)
One-Lung Ventilation , Positive-Pressure Respiration , Humans , Positive-Pressure Respiration/adverse effects , Lung , Respiration, Artificial/adverse effects , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Tidal Volume , One-Lung Ventilation/adverse effects
14.
J Sleep Res ; : e14115, 2023 Dec 11.
Article in English | MEDLINE | ID: mdl-38083980

ABSTRACT

Although understanding the physiological mechanisms of obstructive sleep apnea (OSA) is important for treating OSA, limited studies have examined OSA patients' sleep architecture at the epoch-by-epoch level and analysed the impact of sleep position and stage on OSA pathogenesis. The epoch-labelled polysomnogram was analysed multidimensionally to investigate the effect of sleep position on the sleep architecture and risk factors of apnea in patients with OSA. This retrospective multicentric case-control study reviewed full-night diagnostic polysomnography of 6983 participants. The difference in the proportion of time spent supine during non-rapid eye movement (NREM) and REM stages, and the mean duration of respiratory events per body position were evaluated. The frequency of sleep stage transition per body position shift type was computed. Further subgroup analysis was performed based on OSA severity and positional dependency. Supine time in patients with OSA varied across sleep stages, with lower proportions in N3 and REM, and shorter durations with severity. Patients with OSA spent less time in supine positions during N3 and REM, and experienced longer apnea events in both positions compared to the control group. The frequency of all sleep stage transitions increased with OSA severity and was higher among non-positional OSA than positional OSA and the control group, regardless of body position shift type. The sleep stage transition from N3 and REM to wakefulness was notably heightened during position shift. Understanding the sleep architecture of patients with OSA requires analysing various sleep characteristics including sleep position simultaneously, with future studies focusing on position detection to predict sleep stages and respiratory events.

15.
Sci Rep ; 13(1): 20776, 2023 11 27.
Article in English | MEDLINE | ID: mdl-38012277

ABSTRACT

Sugammadex reverses neuromuscular blockade by encapsulating steroidal neuromuscular blockers; therefore, it does not pharmacologically affect sedation levels. However, some clinicians avoid using it because of sudden unwanted acting out or patient arousal. Previous studies suggested sugammadex-induced awakening, but frontal muscle contraction after sugammadex administration compromised reliability of results obtained from EEG-based anesthesia depth monitoring tools like bispectral index (BIS). We hypothesized that sugammadex would affect patients' arousal depending on their baseline levels of sedation. We evaluated arousal signs after sugammadex administration with BIS between 25 - 35 and 45 - 55 under steady-state propofol-remifentanil anesthesia at the end of a surgery (n = 33 in each group). After sugammadex administration, twelve patients with a BIS of 45 - 55 showed clinical signs of awakening but none with a BIS of 25 - 35 (36.4% vs. 0%, P = 0.001). The distribution of the modified observer's assessment of alertness/sedation scale scores was also significantly different between the two groups (P < 0.001). Changes in the BIS were significantly greater in the BIS 45 - 55 than in the 25 - 35 group (median difference, 7; 95% CI 2 - 19, P = 0.002). Arousal after sugammadex was affected by patient sedation levels, and clinical signs of awakening appeared only in those with BIS 45 - 55. Unwanted arousal of the patient should be considered when using sugammadex under shallow anesthesia.Clinical trial registry number: Clinical Trial Registry of Korea ( https://cris.nih.go.kr ; Principal investigator: Jieae Kim; Registration number: KCT0006248; Date of first registration: 11/06/2021).


Subject(s)
Anesthesia , Neuromuscular Blockade , Propofol , Humans , Sugammadex/pharmacology , Propofol/pharmacology , Neuromuscular Blockade/methods , Remifentanil/pharmacology , Reproducibility of Results , Anesthesia/methods , Anesthetics, Intravenous , Arousal
17.
Nutrients ; 15(19)2023 Sep 27.
Article in English | MEDLINE | ID: mdl-37836456

ABSTRACT

Atopic dermatitis (AD) is a chronic inflammatory disease characterized by dry and itchy skin. Recently, it has been reported that oxidative stress is involved in skin diseases, possibly including AD. Vitamin C, also referred to as ascorbic acid, is a vital water-soluble compound that functions as an essential nutrient. It plays a significant role as both an antioxidant and an additive in various pharmaceutical and food products. Despite the fact that vitamin C is easily oxidized, we have developed NXP081, a single-stranded DNA aptamer that selectively binds to vitamin C, thereby inhibiting its oxidation. The objective of the current research was to examine the impact of NXP081, an animal model of AD induced by 2,4-dinitrofluorobenzene (DNFB). The experimental drug NXP081, when taken orally, showed promising results in reducing inflammation and improving the skin conditions caused by DNFB. The administration of NXP081 resulted in a significant reduction in ear swelling and a noticeable improvement in the appearance of skin lesions. In addition, the administration of NXP081 resulted in a significant decrease in the migration of mast cells in the skin lesions induced by DNFB. Moreover, NXP081 inhibited the production of interferon-gamma (IFN-γ) in CD4+ T cells that were activated and derived from the lymph nodes. Our findings provide useful information about the anti-inflammatory effect of NXP081 on AD.


Subject(s)
Aptamers, Nucleotide , Dermatitis, Atopic , Skin Diseases , Mice , Animals , Dermatitis, Atopic/chemically induced , Dermatitis, Atopic/drug therapy , Dermatitis, Atopic/metabolism , Dinitrofluorobenzene/adverse effects , Mice, Inbred BALB C , Aptamers, Nucleotide/adverse effects , Ascorbic Acid/metabolism , CD4-Positive T-Lymphocytes/metabolism , Skin Diseases/metabolism , Vitamins/pharmacology , Skin/metabolism , Cytokines/metabolism
18.
Nat Commun ; 14(1): 6768, 2023 Oct 25.
Article in English | MEDLINE | ID: mdl-37880242

ABSTRACT

Interest in securing energy production channels from renewable sources is higher than ever due to the daily observation of the impacts of climate change. A key renewable energy harvesting strategy achieving carbon neutral cycles is artificial photosynthesis. Solar-to-fuel routes thus far relied on elaborately crafted semiconductors, undermining the cost-efficiency of the system. Furthermore, fuels produced required separation prior to utilization. As an artificial photosynthesis design, here we demonstrate the conversion of swimming green algae into photovoltaic power stations. The engineered algae exhibit bioelectrogenesis, en route to energy storage in hydrogen. Notably, fuel formation requires no additives or external bias other than CO2 and sunlight. The cellular power stations autoregulate the oxygen level during artificial photosynthesis, granting immediate utility of the photosynthetic hydrogen without separation. The fuel production scales linearly with the reactor volume, which is a necessary trait for contributing to the large-scale renewable energy portfolio.

19.
Int J Mol Sci ; 24(17)2023 Aug 23.
Article in English | MEDLINE | ID: mdl-37685909

ABSTRACT

Plasmonic molecules, which are geometrically well-defined plasmonic metal nanoparticle clusters, have attracted significant attention due to their enhancement of light-matter interactions owing to a stronger electric field enhancement than that by single particles. High-resolution lithography techniques provide precise positioning of plasmonic nanoparticles, but their fabrication costs are excessively high. In this study, we propose a lithography-free, self-assembly fabrication method, termed the dual-dewetting process, which allows the control of the size and density of gold nanoparticles. This process involves depositing a gold thin film on a substrate and inducing dewetting through thermal annealing, followed by a second deposition and annealing. The method achieves a uniform distribution of particle size and density, along with increased particle density, across a 6-inch wafer. The superiority of the method is confirmed by a 30-fold increase in the signal intensity of surface-enhanced Raman scattering following the additional dewetting with an 8 nm film, compared to single dewetting alone. Our findings indicate that the dual-dewetting method provides a simple and efficient approach to enable a variety of plasmonic applications through efficient plasmonic molecule large-area fabrication.


Subject(s)
Metal Nanoparticles , Gold , Electricity , Motion Pictures , Particle Size
20.
J Exerc Rehabil ; 19(4): 237-244, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37662529

ABSTRACT

This study aimed to investigate the effect of lower-extremity strengthening exercise (LSE) with and without blood flow restriction (BFR) on the left thigh on golf performance. Eighteen amateur golfers with more than 1 year of golf experience participated in the study and were randomly divided into two groups: LSE+BFR group (LSE with BFR on the left thigh, n=9) and LSE group (LSE without BFR, n=9). The LSEs consisted of squats, lunges, and standing leg curls. All exercises were performed 3 times a week for 6 weeks. Changes in thigh muscle strength, plantar foot pressure (weight transfer), and golf performance, such as club head speed, ball speed, and carry distance were measured before and after the exercise program. Right knee extension (P<0.001) and left knee extension and flexion (P<0.001) strength were higher in the LSE+BFR group than in the LSE group. The changes in plantar foot pressure confirmed that smooth weight transfer appeared in E1 (event 1) (address) (P<0.05) of the LSE+BFR group, which confirmed that the carry distance (P<0.05) of the LSE+BFR group improved after the exercise program. The results of this study showed that BFR muscle strengthening exercise are more effective than basic simple muscle strengthening exercise in improving golf performance through muscle strength and weight transfer improvement.

SELECTION OF CITATIONS
SEARCH DETAIL
...