1.
Am J Infect Control ; 41(8): 746-8, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23685092

ABSTRACT

There is evidence that contamination of patient rooms from previous occupants is associated with hospital-associated Clostridium difficile infection (HA-CDI). During January 2011, the use of 2 portable pulsed xenon ultraviolet light devices (PPX-UV) to disinfect patient rooms was added to routine hospital discharge cleaning in a community hospital. In 2010, the HA-CDI rate was 9.46 per 10,000 patient-days; in 2011, the HA-CDI rates was 4.45 per 10,000 patient-days (53% reduction, P = .01). The number of deaths and colectomies attributable to hospital-associated C difficile infection also declined dramatically.


Subject(s)
Clostridioides difficile/radiation effects , Cross Infection/prevention & control , Disinfection , Enterocolitis, Pseudomembranous/prevention & control , Ultraviolet Rays , Xenon/pharmacology , Clostridium Infections/epidemiology , Clostridium Infections/mortality , Clostridium Infections/prevention & control , Colectomy/statistics & numerical data , Cross Infection/epidemiology , Cross Infection/mortality , Disinfectants/pharmacology , Disinfection/instrumentation , Disinfection/methods , Enterocolitis, Pseudomembranous/epidemiology , Enterocolitis, Pseudomembranous/mortality , Hospitals, Community/statistics & numerical data , Humans , Infection Control/instrumentation , Infection Control/methods