1.
J Acoust Soc Am ; 155(5): 2948-2958, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38717204

ABSTRACT

Arteriosclerosis is a major risk factor for cardiovascular disease and results in arterial vessel stiffening. Velocity estimation of the pulse wave sent by the heart and propagating into the arteries is a widely accepted biomarker. This symmetrical pulse wave propagates at a speed which is related to the Young's modulus through the Moens Korteweg (MK) equation. Recently, an antisymmetric flexural wave has been observed in vivo. Unlike the symmetrical wave, it is highly dispersive. This property offers promising applications for monitoring arterial stiffness and early detection of atheromatous plaque. However, as far as it is known, no equivalent of the MK equation exists for flexural pulse waves. To bridge this gap, a beam based theory was developed, and approximate analytical solutions were reached. An experiment in soft polymer artery phantoms was built to observe the dispersion of flexural waves. A good agreement was found between the analytical expression derived from beam theory and experiments. Moreover, numerical simulations validated wave speed dependence on the elastic and geometric parameters at low frequencies. Clinical applications, such as arterial age estimation and arterial pressure measurement, are foreseen.


Subject(s)
Models, Cardiovascular , Phantoms, Imaging , Pulse Wave Analysis , Vascular Stiffness , Pulse Wave Analysis/methods , Humans , Elastic Modulus , Computer Simulation , Arteries/physiology , Arteries/physiopathology , Numerical Analysis, Computer-Assisted , Blood Flow Velocity/physiology
2.
Ophthalmic Physiol Opt ; 43(3): 544-557, 2023 05.
Article in English | MEDLINE | ID: mdl-36943177

ABSTRACT

PURPOSE: To develop a point-of-care (POC) device using high-frequency ultrasound (US) for evaluating microstructural changes in the anterior sclera associated with myopia. METHODS: The proposed POC device must satisfy four primary requirements for effective clinical use: the measurement component is handheld; the software must be simple and provide real-time feedback; patient safety and health data security requirements set forth by relevant governing bodies must be satisfied and the measurement data must have sufficient signal-to-noise ratio (SNR) and repeatability. Radiofrequency (RF) echo data acquired by the POC device will be processed using our quantitative US methods to characterise tissue microstructure and biomechanical properties. RESULTS: All stated requirements have been met in the developed POC device. The high-frequency transducer is housed in a custom, 3D-printed, pen-like holder that allows for easy measurements of the anterior sclera. Custom software provides a simple interface for data acquisition, real-time data display and secure data storage. Exposimetry measurements of the US pressure field indicate device compliance with United States Food and Drug Administration limits for ophthalmic US. In vivo measurements on a volunteer suggest the RF data SNR and acquisition consistency are suitable for quantitative analysis. CONCLUSIONS: A fully functioning POC device using high-frequency US has been created for evaluating the microstructure of the anterior sclera. Planned studies using the POC device to scan the eyes of myopia patients will help clarify how the anterior sclera microstructure may be affected by myopia. If effective, this portable, inexpensive and user-friendly system could be an important part of routine eye examinations.


Subject(s)
Myopia , Sclera , Humans , Sclera/diagnostic imaging , Point-of-Care Systems , Myopia/diagnosis